{"schemaVersion":1,"coordinateSystem":{"units":"feet","outline":"[u,yFromFloor107]","faceConvention":"north/south u=east; east/west u=south. North z=-103.5833333; east x=103.5833333; south z=103.5833333; west x=-103.5833333. Use tower-specific Floor107 elevation.","depthConvention":"depthFt null means a flat, double-sided source elevation silhouette; do not invent extrusion.","registration":{"north":{"centerCadIn":1101.899870696352,"gridLabelCenterCadIn":1102.024870696352,"gridRegistrationCorrectionIn":-0.125,"uSign":-1},"east":{"centerCadIn":13325.75040134651,"gridLabelCenterCadIn":13325.87540134651,"gridRegistrationCorrectionIn":-0.125,"uSign":-1},"south":{"centerCadIn":9347.574163510824,"gridLabelCenterCadIn":9347.699163510824,"gridRegistrationCorrectionIn":-0.125,"uSign":1},"west":{"centerCadIn":5080.076108532044,"gridLabelCenterCadIn":5080.201108532044,"gridRegistrationCorrectionIn":-0.125,"uSign":1}}},"coverage":{"minYFt":-5.833333333333333,"maxYFt":49.083333333333336,"columnCountPerTower":236,"spandrelBayCountPerTower":696,"floors":[107,108,110],"roofCapTopReferenceFt":58.583333333333336,"roofScheduleReferenceFt":58.5,"roofCapRender":"line-reference-only"},"sources":[{"id":"lza_wtc1_cad","path":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","sha256":"7cf03c2fed5c6e93538c10a164269869227f911896e03a4f459ae1e71fd1ef42","title":"LZA-1 WTC1 north/west/south/east facade forensic CAD elevations; progress print 2002-03-27","status":"2D elevation drawing, not a 3D structural model; layer names alone do not establish fabrication dimensions"},{"id":"nist_1_2a_3_2_7","path":"sources/text/NCSTAR1-2A.txt","citation":"NIST NCSTAR 1-2A \u00a73.2.7, printed p.41 / PDF p.75","supports":"Upper spandrel depths vary at108/110;7\u00d75 structural tubes and rolled shapes."},{"id":"nist_1_3a_2_1_4","path":"sources/text/NCSTAR1-3A_final.txt","citation":"NIST NCSTAR 1-3A \u00a72.1.4, printed p.12 / PDF p.38","supports":"Exterior columns107\u2013110 alternate small tubes and wide flanges; wide flanges support floors."}],"applicability":{"wtc1":"Direct 2D LZA WTC1 elevation envelopes, registered to column IDs and floor107\u2013110 ordinates. These are not verified steel fabrication sections.","wtc2":"Qualified shared-system visualization using the WTC1 traced envelopes; NIST describes the common upper-wall system. Exact WTC2 fa\u00e7ade elevations and section schedules remain unresolved."},"limitations":["Unknown normal depths are flat silhouettes; none is a guessed thin-wall steel section.","CAD column faces are18.75in wide below the107 transition, rather than the usual14in steel-box width. This supports treating this drawing as elevation-envelope evidence; it cannot establish bare steel or cladding thickness.","No complete corner-return assembly is asserted. Terminal column projections are retained, but the diagonal/cross-face corner closure is omitted.","Floor109 has no horizontal S-Spandrels band in this drawing. Absence from this trace is not proof of absence of all floor109 edge steel.","CAD roof-cap linework reaches 58ft7in above107, one inch above the supplied58ft6in roof-panel reference; it is retained as line-only reference geometry because its structural/cladding identity is unresolved.","Drawing splice-line breaks are closed for band envelopes. No bolts,welds,splices or connections are created.","Band envelopes follow the repeated horizontal source levels. One terminal bay top stroke lies0.3835in above the repeated110top; that isolated CAD discrepancy is not propagated into a new band step.","Exact Book4 upper-column/spandrel types and tower schedules are indexed in NIST Appendix B but not present under their indexed filenames in the current source tree."],"members":[{"kind":"column","column":159,"columnIndex":58,"outlineFt":[[98.375,-5.8333334],[98.375,-0.0],[98.375,1.25],[98.375,17.5],[98.375,22.1666666],[98.375,37.5],[98.375,49.0833333],[96.1666666,49.0833333],[96.1666666,37.5],[95.9791666,37.5],[95.9791666,22.1666666],[96.1666666,22.1666666],[96.1666666,17.5],[96.1666666,1.25],[96.1170343,-0.0],[95.8854166,-5.8333334]],"sourceHandles":["9F05","9F07","9F0E","9F0F","9F13","AE76","AE77","AE7D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":159,"id":"upper-exterior-1-north-column-159","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":158,"columnIndex":57,"outlineFt":[[94.1145833,-5.8333334],[93.8333333,1.25],[93.8333333,12.8333333],[93.625,12.8333333],[93.625,22.1666666],[93.625,37.5],[93.625,46.8333333],[93.0416666,46.8333333],[93.0416666,37.5],[93.0416666,22.1666666],[93.0416666,12.8333333],[92.8333333,12.8333333],[92.8333333,1.25],[92.5520833,-5.8333334]],"sourceHandles":["9EF9","9EFB","9F02","9F03","A149","A14A","A14D","A14E","A19E","A19F","A67C","A67D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":158,"id":"upper-exterior-1-north-column-158","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":157,"columnIndex":56,"outlineFt":[[90.78125,-5.8333334],[90.5,1.25],[90.5,12.8333333],[90.5,22.1666666],[90.6875,22.1666666],[90.6875,37.5],[90.5,37.5],[90.5,46.8333333],[89.5,46.8333333],[89.5,37.5],[89.3125,37.5],[89.3125,22.1666666],[89.5,22.1666666],[89.5,12.8333333],[89.5,1.25],[89.21875,-5.8333334]],"sourceHandles":["9EFF","9F3F","9F42","9F43","A12F","A130","A13B","A13C","A13D","A13E"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":157,"id":"upper-exterior-1-north-column-157","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":156,"columnIndex":55,"outlineFt":[[87.4479166,-5.8333334],[87.1666666,1.25],[87.1666666,12.8333333],[86.9583333,12.8333333],[86.9583333,22.1666666],[86.9583333,37.5],[86.9583333,46.8333333],[86.375,46.8333333],[86.375,37.5],[86.375,22.1666666],[86.375,12.8333333],[86.1666666,12.8333333],[86.1666666,1.25],[85.8854166,-5.8333334]],"sourceHandles":["9F40","9F47","9F4A","9F4B","A127","A128","A138","A139","A1A0","A1A1","A672","A673"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":156,"id":"upper-exterior-1-north-column-156","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":155,"columnIndex":54,"outlineFt":[[84.1145833,-5.8333334],[83.8333333,1.25],[83.8333333,12.8333333],[83.8333333,22.1666666],[84.0208333,22.1666666],[84.0208333,37.5],[83.8333333,37.5],[83.8333333,46.8333333],[82.8333333,46.8333333],[82.8333333,37.5],[82.6458333,37.5],[82.6458333,22.1666666],[82.8333333,22.1666666],[82.8333333,12.8333333],[82.8333333,1.25],[82.5520833,-5.8333334]],"sourceHandles":["9F48","9F4F","9F52","9F53","A772","A773","A778","A779","A77A","A77B"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":155,"id":"upper-exterior-1-north-column-155","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":154,"columnIndex":53,"outlineFt":[[80.78125,-5.8333334],[80.5,1.25],[80.5,12.8333333],[80.2916666,12.8333333],[80.2916666,22.1666666],[80.2916666,37.5],[80.2916666,46.8333333],[79.7083333,46.8333333],[79.7083333,37.5],[79.7083333,22.1666666],[79.7083333,12.8333333],[79.5,12.8333333],[79.5,1.25],[79.21875,-5.8333334]],"sourceHandles":["9F50","9F57","9F5A","9F5B","A76E","A76F","A776","A777","A78E","A78F","A79F","A7A0"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":154,"id":"upper-exterior-1-north-column-154","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":153,"columnIndex":52,"outlineFt":[[77.4479166,-5.8333334],[77.1666666,1.25],[77.1666666,12.8333333],[77.1666666,22.1666666],[77.3541666,22.1666666],[77.3541666,37.5],[77.1666666,37.5],[77.1666666,46.8333333],[76.1666666,46.8333333],[76.1666666,37.5],[75.9791666,37.5],[75.9791666,22.1666666],[76.1666666,22.1666666],[76.1666666,12.8333333],[76.1666666,1.25],[75.8854166,-5.8333334]],"sourceHandles":["9F58","9F5F","9F62","9F63","A7B5","A7B6","A7BB","A7BC","A7BD","A7BE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":153,"id":"upper-exterior-1-north-column-153","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":152,"columnIndex":51,"outlineFt":[[74.1145833,-5.8333334],[73.8333333,1.25],[73.8333333,12.8333333],[73.625,12.8333333],[73.625,22.1666666],[73.625,37.5],[73.625,46.8333333],[73.0416666,46.8333333],[73.0416666,37.5],[73.0416666,22.1666666],[73.0416666,12.8333333],[72.8333333,12.8333333],[72.8333333,1.25],[72.5520833,-5.8333334]],"sourceHandles":["9F60","9F67","9F6A","9F6B","A7B1","A7B2","A7B9","A7BA","A7D1","A7D2","A7E2","A7E3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":152,"id":"upper-exterior-1-north-column-152","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":151,"columnIndex":50,"outlineFt":[[70.78125,-5.8333334],[70.5,1.25],[70.5,12.8333333],[70.5,22.1666666],[70.6875,22.1666666],[70.6875,37.5],[70.5,37.5],[70.5,46.8333333],[69.5,46.8333333],[69.5,37.5],[69.3125,37.5],[69.3125,22.1666666],[69.5,22.1666666],[69.5,12.8333333],[69.5,1.25],[69.21875,-5.8333334]],"sourceHandles":["9F68","9F6F","9F72","9F73","A7F8","A7F9","A7FE","A7FF","A800","A801"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":151,"id":"upper-exterior-1-north-column-151","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":150,"columnIndex":49,"outlineFt":[[67.4479166,-5.8333334],[67.1666666,1.25],[67.1666666,12.8333333],[66.9583333,12.8333333],[66.9583333,22.1666666],[66.9583333,37.5],[66.9583333,46.8333333],[66.375,46.8333333],[66.375,37.5],[66.375,22.1666666],[66.375,12.8333333],[66.1666666,12.8333333],[66.1666666,1.25],[65.8854166,-5.8333334]],"sourceHandles":["9F70","9F77","9F7A","9F7B","A7F4","A7F5","A7FC","A7FD","A814","A815","A825","A826"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":150,"id":"upper-exterior-1-north-column-150","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":149,"columnIndex":48,"outlineFt":[[64.1145833,-5.8333334],[63.8333333,1.25],[63.8333333,12.8333333],[63.8333333,22.1666666],[64.0208333,22.1666666],[64.0208333,37.5],[63.8333333,37.5],[63.8333333,46.8333333],[62.8333333,46.8333333],[62.8333333,37.5],[62.6458333,37.5],[62.6458333,22.1666666],[62.8333333,22.1666666],[62.8333333,12.8333333],[62.8333333,1.25],[62.5520833,-5.8333334]],"sourceHandles":["9F78","9F7F","9F82","9F83","A83B","A83C","A841","A842","A843","A844"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":149,"id":"upper-exterior-1-north-column-149","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":148,"columnIndex":47,"outlineFt":[[60.78125,-5.8333334],[60.5,1.25],[60.5,12.8333333],[60.2916666,12.8333333],[60.2916666,22.1666666],[60.2916666,37.5],[60.2916666,46.8333333],[59.7083333,46.8333333],[59.7083333,37.5],[59.7083333,22.1666666],[59.7083333,12.8333333],[59.5,12.8333333],[59.5,1.25],[59.21875,-5.8333334]],"sourceHandles":["9F80","9F87","9F8A","9F8B","A837","A838","A83F","A840","A857","A858","A868","A869"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":148,"id":"upper-exterior-1-north-column-148","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":147,"columnIndex":46,"outlineFt":[[57.4479166,-5.8333334],[57.1666666,1.25],[57.1666666,12.8333333],[57.1666666,22.1666666],[57.3541666,22.1666666],[57.3541666,37.5],[57.1666666,37.5],[57.1666666,46.8333333],[56.1666666,46.8333333],[56.1666666,37.5],[55.9791666,37.5],[55.9791666,22.1666666],[56.1666666,22.1666666],[56.1666666,12.8333333],[56.1666666,1.25],[55.8854166,-5.8333334]],"sourceHandles":["9F88","9F8F","9F92","9F93","A87E","A87F","A884","A885","A886","A887"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":147,"id":"upper-exterior-1-north-column-147","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":146,"columnIndex":45,"outlineFt":[[54.1145833,-5.8333334],[53.8333333,1.25],[53.8333333,12.8333333],[53.625,12.8333333],[53.625,22.1666666],[53.625,37.5],[53.625,46.8333333],[53.0416666,46.8333333],[53.0416666,37.5],[53.0416666,22.1666666],[53.0416666,12.8333333],[52.8333333,12.8333333],[52.8333333,1.25],[52.5520833,-5.8333334]],"sourceHandles":["9F90","9F97","9F9A","9F9B","A87A","A87B","A882","A883","A89A","A89B","A8AB","A8AC"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":146,"id":"upper-exterior-1-north-column-146","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":145,"columnIndex":44,"outlineFt":[[50.78125,-5.8333334],[50.5,1.25],[50.5,12.8333333],[50.5,22.1666666],[50.6875,22.1666666],[50.6875,37.5],[50.5,37.5],[50.5,46.8333333],[49.5,46.8333333],[49.5,37.5],[49.3125,37.5],[49.3125,22.1666666],[49.5,22.1666666],[49.5,12.8333333],[49.5,1.25],[49.21875,-5.8333334]],"sourceHandles":["9F98","9F9F","9FA2","9FA3","A8C1","A8C2","A8C7","A8C8","A8C9","A8CA"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":145,"id":"upper-exterior-1-north-column-145","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":144,"columnIndex":43,"outlineFt":[[47.4479166,-5.8333334],[47.1666666,1.25],[47.1666666,12.8333333],[46.9583333,12.8333333],[46.9583333,22.1666666],[46.9583333,37.5],[46.9583333,46.8333333],[46.375,46.8333333],[46.375,37.5],[46.375,22.1666666],[46.375,12.8333333],[46.1666666,12.8333333],[46.1666666,1.25],[45.8854166,-5.8333334]],"sourceHandles":["9FA0","9FA7","9FAA","9FAB","A8BD","A8BE","A8C5","A8C6","A8DD","A8DE","A8EE","A8EF"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":144,"id":"upper-exterior-1-north-column-144","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":143,"columnIndex":42,"outlineFt":[[44.1145833,-5.8333334],[43.8333333,1.25],[43.8333333,12.8333333],[43.8333333,22.1666666],[44.0208333,22.1666666],[44.0208333,37.5],[43.8333333,37.5],[43.8333333,46.8333333],[42.8333333,46.8333333],[42.8333333,37.5],[42.6458333,37.5],[42.6458333,22.1666666],[42.8333333,22.1666666],[42.8333333,12.8333333],[42.8333333,1.25],[42.5520833,-5.8333334]],"sourceHandles":["9FA8","9FAF","9FB2","9FB3","A904","A905","A90A","A90B","A90C","A90D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":143,"id":"upper-exterior-1-north-column-143","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":142,"columnIndex":41,"outlineFt":[[40.78125,-5.8333334],[40.5,1.25],[40.5,12.8333333],[40.2916666,12.8333333],[40.2916666,22.1666666],[40.2916666,37.5],[40.2916666,46.8333333],[39.7083333,46.8333333],[39.7083333,37.5],[39.7083333,22.1666666],[39.7083333,12.8333333],[39.5,12.8333333],[39.5,1.25],[39.21875,-5.8333334]],"sourceHandles":["9FB0","9FB7","9FBA","9FBB","A900","A901","A908","A909","A920","A921","A931","A932"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":142,"id":"upper-exterior-1-north-column-142","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":141,"columnIndex":40,"outlineFt":[[37.4479166,-5.8333334],[37.1666666,1.25],[37.1666666,12.8333333],[37.1666666,22.1666666],[37.3541666,22.1666666],[37.3541666,37.5],[37.1666666,37.5],[37.1666666,46.8333333],[36.1666666,46.8333333],[36.1666666,37.5],[35.9791666,37.5],[35.9791666,22.1666666],[36.1666666,22.1666666],[36.1666666,12.8333333],[36.1666666,1.25],[35.8854166,-5.8333334]],"sourceHandles":["9FB8","9FBF","9FC2","9FC3","A947","A948","A94D","A94E","A94F","A950"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":141,"id":"upper-exterior-1-north-column-141","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":140,"columnIndex":39,"outlineFt":[[34.1145833,-5.8333334],[33.8333333,1.25],[33.8333333,12.8333333],[33.625,12.8333333],[33.625,22.1666666],[33.625,37.5],[33.625,46.8333333],[33.0416666,46.8333333],[33.0416666,37.5],[33.0416666,22.1666666],[33.0416666,12.8333333],[32.8333333,12.8333333],[32.8333333,1.25],[32.5520833,-5.8333334]],"sourceHandles":["9FC0","9FC7","9FCA","9FCB","A943","A944","A94B","A94C","A963","A964","A974","A975"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":140,"id":"upper-exterior-1-north-column-140","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":139,"columnIndex":38,"outlineFt":[[30.78125,-5.8333334],[30.5,1.25],[30.5,12.8333333],[30.5,22.1666666],[30.6875,22.1666666],[30.6875,37.5],[30.5,37.5],[30.5,46.8333333],[29.5,46.8333333],[29.5,37.5],[29.3125,37.5],[29.3125,22.1666666],[29.5,22.1666666],[29.5,12.8333333],[29.5,1.25],[29.21875,-5.8333334]],"sourceHandles":["9FC8","9FCF","9FD2","9FD3","A98A","A98B","A990","A991","A992","A993"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":139,"id":"upper-exterior-1-north-column-139","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":138,"columnIndex":37,"outlineFt":[[27.4479166,-5.8333334],[27.1666666,1.25],[27.1666666,12.8333333],[26.9583333,12.8333333],[26.9583333,22.1666666],[26.9583333,37.5],[26.9583333,46.8333333],[26.375,46.8333333],[26.375,37.5],[26.375,22.1666666],[26.375,12.8333333],[26.1666666,12.8333333],[26.1666666,1.25],[25.8854166,-5.8333334]],"sourceHandles":["9FD0","9FD7","9FDA","9FDB","A986","A987","A98E","A98F","A9A6","A9A7","A9B7","A9B8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":138,"id":"upper-exterior-1-north-column-138","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":137,"columnIndex":36,"outlineFt":[[24.1145833,-5.8333334],[23.8333333,1.25],[23.8333333,12.8333333],[23.8333333,22.1666666],[24.0208333,22.1666666],[24.0208333,37.5],[23.8333333,37.5],[23.8333333,46.8333333],[22.8333333,46.8333333],[22.8333333,37.5],[22.6458333,37.5],[22.6458333,22.1666666],[22.8333333,22.1666666],[22.8333333,12.8333333],[22.8333333,1.25],[22.5520833,-5.8333334]],"sourceHandles":["9FD8","9FDF","9FE2","9FE3","A9CD","A9CE","A9D3","A9D4","A9D5","A9D6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":137,"id":"upper-exterior-1-north-column-137","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":136,"columnIndex":35,"outlineFt":[[20.78125,-5.8333334],[20.5,1.25],[20.5,12.8333333],[20.2916666,12.8333333],[20.2916666,22.1666666],[20.2916666,37.5],[20.2916666,46.8333333],[19.7083333,46.8333333],[19.7083333,37.5],[19.7083333,22.1666666],[19.7083333,12.8333333],[19.5,12.8333333],[19.5,1.25],[19.21875,-5.8333334]],"sourceHandles":["9FE0","9FE7","9FEA","9FEB","A9C9","A9CA","A9D1","A9D2","A9E9","A9EA","A9FA","A9FB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":136,"id":"upper-exterior-1-north-column-136","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":135,"columnIndex":34,"outlineFt":[[17.4479166,-5.8333334],[17.1666666,1.25],[17.1666666,12.8333333],[17.1666666,22.1666666],[17.3541666,22.1666666],[17.3541666,37.5],[17.1666666,37.5],[17.1666666,46.8333333],[16.1666666,46.8333333],[16.1666666,37.5],[15.9791666,37.5],[15.9791666,22.1666666],[16.1666666,22.1666666],[16.1666666,12.8333333],[16.1666666,1.25],[15.8854166,-5.8333334]],"sourceHandles":["9FE8","9FEF","9FF2","9FF3","AA10","AA11","AA16","AA17","AA18","AA19"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":135,"id":"upper-exterior-1-north-column-135","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":134,"columnIndex":33,"outlineFt":[[14.1145833,-5.8333334],[13.8333333,1.25],[13.8333333,12.8333333],[13.625,12.8333333],[13.625,22.1666666],[13.625,37.5],[13.625,46.8333333],[13.0416666,46.8333333],[13.0416666,37.5],[13.0416666,22.1666666],[13.0416666,12.8333333],[12.8333333,12.8333333],[12.8333333,1.25],[12.5520833,-5.8333334]],"sourceHandles":["9FF0","9FF7","9FFA","9FFB","AA0C","AA0D","AA14","AA15","AA2C","AA2D","AA3D","AA3E"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":134,"id":"upper-exterior-1-north-column-134","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":133,"columnIndex":32,"outlineFt":[[10.78125,-5.8333334],[10.5,1.25],[10.5,12.8333333],[10.5,22.1666666],[10.6875,22.1666666],[10.6875,37.5],[10.5,37.5],[10.5,46.8333333],[9.5,46.8333333],[9.5,37.5],[9.3125,37.5],[9.3125,22.1666666],[9.5,22.1666666],[9.5,12.8333333],[9.5,1.25],[9.21875,-5.8333334]],"sourceHandles":["9FF8","9FFF","A002","A003","AA53","AA54","AA59","AA5A","AA5B","AA5C"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":133,"id":"upper-exterior-1-north-column-133","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":132,"columnIndex":31,"outlineFt":[[7.4479166,-5.8333334],[7.1666666,1.25],[7.1666666,12.8333333],[6.9583333,12.8333333],[6.9583333,22.1666666],[6.9583333,37.5],[6.9583333,46.8333333],[6.375,46.8333333],[6.375,37.5],[6.375,22.1666666],[6.375,12.8333333],[6.1666666,12.8333333],[6.1666666,1.25],[5.8854166,-5.8333334]],"sourceHandles":["A000","A007","A00A","A00B","AA4F","AA50","AA57","AA58","AA6F","AA70","AA80","AA81"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":132,"id":"upper-exterior-1-north-column-132","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":131,"columnIndex":30,"outlineFt":[[4.1145833,-5.8333334],[3.8333333,1.25],[3.8333333,12.8333333],[3.8333333,22.1666666],[4.0208333,22.1666666],[4.0208333,37.5],[3.8333333,37.5],[3.8333333,46.8333333],[2.8333333,46.8333333],[2.8333333,37.5],[2.6458333,37.5],[2.6458333,22.1666666],[2.8333333,22.1666666],[2.8333333,12.8333333],[2.8333333,1.25],[2.5520833,-5.8333334]],"sourceHandles":["A008","A00F","A012","A013","AA96","AA97","AA9C","AA9D","AA9E","AA9F"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":131,"id":"upper-exterior-1-north-column-131","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":130,"columnIndex":29,"outlineFt":[[0.78125,-5.8333334],[0.5,1.25],[0.5,12.8333333],[0.2916666,12.8333333],[0.2916666,22.1666666],[0.2916666,37.5],[0.2916666,46.8333333],[-0.2916667,46.8333333],[-0.2916667,37.5],[-0.2916667,22.1666666],[-0.2916667,12.8333333],[-0.5,12.8333333],[-0.5,1.25],[-0.78125,-5.8333334]],"sourceHandles":["A010","A017","A01A","A01B","AA92","AA93","AA9A","AA9B","AAB2","AAB3","AAC3","AAC4"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":130,"id":"upper-exterior-1-north-column-130","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":129,"columnIndex":28,"outlineFt":[[-2.5520834,-5.8333334],[-2.8333334,1.25],[-2.8333334,12.8333333],[-2.8333334,22.1666666],[-2.6458334,22.1666666],[-2.6458334,37.5],[-2.8333334,37.5],[-2.8333334,46.8333333],[-3.8333334,46.8333333],[-3.8333334,37.5],[-4.0208334,37.5],[-4.0208334,22.1666666],[-3.8333334,22.1666666],[-3.8333334,12.8333333],[-3.8333334,1.25],[-4.1145834,-5.8333334]],"sourceHandles":["A018","A01F","A022","A023","AAD9","AADA","AADF","AAE0","AAE1","AAE2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":129,"id":"upper-exterior-1-north-column-129","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":128,"columnIndex":27,"outlineFt":[[-5.8854167,-5.8333334],[-6.1666667,1.25],[-6.1666667,12.8333333],[-6.375,12.8333333],[-6.375,22.1666666],[-6.375,37.5],[-6.375,46.8333333],[-6.9583334,46.8333333],[-6.9583334,37.5],[-6.9583334,22.1666666],[-6.9583334,12.8333333],[-7.1666667,12.8333333],[-7.1666667,1.25],[-7.4479167,-5.8333334]],"sourceHandles":["A020","A027","A02A","A02B","AAD5","AAD6","AADD","AADE","AAF5","AAF6","AB06","AB07"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":128,"id":"upper-exterior-1-north-column-128","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":127,"columnIndex":26,"outlineFt":[[-9.21875,-5.8333334],[-9.5,1.25],[-9.5,12.8333333],[-9.5,22.1666666],[-9.3125,22.1666666],[-9.3125,37.5],[-9.5,37.5],[-9.5,46.8333333],[-10.5,46.8333333],[-10.5,37.5],[-10.6875,37.5],[-10.6875,22.1666666],[-10.5,22.1666666],[-10.5,12.8333333],[-10.5,1.25],[-10.78125,-5.8333334]],"sourceHandles":["A028","A02F","A032","A033","AB1C","AB1D","AB22","AB23","AB24","AB25"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":127,"id":"upper-exterior-1-north-column-127","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":126,"columnIndex":25,"outlineFt":[[-12.5520834,-5.8333334],[-12.8333334,1.25],[-12.8333334,12.8333333],[-13.0416667,12.8333333],[-13.0416667,22.1666666],[-13.0416667,37.5],[-13.0416667,46.8333333],[-13.625,46.8333333],[-13.625,37.5],[-13.625,22.1666666],[-13.625,12.8333333],[-13.8333334,12.8333333],[-13.8333334,1.25],[-14.1145834,-5.8333334]],"sourceHandles":["A030","A037","A03A","A03B","AB18","AB19","AB20","AB21","AB38","AB39","AB49","AB4A"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":126,"id":"upper-exterior-1-north-column-126","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":125,"columnIndex":24,"outlineFt":[[-15.8854167,-5.8333334],[-16.1666667,1.25],[-16.1666667,12.8333333],[-16.1666667,22.1666666],[-15.9791667,22.1666666],[-15.9791667,37.5],[-16.1666667,37.5],[-16.1666667,46.8333333],[-17.1666667,46.8333333],[-17.1666667,37.5],[-17.3541667,37.5],[-17.3541667,22.1666666],[-17.1666667,22.1666666],[-17.1666667,12.8333333],[-17.1666667,1.25],[-17.4479167,-5.8333334]],"sourceHandles":["A038","A03F","A042","A043","AB5F","AB60","AB65","AB66","AB67","AB68"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":125,"id":"upper-exterior-1-north-column-125","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":124,"columnIndex":23,"outlineFt":[[-19.21875,-5.8333334],[-19.5,1.25],[-19.5,12.8333333],[-19.7083334,12.8333333],[-19.7083334,22.1666666],[-19.7083334,37.5],[-19.7083334,46.8333333],[-20.2916667,46.8333333],[-20.2916667,37.5],[-20.2916667,22.1666666],[-20.2916667,12.8333333],[-20.5,12.8333333],[-20.5,1.25],[-20.78125,-5.8333334]],"sourceHandles":["A040","A047","A04A","A04B","AB5B","AB5C","AB63","AB64","AB7B","AB7C","AB8C","AB8D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":124,"id":"upper-exterior-1-north-column-124","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":123,"columnIndex":22,"outlineFt":[[-22.5520834,-5.8333334],[-22.8333334,1.25],[-22.8333334,12.8333333],[-22.8333334,22.1666666],[-22.6458334,22.1666666],[-22.6458334,37.5],[-22.8333334,37.5],[-22.8333334,46.8333333],[-23.8333334,46.8333333],[-23.8333334,37.5],[-24.0208334,37.5],[-24.0208334,22.1666666],[-23.8333334,22.1666666],[-23.8333334,12.8333333],[-23.8333334,1.25],[-24.1145834,-5.8333334]],"sourceHandles":["A048","A04F","A052","A053","ABA2","ABA3","ABA8","ABA9","ABAA","ABAB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":123,"id":"upper-exterior-1-north-column-123","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":122,"columnIndex":21,"outlineFt":[[-25.8854167,-5.8333334],[-26.1666667,1.25],[-26.1666667,12.8333333],[-26.375,12.8333333],[-26.375,22.1666666],[-26.375,37.5],[-26.375,46.8333333],[-26.9583334,46.8333333],[-26.9583334,37.5],[-26.9583334,22.1666666],[-26.9583334,12.8333333],[-27.1666667,12.8333333],[-27.1666667,1.25],[-27.4479167,-5.8333334]],"sourceHandles":["A050","A057","A05A","A05B","AB9E","AB9F","ABA6","ABA7","ABBE","ABBF","ABCF","ABD0"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":122,"id":"upper-exterior-1-north-column-122","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":121,"columnIndex":20,"outlineFt":[[-29.21875,-5.8333334],[-29.5,1.25],[-29.5,12.8333333],[-29.5,22.1666666],[-29.3125,22.1666666],[-29.3125,37.5],[-29.5,37.5],[-29.5,46.8333333],[-30.5,46.8333333],[-30.5,37.5],[-30.6875,37.5],[-30.6875,22.1666666],[-30.5,22.1666666],[-30.5,12.8333333],[-30.5,1.25],[-30.78125,-5.8333334]],"sourceHandles":["A058","A05F","A062","A063","ABE5","ABE6","ABEB","ABEC","ABED","ABEE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":121,"id":"upper-exterior-1-north-column-121","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":120,"columnIndex":19,"outlineFt":[[-32.5520834,-5.8333334],[-32.8333334,1.25],[-32.8333334,12.8333333],[-33.0416667,12.8333333],[-33.0416667,22.1666666],[-33.0416667,37.5],[-33.0416667,46.8333333],[-33.625,46.8333333],[-33.625,37.5],[-33.625,22.1666666],[-33.625,12.8333333],[-33.8333334,12.8333333],[-33.8333334,1.25],[-34.1145834,-5.8333334]],"sourceHandles":["A060","A067","A06A","A06B","ABE1","ABE2","ABE9","ABEA","AC01","AC02","AC12","AC13"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":120,"id":"upper-exterior-1-north-column-120","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":119,"columnIndex":18,"outlineFt":[[-35.8854167,-5.8333334],[-36.1666667,1.25],[-36.1666667,12.8333333],[-36.1666667,22.1666666],[-35.9791667,22.1666666],[-35.9791667,37.5],[-36.1666667,37.5],[-36.1666667,46.8333333],[-37.1666667,46.8333333],[-37.1666667,37.5],[-37.3541667,37.5],[-37.3541667,22.1666666],[-37.1666667,22.1666666],[-37.1666667,12.8333333],[-37.1666667,1.25],[-37.4479167,-5.8333334]],"sourceHandles":["A068","A06F","A072","A073","AC27","AC28","AC2D","AC2E","AC2F","AC30"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":119,"id":"upper-exterior-1-north-column-119","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":118,"columnIndex":17,"outlineFt":[[-39.21875,-5.8333334],[-39.5,1.25],[-39.5,12.8333333],[-39.7083334,12.8333333],[-39.7083334,22.1666666],[-39.7083334,37.5],[-39.7083334,46.8333333],[-40.2916667,46.8333333],[-40.2916667,37.5],[-40.2916667,22.1666666],[-40.2916667,12.8333333],[-40.5,12.8333333],[-40.5,1.25],[-40.78125,-5.8333334]],"sourceHandles":["A070","A077","A07A","A07B","AC23","AC24","AC2B","AC2C","AC43","AC44","AC54","AC55"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":118,"id":"upper-exterior-1-north-column-118","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":117,"columnIndex":16,"outlineFt":[[-42.5520834,-5.8333334],[-42.8333334,1.25],[-42.8333334,12.8333333],[-42.8333334,22.1666666],[-42.6458334,22.1666666],[-42.6458334,37.5],[-42.8333334,37.5],[-42.8333334,46.8333333],[-43.8333334,46.8333333],[-43.8333334,37.5],[-44.0208334,37.5],[-44.0208334,22.1666666],[-43.8333334,22.1666666],[-43.8333334,12.8333333],[-43.8333334,1.25],[-44.1145834,-5.8333334]],"sourceHandles":["A078","A07F","A082","A083","AC69","AC6A","AC6F","AC70","AC71","AC72"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":117,"id":"upper-exterior-1-north-column-117","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":116,"columnIndex":15,"outlineFt":[[-45.8854167,-5.8333334],[-46.1666667,1.25],[-46.1666667,12.8333333],[-46.375,12.8333333],[-46.375,22.1666666],[-46.375,37.5],[-46.375,46.8333333],[-46.9583334,46.8333333],[-46.9583334,37.5],[-46.9583334,22.1666666],[-46.9583334,12.8333333],[-47.1666667,12.8333333],[-47.1666667,1.25],[-47.4479167,-5.8333334]],"sourceHandles":["A080","A087","A08A","A08B","AC65","AC66","AC6D","AC6E","AC85","AC86","AC96","AC97"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":116,"id":"upper-exterior-1-north-column-116","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":115,"columnIndex":14,"outlineFt":[[-49.21875,-5.8333334],[-49.5,1.25],[-49.5,12.8333333],[-49.5,22.1666666],[-49.3125,22.1666666],[-49.3125,37.5],[-49.5,37.5],[-49.5,46.8333333],[-50.5,46.8333333],[-50.5,37.5],[-50.6875,37.5],[-50.6875,22.1666666],[-50.5,22.1666666],[-50.5,12.8333333],[-50.5,1.25],[-50.78125,-5.8333334]],"sourceHandles":["A088","A08F","A092","A093","ACAB","ACAC","ACB1","ACB2","ACB3","ACB4"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":115,"id":"upper-exterior-1-north-column-115","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":114,"columnIndex":13,"outlineFt":[[-52.5520834,-5.8333334],[-52.8333334,1.25],[-52.8333334,12.8333333],[-53.0416667,12.8333333],[-53.0416667,22.1666666],[-53.0416667,37.5],[-53.0416667,46.8333333],[-53.625,46.8333333],[-53.625,37.5],[-53.625,22.1666666],[-53.625,12.8333333],[-53.8333334,12.8333333],[-53.8333334,1.25],[-54.1145834,-5.8333334]],"sourceHandles":["A090","A097","A09A","A09B","ACA7","ACA8","ACAF","ACB0","ACC7","ACC8","ACD8","ACD9"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":114,"id":"upper-exterior-1-north-column-114","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":113,"columnIndex":12,"outlineFt":[[-55.8854167,-5.8333334],[-56.1666667,1.25],[-56.1666667,12.8333333],[-56.1666667,22.1666666],[-55.9791667,22.1666666],[-55.9791667,37.5],[-56.1666667,37.5],[-56.1666667,46.8333333],[-57.1666667,46.8333333],[-57.1666667,37.5],[-57.3541667,37.5],[-57.3541667,22.1666666],[-57.1666667,22.1666666],[-57.1666667,12.8333333],[-57.1666667,1.25],[-57.4479167,-5.8333334]],"sourceHandles":["A098","A09F","A0A2","A0A3","ACED","ACEE","ACF3","ACF4","ACF5","ACF6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":113,"id":"upper-exterior-1-north-column-113","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":112,"columnIndex":11,"outlineFt":[[-59.21875,-5.8333334],[-59.5,1.25],[-59.5,12.8333333],[-59.7083334,12.8333333],[-59.7083334,22.1666666],[-59.7083334,37.5],[-59.7083334,46.8333333],[-60.2916667,46.8333333],[-60.2916667,37.5],[-60.2916667,22.1666666],[-60.2916667,12.8333333],[-60.5,12.8333333],[-60.5,1.25],[-60.78125,-5.8333334]],"sourceHandles":["A0A0","A0A7","A0AA","A0AB","ACE9","ACEA","ACF1","ACF2","AD09","AD0A","AD1A","AD1B"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":112,"id":"upper-exterior-1-north-column-112","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":111,"columnIndex":10,"outlineFt":[[-62.5520834,-5.8333334],[-62.8333334,1.25],[-62.8333334,12.8333333],[-62.8333334,22.1666666],[-62.6458334,22.1666666],[-62.6458334,37.5],[-62.8333334,37.5],[-62.8333334,46.8333333],[-63.8333334,46.8333333],[-63.8333334,37.5],[-64.0208334,37.5],[-64.0208334,22.1666666],[-63.8333334,22.1666666],[-63.8333334,12.8333333],[-63.8333334,1.25],[-64.1145834,-5.8333334]],"sourceHandles":["A0A8","A0AF","A0B2","A0B3","AD2F","AD30","AD35","AD36","AD37","AD38"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":111,"id":"upper-exterior-1-north-column-111","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":110,"columnIndex":9,"outlineFt":[[-65.8854167,-5.8333334],[-66.1666667,1.25],[-66.1666667,12.8333333],[-66.375,12.8333333],[-66.375,22.1666666],[-66.375,37.5],[-66.375,46.8333333],[-66.9583334,46.8333333],[-66.9583334,37.5],[-66.9583334,22.1666666],[-66.9583334,12.8333333],[-67.1666667,12.8333333],[-67.1666667,1.25],[-67.4479167,-5.8333334]],"sourceHandles":["A0B0","A0B7","A0BA","A0BB","AD2B","AD2C","AD33","AD34","AD4B","AD4C","AD5C","AD5D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":110,"id":"upper-exterior-1-north-column-110","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":109,"columnIndex":8,"outlineFt":[[-69.21875,-5.8333334],[-69.5,1.25],[-69.5,12.8333333],[-69.5,22.1666666],[-69.3125,22.1666666],[-69.3125,37.5],[-69.5,37.5],[-69.5,46.8333333],[-70.5,46.8333333],[-70.5,37.5],[-70.6875,37.5],[-70.6875,22.1666666],[-70.5,22.1666666],[-70.5,12.8333333],[-70.5,1.25],[-70.78125,-5.8333334]],"sourceHandles":["A0B8","A0BF","A0C2","A0C3","AD71","AD72","AD77","AD78","AD79","AD7A"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":109,"id":"upper-exterior-1-north-column-109","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":108,"columnIndex":7,"outlineFt":[[-72.5520834,-5.8333334],[-72.8333334,1.25],[-72.8333334,12.8333333],[-73.0416667,12.8333333],[-73.0416667,22.1666666],[-73.0416667,37.5],[-73.0416667,46.8333333],[-73.625,46.8333333],[-73.625,37.5],[-73.625,22.1666666],[-73.625,12.8333333],[-73.8333334,12.8333333],[-73.8333334,1.25],[-74.1145834,-5.8333334]],"sourceHandles":["A0C0","A0C7","A0CA","A0CB","AD6D","AD6E","AD75","AD76","AD8D","AD8E","AD9E","AD9F"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":108,"id":"upper-exterior-1-north-column-108","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":107,"columnIndex":6,"outlineFt":[[-75.8854167,-5.8333334],[-76.1666667,1.25],[-76.1666667,12.8333333],[-76.1666667,22.1666666],[-75.9791667,22.1666666],[-75.9791667,37.5],[-76.1666667,37.5],[-76.1666667,46.8333333],[-77.1666667,46.8333333],[-77.1666667,37.5],[-77.3541667,37.5],[-77.3541667,22.1666666],[-77.1666667,22.1666666],[-77.1666667,12.8333333],[-77.1666667,1.25],[-77.4479167,-5.8333334]],"sourceHandles":["A0C8","A0CF","A0D2","A0D3","ADB3","ADB4","ADB9","ADBA","ADBB","ADBC"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":107,"id":"upper-exterior-1-north-column-107","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":106,"columnIndex":5,"outlineFt":[[-79.21875,-5.8333334],[-79.5,1.25],[-79.5,12.8333333],[-79.7083334,12.8333333],[-79.7083334,22.1666666],[-79.7083334,37.5],[-79.7083334,46.8333333],[-80.2916667,46.8333333],[-80.2916667,37.5],[-80.2916667,22.1666666],[-80.2916667,12.8333333],[-80.5,12.8333333],[-80.5,1.25],[-80.78125,-5.8333334]],"sourceHandles":["A0D0","A0D7","A0DA","A0DB","ADAF","ADB0","ADB7","ADB8","ADCF","ADD0","ADE0","ADE1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":106,"id":"upper-exterior-1-north-column-106","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":105,"columnIndex":4,"outlineFt":[[-82.5520834,-5.8333334],[-82.8333334,1.25],[-82.8333334,12.8333333],[-82.8333334,22.1666666],[-82.6458334,22.1666666],[-82.6458334,37.5],[-82.8333334,37.5],[-82.8333334,46.8333333],[-83.8333334,46.8333333],[-83.8333334,37.5],[-84.0208334,37.5],[-84.0208334,22.1666666],[-83.8333334,22.1666666],[-83.8333334,12.8333333],[-83.8333334,1.25],[-84.1145834,-5.8333334]],"sourceHandles":["A0D8","A0DF","A0E2","A0E3","ADF5","ADF6","ADFB","ADFC","ADFD","ADFE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":105,"id":"upper-exterior-1-north-column-105","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":104,"columnIndex":3,"outlineFt":[[-85.8854167,-5.8333334],[-86.1666667,1.25],[-86.1666667,12.8333333],[-86.375,12.8333333],[-86.375,22.1666666],[-86.375,37.5],[-86.375,46.8333333],[-86.9583334,46.8333333],[-86.9583334,37.5],[-86.9583334,22.1666666],[-86.9583334,12.8333333],[-87.1666667,12.8333333],[-87.1666667,1.25],[-87.4479167,-5.8333334]],"sourceHandles":["A0E0","A0E7","A0EA","A0EB","ADF1","ADF2","ADF9","ADFA","AE11","AE12","AE22","AE23"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":104,"id":"upper-exterior-1-north-column-104","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":103,"columnIndex":2,"outlineFt":[[-89.21875,-5.8333334],[-89.5,1.25],[-89.5,12.8333333],[-89.5,22.1666666],[-89.3125,22.1666666],[-89.3125,37.5],[-89.5,37.5],[-89.5,46.8333333],[-90.5,46.8333333],[-90.5,37.5],[-90.6875,37.5],[-90.6875,22.1666666],[-90.5,22.1666666],[-90.5,12.8333333],[-90.5,1.25],[-90.78125,-5.8333334]],"sourceHandles":["A0E8","A0EF","A0F2","A0F3","AE37","AE38","AE3D","AE3E","AE3F","AE40"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":103,"id":"upper-exterior-1-north-column-103","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":102,"columnIndex":1,"outlineFt":[[-92.5520834,-5.8333334],[-92.8333334,1.25],[-92.8333334,12.8333333],[-93.0416667,12.8333333],[-93.0416667,22.1666666],[-93.0416667,37.5],[-93.0416667,46.8333333],[-93.625,46.8333333],[-93.625,37.5],[-93.625,22.1666666],[-93.625,12.8333333],[-93.8333334,12.8333333],[-93.8333334,1.25],[-94.1145834,-5.8333334]],"sourceHandles":["A0F0","A0F7","A0FA","A0FB","AE33","AE34","AE3B","AE3C","AE53","AE54","AE64","AE65"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":102,"id":"upper-exterior-1-north-column-102","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":101,"columnIndex":0,"outlineFt":[[-95.8854167,-5.8333334],[-96.1170343,-0.0],[-96.1666667,1.25],[-96.1668614,1.25],[-96.1668614,17.5],[-96.1668614,17.5049035],[-96.1668614,22.1666666],[-95.9791667,22.1666666],[-95.9791667,37.5],[-96.1668614,37.5],[-96.1668614,49.0833333],[-98.375,49.0833333],[-98.375,37.5],[-98.375,22.1666666],[-98.375,17.5049035],[-98.375,17.5],[-98.375,1.25],[-98.375,-0.0],[-98.375,-5.8333334]],"sourceHandles":["A0FE","A0FF","A100","A102","A104","A105","A106","AE7E","AE80"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":101,"id":"upper-exterior-1-north-column-101","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[93.8333333,1.25],[94.1145833,-5.8333334],[95.8854166,-5.8333334],[96.1170343,-0.0],[96.1666666,1.25]],"sourceHandles":["9EEF","9EF8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-0","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[90.5,1.25],[90.78125,-5.8333334],[92.5520833,-5.8333334],[92.8333333,1.25]],"sourceHandles":["9EB6","9F00"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-1","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[87.1666666,1.25],[87.4479166,-5.8333334],[89.21875,-5.8333334],[89.5,1.25]],"sourceHandles":["9F3E","9F41"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-2","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[83.8333333,1.25],[84.1145833,-5.8333334],[85.8854166,-5.8333334],[86.1666666,1.25]],"sourceHandles":["9F46","9F49"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-3","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[80.5,1.25],[80.78125,-5.8333334],[82.5520833,-5.8333334],[82.8333333,1.25]],"sourceHandles":["9F4E","9F51"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-4","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[77.1666666,1.25],[77.4479166,-5.8333334],[79.21875,-5.8333334],[79.5,1.25]],"sourceHandles":["9F56","9F59"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-5","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[73.8333333,1.25],[74.1145833,-5.8333334],[75.8854166,-5.8333334],[76.1666666,1.25]],"sourceHandles":["9F5E","9F61"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-6","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[70.5,1.25],[70.78125,-5.8333334],[72.5520833,-5.8333334],[72.8333333,1.25]],"sourceHandles":["9F66","9F69"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-7","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[67.1666666,1.25],[67.4479166,-5.8333334],[69.21875,-5.8333334],[69.5,1.25]],"sourceHandles":["9F6E","9F71"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-8","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[63.8333333,1.25],[64.1145833,-5.8333334],[65.8854166,-5.8333334],[66.1666666,1.25]],"sourceHandles":["9F76","9F79"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-9","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[60.5,1.25],[60.78125,-5.8333334],[62.5520833,-5.8333334],[62.8333333,1.25]],"sourceHandles":["9F7E","9F81"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-10","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[57.1666666,1.25],[57.4479166,-5.8333334],[59.21875,-5.8333334],[59.5,1.25]],"sourceHandles":["9F86","9F89"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-11","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[53.8333333,1.25],[54.1145833,-5.8333334],[55.8854166,-5.8333334],[56.1666666,1.25]],"sourceHandles":["9F8E","9F91"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-12","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[50.5,1.25],[50.78125,-5.8333334],[52.5520833,-5.8333334],[52.8333333,1.25]],"sourceHandles":["9F96","9F99"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-13","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[47.1666666,1.25],[47.4479166,-5.8333334],[49.21875,-5.8333334],[49.5,1.25]],"sourceHandles":["9F9E","9FA1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-14","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[43.8333333,1.25],[44.1145833,-5.8333334],[45.8854166,-5.8333334],[46.1666666,1.25]],"sourceHandles":["9FA6","9FA9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-15","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[40.5,1.25],[40.78125,-5.8333334],[42.5520833,-5.8333334],[42.8333333,1.25]],"sourceHandles":["9FAE","9FB1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-16","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[37.1666666,1.25],[37.4479166,-5.8333334],[39.21875,-5.8333334],[39.5,1.25]],"sourceHandles":["9FB6","9FB9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-17","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[33.8333333,1.25],[34.1145833,-5.8333334],[35.8854166,-5.8333334],[36.1666666,1.25]],"sourceHandles":["9FBE","9FC1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-18","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[30.5,1.25],[30.78125,-5.8333334],[32.5520833,-5.8333334],[32.8333333,1.25]],"sourceHandles":["9FC6","9FC9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-19","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[27.1666666,1.25],[27.4479166,-5.8333334],[29.21875,-5.8333334],[29.5,1.25]],"sourceHandles":["9FCE","9FD1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-20","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[23.8333333,1.25],[24.1145833,-5.8333334],[25.8854166,-5.8333334],[26.1666666,1.25]],"sourceHandles":["9FD6","9FD9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-21","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[20.5,1.25],[20.78125,-5.8333334],[22.5520833,-5.8333334],[22.8333333,1.25]],"sourceHandles":["9FDE","9FE1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-22","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[17.1666666,1.25],[17.4479166,-5.8333334],[19.21875,-5.8333334],[19.5,1.25]],"sourceHandles":["9FE6","9FE9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-23","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[13.8333333,1.25],[14.1145833,-5.8333334],[15.8854166,-5.8333334],[16.1666666,1.25]],"sourceHandles":["9FEE","9FF1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-24","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[10.5,1.25],[10.78125,-5.8333334],[12.5520833,-5.8333334],[12.8333333,1.25]],"sourceHandles":["9FF6","9FF9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-25","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[7.1666666,1.25],[7.4479166,-5.8333334],[9.21875,-5.8333334],[9.5,1.25]],"sourceHandles":["9FFE","A001"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-26","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[3.8333333,1.25],[4.1145833,-5.8333334],[5.8854166,-5.8333334],[6.1666666,1.25]],"sourceHandles":["A006","A009"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-27","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[0.5,1.25],[0.78125,-5.8333334],[2.5520833,-5.8333334],[2.8333333,1.25]],"sourceHandles":["A00E","A011"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-28","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[-2.8333334,1.25],[-2.5520834,-5.8333334],[-0.78125,-5.8333334],[-0.5,1.25]],"sourceHandles":["A016","A019"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-29","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[-6.1666667,1.25],[-5.8854167,-5.8333334],[-4.1145834,-5.8333334],[-3.8333334,1.25]],"sourceHandles":["A01E","A021"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-30","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[-9.5,1.25],[-9.21875,-5.8333334],[-7.4479167,-5.8333334],[-7.1666667,1.25]],"sourceHandles":["A026","A029"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-31","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[-12.8333334,1.25],[-12.5520834,-5.8333334],[-10.78125,-5.8333334],[-10.5,1.25]],"sourceHandles":["A02E","A031"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-32","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[-16.1666667,1.25],[-15.8854167,-5.8333334],[-14.1145834,-5.8333334],[-13.8333334,1.25]],"sourceHandles":["A036","A039"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-33","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[-19.5,1.25],[-19.21875,-5.8333334],[-17.4479167,-5.8333334],[-17.1666667,1.25]],"sourceHandles":["A03E","A041"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-34","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[-22.8333334,1.25],[-22.5520834,-5.8333334],[-20.78125,-5.8333334],[-20.5,1.25]],"sourceHandles":["A046","A049"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-35","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[-26.1666667,1.25],[-25.8854167,-5.8333334],[-24.1145834,-5.8333334],[-23.8333334,1.25]],"sourceHandles":["A04E","A051"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-36","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[-29.5,1.25],[-29.21875,-5.8333334],[-27.4479167,-5.8333334],[-27.1666667,1.25]],"sourceHandles":["A056","A059"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-37","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[-32.8333334,1.25],[-32.5520834,-5.8333334],[-30.78125,-5.8333334],[-30.5,1.25]],"sourceHandles":["A05E","A061"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-38","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[-36.1666667,1.25],[-35.8854167,-5.8333334],[-34.1145834,-5.8333334],[-33.8333334,1.25]],"sourceHandles":["A066","A069"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-39","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[-39.5,1.25],[-39.21875,-5.8333334],[-37.4479167,-5.8333334],[-37.1666667,1.25]],"sourceHandles":["A06E","A071"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-40","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[-42.8333334,1.25],[-42.5520834,-5.8333334],[-40.78125,-5.8333334],[-40.5,1.25]],"sourceHandles":["A076","A079"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-41","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[-46.1666667,1.25],[-45.8854167,-5.8333334],[-44.1145834,-5.8333334],[-43.8333334,1.25]],"sourceHandles":["A07E","A081"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-42","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[-49.5,1.25],[-49.21875,-5.8333334],[-47.4479167,-5.8333334],[-47.1666667,1.25]],"sourceHandles":["A086","A089"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-43","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[-52.8333334,1.25],[-52.5520834,-5.8333334],[-50.78125,-5.8333334],[-50.5,1.25]],"sourceHandles":["A08E","A091"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-44","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[-56.1666667,1.25],[-55.8854167,-5.8333334],[-54.1145834,-5.8333334],[-53.8333334,1.25]],"sourceHandles":["A096","A099"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-45","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[-59.5,1.25],[-59.21875,-5.8333334],[-57.4479167,-5.8333334],[-57.1666667,1.25]],"sourceHandles":["A09E","A0A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-46","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[-62.8333334,1.25],[-62.5520834,-5.8333334],[-60.78125,-5.8333334],[-60.5,1.25]],"sourceHandles":["A0A6","A0A9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-47","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[-66.1666667,1.25],[-65.8854167,-5.8333334],[-64.1145834,-5.8333334],[-63.8333334,1.25]],"sourceHandles":["A0AE","A0B1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-48","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[-69.5,1.25],[-69.21875,-5.8333334],[-67.4479167,-5.8333334],[-67.1666667,1.25]],"sourceHandles":["A0B6","A0B9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-49","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[-72.8333334,1.25],[-72.5520834,-5.8333334],[-70.78125,-5.8333334],[-70.5,1.25]],"sourceHandles":["A0BE","A0C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-50","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[-76.1666667,1.25],[-75.8854167,-5.8333334],[-74.1145834,-5.8333334],[-73.8333334,1.25]],"sourceHandles":["A0C6","A0C9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-51","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[-79.5,1.25],[-79.21875,-5.8333334],[-77.4479167,-5.8333334],[-77.1666667,1.25]],"sourceHandles":["A0CE","A0D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-52","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[-82.8333334,1.25],[-82.5520834,-5.8333334],[-80.78125,-5.8333334],[-80.5,1.25]],"sourceHandles":["A0D6","A0D9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-53","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[-86.1666667,1.25],[-85.8854167,-5.8333334],[-84.1145834,-5.8333334],[-83.8333334,1.25]],"sourceHandles":["A0DE","A0E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-54","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[-89.5,1.25],[-89.21875,-5.8333334],[-87.4479167,-5.8333334],[-87.1666667,1.25]],"sourceHandles":["A0E6","A0E9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-55","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[-92.8333334,1.25],[-92.5520834,-5.8333334],[-90.78125,-5.8333334],[-90.5,1.25]],"sourceHandles":["A0EE","A0F1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-56","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[-96.1666667,1.25],[-96.1170343,-0.0],[-95.8854167,-5.8333334],[-94.1145834,-5.8333334],[-93.8333334,1.25]],"sourceHandles":["A0F6","A0F9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-107-57","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[93.625,18.8333333],[93.625,12.8333333],[93.8333333,12.8333333],[96.1666666,12.8333333],[96.1666666,17.5],[96.1666666,18.8333333]],"sourceHandles":["A129","A12A","A156"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-0","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[90.5,18.8333333],[90.5,12.8333333],[92.8333333,12.8333333],[93.0416666,12.8333333],[93.0416666,18.8333333]],"sourceHandles":["A154","A155","A159"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-1","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[86.9583333,18.8333333],[86.9583333,12.8333333],[87.1666666,12.8333333],[89.5,12.8333333],[89.5,18.8333333]],"sourceHandles":["A152","A153","A15A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-2","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[83.8333333,18.8333333],[83.8333333,12.8333333],[86.1666666,12.8333333],[86.375,12.8333333],[86.375,18.8333333]],"sourceHandles":["A784","A785","A786"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-3","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[80.2916666,18.8333333],[80.2916666,12.8333333],[80.5,12.8333333],[82.8333333,12.8333333],[82.8333333,18.8333333]],"sourceHandles":["A782","A783","A787"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-4","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[77.1666666,18.8333333],[77.1666666,12.8333333],[79.5,12.8333333],[79.7083333,12.8333333],[79.7083333,18.8333333]],"sourceHandles":["A7C7","A7C8","A7C9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-5","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[73.625,18.8333333],[73.625,12.8333333],[73.8333333,12.8333333],[76.1666666,12.8333333],[76.1666666,18.8333333]],"sourceHandles":["A7C5","A7C6","A7CA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-6","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[70.5,18.8333333],[70.5,12.8333333],[72.8333333,12.8333333],[73.0416666,12.8333333],[73.0416666,18.8333333]],"sourceHandles":["A80A","A80B","A80C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-7","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[66.9583333,18.8333333],[66.9583333,12.8333333],[67.1666666,12.8333333],[69.5,12.8333333],[69.5,18.8333333]],"sourceHandles":["A808","A809","A80D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-8","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[63.8333333,18.8333333],[63.8333333,12.8333333],[66.1666666,12.8333333],[66.375,12.8333333],[66.375,18.8333333]],"sourceHandles":["A84D","A84E","A84F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-9","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[60.2916666,18.8333333],[60.2916666,12.8333333],[60.5,12.8333333],[62.8333333,12.8333333],[62.8333333,18.8333333]],"sourceHandles":["A84B","A84C","A850"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-10","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[57.1666666,18.8333333],[57.1666666,12.8333333],[59.5,12.8333333],[59.7083333,12.8333333],[59.7083333,18.8333333]],"sourceHandles":["A890","A891","A892"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-11","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[53.625,18.8333333],[53.625,12.8333333],[53.8333333,12.8333333],[56.1666666,12.8333333],[56.1666666,18.8333333]],"sourceHandles":["A88E","A88F","A893"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-12","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[50.5,18.8333333],[50.5,12.8333333],[52.8333333,12.8333333],[53.0416666,12.8333333],[53.0416666,18.8333333]],"sourceHandles":["A8D3","A8D4","A8D5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-13","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[46.9583333,18.8333333],[46.9583333,12.8333333],[47.1666666,12.8333333],[49.5,12.8333333],[49.5,18.8333333]],"sourceHandles":["A8D1","A8D2","A8D6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-14","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[43.8333333,18.8333333],[43.8333333,12.8333333],[46.1666666,12.8333333],[46.375,12.8333333],[46.375,18.8333333]],"sourceHandles":["A916","A917","A918"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-15","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[40.2916666,18.8333333],[40.2916666,12.8333333],[40.5,12.8333333],[42.8333333,12.8333333],[42.8333333,18.8333333]],"sourceHandles":["A914","A915","A919"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-16","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[37.1666666,18.8333333],[37.1666666,12.8333333],[39.5,12.8333333],[39.7083333,12.8333333],[39.7083333,18.8333333]],"sourceHandles":["A959","A95A","A95B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-17","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[33.625,18.8333333],[33.625,12.8333333],[33.8333333,12.8333333],[36.1666666,12.8333333],[36.1666666,18.8333333]],"sourceHandles":["A957","A958","A95C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-18","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[30.5,18.8333333],[30.5,12.8333333],[32.8333333,12.8333333],[33.0416666,12.8333333],[33.0416666,18.8333333]],"sourceHandles":["A99C","A99D","A99E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-19","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[26.9583333,18.8333333],[26.9583333,12.8333333],[27.1666666,12.8333333],[29.5,12.8333333],[29.5,18.8333333]],"sourceHandles":["A99A","A99B","A99F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-20","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[23.8333333,18.8333333],[23.8333333,12.8333333],[26.1666666,12.8333333],[26.375,12.8333333],[26.375,18.8333333]],"sourceHandles":["A9DF","A9E0","A9E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-21","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[20.2916666,18.8333333],[20.2916666,12.8333333],[20.5,12.8333333],[22.8333333,12.8333333],[22.8333333,18.8333333]],"sourceHandles":["A9DD","A9DE","A9E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-22","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[17.1666666,18.8333333],[17.1666666,12.8333333],[19.5,12.8333333],[19.7083333,12.8333333],[19.7083333,18.8333333]],"sourceHandles":["AA22","AA23","AA24"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-23","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[13.625,18.8333333],[13.625,12.8333333],[13.8333333,12.8333333],[16.1666666,12.8333333],[16.1666666,18.8333333]],"sourceHandles":["AA20","AA21","AA25"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-24","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[10.5,18.8333333],[10.5,12.8333333],[12.8333333,12.8333333],[13.0416666,12.8333333],[13.0416666,18.8333333]],"sourceHandles":["AA65","AA66","AA67"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-25","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[6.9583333,18.8333333],[6.9583333,12.8333333],[7.1666666,12.8333333],[9.5,12.8333333],[9.5,18.8333333]],"sourceHandles":["AA63","AA64","AA68"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-26","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[3.8333333,18.8333333],[3.8333333,12.8333333],[6.1666666,12.8333333],[6.375,12.8333333],[6.375,18.8333333]],"sourceHandles":["AAA8","AAA9","AAAA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-27","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[0.2916666,18.8333333],[0.2916666,12.8333333],[0.5,12.8333333],[2.8333333,12.8333333],[2.8333333,18.8333333]],"sourceHandles":["AAA6","AAA7","AAAB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-28","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[-2.8333334,18.8333333],[-2.8333334,12.8333333],[-0.5,12.8333333],[-0.2916667,12.8333333],[-0.2916667,18.8333333]],"sourceHandles":["AAEB","AAEC","AAED"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-29","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[-6.375,18.8333333],[-6.375,12.8333333],[-6.1666667,12.8333333],[-3.8333334,12.8333333],[-3.8333334,18.8333333]],"sourceHandles":["AAE9","AAEA","AAEE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-30","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[-9.5,18.8333333],[-9.5,12.8333333],[-7.1666667,12.8333333],[-6.9583334,12.8333333],[-6.9583334,18.8333333]],"sourceHandles":["AB2E","AB2F","AB30"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-31","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[-13.0416667,18.8333333],[-13.0416667,12.8333333],[-12.8333334,12.8333333],[-10.5,12.8333333],[-10.5,18.8333333]],"sourceHandles":["AB2C","AB2D","AB31"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-32","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[-16.1666667,18.8333333],[-16.1666667,12.8333333],[-13.8333334,12.8333333],[-13.625,12.8333333],[-13.625,18.8333333]],"sourceHandles":["AB71","AB72","AB73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-33","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[-19.7083334,18.8333333],[-19.7083334,12.8333333],[-19.5,12.8333333],[-17.1666667,12.8333333],[-17.1666667,18.8333333]],"sourceHandles":["AB6F","AB70","AB74"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-34","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[-22.8333334,18.8333333],[-22.8333334,12.8333333],[-20.5,12.8333333],[-20.2916667,12.8333333],[-20.2916667,18.8333333]],"sourceHandles":["ABB4","ABB5","ABB6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-35","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[-26.375,18.8333333],[-26.375,12.8333333],[-26.1666667,12.8333333],[-23.8333334,12.8333333],[-23.8333334,18.8333333]],"sourceHandles":["ABB2","ABB3","ABB7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-36","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[-29.5,18.8333333],[-29.5,12.8333333],[-27.1666667,12.8333333],[-26.9583334,12.8333333],[-26.9583334,18.8333333]],"sourceHandles":["ABF7","ABF8","ABF9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-37","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[-33.0416667,18.8333333],[-33.0416667,12.8333333],[-32.8333334,12.8333333],[-30.5,12.8333333],[-30.5,18.8333333]],"sourceHandles":["ABF5","ABF6","ABFA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-38","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[-36.1666667,18.8333333],[-36.1666667,12.8333333],[-33.8333334,12.8333333],[-33.625,12.8333333],[-33.625,18.8333333]],"sourceHandles":["AC39","AC3A","AC3B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-39","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[-39.7083334,18.8333333],[-39.7083334,12.8333333],[-39.5,12.8333333],[-37.1666667,12.8333333],[-37.1666667,18.8333333]],"sourceHandles":["AC37","AC38","AC3C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-40","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[-42.8333334,18.8333333],[-42.8333334,12.8333333],[-40.5,12.8333333],[-40.2916667,12.8333333],[-40.2916667,18.8333333]],"sourceHandles":["AC7B","AC7C","AC7D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-41","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[-46.375,18.8333333],[-46.375,12.8333333],[-46.1666667,12.8333333],[-43.8333334,12.8333333],[-43.8333334,18.8333333]],"sourceHandles":["AC79","AC7A","AC7E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-42","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[-49.5,18.8333333],[-49.5,12.8333333],[-47.1666667,12.8333333],[-46.9583334,12.8333333],[-46.9583334,18.8333333]],"sourceHandles":["ACBD","ACBE","ACBF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-43","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[-53.0416667,18.8333333],[-53.0416667,12.8333333],[-52.8333334,12.8333333],[-50.5,12.8333333],[-50.5,18.8333333]],"sourceHandles":["ACBB","ACBC","ACC0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-44","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[-56.1666667,18.8333333],[-56.1666667,12.8333333],[-53.8333334,12.8333333],[-53.625,12.8333333],[-53.625,18.8333333]],"sourceHandles":["ACFF","AD00","AD01"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-45","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[-59.7083334,18.8333333],[-59.7083334,12.8333333],[-59.5,12.8333333],[-57.1666667,12.8333333],[-57.1666667,18.8333333]],"sourceHandles":["ACFD","ACFE","AD02"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-46","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[-62.8333334,18.8333333],[-62.8333334,12.8333333],[-60.5,12.8333333],[-60.2916667,12.8333333],[-60.2916667,18.8333333]],"sourceHandles":["AD41","AD42","AD43"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-47","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[-66.375,18.8333333],[-66.375,12.8333333],[-66.1666667,12.8333333],[-63.8333334,12.8333333],[-63.8333334,18.8333333]],"sourceHandles":["AD3F","AD40","AD44"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-48","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[-69.5,18.8333333],[-69.5,12.8333333],[-67.1666667,12.8333333],[-66.9583334,12.8333333],[-66.9583334,18.8333333]],"sourceHandles":["AD83","AD84","AD85"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-49","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[-73.0416667,18.8333333],[-73.0416667,12.8333333],[-72.8333334,12.8333333],[-70.5,12.8333333],[-70.5,18.8333333]],"sourceHandles":["AD81","AD82","AD86"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-50","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[-76.1666667,18.8333333],[-76.1666667,12.8333333],[-73.8333334,12.8333333],[-73.625,12.8333333],[-73.625,18.8333333]],"sourceHandles":["ADC5","ADC6","ADC7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-51","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[-79.7083334,18.8333333],[-79.7083334,12.8333333],[-79.5,12.8333333],[-77.1666667,12.8333333],[-77.1666667,18.8333333]],"sourceHandles":["ADC3","ADC4","ADC8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-52","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[-82.8333334,18.8333333],[-82.8333334,12.8333333],[-80.5,12.8333333],[-80.2916667,12.8333333],[-80.2916667,18.8333333]],"sourceHandles":["AE07","AE08","AE09"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-53","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[-86.375,18.8333333],[-86.375,12.8333333],[-86.1666667,12.8333333],[-83.8333334,12.8333333],[-83.8333334,18.8333333]],"sourceHandles":["AE05","AE06","AE0A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-54","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[-89.5,18.8333333],[-89.5,12.8333333],[-87.1666667,12.8333333],[-86.9583334,12.8333333],[-86.9583334,18.8333333]],"sourceHandles":["AE49","AE4A","AE4B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-55","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[-93.0416667,18.8333333],[-93.0416667,12.8333333],[-92.8333334,12.8333333],[-90.5,12.8333333],[-90.5,18.8333333]],"sourceHandles":["AE47","AE48","AE4C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-56","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[-96.1668614,18.8333333],[-96.1668614,17.5049035],[-96.1668614,17.5],[-96.1668614,12.8333333],[-93.8333334,12.8333333],[-93.625,12.8333333],[-93.625,18.8333333]],"sourceHandles":["AE83","AE84","AE85"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-108-57","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[93.625,46.8333333],[93.625,39.5833333],[96.1666666,39.5833333],[96.1666666,46.8333333]],"sourceHandles":["A17F","A1A3","B297"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-0","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[90.5,46.8333333],[90.5,39.5833333],[93.0416666,39.5833333],[93.0416666,46.8333333]],"sourceHandles":["A19C","A1A4","A1A5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-1","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[86.9583333,46.8333333],[86.9583333,39.5833333],[89.5,39.5833333],[89.5,46.8333333]],"sourceHandles":["A19D","A1A6","A1A7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-2","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[83.8333333,46.8333333],[83.8333333,39.5833333],[86.375,39.5833333],[86.375,46.8333333]],"sourceHandles":["A1A8","A78C","B227"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-3","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[80.2916666,46.8333333],[80.2916666,39.5833333],[82.8333333,39.5833333],[82.8333333,46.8333333]],"sourceHandles":["A78D","B228","B229"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-4","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[77.1666666,46.8333333],[77.1666666,39.5833333],[79.7083333,39.5833333],[79.7083333,46.8333333]],"sourceHandles":["A7CF","B22A","B22B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-5","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[73.625,46.8333333],[73.625,39.5833333],[76.1666666,39.5833333],[76.1666666,46.8333333]],"sourceHandles":["A7D0","B22C","B22D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-6","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[70.5,46.8333333],[70.5,39.5833333],[73.0416666,39.5833333],[73.0416666,46.8333333]],"sourceHandles":["A812","B22E","B22F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-7","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[66.9583333,46.8333333],[66.9583333,39.5833333],[69.5,39.5833333],[69.5,46.8333333]],"sourceHandles":["A813","B230","B231"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-8","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[63.8333333,46.8333333],[63.8333333,39.5833333],[66.375,39.5833333],[66.375,46.8333333]],"sourceHandles":["A855","B232","B233"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-9","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[60.2916666,46.8333333],[60.2916666,39.5833333],[62.8333333,39.5833333],[62.8333333,46.8333333]],"sourceHandles":["A856","B234","B235"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-10","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[57.1666666,46.8333333],[57.1666666,39.5833333],[59.7083333,39.5833333],[59.7083333,46.8333333]],"sourceHandles":["A898","B236","B237"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-11","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[53.625,46.8333333],[53.625,39.5833333],[56.1666666,39.5833333],[56.1666666,46.8333333]],"sourceHandles":["A899","B238","B239"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-12","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[50.5,46.8333333],[50.5,39.5833333],[53.0416666,39.5833333],[53.0416666,46.8333333]],"sourceHandles":["A8DB","B23A","B23B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-13","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[46.9583333,46.8333333],[46.9583333,39.5833333],[49.5,39.5833333],[49.5,46.8333333]],"sourceHandles":["A8DC","B23C","B23D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-14","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[43.8333333,46.8333333],[43.8333333,39.5833333],[46.375,39.5833333],[46.375,46.8333333]],"sourceHandles":["A91E","B23E","B23F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-15","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[40.2916666,46.8333333],[40.2916666,39.5833333],[42.8333333,39.5833333],[42.8333333,46.8333333]],"sourceHandles":["A91F","B240","B241"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-16","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[37.1666666,46.8333333],[37.1666666,39.5833333],[39.7083333,39.5833333],[39.7083333,46.8333333]],"sourceHandles":["A961","B242","B243"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-17","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[33.625,46.8333333],[33.625,39.5833333],[36.1666666,39.5833333],[36.1666666,46.8333333]],"sourceHandles":["A962","B244","B245"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-18","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[30.5,46.8333333],[30.5,39.5833333],[33.0416666,39.5833333],[33.0416666,46.8333333]],"sourceHandles":["A9A4","B246","B247"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-19","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[26.9583333,46.8333333],[26.9583333,39.5833333],[29.5,39.5833333],[29.5,46.8333333]],"sourceHandles":["A9A5","B248","B249"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-20","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[23.8333333,46.8333333],[23.8333333,39.5833333],[26.375,39.5833333],[26.375,46.8333333]],"sourceHandles":["A9E7","B24A","B24B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-21","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[20.2916666,46.8333333],[20.2916666,39.5833333],[22.8333333,39.5833333],[22.8333333,46.8333333]],"sourceHandles":["A9E8","B24C","B24D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-22","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[17.1666666,46.8333333],[17.1666666,39.5833333],[19.7083333,39.5833333],[19.7083333,46.8333333]],"sourceHandles":["AA2A","B24E","B24F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-23","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[13.625,46.8333333],[13.625,39.5833333],[16.1666666,39.5833333],[16.1666666,46.8333333]],"sourceHandles":["AA2B","B250","B251"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-24","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[10.5,46.8333333],[10.5,39.5833333],[13.0416666,39.5833333],[13.0416666,46.8333333]],"sourceHandles":["AA6D","B252","B253"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-25","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[6.9583333,46.8333333],[6.9583333,39.5833333],[9.5,39.5833333],[9.5,46.8333333]],"sourceHandles":["AA6E","B254","B255"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-26","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[3.8333333,46.8333333],[3.8333333,39.5833333],[6.375,39.5833333],[6.375,46.8333333]],"sourceHandles":["AAB0","B256","B257"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-27","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[0.2916666,46.8333333],[0.2916666,39.5833333],[2.8333333,39.5833333],[2.8333333,46.8333333]],"sourceHandles":["AAB1","B258","B259"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-28","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[-2.8333334,46.8333333],[-2.8333334,39.5833333],[-0.2916667,39.5833333],[-0.2916667,46.8333333]],"sourceHandles":["AAF3","B25A","B25B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-29","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[-6.375,46.8333333],[-6.375,39.5833333],[-3.8333334,39.5833333],[-3.8333334,46.8333333]],"sourceHandles":["AAF4","B25C","B25D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-30","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[-9.5,46.8333333],[-9.5,39.5833333],[-6.9583334,39.5833333],[-6.9583334,46.8333333]],"sourceHandles":["AB36","B25E","B25F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-31","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[-13.0416667,46.8333333],[-13.0416667,39.5833333],[-10.5,39.5833333],[-10.5,46.8333333]],"sourceHandles":["AB37","B260","B261"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-32","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[-16.1666667,46.8333333],[-16.1666667,39.5833333],[-13.625,39.5833333],[-13.625,46.8333333]],"sourceHandles":["AB79","B262","B263"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-33","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[-19.7083334,46.8333333],[-19.7083334,39.5833333],[-17.1666667,39.5833333],[-17.1666667,46.8333333]],"sourceHandles":["AB7A","B264","B265"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-34","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[-22.8333334,46.8333333],[-22.8333334,39.5833333],[-20.2916667,39.5833333],[-20.2916667,46.8333333]],"sourceHandles":["ABBC","B266","B267"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-35","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[-26.375,46.8333333],[-26.375,39.5833333],[-23.8333334,39.5833333],[-23.8333334,46.8333333]],"sourceHandles":["ABBD","B268","B269"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-36","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[-29.5,46.8333333],[-29.5,39.5833333],[-26.9583334,39.5833333],[-26.9583334,46.8333333]],"sourceHandles":["ABFF","B26A","B26B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-37","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[-33.0416667,46.8333333],[-33.0416667,39.5833333],[-30.5,39.5833333],[-30.5,46.8333333]],"sourceHandles":["AC00","B26C","B26D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-38","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[-36.1666667,46.8333333],[-36.1666667,39.5833333],[-33.625,39.5833333],[-33.625,46.8333333]],"sourceHandles":["AC41","B26E","B26F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-39","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[-39.7083334,46.8333333],[-39.7083334,39.5833333],[-37.1666667,39.5833333],[-37.1666667,46.8333333]],"sourceHandles":["AC42","B270","B271"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-40","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[-42.8333334,46.8333333],[-42.8333334,39.5833333],[-40.2916667,39.5833333],[-40.2916667,46.8333333]],"sourceHandles":["AC83","B272","B273"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-41","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[-46.375,46.8333333],[-46.375,39.5833333],[-43.8333334,39.5833333],[-43.8333334,46.8333333]],"sourceHandles":["AC84","B274","B275"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-42","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[-49.5,46.8333333],[-49.5,39.5833333],[-46.9583334,39.5833333],[-46.9583334,46.8333333]],"sourceHandles":["ACC5","B276","B277"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-43","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[-53.0416667,46.8333333],[-53.0416667,39.5833333],[-50.5,39.5833333],[-50.5,46.8333333]],"sourceHandles":["ACC6","B278","B279"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-44","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[-56.1666667,46.8333333],[-56.1666667,39.5833333],[-53.625,39.5833333],[-53.625,46.8333333]],"sourceHandles":["AD07","B27A","B27B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-45","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[-59.7083334,46.8333333],[-59.7083334,39.5833333],[-57.1666667,39.5833333],[-57.1666667,46.8333333]],"sourceHandles":["AD08","B27C","B27D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-46","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[-62.8333334,46.8333333],[-62.8333334,39.5833333],[-60.2916667,39.5833333],[-60.2916667,46.8333333]],"sourceHandles":["AD49","B27E","B27F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-47","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[-66.375,46.8333333],[-66.375,39.5833333],[-63.8333334,39.5833333],[-63.8333334,46.8333333]],"sourceHandles":["AD4A","B280","B281"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-48","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[-69.5,46.8333333],[-69.5,39.5833333],[-66.9583334,39.5833333],[-66.9583334,46.8333333]],"sourceHandles":["AD8B","B282","B283"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-49","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[-73.0416667,46.8333333],[-73.0416667,39.5833333],[-70.5,39.5833333],[-70.5,46.8333333]],"sourceHandles":["AD8C","B284","B285"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-50","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[-76.1666667,46.8333333],[-76.1666667,39.5833333],[-73.625,39.5833333],[-73.625,46.8333333]],"sourceHandles":["ADCD","B286","B287"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-51","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[-79.7083334,46.8333333],[-79.7083334,39.5833333],[-77.1666667,39.5833333],[-77.1666667,46.8333333]],"sourceHandles":["ADCE","B288","B289"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-52","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[-82.8333334,46.8333333],[-82.8333334,39.5833333],[-80.2916667,39.5833333],[-80.2916667,46.8333333]],"sourceHandles":["AE0F","B28A","B28B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-53","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[-86.375,46.8333333],[-86.375,39.5833333],[-83.8333334,39.5833333],[-83.8333334,46.8333333]],"sourceHandles":["AE10","B28C","B28D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-54","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[-89.5,46.8333333],[-89.5,39.5833333],[-86.9583334,39.5833333],[-86.9583334,46.8333333]],"sourceHandles":["AE51","B28E","B28F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-55","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[-93.0416667,46.8333333],[-93.0416667,39.5833333],[-90.5,39.5833333],[-90.5,46.8333333]],"sourceHandles":["AE52","B290","B291"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-56","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[-96.1668614,46.8333333],[-96.1668614,39.5833333],[-93.625,39.5833333],[-93.625,46.8333333]],"sourceHandles":["B292","B293"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-north-spandrel-110-57","tower":1,"face":"north","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":259,"columnIndex":58,"outlineFt":[[98.375,-5.8333334],[98.375,-0.0],[98.375,1.25],[98.375,17.5],[98.375,22.1666666],[98.375,37.5],[98.375,49.0833333],[96.1666666,49.0833333],[96.1666666,37.5],[95.9791666,37.5],[95.9791666,22.1666666],[96.1666666,22.1666666],[96.1666666,17.5],[96.1666666,1.25],[96.1170343,-0.0],[95.8854166,-5.8333334]],"sourceHandles":["9F05","9F07","9F0E","9F0F","9F13","AE76","AE77","AE7D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":159,"id":"upper-exterior-2-north-column-259","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":258,"columnIndex":57,"outlineFt":[[94.1145833,-5.8333334],[93.8333333,1.25],[93.8333333,12.8333333],[93.625,12.8333333],[93.625,22.1666666],[93.625,37.5],[93.625,46.8333333],[93.0416666,46.8333333],[93.0416666,37.5],[93.0416666,22.1666666],[93.0416666,12.8333333],[92.8333333,12.8333333],[92.8333333,1.25],[92.5520833,-5.8333334]],"sourceHandles":["9EF9","9EFB","9F02","9F03","A149","A14A","A14D","A14E","A19E","A19F","A67C","A67D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":158,"id":"upper-exterior-2-north-column-258","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":257,"columnIndex":56,"outlineFt":[[90.78125,-5.8333334],[90.5,1.25],[90.5,12.8333333],[90.5,22.1666666],[90.6875,22.1666666],[90.6875,37.5],[90.5,37.5],[90.5,46.8333333],[89.5,46.8333333],[89.5,37.5],[89.3125,37.5],[89.3125,22.1666666],[89.5,22.1666666],[89.5,12.8333333],[89.5,1.25],[89.21875,-5.8333334]],"sourceHandles":["9EFF","9F3F","9F42","9F43","A12F","A130","A13B","A13C","A13D","A13E"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":157,"id":"upper-exterior-2-north-column-257","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":256,"columnIndex":55,"outlineFt":[[87.4479166,-5.8333334],[87.1666666,1.25],[87.1666666,12.8333333],[86.9583333,12.8333333],[86.9583333,22.1666666],[86.9583333,37.5],[86.9583333,46.8333333],[86.375,46.8333333],[86.375,37.5],[86.375,22.1666666],[86.375,12.8333333],[86.1666666,12.8333333],[86.1666666,1.25],[85.8854166,-5.8333334]],"sourceHandles":["9F40","9F47","9F4A","9F4B","A127","A128","A138","A139","A1A0","A1A1","A672","A673"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":156,"id":"upper-exterior-2-north-column-256","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":255,"columnIndex":54,"outlineFt":[[84.1145833,-5.8333334],[83.8333333,1.25],[83.8333333,12.8333333],[83.8333333,22.1666666],[84.0208333,22.1666666],[84.0208333,37.5],[83.8333333,37.5],[83.8333333,46.8333333],[82.8333333,46.8333333],[82.8333333,37.5],[82.6458333,37.5],[82.6458333,22.1666666],[82.8333333,22.1666666],[82.8333333,12.8333333],[82.8333333,1.25],[82.5520833,-5.8333334]],"sourceHandles":["9F48","9F4F","9F52","9F53","A772","A773","A778","A779","A77A","A77B"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":155,"id":"upper-exterior-2-north-column-255","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":254,"columnIndex":53,"outlineFt":[[80.78125,-5.8333334],[80.5,1.25],[80.5,12.8333333],[80.2916666,12.8333333],[80.2916666,22.1666666],[80.2916666,37.5],[80.2916666,46.8333333],[79.7083333,46.8333333],[79.7083333,37.5],[79.7083333,22.1666666],[79.7083333,12.8333333],[79.5,12.8333333],[79.5,1.25],[79.21875,-5.8333334]],"sourceHandles":["9F50","9F57","9F5A","9F5B","A76E","A76F","A776","A777","A78E","A78F","A79F","A7A0"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":154,"id":"upper-exterior-2-north-column-254","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":253,"columnIndex":52,"outlineFt":[[77.4479166,-5.8333334],[77.1666666,1.25],[77.1666666,12.8333333],[77.1666666,22.1666666],[77.3541666,22.1666666],[77.3541666,37.5],[77.1666666,37.5],[77.1666666,46.8333333],[76.1666666,46.8333333],[76.1666666,37.5],[75.9791666,37.5],[75.9791666,22.1666666],[76.1666666,22.1666666],[76.1666666,12.8333333],[76.1666666,1.25],[75.8854166,-5.8333334]],"sourceHandles":["9F58","9F5F","9F62","9F63","A7B5","A7B6","A7BB","A7BC","A7BD","A7BE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":153,"id":"upper-exterior-2-north-column-253","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":252,"columnIndex":51,"outlineFt":[[74.1145833,-5.8333334],[73.8333333,1.25],[73.8333333,12.8333333],[73.625,12.8333333],[73.625,22.1666666],[73.625,37.5],[73.625,46.8333333],[73.0416666,46.8333333],[73.0416666,37.5],[73.0416666,22.1666666],[73.0416666,12.8333333],[72.8333333,12.8333333],[72.8333333,1.25],[72.5520833,-5.8333334]],"sourceHandles":["9F60","9F67","9F6A","9F6B","A7B1","A7B2","A7B9","A7BA","A7D1","A7D2","A7E2","A7E3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":152,"id":"upper-exterior-2-north-column-252","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":251,"columnIndex":50,"outlineFt":[[70.78125,-5.8333334],[70.5,1.25],[70.5,12.8333333],[70.5,22.1666666],[70.6875,22.1666666],[70.6875,37.5],[70.5,37.5],[70.5,46.8333333],[69.5,46.8333333],[69.5,37.5],[69.3125,37.5],[69.3125,22.1666666],[69.5,22.1666666],[69.5,12.8333333],[69.5,1.25],[69.21875,-5.8333334]],"sourceHandles":["9F68","9F6F","9F72","9F73","A7F8","A7F9","A7FE","A7FF","A800","A801"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":151,"id":"upper-exterior-2-north-column-251","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":250,"columnIndex":49,"outlineFt":[[67.4479166,-5.8333334],[67.1666666,1.25],[67.1666666,12.8333333],[66.9583333,12.8333333],[66.9583333,22.1666666],[66.9583333,37.5],[66.9583333,46.8333333],[66.375,46.8333333],[66.375,37.5],[66.375,22.1666666],[66.375,12.8333333],[66.1666666,12.8333333],[66.1666666,1.25],[65.8854166,-5.8333334]],"sourceHandles":["9F70","9F77","9F7A","9F7B","A7F4","A7F5","A7FC","A7FD","A814","A815","A825","A826"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":150,"id":"upper-exterior-2-north-column-250","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":249,"columnIndex":48,"outlineFt":[[64.1145833,-5.8333334],[63.8333333,1.25],[63.8333333,12.8333333],[63.8333333,22.1666666],[64.0208333,22.1666666],[64.0208333,37.5],[63.8333333,37.5],[63.8333333,46.8333333],[62.8333333,46.8333333],[62.8333333,37.5],[62.6458333,37.5],[62.6458333,22.1666666],[62.8333333,22.1666666],[62.8333333,12.8333333],[62.8333333,1.25],[62.5520833,-5.8333334]],"sourceHandles":["9F78","9F7F","9F82","9F83","A83B","A83C","A841","A842","A843","A844"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":149,"id":"upper-exterior-2-north-column-249","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":248,"columnIndex":47,"outlineFt":[[60.78125,-5.8333334],[60.5,1.25],[60.5,12.8333333],[60.2916666,12.8333333],[60.2916666,22.1666666],[60.2916666,37.5],[60.2916666,46.8333333],[59.7083333,46.8333333],[59.7083333,37.5],[59.7083333,22.1666666],[59.7083333,12.8333333],[59.5,12.8333333],[59.5,1.25],[59.21875,-5.8333334]],"sourceHandles":["9F80","9F87","9F8A","9F8B","A837","A838","A83F","A840","A857","A858","A868","A869"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":148,"id":"upper-exterior-2-north-column-248","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":247,"columnIndex":46,"outlineFt":[[57.4479166,-5.8333334],[57.1666666,1.25],[57.1666666,12.8333333],[57.1666666,22.1666666],[57.3541666,22.1666666],[57.3541666,37.5],[57.1666666,37.5],[57.1666666,46.8333333],[56.1666666,46.8333333],[56.1666666,37.5],[55.9791666,37.5],[55.9791666,22.1666666],[56.1666666,22.1666666],[56.1666666,12.8333333],[56.1666666,1.25],[55.8854166,-5.8333334]],"sourceHandles":["9F88","9F8F","9F92","9F93","A87E","A87F","A884","A885","A886","A887"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":147,"id":"upper-exterior-2-north-column-247","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":246,"columnIndex":45,"outlineFt":[[54.1145833,-5.8333334],[53.8333333,1.25],[53.8333333,12.8333333],[53.625,12.8333333],[53.625,22.1666666],[53.625,37.5],[53.625,46.8333333],[53.0416666,46.8333333],[53.0416666,37.5],[53.0416666,22.1666666],[53.0416666,12.8333333],[52.8333333,12.8333333],[52.8333333,1.25],[52.5520833,-5.8333334]],"sourceHandles":["9F90","9F97","9F9A","9F9B","A87A","A87B","A882","A883","A89A","A89B","A8AB","A8AC"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":146,"id":"upper-exterior-2-north-column-246","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":245,"columnIndex":44,"outlineFt":[[50.78125,-5.8333334],[50.5,1.25],[50.5,12.8333333],[50.5,22.1666666],[50.6875,22.1666666],[50.6875,37.5],[50.5,37.5],[50.5,46.8333333],[49.5,46.8333333],[49.5,37.5],[49.3125,37.5],[49.3125,22.1666666],[49.5,22.1666666],[49.5,12.8333333],[49.5,1.25],[49.21875,-5.8333334]],"sourceHandles":["9F98","9F9F","9FA2","9FA3","A8C1","A8C2","A8C7","A8C8","A8C9","A8CA"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":145,"id":"upper-exterior-2-north-column-245","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":244,"columnIndex":43,"outlineFt":[[47.4479166,-5.8333334],[47.1666666,1.25],[47.1666666,12.8333333],[46.9583333,12.8333333],[46.9583333,22.1666666],[46.9583333,37.5],[46.9583333,46.8333333],[46.375,46.8333333],[46.375,37.5],[46.375,22.1666666],[46.375,12.8333333],[46.1666666,12.8333333],[46.1666666,1.25],[45.8854166,-5.8333334]],"sourceHandles":["9FA0","9FA7","9FAA","9FAB","A8BD","A8BE","A8C5","A8C6","A8DD","A8DE","A8EE","A8EF"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":144,"id":"upper-exterior-2-north-column-244","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":243,"columnIndex":42,"outlineFt":[[44.1145833,-5.8333334],[43.8333333,1.25],[43.8333333,12.8333333],[43.8333333,22.1666666],[44.0208333,22.1666666],[44.0208333,37.5],[43.8333333,37.5],[43.8333333,46.8333333],[42.8333333,46.8333333],[42.8333333,37.5],[42.6458333,37.5],[42.6458333,22.1666666],[42.8333333,22.1666666],[42.8333333,12.8333333],[42.8333333,1.25],[42.5520833,-5.8333334]],"sourceHandles":["9FA8","9FAF","9FB2","9FB3","A904","A905","A90A","A90B","A90C","A90D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":143,"id":"upper-exterior-2-north-column-243","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":242,"columnIndex":41,"outlineFt":[[40.78125,-5.8333334],[40.5,1.25],[40.5,12.8333333],[40.2916666,12.8333333],[40.2916666,22.1666666],[40.2916666,37.5],[40.2916666,46.8333333],[39.7083333,46.8333333],[39.7083333,37.5],[39.7083333,22.1666666],[39.7083333,12.8333333],[39.5,12.8333333],[39.5,1.25],[39.21875,-5.8333334]],"sourceHandles":["9FB0","9FB7","9FBA","9FBB","A900","A901","A908","A909","A920","A921","A931","A932"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":142,"id":"upper-exterior-2-north-column-242","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":241,"columnIndex":40,"outlineFt":[[37.4479166,-5.8333334],[37.1666666,1.25],[37.1666666,12.8333333],[37.1666666,22.1666666],[37.3541666,22.1666666],[37.3541666,37.5],[37.1666666,37.5],[37.1666666,46.8333333],[36.1666666,46.8333333],[36.1666666,37.5],[35.9791666,37.5],[35.9791666,22.1666666],[36.1666666,22.1666666],[36.1666666,12.8333333],[36.1666666,1.25],[35.8854166,-5.8333334]],"sourceHandles":["9FB8","9FBF","9FC2","9FC3","A947","A948","A94D","A94E","A94F","A950"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":141,"id":"upper-exterior-2-north-column-241","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":240,"columnIndex":39,"outlineFt":[[34.1145833,-5.8333334],[33.8333333,1.25],[33.8333333,12.8333333],[33.625,12.8333333],[33.625,22.1666666],[33.625,37.5],[33.625,46.8333333],[33.0416666,46.8333333],[33.0416666,37.5],[33.0416666,22.1666666],[33.0416666,12.8333333],[32.8333333,12.8333333],[32.8333333,1.25],[32.5520833,-5.8333334]],"sourceHandles":["9FC0","9FC7","9FCA","9FCB","A943","A944","A94B","A94C","A963","A964","A974","A975"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":140,"id":"upper-exterior-2-north-column-240","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":239,"columnIndex":38,"outlineFt":[[30.78125,-5.8333334],[30.5,1.25],[30.5,12.8333333],[30.5,22.1666666],[30.6875,22.1666666],[30.6875,37.5],[30.5,37.5],[30.5,46.8333333],[29.5,46.8333333],[29.5,37.5],[29.3125,37.5],[29.3125,22.1666666],[29.5,22.1666666],[29.5,12.8333333],[29.5,1.25],[29.21875,-5.8333334]],"sourceHandles":["9FC8","9FCF","9FD2","9FD3","A98A","A98B","A990","A991","A992","A993"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":139,"id":"upper-exterior-2-north-column-239","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":238,"columnIndex":37,"outlineFt":[[27.4479166,-5.8333334],[27.1666666,1.25],[27.1666666,12.8333333],[26.9583333,12.8333333],[26.9583333,22.1666666],[26.9583333,37.5],[26.9583333,46.8333333],[26.375,46.8333333],[26.375,37.5],[26.375,22.1666666],[26.375,12.8333333],[26.1666666,12.8333333],[26.1666666,1.25],[25.8854166,-5.8333334]],"sourceHandles":["9FD0","9FD7","9FDA","9FDB","A986","A987","A98E","A98F","A9A6","A9A7","A9B7","A9B8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":138,"id":"upper-exterior-2-north-column-238","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":237,"columnIndex":36,"outlineFt":[[24.1145833,-5.8333334],[23.8333333,1.25],[23.8333333,12.8333333],[23.8333333,22.1666666],[24.0208333,22.1666666],[24.0208333,37.5],[23.8333333,37.5],[23.8333333,46.8333333],[22.8333333,46.8333333],[22.8333333,37.5],[22.6458333,37.5],[22.6458333,22.1666666],[22.8333333,22.1666666],[22.8333333,12.8333333],[22.8333333,1.25],[22.5520833,-5.8333334]],"sourceHandles":["9FD8","9FDF","9FE2","9FE3","A9CD","A9CE","A9D3","A9D4","A9D5","A9D6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":137,"id":"upper-exterior-2-north-column-237","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":236,"columnIndex":35,"outlineFt":[[20.78125,-5.8333334],[20.5,1.25],[20.5,12.8333333],[20.2916666,12.8333333],[20.2916666,22.1666666],[20.2916666,37.5],[20.2916666,46.8333333],[19.7083333,46.8333333],[19.7083333,37.5],[19.7083333,22.1666666],[19.7083333,12.8333333],[19.5,12.8333333],[19.5,1.25],[19.21875,-5.8333334]],"sourceHandles":["9FE0","9FE7","9FEA","9FEB","A9C9","A9CA","A9D1","A9D2","A9E9","A9EA","A9FA","A9FB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":136,"id":"upper-exterior-2-north-column-236","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":235,"columnIndex":34,"outlineFt":[[17.4479166,-5.8333334],[17.1666666,1.25],[17.1666666,12.8333333],[17.1666666,22.1666666],[17.3541666,22.1666666],[17.3541666,37.5],[17.1666666,37.5],[17.1666666,46.8333333],[16.1666666,46.8333333],[16.1666666,37.5],[15.9791666,37.5],[15.9791666,22.1666666],[16.1666666,22.1666666],[16.1666666,12.8333333],[16.1666666,1.25],[15.8854166,-5.8333334]],"sourceHandles":["9FE8","9FEF","9FF2","9FF3","AA10","AA11","AA16","AA17","AA18","AA19"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":135,"id":"upper-exterior-2-north-column-235","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":234,"columnIndex":33,"outlineFt":[[14.1145833,-5.8333334],[13.8333333,1.25],[13.8333333,12.8333333],[13.625,12.8333333],[13.625,22.1666666],[13.625,37.5],[13.625,46.8333333],[13.0416666,46.8333333],[13.0416666,37.5],[13.0416666,22.1666666],[13.0416666,12.8333333],[12.8333333,12.8333333],[12.8333333,1.25],[12.5520833,-5.8333334]],"sourceHandles":["9FF0","9FF7","9FFA","9FFB","AA0C","AA0D","AA14","AA15","AA2C","AA2D","AA3D","AA3E"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":134,"id":"upper-exterior-2-north-column-234","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":233,"columnIndex":32,"outlineFt":[[10.78125,-5.8333334],[10.5,1.25],[10.5,12.8333333],[10.5,22.1666666],[10.6875,22.1666666],[10.6875,37.5],[10.5,37.5],[10.5,46.8333333],[9.5,46.8333333],[9.5,37.5],[9.3125,37.5],[9.3125,22.1666666],[9.5,22.1666666],[9.5,12.8333333],[9.5,1.25],[9.21875,-5.8333334]],"sourceHandles":["9FF8","9FFF","A002","A003","AA53","AA54","AA59","AA5A","AA5B","AA5C"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":133,"id":"upper-exterior-2-north-column-233","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":232,"columnIndex":31,"outlineFt":[[7.4479166,-5.8333334],[7.1666666,1.25],[7.1666666,12.8333333],[6.9583333,12.8333333],[6.9583333,22.1666666],[6.9583333,37.5],[6.9583333,46.8333333],[6.375,46.8333333],[6.375,37.5],[6.375,22.1666666],[6.375,12.8333333],[6.1666666,12.8333333],[6.1666666,1.25],[5.8854166,-5.8333334]],"sourceHandles":["A000","A007","A00A","A00B","AA4F","AA50","AA57","AA58","AA6F","AA70","AA80","AA81"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":132,"id":"upper-exterior-2-north-column-232","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":231,"columnIndex":30,"outlineFt":[[4.1145833,-5.8333334],[3.8333333,1.25],[3.8333333,12.8333333],[3.8333333,22.1666666],[4.0208333,22.1666666],[4.0208333,37.5],[3.8333333,37.5],[3.8333333,46.8333333],[2.8333333,46.8333333],[2.8333333,37.5],[2.6458333,37.5],[2.6458333,22.1666666],[2.8333333,22.1666666],[2.8333333,12.8333333],[2.8333333,1.25],[2.5520833,-5.8333334]],"sourceHandles":["A008","A00F","A012","A013","AA96","AA97","AA9C","AA9D","AA9E","AA9F"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":131,"id":"upper-exterior-2-north-column-231","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":230,"columnIndex":29,"outlineFt":[[0.78125,-5.8333334],[0.5,1.25],[0.5,12.8333333],[0.2916666,12.8333333],[0.2916666,22.1666666],[0.2916666,37.5],[0.2916666,46.8333333],[-0.2916667,46.8333333],[-0.2916667,37.5],[-0.2916667,22.1666666],[-0.2916667,12.8333333],[-0.5,12.8333333],[-0.5,1.25],[-0.78125,-5.8333334]],"sourceHandles":["A010","A017","A01A","A01B","AA92","AA93","AA9A","AA9B","AAB2","AAB3","AAC3","AAC4"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":130,"id":"upper-exterior-2-north-column-230","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":229,"columnIndex":28,"outlineFt":[[-2.5520834,-5.8333334],[-2.8333334,1.25],[-2.8333334,12.8333333],[-2.8333334,22.1666666],[-2.6458334,22.1666666],[-2.6458334,37.5],[-2.8333334,37.5],[-2.8333334,46.8333333],[-3.8333334,46.8333333],[-3.8333334,37.5],[-4.0208334,37.5],[-4.0208334,22.1666666],[-3.8333334,22.1666666],[-3.8333334,12.8333333],[-3.8333334,1.25],[-4.1145834,-5.8333334]],"sourceHandles":["A018","A01F","A022","A023","AAD9","AADA","AADF","AAE0","AAE1","AAE2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":129,"id":"upper-exterior-2-north-column-229","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":228,"columnIndex":27,"outlineFt":[[-5.8854167,-5.8333334],[-6.1666667,1.25],[-6.1666667,12.8333333],[-6.375,12.8333333],[-6.375,22.1666666],[-6.375,37.5],[-6.375,46.8333333],[-6.9583334,46.8333333],[-6.9583334,37.5],[-6.9583334,22.1666666],[-6.9583334,12.8333333],[-7.1666667,12.8333333],[-7.1666667,1.25],[-7.4479167,-5.8333334]],"sourceHandles":["A020","A027","A02A","A02B","AAD5","AAD6","AADD","AADE","AAF5","AAF6","AB06","AB07"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":128,"id":"upper-exterior-2-north-column-228","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":227,"columnIndex":26,"outlineFt":[[-9.21875,-5.8333334],[-9.5,1.25],[-9.5,12.8333333],[-9.5,22.1666666],[-9.3125,22.1666666],[-9.3125,37.5],[-9.5,37.5],[-9.5,46.8333333],[-10.5,46.8333333],[-10.5,37.5],[-10.6875,37.5],[-10.6875,22.1666666],[-10.5,22.1666666],[-10.5,12.8333333],[-10.5,1.25],[-10.78125,-5.8333334]],"sourceHandles":["A028","A02F","A032","A033","AB1C","AB1D","AB22","AB23","AB24","AB25"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":127,"id":"upper-exterior-2-north-column-227","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":226,"columnIndex":25,"outlineFt":[[-12.5520834,-5.8333334],[-12.8333334,1.25],[-12.8333334,12.8333333],[-13.0416667,12.8333333],[-13.0416667,22.1666666],[-13.0416667,37.5],[-13.0416667,46.8333333],[-13.625,46.8333333],[-13.625,37.5],[-13.625,22.1666666],[-13.625,12.8333333],[-13.8333334,12.8333333],[-13.8333334,1.25],[-14.1145834,-5.8333334]],"sourceHandles":["A030","A037","A03A","A03B","AB18","AB19","AB20","AB21","AB38","AB39","AB49","AB4A"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":126,"id":"upper-exterior-2-north-column-226","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":225,"columnIndex":24,"outlineFt":[[-15.8854167,-5.8333334],[-16.1666667,1.25],[-16.1666667,12.8333333],[-16.1666667,22.1666666],[-15.9791667,22.1666666],[-15.9791667,37.5],[-16.1666667,37.5],[-16.1666667,46.8333333],[-17.1666667,46.8333333],[-17.1666667,37.5],[-17.3541667,37.5],[-17.3541667,22.1666666],[-17.1666667,22.1666666],[-17.1666667,12.8333333],[-17.1666667,1.25],[-17.4479167,-5.8333334]],"sourceHandles":["A038","A03F","A042","A043","AB5F","AB60","AB65","AB66","AB67","AB68"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":125,"id":"upper-exterior-2-north-column-225","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":224,"columnIndex":23,"outlineFt":[[-19.21875,-5.8333334],[-19.5,1.25],[-19.5,12.8333333],[-19.7083334,12.8333333],[-19.7083334,22.1666666],[-19.7083334,37.5],[-19.7083334,46.8333333],[-20.2916667,46.8333333],[-20.2916667,37.5],[-20.2916667,22.1666666],[-20.2916667,12.8333333],[-20.5,12.8333333],[-20.5,1.25],[-20.78125,-5.8333334]],"sourceHandles":["A040","A047","A04A","A04B","AB5B","AB5C","AB63","AB64","AB7B","AB7C","AB8C","AB8D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":124,"id":"upper-exterior-2-north-column-224","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":223,"columnIndex":22,"outlineFt":[[-22.5520834,-5.8333334],[-22.8333334,1.25],[-22.8333334,12.8333333],[-22.8333334,22.1666666],[-22.6458334,22.1666666],[-22.6458334,37.5],[-22.8333334,37.5],[-22.8333334,46.8333333],[-23.8333334,46.8333333],[-23.8333334,37.5],[-24.0208334,37.5],[-24.0208334,22.1666666],[-23.8333334,22.1666666],[-23.8333334,12.8333333],[-23.8333334,1.25],[-24.1145834,-5.8333334]],"sourceHandles":["A048","A04F","A052","A053","ABA2","ABA3","ABA8","ABA9","ABAA","ABAB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":123,"id":"upper-exterior-2-north-column-223","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":222,"columnIndex":21,"outlineFt":[[-25.8854167,-5.8333334],[-26.1666667,1.25],[-26.1666667,12.8333333],[-26.375,12.8333333],[-26.375,22.1666666],[-26.375,37.5],[-26.375,46.8333333],[-26.9583334,46.8333333],[-26.9583334,37.5],[-26.9583334,22.1666666],[-26.9583334,12.8333333],[-27.1666667,12.8333333],[-27.1666667,1.25],[-27.4479167,-5.8333334]],"sourceHandles":["A050","A057","A05A","A05B","AB9E","AB9F","ABA6","ABA7","ABBE","ABBF","ABCF","ABD0"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":122,"id":"upper-exterior-2-north-column-222","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":221,"columnIndex":20,"outlineFt":[[-29.21875,-5.8333334],[-29.5,1.25],[-29.5,12.8333333],[-29.5,22.1666666],[-29.3125,22.1666666],[-29.3125,37.5],[-29.5,37.5],[-29.5,46.8333333],[-30.5,46.8333333],[-30.5,37.5],[-30.6875,37.5],[-30.6875,22.1666666],[-30.5,22.1666666],[-30.5,12.8333333],[-30.5,1.25],[-30.78125,-5.8333334]],"sourceHandles":["A058","A05F","A062","A063","ABE5","ABE6","ABEB","ABEC","ABED","ABEE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":121,"id":"upper-exterior-2-north-column-221","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":220,"columnIndex":19,"outlineFt":[[-32.5520834,-5.8333334],[-32.8333334,1.25],[-32.8333334,12.8333333],[-33.0416667,12.8333333],[-33.0416667,22.1666666],[-33.0416667,37.5],[-33.0416667,46.8333333],[-33.625,46.8333333],[-33.625,37.5],[-33.625,22.1666666],[-33.625,12.8333333],[-33.8333334,12.8333333],[-33.8333334,1.25],[-34.1145834,-5.8333334]],"sourceHandles":["A060","A067","A06A","A06B","ABE1","ABE2","ABE9","ABEA","AC01","AC02","AC12","AC13"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":120,"id":"upper-exterior-2-north-column-220","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":219,"columnIndex":18,"outlineFt":[[-35.8854167,-5.8333334],[-36.1666667,1.25],[-36.1666667,12.8333333],[-36.1666667,22.1666666],[-35.9791667,22.1666666],[-35.9791667,37.5],[-36.1666667,37.5],[-36.1666667,46.8333333],[-37.1666667,46.8333333],[-37.1666667,37.5],[-37.3541667,37.5],[-37.3541667,22.1666666],[-37.1666667,22.1666666],[-37.1666667,12.8333333],[-37.1666667,1.25],[-37.4479167,-5.8333334]],"sourceHandles":["A068","A06F","A072","A073","AC27","AC28","AC2D","AC2E","AC2F","AC30"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":119,"id":"upper-exterior-2-north-column-219","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":218,"columnIndex":17,"outlineFt":[[-39.21875,-5.8333334],[-39.5,1.25],[-39.5,12.8333333],[-39.7083334,12.8333333],[-39.7083334,22.1666666],[-39.7083334,37.5],[-39.7083334,46.8333333],[-40.2916667,46.8333333],[-40.2916667,37.5],[-40.2916667,22.1666666],[-40.2916667,12.8333333],[-40.5,12.8333333],[-40.5,1.25],[-40.78125,-5.8333334]],"sourceHandles":["A070","A077","A07A","A07B","AC23","AC24","AC2B","AC2C","AC43","AC44","AC54","AC55"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":118,"id":"upper-exterior-2-north-column-218","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":217,"columnIndex":16,"outlineFt":[[-42.5520834,-5.8333334],[-42.8333334,1.25],[-42.8333334,12.8333333],[-42.8333334,22.1666666],[-42.6458334,22.1666666],[-42.6458334,37.5],[-42.8333334,37.5],[-42.8333334,46.8333333],[-43.8333334,46.8333333],[-43.8333334,37.5],[-44.0208334,37.5],[-44.0208334,22.1666666],[-43.8333334,22.1666666],[-43.8333334,12.8333333],[-43.8333334,1.25],[-44.1145834,-5.8333334]],"sourceHandles":["A078","A07F","A082","A083","AC69","AC6A","AC6F","AC70","AC71","AC72"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":117,"id":"upper-exterior-2-north-column-217","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":216,"columnIndex":15,"outlineFt":[[-45.8854167,-5.8333334],[-46.1666667,1.25],[-46.1666667,12.8333333],[-46.375,12.8333333],[-46.375,22.1666666],[-46.375,37.5],[-46.375,46.8333333],[-46.9583334,46.8333333],[-46.9583334,37.5],[-46.9583334,22.1666666],[-46.9583334,12.8333333],[-47.1666667,12.8333333],[-47.1666667,1.25],[-47.4479167,-5.8333334]],"sourceHandles":["A080","A087","A08A","A08B","AC65","AC66","AC6D","AC6E","AC85","AC86","AC96","AC97"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":116,"id":"upper-exterior-2-north-column-216","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":215,"columnIndex":14,"outlineFt":[[-49.21875,-5.8333334],[-49.5,1.25],[-49.5,12.8333333],[-49.5,22.1666666],[-49.3125,22.1666666],[-49.3125,37.5],[-49.5,37.5],[-49.5,46.8333333],[-50.5,46.8333333],[-50.5,37.5],[-50.6875,37.5],[-50.6875,22.1666666],[-50.5,22.1666666],[-50.5,12.8333333],[-50.5,1.25],[-50.78125,-5.8333334]],"sourceHandles":["A088","A08F","A092","A093","ACAB","ACAC","ACB1","ACB2","ACB3","ACB4"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":115,"id":"upper-exterior-2-north-column-215","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":214,"columnIndex":13,"outlineFt":[[-52.5520834,-5.8333334],[-52.8333334,1.25],[-52.8333334,12.8333333],[-53.0416667,12.8333333],[-53.0416667,22.1666666],[-53.0416667,37.5],[-53.0416667,46.8333333],[-53.625,46.8333333],[-53.625,37.5],[-53.625,22.1666666],[-53.625,12.8333333],[-53.8333334,12.8333333],[-53.8333334,1.25],[-54.1145834,-5.8333334]],"sourceHandles":["A090","A097","A09A","A09B","ACA7","ACA8","ACAF","ACB0","ACC7","ACC8","ACD8","ACD9"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":114,"id":"upper-exterior-2-north-column-214","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":213,"columnIndex":12,"outlineFt":[[-55.8854167,-5.8333334],[-56.1666667,1.25],[-56.1666667,12.8333333],[-56.1666667,22.1666666],[-55.9791667,22.1666666],[-55.9791667,37.5],[-56.1666667,37.5],[-56.1666667,46.8333333],[-57.1666667,46.8333333],[-57.1666667,37.5],[-57.3541667,37.5],[-57.3541667,22.1666666],[-57.1666667,22.1666666],[-57.1666667,12.8333333],[-57.1666667,1.25],[-57.4479167,-5.8333334]],"sourceHandles":["A098","A09F","A0A2","A0A3","ACED","ACEE","ACF3","ACF4","ACF5","ACF6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":113,"id":"upper-exterior-2-north-column-213","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":212,"columnIndex":11,"outlineFt":[[-59.21875,-5.8333334],[-59.5,1.25],[-59.5,12.8333333],[-59.7083334,12.8333333],[-59.7083334,22.1666666],[-59.7083334,37.5],[-59.7083334,46.8333333],[-60.2916667,46.8333333],[-60.2916667,37.5],[-60.2916667,22.1666666],[-60.2916667,12.8333333],[-60.5,12.8333333],[-60.5,1.25],[-60.78125,-5.8333334]],"sourceHandles":["A0A0","A0A7","A0AA","A0AB","ACE9","ACEA","ACF1","ACF2","AD09","AD0A","AD1A","AD1B"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":112,"id":"upper-exterior-2-north-column-212","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":211,"columnIndex":10,"outlineFt":[[-62.5520834,-5.8333334],[-62.8333334,1.25],[-62.8333334,12.8333333],[-62.8333334,22.1666666],[-62.6458334,22.1666666],[-62.6458334,37.5],[-62.8333334,37.5],[-62.8333334,46.8333333],[-63.8333334,46.8333333],[-63.8333334,37.5],[-64.0208334,37.5],[-64.0208334,22.1666666],[-63.8333334,22.1666666],[-63.8333334,12.8333333],[-63.8333334,1.25],[-64.1145834,-5.8333334]],"sourceHandles":["A0A8","A0AF","A0B2","A0B3","AD2F","AD30","AD35","AD36","AD37","AD38"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":111,"id":"upper-exterior-2-north-column-211","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":210,"columnIndex":9,"outlineFt":[[-65.8854167,-5.8333334],[-66.1666667,1.25],[-66.1666667,12.8333333],[-66.375,12.8333333],[-66.375,22.1666666],[-66.375,37.5],[-66.375,46.8333333],[-66.9583334,46.8333333],[-66.9583334,37.5],[-66.9583334,22.1666666],[-66.9583334,12.8333333],[-67.1666667,12.8333333],[-67.1666667,1.25],[-67.4479167,-5.8333334]],"sourceHandles":["A0B0","A0B7","A0BA","A0BB","AD2B","AD2C","AD33","AD34","AD4B","AD4C","AD5C","AD5D"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":110,"id":"upper-exterior-2-north-column-210","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":209,"columnIndex":8,"outlineFt":[[-69.21875,-5.8333334],[-69.5,1.25],[-69.5,12.8333333],[-69.5,22.1666666],[-69.3125,22.1666666],[-69.3125,37.5],[-69.5,37.5],[-69.5,46.8333333],[-70.5,46.8333333],[-70.5,37.5],[-70.6875,37.5],[-70.6875,22.1666666],[-70.5,22.1666666],[-70.5,12.8333333],[-70.5,1.25],[-70.78125,-5.8333334]],"sourceHandles":["A0B8","A0BF","A0C2","A0C3","AD71","AD72","AD77","AD78","AD79","AD7A"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":109,"id":"upper-exterior-2-north-column-209","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":208,"columnIndex":7,"outlineFt":[[-72.5520834,-5.8333334],[-72.8333334,1.25],[-72.8333334,12.8333333],[-73.0416667,12.8333333],[-73.0416667,22.1666666],[-73.0416667,37.5],[-73.0416667,46.8333333],[-73.625,46.8333333],[-73.625,37.5],[-73.625,22.1666666],[-73.625,12.8333333],[-73.8333334,12.8333333],[-73.8333334,1.25],[-74.1145834,-5.8333334]],"sourceHandles":["A0C0","A0C7","A0CA","A0CB","AD6D","AD6E","AD75","AD76","AD8D","AD8E","AD9E","AD9F"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":108,"id":"upper-exterior-2-north-column-208","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":207,"columnIndex":6,"outlineFt":[[-75.8854167,-5.8333334],[-76.1666667,1.25],[-76.1666667,12.8333333],[-76.1666667,22.1666666],[-75.9791667,22.1666666],[-75.9791667,37.5],[-76.1666667,37.5],[-76.1666667,46.8333333],[-77.1666667,46.8333333],[-77.1666667,37.5],[-77.3541667,37.5],[-77.3541667,22.1666666],[-77.1666667,22.1666666],[-77.1666667,12.8333333],[-77.1666667,1.25],[-77.4479167,-5.8333334]],"sourceHandles":["A0C8","A0CF","A0D2","A0D3","ADB3","ADB4","ADB9","ADBA","ADBB","ADBC"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":107,"id":"upper-exterior-2-north-column-207","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":206,"columnIndex":5,"outlineFt":[[-79.21875,-5.8333334],[-79.5,1.25],[-79.5,12.8333333],[-79.7083334,12.8333333],[-79.7083334,22.1666666],[-79.7083334,37.5],[-79.7083334,46.8333333],[-80.2916667,46.8333333],[-80.2916667,37.5],[-80.2916667,22.1666666],[-80.2916667,12.8333333],[-80.5,12.8333333],[-80.5,1.25],[-80.78125,-5.8333334]],"sourceHandles":["A0D0","A0D7","A0DA","A0DB","ADAF","ADB0","ADB7","ADB8","ADCF","ADD0","ADE0","ADE1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":106,"id":"upper-exterior-2-north-column-206","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":205,"columnIndex":4,"outlineFt":[[-82.5520834,-5.8333334],[-82.8333334,1.25],[-82.8333334,12.8333333],[-82.8333334,22.1666666],[-82.6458334,22.1666666],[-82.6458334,37.5],[-82.8333334,37.5],[-82.8333334,46.8333333],[-83.8333334,46.8333333],[-83.8333334,37.5],[-84.0208334,37.5],[-84.0208334,22.1666666],[-83.8333334,22.1666666],[-83.8333334,12.8333333],[-83.8333334,1.25],[-84.1145834,-5.8333334]],"sourceHandles":["A0D8","A0DF","A0E2","A0E3","ADF5","ADF6","ADFB","ADFC","ADFD","ADFE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":105,"id":"upper-exterior-2-north-column-205","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":204,"columnIndex":3,"outlineFt":[[-85.8854167,-5.8333334],[-86.1666667,1.25],[-86.1666667,12.8333333],[-86.375,12.8333333],[-86.375,22.1666666],[-86.375,37.5],[-86.375,46.8333333],[-86.9583334,46.8333333],[-86.9583334,37.5],[-86.9583334,22.1666666],[-86.9583334,12.8333333],[-87.1666667,12.8333333],[-87.1666667,1.25],[-87.4479167,-5.8333334]],"sourceHandles":["A0E0","A0E7","A0EA","A0EB","ADF1","ADF2","ADF9","ADFA","AE11","AE12","AE22","AE23"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":104,"id":"upper-exterior-2-north-column-204","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":203,"columnIndex":2,"outlineFt":[[-89.21875,-5.8333334],[-89.5,1.25],[-89.5,12.8333333],[-89.5,22.1666666],[-89.3125,22.1666666],[-89.3125,37.5],[-89.5,37.5],[-89.5,46.8333333],[-90.5,46.8333333],[-90.5,37.5],[-90.6875,37.5],[-90.6875,22.1666666],[-90.5,22.1666666],[-90.5,12.8333333],[-90.5,1.25],[-90.78125,-5.8333334]],"sourceHandles":["A0E8","A0EF","A0F2","A0F3","AE37","AE38","AE3D","AE3E","AE3F","AE40"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":103,"id":"upper-exterior-2-north-column-203","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":202,"columnIndex":1,"outlineFt":[[-92.5520834,-5.8333334],[-92.8333334,1.25],[-92.8333334,12.8333333],[-93.0416667,12.8333333],[-93.0416667,22.1666666],[-93.0416667,37.5],[-93.0416667,46.8333333],[-93.625,46.8333333],[-93.625,37.5],[-93.625,22.1666666],[-93.625,12.8333333],[-93.8333334,12.8333333],[-93.8333334,1.25],[-94.1145834,-5.8333334]],"sourceHandles":["A0F0","A0F7","A0FA","A0FB","AE33","AE34","AE3B","AE3C","AE53","AE54","AE64","AE65"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":102,"id":"upper-exterior-2-north-column-202","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":201,"columnIndex":0,"outlineFt":[[-95.8854167,-5.8333334],[-96.1170343,-0.0],[-96.1666667,1.25],[-96.1668614,1.25],[-96.1668614,17.5],[-96.1668614,17.5049035],[-96.1668614,22.1666666],[-95.9791667,22.1666666],[-95.9791667,37.5],[-96.1668614,37.5],[-96.1668614,49.0833333],[-98.375,49.0833333],[-98.375,37.5],[-98.375,22.1666666],[-98.375,17.5049035],[-98.375,17.5],[-98.375,1.25],[-98.375,-0.0],[-98.375,-5.8333334]],"sourceHandles":["A0FE","A0FF","A100","A102","A104","A105","A106","AE7E","AE80"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":101,"id":"upper-exterior-2-north-column-201","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[93.8333333,1.25],[94.1145833,-5.8333334],[95.8854166,-5.8333334],[96.1170343,-0.0],[96.1666666,1.25]],"sourceHandles":["9EEF","9EF8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-0","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[90.5,1.25],[90.78125,-5.8333334],[92.5520833,-5.8333334],[92.8333333,1.25]],"sourceHandles":["9EB6","9F00"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-1","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[87.1666666,1.25],[87.4479166,-5.8333334],[89.21875,-5.8333334],[89.5,1.25]],"sourceHandles":["9F3E","9F41"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-2","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[83.8333333,1.25],[84.1145833,-5.8333334],[85.8854166,-5.8333334],[86.1666666,1.25]],"sourceHandles":["9F46","9F49"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-3","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[80.5,1.25],[80.78125,-5.8333334],[82.5520833,-5.8333334],[82.8333333,1.25]],"sourceHandles":["9F4E","9F51"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-4","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[77.1666666,1.25],[77.4479166,-5.8333334],[79.21875,-5.8333334],[79.5,1.25]],"sourceHandles":["9F56","9F59"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-5","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[73.8333333,1.25],[74.1145833,-5.8333334],[75.8854166,-5.8333334],[76.1666666,1.25]],"sourceHandles":["9F5E","9F61"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-6","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[70.5,1.25],[70.78125,-5.8333334],[72.5520833,-5.8333334],[72.8333333,1.25]],"sourceHandles":["9F66","9F69"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-7","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[67.1666666,1.25],[67.4479166,-5.8333334],[69.21875,-5.8333334],[69.5,1.25]],"sourceHandles":["9F6E","9F71"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-8","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[63.8333333,1.25],[64.1145833,-5.8333334],[65.8854166,-5.8333334],[66.1666666,1.25]],"sourceHandles":["9F76","9F79"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-9","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[60.5,1.25],[60.78125,-5.8333334],[62.5520833,-5.8333334],[62.8333333,1.25]],"sourceHandles":["9F7E","9F81"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-10","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[57.1666666,1.25],[57.4479166,-5.8333334],[59.21875,-5.8333334],[59.5,1.25]],"sourceHandles":["9F86","9F89"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-11","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[53.8333333,1.25],[54.1145833,-5.8333334],[55.8854166,-5.8333334],[56.1666666,1.25]],"sourceHandles":["9F8E","9F91"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-12","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[50.5,1.25],[50.78125,-5.8333334],[52.5520833,-5.8333334],[52.8333333,1.25]],"sourceHandles":["9F96","9F99"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-13","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[47.1666666,1.25],[47.4479166,-5.8333334],[49.21875,-5.8333334],[49.5,1.25]],"sourceHandles":["9F9E","9FA1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-14","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[43.8333333,1.25],[44.1145833,-5.8333334],[45.8854166,-5.8333334],[46.1666666,1.25]],"sourceHandles":["9FA6","9FA9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-15","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[40.5,1.25],[40.78125,-5.8333334],[42.5520833,-5.8333334],[42.8333333,1.25]],"sourceHandles":["9FAE","9FB1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-16","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[37.1666666,1.25],[37.4479166,-5.8333334],[39.21875,-5.8333334],[39.5,1.25]],"sourceHandles":["9FB6","9FB9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-17","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[33.8333333,1.25],[34.1145833,-5.8333334],[35.8854166,-5.8333334],[36.1666666,1.25]],"sourceHandles":["9FBE","9FC1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-18","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[30.5,1.25],[30.78125,-5.8333334],[32.5520833,-5.8333334],[32.8333333,1.25]],"sourceHandles":["9FC6","9FC9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-19","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[27.1666666,1.25],[27.4479166,-5.8333334],[29.21875,-5.8333334],[29.5,1.25]],"sourceHandles":["9FCE","9FD1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-20","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[23.8333333,1.25],[24.1145833,-5.8333334],[25.8854166,-5.8333334],[26.1666666,1.25]],"sourceHandles":["9FD6","9FD9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-21","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[20.5,1.25],[20.78125,-5.8333334],[22.5520833,-5.8333334],[22.8333333,1.25]],"sourceHandles":["9FDE","9FE1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-22","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[17.1666666,1.25],[17.4479166,-5.8333334],[19.21875,-5.8333334],[19.5,1.25]],"sourceHandles":["9FE6","9FE9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-23","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[13.8333333,1.25],[14.1145833,-5.8333334],[15.8854166,-5.8333334],[16.1666666,1.25]],"sourceHandles":["9FEE","9FF1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-24","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[10.5,1.25],[10.78125,-5.8333334],[12.5520833,-5.8333334],[12.8333333,1.25]],"sourceHandles":["9FF6","9FF9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-25","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[7.1666666,1.25],[7.4479166,-5.8333334],[9.21875,-5.8333334],[9.5,1.25]],"sourceHandles":["9FFE","A001"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-26","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[3.8333333,1.25],[4.1145833,-5.8333334],[5.8854166,-5.8333334],[6.1666666,1.25]],"sourceHandles":["A006","A009"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-27","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[0.5,1.25],[0.78125,-5.8333334],[2.5520833,-5.8333334],[2.8333333,1.25]],"sourceHandles":["A00E","A011"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-28","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[-2.8333334,1.25],[-2.5520834,-5.8333334],[-0.78125,-5.8333334],[-0.5,1.25]],"sourceHandles":["A016","A019"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-29","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[-6.1666667,1.25],[-5.8854167,-5.8333334],[-4.1145834,-5.8333334],[-3.8333334,1.25]],"sourceHandles":["A01E","A021"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-30","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[-9.5,1.25],[-9.21875,-5.8333334],[-7.4479167,-5.8333334],[-7.1666667,1.25]],"sourceHandles":["A026","A029"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-31","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[-12.8333334,1.25],[-12.5520834,-5.8333334],[-10.78125,-5.8333334],[-10.5,1.25]],"sourceHandles":["A02E","A031"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-32","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[-16.1666667,1.25],[-15.8854167,-5.8333334],[-14.1145834,-5.8333334],[-13.8333334,1.25]],"sourceHandles":["A036","A039"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-33","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[-19.5,1.25],[-19.21875,-5.8333334],[-17.4479167,-5.8333334],[-17.1666667,1.25]],"sourceHandles":["A03E","A041"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-34","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[-22.8333334,1.25],[-22.5520834,-5.8333334],[-20.78125,-5.8333334],[-20.5,1.25]],"sourceHandles":["A046","A049"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-35","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[-26.1666667,1.25],[-25.8854167,-5.8333334],[-24.1145834,-5.8333334],[-23.8333334,1.25]],"sourceHandles":["A04E","A051"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-36","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[-29.5,1.25],[-29.21875,-5.8333334],[-27.4479167,-5.8333334],[-27.1666667,1.25]],"sourceHandles":["A056","A059"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-37","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[-32.8333334,1.25],[-32.5520834,-5.8333334],[-30.78125,-5.8333334],[-30.5,1.25]],"sourceHandles":["A05E","A061"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-38","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[-36.1666667,1.25],[-35.8854167,-5.8333334],[-34.1145834,-5.8333334],[-33.8333334,1.25]],"sourceHandles":["A066","A069"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-39","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[-39.5,1.25],[-39.21875,-5.8333334],[-37.4479167,-5.8333334],[-37.1666667,1.25]],"sourceHandles":["A06E","A071"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-40","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[-42.8333334,1.25],[-42.5520834,-5.8333334],[-40.78125,-5.8333334],[-40.5,1.25]],"sourceHandles":["A076","A079"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-41","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[-46.1666667,1.25],[-45.8854167,-5.8333334],[-44.1145834,-5.8333334],[-43.8333334,1.25]],"sourceHandles":["A07E","A081"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-42","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[-49.5,1.25],[-49.21875,-5.8333334],[-47.4479167,-5.8333334],[-47.1666667,1.25]],"sourceHandles":["A086","A089"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-43","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[-52.8333334,1.25],[-52.5520834,-5.8333334],[-50.78125,-5.8333334],[-50.5,1.25]],"sourceHandles":["A08E","A091"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-44","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[-56.1666667,1.25],[-55.8854167,-5.8333334],[-54.1145834,-5.8333334],[-53.8333334,1.25]],"sourceHandles":["A096","A099"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-45","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[-59.5,1.25],[-59.21875,-5.8333334],[-57.4479167,-5.8333334],[-57.1666667,1.25]],"sourceHandles":["A09E","A0A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-46","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[-62.8333334,1.25],[-62.5520834,-5.8333334],[-60.78125,-5.8333334],[-60.5,1.25]],"sourceHandles":["A0A6","A0A9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-47","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[-66.1666667,1.25],[-65.8854167,-5.8333334],[-64.1145834,-5.8333334],[-63.8333334,1.25]],"sourceHandles":["A0AE","A0B1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-48","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[-69.5,1.25],[-69.21875,-5.8333334],[-67.4479167,-5.8333334],[-67.1666667,1.25]],"sourceHandles":["A0B6","A0B9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-49","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[-72.8333334,1.25],[-72.5520834,-5.8333334],[-70.78125,-5.8333334],[-70.5,1.25]],"sourceHandles":["A0BE","A0C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-50","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[-76.1666667,1.25],[-75.8854167,-5.8333334],[-74.1145834,-5.8333334],[-73.8333334,1.25]],"sourceHandles":["A0C6","A0C9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-51","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[-79.5,1.25],[-79.21875,-5.8333334],[-77.4479167,-5.8333334],[-77.1666667,1.25]],"sourceHandles":["A0CE","A0D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-52","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[-82.8333334,1.25],[-82.5520834,-5.8333334],[-80.78125,-5.8333334],[-80.5,1.25]],"sourceHandles":["A0D6","A0D9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-53","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[-86.1666667,1.25],[-85.8854167,-5.8333334],[-84.1145834,-5.8333334],[-83.8333334,1.25]],"sourceHandles":["A0DE","A0E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-54","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[-89.5,1.25],[-89.21875,-5.8333334],[-87.4479167,-5.8333334],[-87.1666667,1.25]],"sourceHandles":["A0E6","A0E9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-55","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[-92.8333334,1.25],[-92.5520834,-5.8333334],[-90.78125,-5.8333334],[-90.5,1.25]],"sourceHandles":["A0EE","A0F1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-56","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[-96.1666667,1.25],[-96.1170343,-0.0],[-95.8854167,-5.8333334],[-94.1145834,-5.8333334],[-93.8333334,1.25]],"sourceHandles":["A0F6","A0F9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-107-57","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[93.625,18.8333333],[93.625,12.8333333],[93.8333333,12.8333333],[96.1666666,12.8333333],[96.1666666,17.5],[96.1666666,18.8333333]],"sourceHandles":["A129","A12A","A156"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-0","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[90.5,18.8333333],[90.5,12.8333333],[92.8333333,12.8333333],[93.0416666,12.8333333],[93.0416666,18.8333333]],"sourceHandles":["A154","A155","A159"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-1","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[86.9583333,18.8333333],[86.9583333,12.8333333],[87.1666666,12.8333333],[89.5,12.8333333],[89.5,18.8333333]],"sourceHandles":["A152","A153","A15A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-2","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[83.8333333,18.8333333],[83.8333333,12.8333333],[86.1666666,12.8333333],[86.375,12.8333333],[86.375,18.8333333]],"sourceHandles":["A784","A785","A786"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-3","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[80.2916666,18.8333333],[80.2916666,12.8333333],[80.5,12.8333333],[82.8333333,12.8333333],[82.8333333,18.8333333]],"sourceHandles":["A782","A783","A787"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-4","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[77.1666666,18.8333333],[77.1666666,12.8333333],[79.5,12.8333333],[79.7083333,12.8333333],[79.7083333,18.8333333]],"sourceHandles":["A7C7","A7C8","A7C9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-5","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[73.625,18.8333333],[73.625,12.8333333],[73.8333333,12.8333333],[76.1666666,12.8333333],[76.1666666,18.8333333]],"sourceHandles":["A7C5","A7C6","A7CA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-6","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[70.5,18.8333333],[70.5,12.8333333],[72.8333333,12.8333333],[73.0416666,12.8333333],[73.0416666,18.8333333]],"sourceHandles":["A80A","A80B","A80C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-7","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[66.9583333,18.8333333],[66.9583333,12.8333333],[67.1666666,12.8333333],[69.5,12.8333333],[69.5,18.8333333]],"sourceHandles":["A808","A809","A80D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-8","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[63.8333333,18.8333333],[63.8333333,12.8333333],[66.1666666,12.8333333],[66.375,12.8333333],[66.375,18.8333333]],"sourceHandles":["A84D","A84E","A84F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-9","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[60.2916666,18.8333333],[60.2916666,12.8333333],[60.5,12.8333333],[62.8333333,12.8333333],[62.8333333,18.8333333]],"sourceHandles":["A84B","A84C","A850"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-10","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[57.1666666,18.8333333],[57.1666666,12.8333333],[59.5,12.8333333],[59.7083333,12.8333333],[59.7083333,18.8333333]],"sourceHandles":["A890","A891","A892"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-11","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[53.625,18.8333333],[53.625,12.8333333],[53.8333333,12.8333333],[56.1666666,12.8333333],[56.1666666,18.8333333]],"sourceHandles":["A88E","A88F","A893"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-12","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[50.5,18.8333333],[50.5,12.8333333],[52.8333333,12.8333333],[53.0416666,12.8333333],[53.0416666,18.8333333]],"sourceHandles":["A8D3","A8D4","A8D5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-13","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[46.9583333,18.8333333],[46.9583333,12.8333333],[47.1666666,12.8333333],[49.5,12.8333333],[49.5,18.8333333]],"sourceHandles":["A8D1","A8D2","A8D6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-14","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[43.8333333,18.8333333],[43.8333333,12.8333333],[46.1666666,12.8333333],[46.375,12.8333333],[46.375,18.8333333]],"sourceHandles":["A916","A917","A918"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-15","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[40.2916666,18.8333333],[40.2916666,12.8333333],[40.5,12.8333333],[42.8333333,12.8333333],[42.8333333,18.8333333]],"sourceHandles":["A914","A915","A919"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-16","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[37.1666666,18.8333333],[37.1666666,12.8333333],[39.5,12.8333333],[39.7083333,12.8333333],[39.7083333,18.8333333]],"sourceHandles":["A959","A95A","A95B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-17","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[33.625,18.8333333],[33.625,12.8333333],[33.8333333,12.8333333],[36.1666666,12.8333333],[36.1666666,18.8333333]],"sourceHandles":["A957","A958","A95C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-18","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[30.5,18.8333333],[30.5,12.8333333],[32.8333333,12.8333333],[33.0416666,12.8333333],[33.0416666,18.8333333]],"sourceHandles":["A99C","A99D","A99E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-19","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[26.9583333,18.8333333],[26.9583333,12.8333333],[27.1666666,12.8333333],[29.5,12.8333333],[29.5,18.8333333]],"sourceHandles":["A99A","A99B","A99F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-20","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[23.8333333,18.8333333],[23.8333333,12.8333333],[26.1666666,12.8333333],[26.375,12.8333333],[26.375,18.8333333]],"sourceHandles":["A9DF","A9E0","A9E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-21","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[20.2916666,18.8333333],[20.2916666,12.8333333],[20.5,12.8333333],[22.8333333,12.8333333],[22.8333333,18.8333333]],"sourceHandles":["A9DD","A9DE","A9E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-22","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[17.1666666,18.8333333],[17.1666666,12.8333333],[19.5,12.8333333],[19.7083333,12.8333333],[19.7083333,18.8333333]],"sourceHandles":["AA22","AA23","AA24"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-23","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[13.625,18.8333333],[13.625,12.8333333],[13.8333333,12.8333333],[16.1666666,12.8333333],[16.1666666,18.8333333]],"sourceHandles":["AA20","AA21","AA25"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-24","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[10.5,18.8333333],[10.5,12.8333333],[12.8333333,12.8333333],[13.0416666,12.8333333],[13.0416666,18.8333333]],"sourceHandles":["AA65","AA66","AA67"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-25","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[6.9583333,18.8333333],[6.9583333,12.8333333],[7.1666666,12.8333333],[9.5,12.8333333],[9.5,18.8333333]],"sourceHandles":["AA63","AA64","AA68"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-26","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[3.8333333,18.8333333],[3.8333333,12.8333333],[6.1666666,12.8333333],[6.375,12.8333333],[6.375,18.8333333]],"sourceHandles":["AAA8","AAA9","AAAA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-27","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[0.2916666,18.8333333],[0.2916666,12.8333333],[0.5,12.8333333],[2.8333333,12.8333333],[2.8333333,18.8333333]],"sourceHandles":["AAA6","AAA7","AAAB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-28","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[-2.8333334,18.8333333],[-2.8333334,12.8333333],[-0.5,12.8333333],[-0.2916667,12.8333333],[-0.2916667,18.8333333]],"sourceHandles":["AAEB","AAEC","AAED"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-29","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[-6.375,18.8333333],[-6.375,12.8333333],[-6.1666667,12.8333333],[-3.8333334,12.8333333],[-3.8333334,18.8333333]],"sourceHandles":["AAE9","AAEA","AAEE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-30","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[-9.5,18.8333333],[-9.5,12.8333333],[-7.1666667,12.8333333],[-6.9583334,12.8333333],[-6.9583334,18.8333333]],"sourceHandles":["AB2E","AB2F","AB30"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-31","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[-13.0416667,18.8333333],[-13.0416667,12.8333333],[-12.8333334,12.8333333],[-10.5,12.8333333],[-10.5,18.8333333]],"sourceHandles":["AB2C","AB2D","AB31"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-32","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[-16.1666667,18.8333333],[-16.1666667,12.8333333],[-13.8333334,12.8333333],[-13.625,12.8333333],[-13.625,18.8333333]],"sourceHandles":["AB71","AB72","AB73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-33","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[-19.7083334,18.8333333],[-19.7083334,12.8333333],[-19.5,12.8333333],[-17.1666667,12.8333333],[-17.1666667,18.8333333]],"sourceHandles":["AB6F","AB70","AB74"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-34","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[-22.8333334,18.8333333],[-22.8333334,12.8333333],[-20.5,12.8333333],[-20.2916667,12.8333333],[-20.2916667,18.8333333]],"sourceHandles":["ABB4","ABB5","ABB6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-35","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[-26.375,18.8333333],[-26.375,12.8333333],[-26.1666667,12.8333333],[-23.8333334,12.8333333],[-23.8333334,18.8333333]],"sourceHandles":["ABB2","ABB3","ABB7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-36","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[-29.5,18.8333333],[-29.5,12.8333333],[-27.1666667,12.8333333],[-26.9583334,12.8333333],[-26.9583334,18.8333333]],"sourceHandles":["ABF7","ABF8","ABF9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-37","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[-33.0416667,18.8333333],[-33.0416667,12.8333333],[-32.8333334,12.8333333],[-30.5,12.8333333],[-30.5,18.8333333]],"sourceHandles":["ABF5","ABF6","ABFA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-38","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[-36.1666667,18.8333333],[-36.1666667,12.8333333],[-33.8333334,12.8333333],[-33.625,12.8333333],[-33.625,18.8333333]],"sourceHandles":["AC39","AC3A","AC3B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-39","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[-39.7083334,18.8333333],[-39.7083334,12.8333333],[-39.5,12.8333333],[-37.1666667,12.8333333],[-37.1666667,18.8333333]],"sourceHandles":["AC37","AC38","AC3C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-40","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[-42.8333334,18.8333333],[-42.8333334,12.8333333],[-40.5,12.8333333],[-40.2916667,12.8333333],[-40.2916667,18.8333333]],"sourceHandles":["AC7B","AC7C","AC7D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-41","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[-46.375,18.8333333],[-46.375,12.8333333],[-46.1666667,12.8333333],[-43.8333334,12.8333333],[-43.8333334,18.8333333]],"sourceHandles":["AC79","AC7A","AC7E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-42","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[-49.5,18.8333333],[-49.5,12.8333333],[-47.1666667,12.8333333],[-46.9583334,12.8333333],[-46.9583334,18.8333333]],"sourceHandles":["ACBD","ACBE","ACBF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-43","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[-53.0416667,18.8333333],[-53.0416667,12.8333333],[-52.8333334,12.8333333],[-50.5,12.8333333],[-50.5,18.8333333]],"sourceHandles":["ACBB","ACBC","ACC0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-44","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[-56.1666667,18.8333333],[-56.1666667,12.8333333],[-53.8333334,12.8333333],[-53.625,12.8333333],[-53.625,18.8333333]],"sourceHandles":["ACFF","AD00","AD01"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-45","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[-59.7083334,18.8333333],[-59.7083334,12.8333333],[-59.5,12.8333333],[-57.1666667,12.8333333],[-57.1666667,18.8333333]],"sourceHandles":["ACFD","ACFE","AD02"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-46","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[-62.8333334,18.8333333],[-62.8333334,12.8333333],[-60.5,12.8333333],[-60.2916667,12.8333333],[-60.2916667,18.8333333]],"sourceHandles":["AD41","AD42","AD43"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-47","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[-66.375,18.8333333],[-66.375,12.8333333],[-66.1666667,12.8333333],[-63.8333334,12.8333333],[-63.8333334,18.8333333]],"sourceHandles":["AD3F","AD40","AD44"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-48","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[-69.5,18.8333333],[-69.5,12.8333333],[-67.1666667,12.8333333],[-66.9583334,12.8333333],[-66.9583334,18.8333333]],"sourceHandles":["AD83","AD84","AD85"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-49","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[-73.0416667,18.8333333],[-73.0416667,12.8333333],[-72.8333334,12.8333333],[-70.5,12.8333333],[-70.5,18.8333333]],"sourceHandles":["AD81","AD82","AD86"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-50","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[-76.1666667,18.8333333],[-76.1666667,12.8333333],[-73.8333334,12.8333333],[-73.625,12.8333333],[-73.625,18.8333333]],"sourceHandles":["ADC5","ADC6","ADC7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-51","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[-79.7083334,18.8333333],[-79.7083334,12.8333333],[-79.5,12.8333333],[-77.1666667,12.8333333],[-77.1666667,18.8333333]],"sourceHandles":["ADC3","ADC4","ADC8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-52","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[-82.8333334,18.8333333],[-82.8333334,12.8333333],[-80.5,12.8333333],[-80.2916667,12.8333333],[-80.2916667,18.8333333]],"sourceHandles":["AE07","AE08","AE09"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-53","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[-86.375,18.8333333],[-86.375,12.8333333],[-86.1666667,12.8333333],[-83.8333334,12.8333333],[-83.8333334,18.8333333]],"sourceHandles":["AE05","AE06","AE0A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-54","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[-89.5,18.8333333],[-89.5,12.8333333],[-87.1666667,12.8333333],[-86.9583334,12.8333333],[-86.9583334,18.8333333]],"sourceHandles":["AE49","AE4A","AE4B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-55","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[-93.0416667,18.8333333],[-93.0416667,12.8333333],[-92.8333334,12.8333333],[-90.5,12.8333333],[-90.5,18.8333333]],"sourceHandles":["AE47","AE48","AE4C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-56","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[-96.1668614,18.8333333],[-96.1668614,17.5049035],[-96.1668614,17.5],[-96.1668614,12.8333333],[-93.8333334,12.8333333],[-93.625,12.8333333],[-93.625,18.8333333]],"sourceHandles":["AE83","AE84","AE85"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-108-57","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[93.625,46.8333333],[93.625,39.5833333],[96.1666666,39.5833333],[96.1666666,46.8333333]],"sourceHandles":["A17F","A1A3","B297"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-0","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[90.5,46.8333333],[90.5,39.5833333],[93.0416666,39.5833333],[93.0416666,46.8333333]],"sourceHandles":["A19C","A1A4","A1A5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-1","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[86.9583333,46.8333333],[86.9583333,39.5833333],[89.5,39.5833333],[89.5,46.8333333]],"sourceHandles":["A19D","A1A6","A1A7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-2","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[83.8333333,46.8333333],[83.8333333,39.5833333],[86.375,39.5833333],[86.375,46.8333333]],"sourceHandles":["A1A8","A78C","B227"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-3","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[80.2916666,46.8333333],[80.2916666,39.5833333],[82.8333333,39.5833333],[82.8333333,46.8333333]],"sourceHandles":["A78D","B228","B229"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-4","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[77.1666666,46.8333333],[77.1666666,39.5833333],[79.7083333,39.5833333],[79.7083333,46.8333333]],"sourceHandles":["A7CF","B22A","B22B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-5","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[73.625,46.8333333],[73.625,39.5833333],[76.1666666,39.5833333],[76.1666666,46.8333333]],"sourceHandles":["A7D0","B22C","B22D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-6","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[70.5,46.8333333],[70.5,39.5833333],[73.0416666,39.5833333],[73.0416666,46.8333333]],"sourceHandles":["A812","B22E","B22F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-7","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[66.9583333,46.8333333],[66.9583333,39.5833333],[69.5,39.5833333],[69.5,46.8333333]],"sourceHandles":["A813","B230","B231"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-8","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[63.8333333,46.8333333],[63.8333333,39.5833333],[66.375,39.5833333],[66.375,46.8333333]],"sourceHandles":["A855","B232","B233"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-9","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[60.2916666,46.8333333],[60.2916666,39.5833333],[62.8333333,39.5833333],[62.8333333,46.8333333]],"sourceHandles":["A856","B234","B235"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-10","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[57.1666666,46.8333333],[57.1666666,39.5833333],[59.7083333,39.5833333],[59.7083333,46.8333333]],"sourceHandles":["A898","B236","B237"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-11","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[53.625,46.8333333],[53.625,39.5833333],[56.1666666,39.5833333],[56.1666666,46.8333333]],"sourceHandles":["A899","B238","B239"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-12","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[50.5,46.8333333],[50.5,39.5833333],[53.0416666,39.5833333],[53.0416666,46.8333333]],"sourceHandles":["A8DB","B23A","B23B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-13","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[46.9583333,46.8333333],[46.9583333,39.5833333],[49.5,39.5833333],[49.5,46.8333333]],"sourceHandles":["A8DC","B23C","B23D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-14","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[43.8333333,46.8333333],[43.8333333,39.5833333],[46.375,39.5833333],[46.375,46.8333333]],"sourceHandles":["A91E","B23E","B23F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-15","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[40.2916666,46.8333333],[40.2916666,39.5833333],[42.8333333,39.5833333],[42.8333333,46.8333333]],"sourceHandles":["A91F","B240","B241"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-16","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[37.1666666,46.8333333],[37.1666666,39.5833333],[39.7083333,39.5833333],[39.7083333,46.8333333]],"sourceHandles":["A961","B242","B243"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-17","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[33.625,46.8333333],[33.625,39.5833333],[36.1666666,39.5833333],[36.1666666,46.8333333]],"sourceHandles":["A962","B244","B245"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-18","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[30.5,46.8333333],[30.5,39.5833333],[33.0416666,39.5833333],[33.0416666,46.8333333]],"sourceHandles":["A9A4","B246","B247"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-19","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[26.9583333,46.8333333],[26.9583333,39.5833333],[29.5,39.5833333],[29.5,46.8333333]],"sourceHandles":["A9A5","B248","B249"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-20","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[23.8333333,46.8333333],[23.8333333,39.5833333],[26.375,39.5833333],[26.375,46.8333333]],"sourceHandles":["A9E7","B24A","B24B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-21","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[20.2916666,46.8333333],[20.2916666,39.5833333],[22.8333333,39.5833333],[22.8333333,46.8333333]],"sourceHandles":["A9E8","B24C","B24D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-22","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[17.1666666,46.8333333],[17.1666666,39.5833333],[19.7083333,39.5833333],[19.7083333,46.8333333]],"sourceHandles":["AA2A","B24E","B24F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-23","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[13.625,46.8333333],[13.625,39.5833333],[16.1666666,39.5833333],[16.1666666,46.8333333]],"sourceHandles":["AA2B","B250","B251"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-24","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[10.5,46.8333333],[10.5,39.5833333],[13.0416666,39.5833333],[13.0416666,46.8333333]],"sourceHandles":["AA6D","B252","B253"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-25","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[6.9583333,46.8333333],[6.9583333,39.5833333],[9.5,39.5833333],[9.5,46.8333333]],"sourceHandles":["AA6E","B254","B255"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-26","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[3.8333333,46.8333333],[3.8333333,39.5833333],[6.375,39.5833333],[6.375,46.8333333]],"sourceHandles":["AAB0","B256","B257"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-27","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[0.2916666,46.8333333],[0.2916666,39.5833333],[2.8333333,39.5833333],[2.8333333,46.8333333]],"sourceHandles":["AAB1","B258","B259"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-28","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[-2.8333334,46.8333333],[-2.8333334,39.5833333],[-0.2916667,39.5833333],[-0.2916667,46.8333333]],"sourceHandles":["AAF3","B25A","B25B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-29","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[-6.375,46.8333333],[-6.375,39.5833333],[-3.8333334,39.5833333],[-3.8333334,46.8333333]],"sourceHandles":["AAF4","B25C","B25D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-30","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[-9.5,46.8333333],[-9.5,39.5833333],[-6.9583334,39.5833333],[-6.9583334,46.8333333]],"sourceHandles":["AB36","B25E","B25F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-31","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[-13.0416667,46.8333333],[-13.0416667,39.5833333],[-10.5,39.5833333],[-10.5,46.8333333]],"sourceHandles":["AB37","B260","B261"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-32","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[-16.1666667,46.8333333],[-16.1666667,39.5833333],[-13.625,39.5833333],[-13.625,46.8333333]],"sourceHandles":["AB79","B262","B263"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-33","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[-19.7083334,46.8333333],[-19.7083334,39.5833333],[-17.1666667,39.5833333],[-17.1666667,46.8333333]],"sourceHandles":["AB7A","B264","B265"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-34","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[-22.8333334,46.8333333],[-22.8333334,39.5833333],[-20.2916667,39.5833333],[-20.2916667,46.8333333]],"sourceHandles":["ABBC","B266","B267"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-35","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[-26.375,46.8333333],[-26.375,39.5833333],[-23.8333334,39.5833333],[-23.8333334,46.8333333]],"sourceHandles":["ABBD","B268","B269"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-36","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[-29.5,46.8333333],[-29.5,39.5833333],[-26.9583334,39.5833333],[-26.9583334,46.8333333]],"sourceHandles":["ABFF","B26A","B26B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-37","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[-33.0416667,46.8333333],[-33.0416667,39.5833333],[-30.5,39.5833333],[-30.5,46.8333333]],"sourceHandles":["AC00","B26C","B26D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-38","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[-36.1666667,46.8333333],[-36.1666667,39.5833333],[-33.625,39.5833333],[-33.625,46.8333333]],"sourceHandles":["AC41","B26E","B26F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-39","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[-39.7083334,46.8333333],[-39.7083334,39.5833333],[-37.1666667,39.5833333],[-37.1666667,46.8333333]],"sourceHandles":["AC42","B270","B271"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-40","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[-42.8333334,46.8333333],[-42.8333334,39.5833333],[-40.2916667,39.5833333],[-40.2916667,46.8333333]],"sourceHandles":["AC83","B272","B273"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-41","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[-46.375,46.8333333],[-46.375,39.5833333],[-43.8333334,39.5833333],[-43.8333334,46.8333333]],"sourceHandles":["AC84","B274","B275"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-42","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[-49.5,46.8333333],[-49.5,39.5833333],[-46.9583334,39.5833333],[-46.9583334,46.8333333]],"sourceHandles":["ACC5","B276","B277"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-43","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[-53.0416667,46.8333333],[-53.0416667,39.5833333],[-50.5,39.5833333],[-50.5,46.8333333]],"sourceHandles":["ACC6","B278","B279"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-44","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[-56.1666667,46.8333333],[-56.1666667,39.5833333],[-53.625,39.5833333],[-53.625,46.8333333]],"sourceHandles":["AD07","B27A","B27B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-45","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[-59.7083334,46.8333333],[-59.7083334,39.5833333],[-57.1666667,39.5833333],[-57.1666667,46.8333333]],"sourceHandles":["AD08","B27C","B27D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-46","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[-62.8333334,46.8333333],[-62.8333334,39.5833333],[-60.2916667,39.5833333],[-60.2916667,46.8333333]],"sourceHandles":["AD49","B27E","B27F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-47","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[-66.375,46.8333333],[-66.375,39.5833333],[-63.8333334,39.5833333],[-63.8333334,46.8333333]],"sourceHandles":["AD4A","B280","B281"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-48","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[-69.5,46.8333333],[-69.5,39.5833333],[-66.9583334,39.5833333],[-66.9583334,46.8333333]],"sourceHandles":["AD8B","B282","B283"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-49","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[-73.0416667,46.8333333],[-73.0416667,39.5833333],[-70.5,39.5833333],[-70.5,46.8333333]],"sourceHandles":["AD8C","B284","B285"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-50","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[-76.1666667,46.8333333],[-76.1666667,39.5833333],[-73.625,39.5833333],[-73.625,46.8333333]],"sourceHandles":["ADCD","B286","B287"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-51","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[-79.7083334,46.8333333],[-79.7083334,39.5833333],[-77.1666667,39.5833333],[-77.1666667,46.8333333]],"sourceHandles":["ADCE","B288","B289"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-52","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[-82.8333334,46.8333333],[-82.8333334,39.5833333],[-80.2916667,39.5833333],[-80.2916667,46.8333333]],"sourceHandles":["AE0F","B28A","B28B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-53","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[-86.375,46.8333333],[-86.375,39.5833333],[-83.8333334,39.5833333],[-83.8333334,46.8333333]],"sourceHandles":["AE10","B28C","B28D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-54","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[-89.5,46.8333333],[-89.5,39.5833333],[-86.9583334,39.5833333],[-86.9583334,46.8333333]],"sourceHandles":["AE51","B28E","B28F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-55","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[-93.0416667,46.8333333],[-93.0416667,39.5833333],[-90.5,39.5833333],[-90.5,46.8333333]],"sourceHandles":["AE52","B290","B291"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-56","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[-96.1668614,46.8333333],[-96.1668614,39.5833333],[-93.625,39.5833333],[-93.625,46.8333333]],"sourceHandles":["B292","B293"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-north-spandrel-110-57","tower":2,"face":"north","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":259,"columnIndex":58,"outlineFt":[[98.375,-5.8333334],[98.375,-0.0],[98.375,1.25],[98.375,17.5],[98.375,22.1666666],[98.375,37.5],[98.375,49.0833333],[96.1666667,49.0833333],[96.1666667,37.5],[95.9791667,37.5],[95.9791667,22.1666666],[96.1666667,22.1666666],[96.1666667,17.5],[96.1666667,1.25],[96.1170343,-0.0],[95.8854167,-5.8333334]],"sourceHandles":["28672","28674","2867B","2867C","2867F","28D3B","28D3C","28D40"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":259,"id":"upper-exterior-1-east-column-259","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":258,"columnIndex":57,"outlineFt":[[94.1145834,-5.8333334],[93.8333334,1.25],[93.8333334,12.8333333],[93.625,12.8333333],[93.625,22.1666666],[93.625,37.5],[93.625,46.8333333],[93.0416667,46.8333333],[93.0416667,37.5],[93.0416667,22.1666666],[93.0416667,12.8333333],[92.8333334,12.8333333],[92.8333334,1.25],[92.5520834,-5.8333334]],"sourceHandles":["2866C","2866D","28670","28671","287F4","287F5","287F8","287F9","2880C","2880D","28825","28826"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":258,"id":"upper-exterior-1-east-column-258","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":257,"columnIndex":56,"outlineFt":[[90.78125,-5.8333334],[90.5,1.25],[90.5,12.8333333],[90.5,22.1666666],[90.6875,22.1666666],[90.6875,37.5],[90.5,37.5],[90.5,46.8333333],[89.5,46.8333333],[89.5,37.5],[89.3125,37.5],[89.3125,22.1666666],[89.5,22.1666666],[89.5,12.8333333],[89.5,1.25],[89.21875,-5.8333334]],"sourceHandles":["2866E","28681","28684","28685","287E4","287E5","287EA","287EB","287EC","287ED"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":257,"id":"upper-exterior-1-east-column-257","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":256,"columnIndex":55,"outlineFt":[[87.4479167,-5.8333334],[87.1666667,1.25],[87.1666667,12.8333333],[86.9583334,12.8333333],[86.9583334,22.1666666],[86.9583334,37.5],[86.9583334,46.8333333],[86.375,46.8333333],[86.375,37.5],[86.375,22.1666666],[86.375,12.8333333],[86.1666667,12.8333333],[86.1666667,1.25],[85.8854167,-5.8333334]],"sourceHandles":["28682","28687","2868A","2868B","287DE","287DF","287E8","287E9","2880E","2880F","2881B","2881C"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":256,"id":"upper-exterior-1-east-column-256","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":255,"columnIndex":54,"outlineFt":[[84.1145834,-5.8333334],[83.8333334,1.25],[83.8333334,12.8333333],[83.8333334,22.1666666],[84.0208334,22.1666666],[84.0208334,37.5],[83.8333334,37.5],[83.8333334,46.8333333],[82.8333334,46.8333333],[82.8333334,37.5],[82.6458334,37.5],[82.6458334,22.1666666],[82.8333334,22.1666666],[82.8333334,12.8333333],[82.8333334,1.25],[82.5520834,-5.8333334]],"sourceHandles":["28688","2868D","28690","28691","2882F","28830","28835","28836","28837","28838"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":255,"id":"upper-exterior-1-east-column-255","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":254,"columnIndex":53,"outlineFt":[[80.78125,-5.8333334],[80.5,1.25],[80.5,12.8333333],[80.2916667,12.8333333],[80.2916667,22.1666666],[80.2916667,37.5],[80.2916667,46.8333333],[79.7083334,46.8333333],[79.7083334,37.5],[79.7083334,22.1666666],[79.7083334,12.8333333],[79.5,12.8333333],[79.5,1.25],[79.21875,-5.8333334]],"sourceHandles":["2868E","28693","28696","28697","2882B","2882C","28833","28834","2884B","2884C","28852","28853"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":254,"id":"upper-exterior-1-east-column-254","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":253,"columnIndex":52,"outlineFt":[[77.4479167,-5.8333334],[77.1666667,1.25],[77.1666667,12.8333333],[77.1666667,22.1666666],[77.3541667,22.1666666],[77.3541667,37.5],[77.1666667,37.5],[77.1666667,46.8333333],[76.1666667,46.8333333],[76.1666667,37.5],[75.9791667,37.5],[75.9791667,22.1666666],[76.1666667,22.1666666],[76.1666667,12.8333333],[76.1666667,1.25],[75.8854167,-5.8333334]],"sourceHandles":["28694","28699","2869C","2869D","2885F","28860","28865","28866","28867","28868"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":253,"id":"upper-exterior-1-east-column-253","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":252,"columnIndex":51,"outlineFt":[[74.1145834,-5.8333334],[73.8333334,1.25],[73.8333334,12.8333333],[73.625,12.8333333],[73.625,22.1666666],[73.625,37.5],[73.625,46.8333333],[73.0416667,46.8333333],[73.0416667,37.5],[73.0416667,22.1666666],[73.0416667,12.8333333],[72.8333334,12.8333333],[72.8333334,1.25],[72.5520834,-5.8333334]],"sourceHandles":["2869A","2869F","286A2","286A3","2885B","2885C","28863","28864","2887B","2887C","28882","28883"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":252,"id":"upper-exterior-1-east-column-252","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":251,"columnIndex":50,"outlineFt":[[70.78125,-5.8333334],[70.5,1.25],[70.5,12.8333333],[70.5,22.1666666],[70.6875,22.1666666],[70.6875,37.5],[70.5,37.5],[70.5,46.8333333],[69.5,46.8333333],[69.5,37.5],[69.3125,37.5],[69.3125,22.1666666],[69.5,22.1666666],[69.5,12.8333333],[69.5,1.25],[69.21875,-5.8333334]],"sourceHandles":["286A0","286A5","286A8","286A9","2888F","28890","28895","28896","28897","28898"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":251,"id":"upper-exterior-1-east-column-251","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":250,"columnIndex":49,"outlineFt":[[67.4479167,-5.8333334],[67.1666667,1.25],[67.1666667,12.8333333],[66.9583334,12.8333333],[66.9583334,22.1666666],[66.9583334,37.5],[66.9583334,46.8333333],[66.375,46.8333333],[66.375,37.5],[66.375,22.1666666],[66.375,12.8333333],[66.1666667,12.8333333],[66.1666667,1.25],[65.8854167,-5.8333334]],"sourceHandles":["286A6","286AB","286AE","286AF","2888B","2888C","28893","28894","288AB","288AC","288B2","288B3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":250,"id":"upper-exterior-1-east-column-250","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":249,"columnIndex":48,"outlineFt":[[64.1145834,-5.8333334],[63.8333334,1.25],[63.8333334,12.8333333],[63.8333334,22.1666666],[64.0208334,22.1666666],[64.0208334,37.5],[63.8333334,37.5],[63.8333334,46.8333333],[62.8333334,46.8333333],[62.8333334,37.5],[62.6458334,37.5],[62.6458334,22.1666666],[62.8333334,22.1666666],[62.8333334,12.8333333],[62.8333334,1.25],[62.5520834,-5.8333334]],"sourceHandles":["286AC","286B1","286B4","286B5","288BF","288C0","288C5","288C6","288C7","288C8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":249,"id":"upper-exterior-1-east-column-249","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":248,"columnIndex":47,"outlineFt":[[60.78125,-5.8333334],[60.5,1.25],[60.5,12.8333333],[60.2916667,12.8333333],[60.2916667,22.1666666],[60.2916667,37.5],[60.2916667,46.8333333],[59.7083334,46.8333333],[59.7083334,37.5],[59.7083334,22.1666666],[59.7083334,12.8333333],[59.5,12.8333333],[59.5,1.25],[59.21875,-5.8333334]],"sourceHandles":["286B2","286B7","286BA","286BB","288BB","288BC","288C3","288C4","288DB","288DC","288E2","288E3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":248,"id":"upper-exterior-1-east-column-248","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":247,"columnIndex":46,"outlineFt":[[57.4479167,-5.8333334],[57.1666667,1.25],[57.1666667,12.8333333],[57.1666667,22.1666666],[57.3541667,22.1666666],[57.3541667,37.5],[57.1666667,37.5],[57.1666667,46.8333333],[56.1666667,46.8333333],[56.1666667,37.5],[55.9791667,37.5],[55.9791667,22.1666666],[56.1666667,22.1666666],[56.1666667,12.8333333],[56.1666667,1.25],[55.8854167,-5.8333334]],"sourceHandles":["286B8","286BD","286C0","286C1","288EF","288F0","288F5","288F6","288F7","288F8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":247,"id":"upper-exterior-1-east-column-247","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":246,"columnIndex":45,"outlineFt":[[54.1145834,-5.8333334],[53.8333334,1.25],[53.8333334,12.8333333],[53.625,12.8333333],[53.625,22.1666666],[53.625,37.5],[53.625,46.8333333],[53.0416667,46.8333333],[53.0416667,37.5],[53.0416667,22.1666666],[53.0416667,12.8333333],[52.8333334,12.8333333],[52.8333334,1.25],[52.5520834,-5.8333334]],"sourceHandles":["286BE","286C3","286C6","286C7","288EB","288EC","288F3","288F4","2890B","2890C","28912","28913"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":246,"id":"upper-exterior-1-east-column-246","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":245,"columnIndex":44,"outlineFt":[[50.78125,-5.8333334],[50.5,1.25],[50.5,12.8333333],[50.5,22.1666666],[50.6875,22.1666666],[50.6875,37.5],[50.5,37.5],[50.5,46.8333333],[49.5,46.8333333],[49.5,37.5],[49.3125,37.5],[49.3125,22.1666666],[49.5,22.1666666],[49.5,12.8333333],[49.5,1.25],[49.21875,-5.8333334]],"sourceHandles":["286C4","286C9","286CC","286CD","2891F","28920","28925","28926","28927","28928"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":245,"id":"upper-exterior-1-east-column-245","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":244,"columnIndex":43,"outlineFt":[[47.4479167,-5.8333334],[47.1666667,1.25],[47.1666667,12.8333333],[46.9583334,12.8333333],[46.9583334,22.1666666],[46.9583334,37.5],[46.9583334,46.8333333],[46.375,46.8333333],[46.375,37.5],[46.375,22.1666666],[46.375,12.8333333],[46.1666667,12.8333333],[46.1666667,1.25],[45.8854167,-5.8333334]],"sourceHandles":["286CA","286CF","286D2","286D3","2891B","2891C","28923","28924","2893B","2893C","28942","28943"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":244,"id":"upper-exterior-1-east-column-244","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":243,"columnIndex":42,"outlineFt":[[44.1145834,-5.8333334],[43.8333334,1.25],[43.8333334,12.8333333],[43.8333334,22.1666666],[44.0208334,22.1666666],[44.0208334,37.5],[43.8333334,37.5],[43.8333334,46.8333333],[42.8333334,46.8333333],[42.8333334,37.5],[42.6458334,37.5],[42.6458334,22.1666666],[42.8333334,22.1666666],[42.8333334,12.8333333],[42.8333334,1.25],[42.5520834,-5.8333334]],"sourceHandles":["286D0","286D5","286D8","286D9","2894F","28950","28955","28956","28957","28958"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":243,"id":"upper-exterior-1-east-column-243","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":242,"columnIndex":41,"outlineFt":[[40.78125,-5.8333334],[40.5,1.25],[40.5,12.8333333],[40.2916667,12.8333333],[40.2916667,22.1666666],[40.2916667,37.5],[40.2916667,46.8333333],[39.7083334,46.8333333],[39.7083334,37.5],[39.7083334,22.1666666],[39.7083334,12.8333333],[39.5,12.8333333],[39.5,1.25],[39.21875,-5.8333334]],"sourceHandles":["286D6","286DB","286DE","286DF","2894B","2894C","28953","28954","2896B","2896C","28972","28973"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":242,"id":"upper-exterior-1-east-column-242","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":241,"columnIndex":40,"outlineFt":[[37.4479167,-5.8333334],[37.1666667,1.25],[37.1666667,12.8333333],[37.1666667,22.1666666],[37.3541667,22.1666666],[37.3541667,37.5],[37.1666667,37.5],[37.1666667,46.8333333],[36.1666667,46.8333333],[36.1666667,37.5],[35.9791667,37.5],[35.9791667,22.1666666],[36.1666667,22.1666666],[36.1666667,12.8333333],[36.1666667,1.25],[35.8854167,-5.8333334]],"sourceHandles":["286DC","286E1","286E4","286E5","2897F","28980","28985","28986","28987","28988"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":241,"id":"upper-exterior-1-east-column-241","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":240,"columnIndex":39,"outlineFt":[[34.1145834,-5.8333334],[33.8333334,1.25],[33.8333334,12.8333333],[33.625,12.8333333],[33.625,22.1666666],[33.625,37.5],[33.625,46.8333333],[33.0416667,46.8333333],[33.0416667,37.5],[33.0416667,22.1666666],[33.0416667,12.8333333],[32.8333334,12.8333333],[32.8333334,1.25],[32.5520834,-5.8333334]],"sourceHandles":["286E2","286E7","286EA","286EB","2897B","2897C","28983","28984","2899B","2899C","289A2","289A3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":240,"id":"upper-exterior-1-east-column-240","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":239,"columnIndex":38,"outlineFt":[[30.78125,-5.8333334],[30.5,1.25],[30.5,12.8333333],[30.5,22.1666666],[30.6875,22.1666666],[30.6875,37.5],[30.5,37.5],[30.5,46.8333333],[29.5,46.8333333],[29.5,37.5],[29.3125,37.5],[29.3125,22.1666666],[29.5,22.1666666],[29.5,12.8333333],[29.5,1.25],[29.21875,-5.8333334]],"sourceHandles":["286E8","286ED","286F0","286F1","289AF","289B0","289B5","289B6","289B7","289B8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":239,"id":"upper-exterior-1-east-column-239","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":238,"columnIndex":37,"outlineFt":[[27.4479167,-5.8333334],[27.1666667,1.25],[27.1666667,12.8333333],[26.9583334,12.8333333],[26.9583334,22.1666666],[26.9583334,37.5],[26.9583334,46.8333333],[26.375,46.8333333],[26.375,37.5],[26.375,22.1666666],[26.375,12.8333333],[26.1666667,12.8333333],[26.1666667,1.25],[25.8854167,-5.8333334]],"sourceHandles":["286EE","286F3","286F6","286F7","289AB","289AC","289B3","289B4","289CB","289CC","289D2","289D3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":238,"id":"upper-exterior-1-east-column-238","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":237,"columnIndex":36,"outlineFt":[[24.1145834,-5.8333334],[23.8333334,1.25],[23.8333334,12.8333333],[23.8333334,22.1666666],[24.0208334,22.1666666],[24.0208334,37.5],[23.8333334,37.5],[23.8333334,46.8333333],[22.8333334,46.8333333],[22.8333334,37.5],[22.6458334,37.5],[22.6458334,22.1666666],[22.8333334,22.1666666],[22.8333334,12.8333333],[22.8333334,1.25],[22.5520834,-5.8333334]],"sourceHandles":["286F4","286F9","286FC","286FD","289DF","289E0","289E5","289E6","289E7","289E8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":237,"id":"upper-exterior-1-east-column-237","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":236,"columnIndex":35,"outlineFt":[[20.78125,-5.8333334],[20.5,1.25],[20.5,12.8333333],[20.2916667,12.8333333],[20.2916667,22.1666666],[20.2916667,37.5],[20.2916667,46.8333333],[19.7083334,46.8333333],[19.7083334,37.5],[19.7083334,22.1666666],[19.7083334,12.8333333],[19.5,12.8333333],[19.5,1.25],[19.21875,-5.8333334]],"sourceHandles":["286FA","286FF","28702","28703","289DB","289DC","289E3","289E4","289FB","289FC","28A02","28A03"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":236,"id":"upper-exterior-1-east-column-236","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":235,"columnIndex":34,"outlineFt":[[17.4479167,-5.8333334],[17.1666667,1.25],[17.1666667,12.8333333],[17.1666667,22.1666666],[17.3541667,22.1666666],[17.3541667,37.5],[17.1666667,37.5],[17.1666667,46.8333333],[16.1666667,46.8333333],[16.1666667,37.5],[15.9791667,37.5],[15.9791667,22.1666666],[16.1666667,22.1666666],[16.1666667,12.8333333],[16.1666667,1.25],[15.8854167,-5.8333334]],"sourceHandles":["28700","28705","28708","28709","28A0F","28A10","28A15","28A16","28A17","28A18"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":235,"id":"upper-exterior-1-east-column-235","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":234,"columnIndex":33,"outlineFt":[[14.1145834,-5.8333334],[13.8333334,1.25],[13.8333334,12.8333333],[13.625,12.8333333],[13.625,22.1666666],[13.625,37.5],[13.625,46.8333333],[13.0416667,46.8333333],[13.0416667,37.5],[13.0416667,22.1666666],[13.0416667,12.8333333],[12.8333334,12.8333333],[12.8333334,1.25],[12.5520834,-5.8333334]],"sourceHandles":["28706","2870B","2870E","2870F","28A0B","28A0C","28A13","28A14","28A2B","28A2C","28A32","28A33"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":234,"id":"upper-exterior-1-east-column-234","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":233,"columnIndex":32,"outlineFt":[[10.78125,-5.8333334],[10.5,1.25],[10.5,12.8333333],[10.5,22.1666666],[10.6875,22.1666666],[10.6875,37.5],[10.5,37.5],[10.5,46.8333333],[9.5,46.8333333],[9.5,37.5],[9.3125,37.5],[9.3125,22.1666666],[9.5,22.1666666],[9.5,12.8333333],[9.5,1.25],[9.21875,-5.8333334]],"sourceHandles":["2870C","28711","28714","28715","28A3F","28A40","28A45","28A46","28A47","28A48"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":233,"id":"upper-exterior-1-east-column-233","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":232,"columnIndex":31,"outlineFt":[[7.4479167,-5.8333334],[7.1666667,1.25],[7.1666667,12.8333333],[6.9583334,12.8333333],[6.9583334,22.1666666],[6.9583334,37.5],[6.9583334,46.8333333],[6.375,46.8333333],[6.375,37.5],[6.375,22.1666666],[6.375,12.8333333],[6.1666667,12.8333333],[6.1666667,1.25],[5.8854167,-5.8333334]],"sourceHandles":["28712","28717","2871A","2871B","28A3B","28A3C","28A43","28A44","28A5B","28A5C","28A62","28A63"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":232,"id":"upper-exterior-1-east-column-232","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":231,"columnIndex":30,"outlineFt":[[4.1145834,-5.8333334],[3.8333334,1.25],[3.8333334,12.8333333],[3.8333334,22.1666666],[4.0208334,22.1666666],[4.0208334,37.5],[3.8333334,37.5],[3.8333334,46.8333333],[2.8333334,46.8333333],[2.8333334,37.5],[2.6458334,37.5],[2.6458334,22.1666666],[2.8333334,22.1666666],[2.8333334,12.8333333],[2.8333334,1.25],[2.5520834,-5.8333334]],"sourceHandles":["28718","2871D","28720","28721","28A6F","28A70","28A75","28A76","28A77","28A78"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":231,"id":"upper-exterior-1-east-column-231","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":230,"columnIndex":29,"outlineFt":[[0.78125,-5.8333334],[0.5,1.25],[0.5,12.8333333],[0.2916667,12.8333333],[0.2916667,22.1666666],[0.2916667,37.5],[0.2916667,46.8333333],[-0.2916666,46.8333333],[-0.2916666,37.5],[-0.2916666,22.1666666],[-0.2916666,12.8333333],[-0.5,12.8333333],[-0.5,1.25],[-0.78125,-5.8333334]],"sourceHandles":["2871E","28723","28726","28727","28A6B","28A6C","28A73","28A74","28A8B","28A8C","28A92","28A93"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":230,"id":"upper-exterior-1-east-column-230","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":229,"columnIndex":28,"outlineFt":[[-2.5520833,-5.8333334],[-2.8333333,1.25],[-2.8333333,12.8333333],[-2.8333333,22.1666666],[-2.6458333,22.1666666],[-2.6458333,37.5],[-2.8333333,37.5],[-2.8333333,46.8333333],[-3.8333333,46.8333333],[-3.8333333,37.5],[-4.0208333,37.5],[-4.0208333,22.1666666],[-3.8333333,22.1666666],[-3.8333333,12.8333333],[-3.8333333,1.25],[-4.1145833,-5.8333334]],"sourceHandles":["28724","28729","2872C","2872D","28A9F","28AA0","28AA5","28AA6","28AA7","28AA8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":229,"id":"upper-exterior-1-east-column-229","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":228,"columnIndex":27,"outlineFt":[[-5.8854166,-5.8333334],[-6.1666666,1.25],[-6.1666666,12.8333333],[-6.375,12.8333333],[-6.375,22.1666666],[-6.375,37.5],[-6.375,46.8333333],[-6.9583333,46.8333333],[-6.9583333,37.5],[-6.9583333,22.1666666],[-6.9583333,12.8333333],[-7.1666666,12.8333333],[-7.1666666,1.25],[-7.4479166,-5.8333334]],"sourceHandles":["2872A","2872F","28732","28733","28A9B","28A9C","28AA3","28AA4","28ABB","28ABC","28AC2","28AC3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":228,"id":"upper-exterior-1-east-column-228","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":227,"columnIndex":26,"outlineFt":[[-9.21875,-5.8333334],[-9.5,1.25],[-9.5,12.8333333],[-9.5,22.1666666],[-9.3125,22.1666666],[-9.3125,37.5],[-9.5,37.5],[-9.5,46.8333333],[-10.5,46.8333333],[-10.5,37.5],[-10.6875,37.5],[-10.6875,22.1666666],[-10.5,22.1666666],[-10.5,12.8333333],[-10.5,1.25],[-10.78125,-5.8333334]],"sourceHandles":["28730","28735","28738","28739","28ACF","28AD0","28AD5","28AD6","28AD7","28AD8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":227,"id":"upper-exterior-1-east-column-227","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":226,"columnIndex":25,"outlineFt":[[-12.5520833,-5.8333334],[-12.8333333,1.25],[-12.8333333,12.8333333],[-13.0416666,12.8333333],[-13.0416666,22.1666666],[-13.0416666,37.5],[-13.0416666,46.8333333],[-13.625,46.8333333],[-13.625,37.5],[-13.625,22.1666666],[-13.625,12.8333333],[-13.8333333,12.8333333],[-13.8333333,1.25],[-14.1145833,-5.8333334]],"sourceHandles":["28736","2873B","2873E","2873F","28ACB","28ACC","28AD3","28AD4","28AEB","28AEC","28AF2","28AF3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":226,"id":"upper-exterior-1-east-column-226","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":225,"columnIndex":24,"outlineFt":[[-15.8854166,-5.8333334],[-16.1666666,1.25],[-16.1666666,12.8333333],[-16.1666666,22.1666666],[-15.9791666,22.1666666],[-15.9791666,37.5],[-16.1666666,37.5],[-16.1666666,46.8333333],[-17.1666666,46.8333333],[-17.1666666,37.5],[-17.3541666,37.5],[-17.3541666,22.1666666],[-17.1666666,22.1666666],[-17.1666666,12.8333333],[-17.1666666,1.25],[-17.4479166,-5.8333334]],"sourceHandles":["2873C","28741","28744","28745","28AFF","28B00","28B05","28B06","28B07","28B08"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":225,"id":"upper-exterior-1-east-column-225","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":224,"columnIndex":23,"outlineFt":[[-19.21875,-5.8333334],[-19.5,1.25],[-19.5,12.8333333],[-19.7083333,12.8333333],[-19.7083333,22.1666666],[-19.7083333,37.5],[-19.7083333,46.8333333],[-20.2916666,46.8333333],[-20.2916666,37.5],[-20.2916666,22.1666666],[-20.2916666,12.8333333],[-20.5,12.8333333],[-20.5,1.25],[-20.78125,-5.8333334]],"sourceHandles":["28742","28747","2874A","2874B","28AFB","28AFC","28B03","28B04","28B1B","28B1C","28B22","28B23"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":224,"id":"upper-exterior-1-east-column-224","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":223,"columnIndex":22,"outlineFt":[[-22.5520833,-5.8333334],[-22.8333333,1.25],[-22.8333333,12.8333333],[-22.8333333,22.1666666],[-22.6458333,22.1666666],[-22.6458333,37.5],[-22.8333333,37.5],[-22.8333333,46.8333333],[-23.8333333,46.8333333],[-23.8333333,37.5],[-24.0208333,37.5],[-24.0208333,22.1666666],[-23.8333333,22.1666666],[-23.8333333,12.8333333],[-23.8333333,1.25],[-24.1145833,-5.8333334]],"sourceHandles":["28748","2874D","28750","28751","28B2F","28B30","28B35","28B36","28B37","28B38"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":223,"id":"upper-exterior-1-east-column-223","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":222,"columnIndex":21,"outlineFt":[[-25.8854166,-5.8333334],[-26.1666666,1.25],[-26.1666666,12.8333333],[-26.375,12.8333333],[-26.375,22.1666666],[-26.375,37.5],[-26.375,46.8333333],[-26.9583333,46.8333333],[-26.9583333,37.5],[-26.9583333,22.1666666],[-26.9583333,12.8333333],[-27.1666666,12.8333333],[-27.1666666,1.25],[-27.4479166,-5.8333334]],"sourceHandles":["2874E","28753","28756","28757","28B2B","28B2C","28B33","28B34","28B4B","28B4C","28B52","28B53"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":222,"id":"upper-exterior-1-east-column-222","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":221,"columnIndex":20,"outlineFt":[[-29.21875,-5.8333334],[-29.5,1.25],[-29.5,12.8333333],[-29.5,22.1666666],[-29.3125,22.1666666],[-29.3125,37.5],[-29.5,37.5],[-29.5,46.8333333],[-30.5,46.8333333],[-30.5,37.5],[-30.6875,37.5],[-30.6875,22.1666666],[-30.5,22.1666666],[-30.5,12.8333333],[-30.5,1.25],[-30.78125,-5.8333334]],"sourceHandles":["28754","28759","2875C","2875D","28B5F","28B60","28B65","28B66","28B67","28B68"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":221,"id":"upper-exterior-1-east-column-221","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":220,"columnIndex":19,"outlineFt":[[-32.5520833,-5.8333334],[-32.8333333,1.25],[-32.8333333,12.8333333],[-33.0416666,12.8333333],[-33.0416666,22.1666666],[-33.0416666,37.5],[-33.0416666,46.8333333],[-33.625,46.8333333],[-33.625,37.5],[-33.625,22.1666666],[-33.625,12.8333333],[-33.8333333,12.8333333],[-33.8333333,1.25],[-34.1145833,-5.8333334]],"sourceHandles":["2875A","2875F","28762","28763","28B5B","28B5C","28B63","28B64","28B7B","28B7C","28B82","28B83"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":220,"id":"upper-exterior-1-east-column-220","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":219,"columnIndex":18,"outlineFt":[[-35.8854166,-5.8333334],[-36.1666666,1.25],[-36.1666666,12.8333333],[-36.1666666,22.1666666],[-35.9791666,22.1666666],[-35.9791666,37.5],[-36.1666666,37.5],[-36.1666666,46.8333333],[-37.1666666,46.8333333],[-37.1666666,37.5],[-37.3541666,37.5],[-37.3541666,22.1666666],[-37.1666666,22.1666666],[-37.1666666,12.8333333],[-37.1666666,1.25],[-37.4479166,-5.8333334]],"sourceHandles":["28760","28765","28768","28769","28B8F","28B90","28B95","28B96","28B97","28B98"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":219,"id":"upper-exterior-1-east-column-219","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":218,"columnIndex":17,"outlineFt":[[-39.21875,-5.8333334],[-39.5,1.25],[-39.5,12.8333333],[-39.7083333,12.8333333],[-39.7083333,22.1666666],[-39.7083333,37.5],[-39.7083333,46.8333333],[-40.2916666,46.8333333],[-40.2916666,37.5],[-40.2916666,22.1666666],[-40.2916666,12.8333333],[-40.5,12.8333333],[-40.5,1.25],[-40.78125,-5.8333334]],"sourceHandles":["28766","2876B","2876E","2876F","28B8B","28B8C","28B93","28B94","28BAB","28BAC","28BB2","28BB3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":218,"id":"upper-exterior-1-east-column-218","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":217,"columnIndex":16,"outlineFt":[[-42.5520833,-5.8333334],[-42.8333333,1.25],[-42.8333333,12.8333333],[-42.8333333,22.1666666],[-42.6458333,22.1666666],[-42.6458333,37.5],[-42.8333333,37.5],[-42.8333333,46.8333333],[-43.8333333,46.8333333],[-43.8333333,37.5],[-44.0208333,37.5],[-44.0208333,22.1666666],[-43.8333333,22.1666666],[-43.8333333,12.8333333],[-43.8333333,1.25],[-44.1145833,-5.8333334]],"sourceHandles":["2876C","28771","28774","28775","28BBF","28BC0","28BC5","28BC6","28BC7","28BC8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":217,"id":"upper-exterior-1-east-column-217","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":216,"columnIndex":15,"outlineFt":[[-45.8854166,-5.8333334],[-46.1666666,1.25],[-46.1666666,12.8333333],[-46.375,12.8333333],[-46.375,22.1666666],[-46.375,37.5],[-46.375,46.8333333],[-46.9583333,46.8333333],[-46.9583333,37.5],[-46.9583333,22.1666666],[-46.9583333,12.8333333],[-47.1666666,12.8333333],[-47.1666666,1.25],[-47.4479166,-5.8333334]],"sourceHandles":["28772","28777","2877A","2877B","28BBB","28BBC","28BC3","28BC4","28BDB","28BDC","28BE2","28BE3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":216,"id":"upper-exterior-1-east-column-216","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":215,"columnIndex":14,"outlineFt":[[-49.21875,-5.8333334],[-49.5,1.25],[-49.5,12.8333333],[-49.5,22.1666666],[-49.3125,22.1666666],[-49.3125,37.5],[-49.5,37.5],[-49.5,46.8333333],[-50.5,46.8333333],[-50.5,37.5],[-50.6875,37.5],[-50.6875,22.1666666],[-50.5,22.1666666],[-50.5,12.8333333],[-50.5,1.25],[-50.78125,-5.8333334]],"sourceHandles":["28778","2877D","28780","28781","28BEF","28BF0","28BF5","28BF6","28BF7","28BF8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":215,"id":"upper-exterior-1-east-column-215","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":214,"columnIndex":13,"outlineFt":[[-52.5520833,-5.8333334],[-52.8333333,1.25],[-52.8333333,12.8333333],[-53.0416666,12.8333333],[-53.0416666,22.1666666],[-53.0416666,37.5],[-53.0416666,46.8333333],[-53.625,46.8333333],[-53.625,37.5],[-53.625,22.1666666],[-53.625,12.8333333],[-53.8333333,12.8333333],[-53.8333333,1.25],[-54.1145833,-5.8333334]],"sourceHandles":["2877E","28783","28786","28787","28BEB","28BEC","28BF3","28BF4","28C0B","28C0C","28C12","28C13"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":214,"id":"upper-exterior-1-east-column-214","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":213,"columnIndex":12,"outlineFt":[[-55.8854166,-5.8333334],[-56.1666666,1.25],[-56.1666666,12.8333333],[-56.1666666,22.1666666],[-55.9791666,22.1666666],[-55.9791666,37.5],[-56.1666666,37.5],[-56.1666666,46.8333333],[-57.1666666,46.8333333],[-57.1666666,37.5],[-57.3541666,37.5],[-57.3541666,22.1666666],[-57.1666666,22.1666666],[-57.1666666,12.8333333],[-57.1666666,1.25],[-57.4479166,-5.8333334]],"sourceHandles":["28784","28789","2878C","2878D","28C1F","28C20","28C25","28C26","28C27","28C28"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":213,"id":"upper-exterior-1-east-column-213","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":212,"columnIndex":11,"outlineFt":[[-59.21875,-5.8333334],[-59.5,1.25],[-59.5,12.8333333],[-59.7083333,12.8333333],[-59.7083333,22.1666666],[-59.7083333,37.5],[-59.7083333,46.8333333],[-60.2916666,46.8333333],[-60.2916666,37.5],[-60.2916666,22.1666666],[-60.2916666,12.8333333],[-60.5,12.8333333],[-60.5,1.25],[-60.78125,-5.8333334]],"sourceHandles":["2878A","2878F","28792","28793","28C1B","28C1C","28C23","28C24","28C3B","28C3C","28C42","28C43"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":212,"id":"upper-exterior-1-east-column-212","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":211,"columnIndex":10,"outlineFt":[[-62.5520833,-5.8333334],[-62.8333333,1.25],[-62.8333333,12.8333333],[-62.8333333,22.1666666],[-62.6458333,22.1666666],[-62.6458333,37.5],[-62.8333333,37.5],[-62.8333333,46.8333333],[-63.8333333,46.8333333],[-63.8333333,37.5],[-64.0208333,37.5],[-64.0208333,22.1666666],[-63.8333333,22.1666666],[-63.8333333,12.8333333],[-63.8333333,1.25],[-64.1145833,-5.8333334]],"sourceHandles":["28790","28795","28798","28799","28C4F","28C50","28C55","28C56","28C57","28C58"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":211,"id":"upper-exterior-1-east-column-211","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":210,"columnIndex":9,"outlineFt":[[-65.8854166,-5.8333334],[-66.1666666,1.25],[-66.1666666,12.8333333],[-66.375,12.8333333],[-66.375,22.1666666],[-66.375,37.5],[-66.375,46.8333333],[-66.9583333,46.8333333],[-66.9583333,37.5],[-66.9583333,22.1666666],[-66.9583333,12.8333333],[-67.1666666,12.8333333],[-67.1666666,1.25],[-67.4479166,-5.8333334]],"sourceHandles":["28796","2879B","2879E","2879F","28C4B","28C4C","28C53","28C54","28C6B","28C6C","28C72","28C73"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":210,"id":"upper-exterior-1-east-column-210","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":209,"columnIndex":8,"outlineFt":[[-69.21875,-5.8333334],[-69.5,1.25],[-69.5,12.8333333],[-69.5,22.1666666],[-69.3125,22.1666666],[-69.3125,37.5],[-69.5,37.5],[-69.5,46.8333333],[-70.5,46.8333333],[-70.5,37.5],[-70.6875,37.5],[-70.6875,22.1666666],[-70.5,22.1666666],[-70.5,12.8333333],[-70.5,1.25],[-70.78125,-5.8333334]],"sourceHandles":["2879C","287A1","287A4","287A5","28C7F","28C80","28C85","28C86","28C87","28C88"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":209,"id":"upper-exterior-1-east-column-209","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":208,"columnIndex":7,"outlineFt":[[-72.5520833,-5.8333334],[-72.8333333,1.25],[-72.8333333,12.8333333],[-73.0416666,12.8333333],[-73.0416666,22.1666666],[-73.0416666,37.5],[-73.0416666,46.8333333],[-73.625,46.8333333],[-73.625,37.5],[-73.625,22.1666666],[-73.625,12.8333333],[-73.8333333,12.8333333],[-73.8333333,1.25],[-74.1145833,-5.8333334]],"sourceHandles":["287A2","287A7","287AA","287AB","28C7B","28C7C","28C83","28C84","28C9B","28C9C","28CA2","28CA3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":208,"id":"upper-exterior-1-east-column-208","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":207,"columnIndex":6,"outlineFt":[[-75.8854166,-5.8333334],[-76.1666666,1.25],[-76.1666666,12.8333333],[-76.1666666,22.1666666],[-75.9791666,22.1666666],[-75.9791666,37.5],[-76.1666666,37.5],[-76.1666666,46.8333333],[-77.1666666,46.8333333],[-77.1666666,37.5],[-77.3541666,37.5],[-77.3541666,22.1666666],[-77.1666666,22.1666666],[-77.1666666,12.8333333],[-77.1666666,1.25],[-77.4479166,-5.8333334]],"sourceHandles":["287A8","287AD","287B0","287B1","28CAF","28CB0","28CB5","28CB6","28CB7","28CB8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":207,"id":"upper-exterior-1-east-column-207","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":206,"columnIndex":5,"outlineFt":[[-79.21875,-5.8333334],[-79.5,1.25],[-79.5,12.8333333],[-79.7083333,12.8333333],[-79.7083333,22.1666666],[-79.7083333,37.5],[-79.7083333,46.8333333],[-80.2916666,46.8333333],[-80.2916666,37.5],[-80.2916666,22.1666666],[-80.2916666,12.8333333],[-80.5,12.8333333],[-80.5,1.25],[-80.78125,-5.8333334]],"sourceHandles":["287AE","287B3","287B6","287B7","28CAB","28CAC","28CB3","28CB4","28CCB","28CCC","28CD2","28CD3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":206,"id":"upper-exterior-1-east-column-206","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":205,"columnIndex":4,"outlineFt":[[-82.5520833,-5.8333334],[-82.8333333,1.25],[-82.8333333,12.8333333],[-82.8333333,22.1666666],[-82.6458333,22.1666666],[-82.6458333,37.5],[-82.8333333,37.5],[-82.8333333,46.8333333],[-83.8333333,46.8333333],[-83.8333333,37.5],[-84.0208333,37.5],[-84.0208333,22.1666666],[-83.8333333,22.1666666],[-83.8333333,12.8333333],[-83.8333333,1.25],[-84.1145833,-5.8333334]],"sourceHandles":["287B4","287B9","287BC","287BD","28CDF","28CE0","28CE5","28CE6","28CE7","28CE8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":205,"id":"upper-exterior-1-east-column-205","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":204,"columnIndex":3,"outlineFt":[[-85.8854166,-5.8333334],[-86.1666666,1.25],[-86.1666666,12.8333333],[-86.375,12.8333333],[-86.375,22.1666666],[-86.375,37.5],[-86.375,46.8333333],[-86.9583333,46.8333333],[-86.9583333,37.5],[-86.9583333,22.1666666],[-86.9583333,12.8333333],[-87.1666666,12.8333333],[-87.1666666,1.25],[-87.4479166,-5.8333334]],"sourceHandles":["287BA","287BF","287C2","287C3","28CDB","28CDC","28CE3","28CE4","28CFB","28CFC","28D02","28D03"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":204,"id":"upper-exterior-1-east-column-204","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":203,"columnIndex":2,"outlineFt":[[-89.21875,-5.8333334],[-89.5,1.25],[-89.5,12.8333333],[-89.5,22.1666666],[-89.3125,22.1666666],[-89.3125,37.5],[-89.5,37.5],[-89.5,46.8333333],[-90.5,46.8333333],[-90.5,37.5],[-90.6875,37.5],[-90.6875,22.1666666],[-90.5,22.1666666],[-90.5,12.8333333],[-90.5,1.25],[-90.78125,-5.8333334]],"sourceHandles":["287C0","287C5","287C8","287C9","28D0F","28D10","28D15","28D16","28D17","28D18"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":203,"id":"upper-exterior-1-east-column-203","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":202,"columnIndex":1,"outlineFt":[[-92.5520833,-5.8333334],[-92.8333333,1.25],[-92.8333333,12.8333333],[-93.0416666,12.8333333],[-93.0416666,22.1666666],[-93.0416666,37.5],[-93.0416666,46.8333333],[-93.625,46.8333333],[-93.625,37.5],[-93.625,22.1666666],[-93.625,12.8333333],[-93.8333333,12.8333333],[-93.8333333,1.25],[-94.1145833,-5.8333334]],"sourceHandles":["287C6","287CB","287CD","287CE","28D0B","28D0C","28D13","28D14","28D2B","28D2C","28D32","28D33"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":202,"id":"upper-exterior-1-east-column-202","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":201,"columnIndex":0,"outlineFt":[[-95.8854166,-5.8333334],[-96.1170343,-0.0],[-96.1666666,1.25],[-96.1668614,1.25],[-96.1668614,17.5],[-96.1668614,17.5049035],[-96.1668614,22.1666666],[-95.9791666,22.1666666],[-95.9791666,37.5],[-96.1668614,37.5],[-96.1668614,49.0833333],[-98.375,49.0833333],[-98.375,37.5],[-98.375,22.1666666],[-98.375,17.5049035],[-98.375,17.5],[-98.375,1.25],[-98.375,-0.0],[-98.375,-5.8333334]],"sourceHandles":["287CF","287D0","287D1","287D3","287D5","287D6","287D7","28D41","28D43"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":201,"id":"upper-exterior-1-east-column-201","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[93.8333334,1.25],[94.1145834,-5.8333334],[95.8854167,-5.8333334],[96.1170343,-0.0],[96.1666667,1.25]],"sourceHandles":["2866A","2866B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-0","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[90.5,1.25],[90.78125,-5.8333334],[92.5520834,-5.8333334],[92.8333334,1.25]],"sourceHandles":["28669","2866F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-1","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[87.1666667,1.25],[87.4479167,-5.8333334],[89.21875,-5.8333334],[89.5,1.25]],"sourceHandles":["28680","28683"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-2","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[83.8333334,1.25],[84.1145834,-5.8333334],[85.8854167,-5.8333334],[86.1666667,1.25]],"sourceHandles":["28686","28689"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-3","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[80.5,1.25],[80.78125,-5.8333334],[82.5520834,-5.8333334],[82.8333334,1.25]],"sourceHandles":["2868C","2868F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-4","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[77.1666667,1.25],[77.4479167,-5.8333334],[79.21875,-5.8333334],[79.5,1.25]],"sourceHandles":["28692","28695"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-5","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[73.8333334,1.25],[74.1145834,-5.8333334],[75.8854167,-5.8333334],[76.1666667,1.25]],"sourceHandles":["28698","2869B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-6","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[70.5,1.25],[70.78125,-5.8333334],[72.5520834,-5.8333334],[72.8333334,1.25]],"sourceHandles":["2869E","286A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-7","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[67.1666667,1.25],[67.4479167,-5.8333334],[69.21875,-5.8333334],[69.5,1.25]],"sourceHandles":["286A4","286A7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-8","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[63.8333334,1.25],[64.1145834,-5.8333334],[65.8854167,-5.8333334],[66.1666667,1.25]],"sourceHandles":["286AA","286AD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-9","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[60.5,1.25],[60.78125,-5.8333334],[62.5520834,-5.8333334],[62.8333334,1.25]],"sourceHandles":["286B0","286B3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-10","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[57.1666667,1.25],[57.4479167,-5.8333334],[59.21875,-5.8333334],[59.5,1.25]],"sourceHandles":["286B6","286B9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-11","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[53.8333334,1.25],[54.1145834,-5.8333334],[55.8854167,-5.8333334],[56.1666667,1.25]],"sourceHandles":["286BC","286BF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-12","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[50.5,1.25],[50.78125,-5.8333334],[52.5520834,-5.8333334],[52.8333334,1.25]],"sourceHandles":["286C2","286C5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-13","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[47.1666667,1.25],[47.4479167,-5.8333334],[49.21875,-5.8333334],[49.5,1.25]],"sourceHandles":["286C8","286CB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-14","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[43.8333334,1.25],[44.1145834,-5.8333334],[45.8854167,-5.8333334],[46.1666667,1.25]],"sourceHandles":["286CE","286D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-15","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[40.5,1.25],[40.78125,-5.8333334],[42.5520834,-5.8333334],[42.8333334,1.25]],"sourceHandles":["286D4","286D7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-16","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[37.1666667,1.25],[37.4479167,-5.8333334],[39.21875,-5.8333334],[39.5,1.25]],"sourceHandles":["286DA","286DD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-17","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[33.8333334,1.25],[34.1145834,-5.8333334],[35.8854167,-5.8333334],[36.1666667,1.25]],"sourceHandles":["286E0","286E3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-18","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[30.5,1.25],[30.78125,-5.8333334],[32.5520834,-5.8333334],[32.8333334,1.25]],"sourceHandles":["286E6","286E9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-19","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[27.1666667,1.25],[27.4479167,-5.8333334],[29.21875,-5.8333334],[29.5,1.25]],"sourceHandles":["286EC","286EF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-20","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[23.8333334,1.25],[24.1145834,-5.8333334],[25.8854167,-5.8333334],[26.1666667,1.25]],"sourceHandles":["286F2","286F5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-21","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[20.5,1.25],[20.78125,-5.8333334],[22.5520834,-5.8333334],[22.8333334,1.25]],"sourceHandles":["286F8","286FB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-22","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[17.1666667,1.25],[17.4479167,-5.8333334],[19.21875,-5.8333334],[19.5,1.25]],"sourceHandles":["286FE","28701"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-23","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[13.8333334,1.25],[14.1145834,-5.8333334],[15.8854167,-5.8333334],[16.1666667,1.25]],"sourceHandles":["28704","28707"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-24","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[10.5,1.25],[10.78125,-5.8333334],[12.5520834,-5.8333334],[12.8333334,1.25]],"sourceHandles":["2870A","2870D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-25","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[7.1666667,1.25],[7.4479167,-5.8333334],[9.21875,-5.8333334],[9.5,1.25]],"sourceHandles":["28710","28713"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-26","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[3.8333334,1.25],[4.1145834,-5.8333334],[5.8854167,-5.8333334],[6.1666667,1.25]],"sourceHandles":["28716","28719"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-27","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[0.5,1.25],[0.78125,-5.8333334],[2.5520834,-5.8333334],[2.8333334,1.25]],"sourceHandles":["2871C","2871F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-28","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[-2.8333333,1.25],[-2.5520833,-5.8333334],[-0.78125,-5.8333334],[-0.5,1.25]],"sourceHandles":["28722","28725"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-29","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[-6.1666666,1.25],[-5.8854166,-5.8333334],[-4.1145833,-5.8333334],[-3.8333333,1.25]],"sourceHandles":["28728","2872B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-30","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[-9.5,1.25],[-9.21875,-5.8333334],[-7.4479166,-5.8333334],[-7.1666666,1.25]],"sourceHandles":["2872E","28731"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-31","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[-12.8333333,1.25],[-12.5520833,-5.8333334],[-10.78125,-5.8333334],[-10.5,1.25]],"sourceHandles":["28734","28737"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-32","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[-16.1666666,1.25],[-15.8854166,-5.8333334],[-14.1145833,-5.8333334],[-13.8333333,1.25]],"sourceHandles":["2873A","2873D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-33","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[-19.5,1.25],[-19.21875,-5.8333334],[-17.4479166,-5.8333334],[-17.1666666,1.25]],"sourceHandles":["28740","28743"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-34","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[-22.8333333,1.25],[-22.5520833,-5.8333334],[-20.78125,-5.8333334],[-20.5,1.25]],"sourceHandles":["28746","28749"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-35","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[-26.1666666,1.25],[-25.8854166,-5.8333334],[-24.1145833,-5.8333334],[-23.8333333,1.25]],"sourceHandles":["2874C","2874F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-36","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[-29.5,1.25],[-29.21875,-5.8333334],[-27.4479166,-5.8333334],[-27.1666666,1.25]],"sourceHandles":["28752","28755"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-37","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[-32.8333333,1.25],[-32.5520833,-5.8333334],[-30.78125,-5.8333334],[-30.5,1.25]],"sourceHandles":["28758","2875B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-38","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[-36.1666666,1.25],[-35.8854166,-5.8333334],[-34.1145833,-5.8333334],[-33.8333333,1.25]],"sourceHandles":["2875E","28761"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-39","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[-39.5,1.25],[-39.21875,-5.8333334],[-37.4479166,-5.8333334],[-37.1666666,1.25]],"sourceHandles":["28764","28767"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-40","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[-42.8333333,1.25],[-42.5520833,-5.8333334],[-40.78125,-5.8333334],[-40.5,1.25]],"sourceHandles":["2876A","2876D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-41","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[-46.1666666,1.25],[-45.8854166,-5.8333334],[-44.1145833,-5.8333334],[-43.8333333,1.25]],"sourceHandles":["28770","28773"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-42","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[-49.5,1.25],[-49.21875,-5.8333334],[-47.4479166,-5.8333334],[-47.1666666,1.25]],"sourceHandles":["28776","28779"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-43","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[-52.8333333,1.25],[-52.5520833,-5.8333334],[-50.78125,-5.8333334],[-50.5,1.25]],"sourceHandles":["2877C","2877F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-44","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[-56.1666666,1.25],[-55.8854166,-5.8333334],[-54.1145833,-5.8333334],[-53.8333333,1.25]],"sourceHandles":["28782","28785"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-45","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[-59.5,1.25],[-59.21875,-5.8333334],[-57.4479166,-5.8333334],[-57.1666666,1.25]],"sourceHandles":["28788","2878B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-46","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[-62.8333333,1.25],[-62.5520833,-5.8333334],[-60.78125,-5.8333334],[-60.5,1.25]],"sourceHandles":["2878E","28791"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-47","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[-66.1666666,1.25],[-65.8854166,-5.8333334],[-64.1145833,-5.8333334],[-63.8333333,1.25]],"sourceHandles":["28794","28797"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-48","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[-69.5,1.25],[-69.21875,-5.8333334],[-67.4479166,-5.8333334],[-67.1666666,1.25]],"sourceHandles":["2879A","2879D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-49","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[-72.8333333,1.25],[-72.5520833,-5.8333334],[-70.78125,-5.8333334],[-70.5,1.25]],"sourceHandles":["287A0","287A3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-50","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[-76.1666666,1.25],[-75.8854166,-5.8333334],[-74.1145833,-5.8333334],[-73.8333333,1.25]],"sourceHandles":["287A6","287A9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-51","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[-79.5,1.25],[-79.21875,-5.8333334],[-77.4479166,-5.8333334],[-77.1666666,1.25]],"sourceHandles":["287AC","287AF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-52","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[-82.8333333,1.25],[-82.5520833,-5.8333334],[-80.78125,-5.8333334],[-80.5,1.25]],"sourceHandles":["287B2","287B5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-53","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[-86.1666666,1.25],[-85.8854166,-5.8333334],[-84.1145833,-5.8333334],[-83.8333333,1.25]],"sourceHandles":["287B8","287BB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-54","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[-89.5,1.25],[-89.21875,-5.8333334],[-87.4479166,-5.8333334],[-87.1666666,1.25]],"sourceHandles":["287BE","287C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-55","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[-92.8333333,1.25],[-92.5520833,-5.8333334],[-90.78125,-5.8333334],[-90.5,1.25]],"sourceHandles":["287C4","287C7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-56","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[-96.1666666,1.25],[-96.1170343,-0.0],[-95.8854166,-5.8333334],[-94.1145833,-5.8333334],[-93.8333333,1.25]],"sourceHandles":["287CA","287CC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-107-57","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[93.625,18.8333333],[93.625,12.8333333],[93.8333334,12.8333333],[96.1666667,12.8333333],[96.1666667,17.5],[96.1666667,18.8333333]],"sourceHandles":["287E0","287E1","287FE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-0","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[90.5,18.8333333],[90.5,12.8333333],[92.8333334,12.8333333],[93.0416667,12.8333333],[93.0416667,18.8333333]],"sourceHandles":["287FC","287FD","28800"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-1","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[86.9583334,18.8333333],[86.9583334,12.8333333],[87.1666667,12.8333333],[89.5,12.8333333],[89.5,18.8333333]],"sourceHandles":["287FA","287FB","28801"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-2","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[83.8333334,18.8333333],[83.8333334,12.8333333],[86.1666667,12.8333333],[86.375,12.8333333],[86.375,18.8333333]],"sourceHandles":["28841","28842","28843"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-3","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[80.2916667,18.8333333],[80.2916667,12.8333333],[80.5,12.8333333],[82.8333334,12.8333333],[82.8333334,18.8333333]],"sourceHandles":["2883F","28840","28844"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-4","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[77.1666667,18.8333333],[77.1666667,12.8333333],[79.5,12.8333333],[79.7083334,12.8333333],[79.7083334,18.8333333]],"sourceHandles":["28871","28872","28873"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-5","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[73.625,18.8333333],[73.625,12.8333333],[73.8333334,12.8333333],[76.1666667,12.8333333],[76.1666667,18.8333333]],"sourceHandles":["2886F","28870","28874"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-6","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[70.5,18.8333333],[70.5,12.8333333],[72.8333334,12.8333333],[73.0416667,12.8333333],[73.0416667,18.8333333]],"sourceHandles":["288A1","288A2","288A3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-7","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[66.9583334,18.8333333],[66.9583334,12.8333333],[67.1666667,12.8333333],[69.5,12.8333333],[69.5,18.8333333]],"sourceHandles":["2889F","288A0","288A4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-8","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[63.8333334,18.8333333],[63.8333334,12.8333333],[66.1666667,12.8333333],[66.375,12.8333333],[66.375,18.8333333]],"sourceHandles":["288D1","288D2","288D3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-9","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[60.2916667,18.8333333],[60.2916667,12.8333333],[60.5,12.8333333],[62.8333334,12.8333333],[62.8333334,18.8333333]],"sourceHandles":["288CF","288D0","288D4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-10","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[57.1666667,18.8333333],[57.1666667,12.8333333],[59.5,12.8333333],[59.7083334,12.8333333],[59.7083334,18.8333333]],"sourceHandles":["28901","28902","28903"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-11","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[53.625,18.8333333],[53.625,12.8333333],[53.8333334,12.8333333],[56.1666667,12.8333333],[56.1666667,18.8333333]],"sourceHandles":["288FF","28900","28904"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-12","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[50.5,18.8333333],[50.5,12.8333333],[52.8333334,12.8333333],[53.0416667,12.8333333],[53.0416667,18.8333333]],"sourceHandles":["28931","28932","28933"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-13","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[46.9583334,18.8333333],[46.9583334,12.8333333],[47.1666667,12.8333333],[49.5,12.8333333],[49.5,18.8333333]],"sourceHandles":["2892F","28930","28934"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-14","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[43.8333334,18.8333333],[43.8333334,12.8333333],[46.1666667,12.8333333],[46.375,12.8333333],[46.375,18.8333333]],"sourceHandles":["28961","28962","28963"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-15","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[40.2916667,18.8333333],[40.2916667,12.8333333],[40.5,12.8333333],[42.8333334,12.8333333],[42.8333334,18.8333333]],"sourceHandles":["2895F","28960","28964"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-16","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[37.1666667,18.8333333],[37.1666667,12.8333333],[39.5,12.8333333],[39.7083334,12.8333333],[39.7083334,18.8333333]],"sourceHandles":["28991","28992","28993"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-17","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[33.625,18.8333333],[33.625,12.8333333],[33.8333334,12.8333333],[36.1666667,12.8333333],[36.1666667,18.8333333]],"sourceHandles":["2898F","28990","28994"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-18","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[30.5,18.8333333],[30.5,12.8333333],[32.8333334,12.8333333],[33.0416667,12.8333333],[33.0416667,18.8333333]],"sourceHandles":["289C1","289C2","289C3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-19","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[26.9583334,18.8333333],[26.9583334,12.8333333],[27.1666667,12.8333333],[29.5,12.8333333],[29.5,18.8333333]],"sourceHandles":["289BF","289C0","289C4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-20","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[23.8333334,18.8333333],[23.8333334,12.8333333],[26.1666667,12.8333333],[26.375,12.8333333],[26.375,18.8333333]],"sourceHandles":["289F1","289F2","289F3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-21","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[20.2916667,18.8333333],[20.2916667,12.8333333],[20.5,12.8333333],[22.8333334,12.8333333],[22.8333334,18.8333333]],"sourceHandles":["289EF","289F0","289F4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-22","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[17.1666667,18.8333333],[17.1666667,12.8333333],[19.5,12.8333333],[19.7083334,12.8333333],[19.7083334,18.8333333]],"sourceHandles":["28A21","28A22","28A23"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-23","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[13.625,18.8333333],[13.625,12.8333333],[13.8333334,12.8333333],[16.1666667,12.8333333],[16.1666667,18.8333333]],"sourceHandles":["28A1F","28A20","28A24"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-24","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[10.5,18.8333333],[10.5,12.8333333],[12.8333334,12.8333333],[13.0416667,12.8333333],[13.0416667,18.8333333]],"sourceHandles":["28A51","28A52","28A53"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-25","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[6.9583334,18.8333333],[6.9583334,12.8333333],[7.1666667,12.8333333],[9.5,12.8333333],[9.5,18.8333333]],"sourceHandles":["28A4F","28A50","28A54"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-26","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[3.8333334,18.8333333],[3.8333334,12.8333333],[6.1666667,12.8333333],[6.375,12.8333333],[6.375,18.8333333]],"sourceHandles":["28A81","28A82","28A83"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-27","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[0.2916667,18.8333333],[0.2916667,12.8333333],[0.5,12.8333333],[2.8333334,12.8333333],[2.8333334,18.8333333]],"sourceHandles":["28A7F","28A80","28A84"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-28","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[-2.8333333,18.8333333],[-2.8333333,12.8333333],[-0.5,12.8333333],[-0.2916666,12.8333333],[-0.2916666,18.8333333]],"sourceHandles":["28AB1","28AB2","28AB3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-29","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[-6.375,18.8333333],[-6.375,12.8333333],[-6.1666666,12.8333333],[-3.8333333,12.8333333],[-3.8333333,18.8333333]],"sourceHandles":["28AAF","28AB0","28AB4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-30","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[-9.5,18.8333333],[-9.5,12.8333333],[-7.1666666,12.8333333],[-6.9583333,12.8333333],[-6.9583333,18.8333333]],"sourceHandles":["28AE1","28AE2","28AE3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-31","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[-13.0416666,18.8333333],[-13.0416666,12.8333333],[-12.8333333,12.8333333],[-10.5,12.8333333],[-10.5,18.8333333]],"sourceHandles":["28ADF","28AE0","28AE4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-32","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[-16.1666666,18.8333333],[-16.1666666,12.8333333],[-13.8333333,12.8333333],[-13.625,12.8333333],[-13.625,18.8333333]],"sourceHandles":["28B11","28B12","28B13"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-33","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[-19.7083333,18.8333333],[-19.7083333,12.8333333],[-19.5,12.8333333],[-17.1666666,12.8333333],[-17.1666666,18.8333333]],"sourceHandles":["28B0F","28B10","28B14"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-34","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[-22.8333333,18.8333333],[-22.8333333,12.8333333],[-20.5,12.8333333],[-20.2916666,12.8333333],[-20.2916666,18.8333333]],"sourceHandles":["28B41","28B42","28B43"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-35","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[-26.375,18.8333333],[-26.375,12.8333333],[-26.1666666,12.8333333],[-23.8333333,12.8333333],[-23.8333333,18.8333333]],"sourceHandles":["28B3F","28B40","28B44"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-36","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[-29.5,18.8333333],[-29.5,12.8333333],[-27.1666666,12.8333333],[-26.9583333,12.8333333],[-26.9583333,18.8333333]],"sourceHandles":["28B71","28B72","28B73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-37","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[-33.0416666,18.8333333],[-33.0416666,12.8333333],[-32.8333333,12.8333333],[-30.5,12.8333333],[-30.5,18.8333333]],"sourceHandles":["28B6F","28B70","28B74"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-38","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[-36.1666666,18.8333333],[-36.1666666,12.8333333],[-33.8333333,12.8333333],[-33.625,12.8333333],[-33.625,18.8333333]],"sourceHandles":["28BA1","28BA2","28BA3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-39","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[-39.7083333,18.8333333],[-39.7083333,12.8333333],[-39.5,12.8333333],[-37.1666666,12.8333333],[-37.1666666,18.8333333]],"sourceHandles":["28B9F","28BA0","28BA4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-40","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[-42.8333333,18.8333333],[-42.8333333,12.8333333],[-40.5,12.8333333],[-40.2916666,12.8333333],[-40.2916666,18.8333333]],"sourceHandles":["28BD1","28BD2","28BD3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-41","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[-46.375,18.8333333],[-46.375,12.8333333],[-46.1666666,12.8333333],[-43.8333333,12.8333333],[-43.8333333,18.8333333]],"sourceHandles":["28BCF","28BD0","28BD4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-42","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[-49.5,18.8333333],[-49.5,12.8333333],[-47.1666666,12.8333333],[-46.9583333,12.8333333],[-46.9583333,18.8333333]],"sourceHandles":["28C01","28C02","28C03"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-43","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[-53.0416666,18.8333333],[-53.0416666,12.8333333],[-52.8333333,12.8333333],[-50.5,12.8333333],[-50.5,18.8333333]],"sourceHandles":["28BFF","28C00","28C04"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-44","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[-56.1666666,18.8333333],[-56.1666666,12.8333333],[-53.8333333,12.8333333],[-53.625,12.8333333],[-53.625,18.8333333]],"sourceHandles":["28C31","28C32","28C33"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-45","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[-59.7083333,18.8333333],[-59.7083333,12.8333333],[-59.5,12.8333333],[-57.1666666,12.8333333],[-57.1666666,18.8333333]],"sourceHandles":["28C2F","28C30","28C34"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-46","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[-62.8333333,18.8333333],[-62.8333333,12.8333333],[-60.5,12.8333333],[-60.2916666,12.8333333],[-60.2916666,18.8333333]],"sourceHandles":["28C61","28C62","28C63"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-47","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[-66.375,18.8333333],[-66.375,12.8333333],[-66.1666666,12.8333333],[-63.8333333,12.8333333],[-63.8333333,18.8333333]],"sourceHandles":["28C5F","28C60","28C64"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-48","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[-69.5,18.8333333],[-69.5,12.8333333],[-67.1666666,12.8333333],[-66.9583333,12.8333333],[-66.9583333,18.8333333]],"sourceHandles":["28C91","28C92","28C93"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-49","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[-73.0416666,18.8333333],[-73.0416666,12.8333333],[-72.8333333,12.8333333],[-70.5,12.8333333],[-70.5,18.8333333]],"sourceHandles":["28C8F","28C90","28C94"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-50","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[-76.1666666,18.8333333],[-76.1666666,12.8333333],[-73.8333333,12.8333333],[-73.625,12.8333333],[-73.625,18.8333333]],"sourceHandles":["28CC1","28CC2","28CC3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-51","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[-79.7083333,18.8333333],[-79.7083333,12.8333333],[-79.5,12.8333333],[-77.1666666,12.8333333],[-77.1666666,18.8333333]],"sourceHandles":["28CBF","28CC0","28CC4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-52","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[-82.8333333,18.8333333],[-82.8333333,12.8333333],[-80.5,12.8333333],[-80.2916666,12.8333333],[-80.2916666,18.8333333]],"sourceHandles":["28CF1","28CF2","28CF3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-53","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[-86.375,18.8333333],[-86.375,12.8333333],[-86.1666666,12.8333333],[-83.8333333,12.8333333],[-83.8333333,18.8333333]],"sourceHandles":["28CEF","28CF0","28CF4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-54","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[-89.5,18.8333333],[-89.5,12.8333333],[-87.1666666,12.8333333],[-86.9583333,12.8333333],[-86.9583333,18.8333333]],"sourceHandles":["28D21","28D22","28D23"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-55","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[-93.0416666,18.8333333],[-93.0416666,12.8333333],[-92.8333333,12.8333333],[-90.5,12.8333333],[-90.5,18.8333333]],"sourceHandles":["28D1F","28D20","28D24"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-56","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[-96.1668614,18.8333333],[-96.1668614,17.5049035],[-96.1668614,17.5],[-96.1668614,12.8333333],[-93.8333333,12.8333333],[-93.625,12.8333333],[-93.625,18.8333333]],"sourceHandles":["28D46","28D47","28D48"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-108-57","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[93.625,46.8333333],[93.625,39.5833333],[96.1666667,39.5833333],[96.1666667,46.8333333]],"sourceHandles":["28802","28810","28DBA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-0","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[90.5,46.8333333],[90.5,39.5833333],[93.0416667,39.5833333],[93.0416667,46.8333333]],"sourceHandles":["2880A","28811","28812"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-1","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[86.9583334,46.8333333],[86.9583334,39.5833333],[89.5,39.5833333],[89.5,46.8333333]],"sourceHandles":["2880B","28813","28814"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-2","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[83.8333334,46.8333333],[83.8333334,39.5833333],[86.375,39.5833333],[86.375,46.8333333]],"sourceHandles":["28815","28849","28D4D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-3","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[80.2916667,46.8333333],[80.2916667,39.5833333],[82.8333334,39.5833333],[82.8333334,46.8333333]],"sourceHandles":["2884A","28D4E","28D4F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-4","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[77.1666667,46.8333333],[77.1666667,39.5833333],[79.7083334,39.5833333],[79.7083334,46.8333333]],"sourceHandles":["28879","28D50","28D51"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-5","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[73.625,46.8333333],[73.625,39.5833333],[76.1666667,39.5833333],[76.1666667,46.8333333]],"sourceHandles":["2887A","28D52","28D53"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-6","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[70.5,46.8333333],[70.5,39.5833333],[73.0416667,39.5833333],[73.0416667,46.8333333]],"sourceHandles":["288A9","28D54","28D55"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-7","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[66.9583334,46.8333333],[66.9583334,39.5833333],[69.5,39.5833333],[69.5,46.8333333]],"sourceHandles":["288AA","28D56","28D57"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-8","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[63.8333334,46.8333333],[63.8333334,39.5833333],[66.375,39.5833333],[66.375,46.8333333]],"sourceHandles":["288D9","28D58","28D59"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-9","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[60.2916667,46.8333333],[60.2916667,39.5833333],[62.8333334,39.5833333],[62.8333334,46.8333333]],"sourceHandles":["288DA","28D5A","28D5B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-10","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[57.1666667,46.8333333],[57.1666667,39.5833333],[59.7083334,39.5833333],[59.7083334,46.8333333]],"sourceHandles":["28909","28D5C","28D5D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-11","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[53.625,46.8333333],[53.625,39.5833333],[56.1666667,39.5833333],[56.1666667,46.8333333]],"sourceHandles":["2890A","28D5E","28D5F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-12","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[50.5,46.8333333],[50.5,39.5833333],[53.0416667,39.5833333],[53.0416667,46.8333333]],"sourceHandles":["28939","28D60","28D61"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-13","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[46.9583334,46.8333333],[46.9583334,39.5833333],[49.5,39.5833333],[49.5,46.8333333]],"sourceHandles":["2893A","28D62","28D63"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-14","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[43.8333334,46.8333333],[43.8333334,39.5833333],[46.375,39.5833333],[46.375,46.8333333]],"sourceHandles":["28969","28D64","28D65"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-15","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[40.2916667,46.8333333],[40.2916667,39.5833333],[42.8333334,39.5833333],[42.8333334,46.8333333]],"sourceHandles":["2896A","28D66","28D67"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-16","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[37.1666667,46.8333333],[37.1666667,39.5833333],[39.7083334,39.5833333],[39.7083334,46.8333333]],"sourceHandles":["28999","28D68","28D69"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-17","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[33.625,46.8333333],[33.625,39.5833333],[36.1666667,39.5833333],[36.1666667,46.8333333]],"sourceHandles":["2899A","28D6A","28D6B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-18","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[30.5,46.8333333],[30.5,39.5833333],[33.0416667,39.5833333],[33.0416667,46.8333333]],"sourceHandles":["289C9","28D6C","28D6D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-19","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[26.9583334,46.8333333],[26.9583334,39.5833333],[29.5,39.5833333],[29.5,46.8333333]],"sourceHandles":["289CA","28D6E","28D6F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-20","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[23.8333334,46.8333333],[23.8333334,39.5833333],[26.375,39.5833333],[26.375,46.8333333]],"sourceHandles":["289F9","28D70","28D71"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-21","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[20.2916667,46.8333333],[20.2916667,39.5833333],[22.8333334,39.5833333],[22.8333334,46.8333333]],"sourceHandles":["289FA","28D72","28D73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-22","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[17.1666667,46.8333333],[17.1666667,39.5833333],[19.7083334,39.5833333],[19.7083334,46.8333333]],"sourceHandles":["28A29","28D74","28D75"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-23","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[13.625,46.8333333],[13.625,39.5833333],[16.1666667,39.5833333],[16.1666667,46.8333333]],"sourceHandles":["28A2A","28D76","28D77"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-24","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[10.5,46.8333333],[10.5,39.5833333],[13.0416667,39.5833333],[13.0416667,46.8333333]],"sourceHandles":["28A59","28D78","28D79"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-25","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[6.9583334,46.8333333],[6.9583334,39.5833333],[9.5,39.5833333],[9.5,46.8333333]],"sourceHandles":["28A5A","28D7A","28D7B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-26","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[3.8333334,46.8333333],[3.8333334,39.5833333],[6.375,39.5833333],[6.375,46.8333333]],"sourceHandles":["28A89","28D7C","28D7D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-27","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[0.2916667,46.8333333],[0.2916667,39.5833333],[2.8333334,39.5833333],[2.8333334,46.8333333]],"sourceHandles":["28A8A","28D7E","28D7F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-28","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[-2.8333333,46.8333333],[-2.8333333,39.5833333],[-0.2916666,39.5833333],[-0.2916666,46.8333333]],"sourceHandles":["28AB9","28D80","28D81"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-29","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[-6.375,46.8333333],[-6.375,39.5833333],[-3.8333333,39.5833333],[-3.8333333,46.8333333]],"sourceHandles":["28ABA","28D82","28D83"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-30","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[-9.5,46.8333333],[-9.5,39.5833333],[-6.9583333,39.5833333],[-6.9583333,46.8333333]],"sourceHandles":["28AE9","28D84","28D85"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-31","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[-13.0416666,46.8333333],[-13.0416666,39.5833333],[-10.5,39.5833333],[-10.5,46.8333333]],"sourceHandles":["28AEA","28D86","28D87"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-32","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[-16.1666666,46.8333333],[-16.1666666,39.5833333],[-13.625,39.5833333],[-13.625,46.8333333]],"sourceHandles":["28B19","28D88","28D89"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-33","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[-19.7083333,46.8333333],[-19.7083333,39.5833333],[-17.1666666,39.5833333],[-17.1666666,46.8333333]],"sourceHandles":["28B1A","28D8A","28D8B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-34","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[-22.8333333,46.8333333],[-22.8333333,39.5833333],[-20.2916666,39.5833333],[-20.2916666,46.8333333]],"sourceHandles":["28B49","28D8C","28D8D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-35","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[-26.375,46.8333333],[-26.375,39.5833333],[-23.8333333,39.5833333],[-23.8333333,46.8333333]],"sourceHandles":["28B4A","28D8E","28D8F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-36","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[-29.5,46.8333333],[-29.5,39.5833333],[-26.9583333,39.5833333],[-26.9583333,46.8333333]],"sourceHandles":["28B79","28D90","28D91"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-37","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[-33.0416666,46.8333333],[-33.0416666,39.5833333],[-30.5,39.5833333],[-30.5,46.8333333]],"sourceHandles":["28B7A","28D92","28D93"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-38","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[-36.1666666,46.8333333],[-36.1666666,39.5833333],[-33.625,39.5833333],[-33.625,46.8333333]],"sourceHandles":["28BA9","28D94","28D95"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-39","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[-39.7083333,46.8333333],[-39.7083333,39.5833333],[-37.1666666,39.5833333],[-37.1666666,46.8333333]],"sourceHandles":["28BAA","28D96","28D97"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-40","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[-42.8333333,46.8333333],[-42.8333333,39.5833333],[-40.2916666,39.5833333],[-40.2916666,46.8333333]],"sourceHandles":["28BD9","28D98","28D99"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-41","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[-46.375,46.8333333],[-46.375,39.5833333],[-43.8333333,39.5833333],[-43.8333333,46.8333333]],"sourceHandles":["28BDA","28D9A","28D9B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-42","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[-49.5,46.8333333],[-49.5,39.5833333],[-46.9583333,39.5833333],[-46.9583333,46.8333333]],"sourceHandles":["28C09","28D9C","28D9D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-43","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[-53.0416666,46.8333333],[-53.0416666,39.5833333],[-50.5,39.5833333],[-50.5,46.8333333]],"sourceHandles":["28C0A","28D9E","28D9F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-44","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[-56.1666666,46.8333333],[-56.1666666,39.5833333],[-53.625,39.5833333],[-53.625,46.8333333]],"sourceHandles":["28C39","28DA0","28DA1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-45","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[-59.7083333,46.8333333],[-59.7083333,39.5833333],[-57.1666666,39.5833333],[-57.1666666,46.8333333]],"sourceHandles":["28C3A","28DA2","28DA3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-46","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[-62.8333333,46.8333333],[-62.8333333,39.5833333],[-60.2916666,39.5833333],[-60.2916666,46.8333333]],"sourceHandles":["28C69","28DA4","28DA5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-47","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[-66.375,46.8333333],[-66.375,39.5833333],[-63.8333333,39.5833333],[-63.8333333,46.8333333]],"sourceHandles":["28C6A","28DA6","28DA7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-48","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[-69.5,46.8333333],[-69.5,39.5833333],[-66.9583333,39.5833333],[-66.9583333,46.8333333]],"sourceHandles":["28C99","28DA8","28DA9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-49","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[-73.0416666,46.8333333],[-73.0416666,39.5833333],[-70.5,39.5833333],[-70.5,46.8333333]],"sourceHandles":["28C9A","28DAA","28DAB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-50","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[-76.1666666,46.8333333],[-76.1666666,39.5833333],[-73.625,39.5833333],[-73.625,46.8333333]],"sourceHandles":["28CC9","28DAC","28DAD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-51","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[-79.7083333,46.8333333],[-79.7083333,39.5833333],[-77.1666666,39.5833333],[-77.1666666,46.8333333]],"sourceHandles":["28CCA","28DAE","28DAF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-52","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[-82.8333333,46.8333333],[-82.8333333,39.5833333],[-80.2916666,39.5833333],[-80.2916666,46.8333333]],"sourceHandles":["28CF9","28DB0","28DB1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-53","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[-86.375,46.8333333],[-86.375,39.5833333],[-83.8333333,39.5833333],[-83.8333333,46.8333333]],"sourceHandles":["28CFA","28DB2","28DB3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-54","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[-89.5,46.8333333],[-89.5,39.5833333],[-86.9583333,39.5833333],[-86.9583333,46.8333333]],"sourceHandles":["28D29","28DB4","28DB5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-55","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[-93.0416666,46.8333333],[-93.0416666,39.5833333],[-90.5,39.5833333],[-90.5,46.8333333]],"sourceHandles":["28D2A","28DB6","28DB7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-56","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[-96.1668614,46.8333333],[-96.1668614,39.5833333],[-93.625,39.5833333],[-93.625,46.8333333]],"sourceHandles":["28DB8","28DB9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-east-spandrel-110-57","tower":1,"face":"east","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":359,"columnIndex":58,"outlineFt":[[98.375,-5.8333334],[98.375,-0.0],[98.375,1.25],[98.375,17.5],[98.375,22.1666666],[98.375,37.5],[98.375,49.0833333],[96.1666667,49.0833333],[96.1666667,37.5],[95.9791667,37.5],[95.9791667,22.1666666],[96.1666667,22.1666666],[96.1666667,17.5],[96.1666667,1.25],[96.1170343,-0.0],[95.8854167,-5.8333334]],"sourceHandles":["28672","28674","2867B","2867C","2867F","28D3B","28D3C","28D40"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":259,"id":"upper-exterior-2-east-column-359","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":358,"columnIndex":57,"outlineFt":[[94.1145834,-5.8333334],[93.8333334,1.25],[93.8333334,12.8333333],[93.625,12.8333333],[93.625,22.1666666],[93.625,37.5],[93.625,46.8333333],[93.0416667,46.8333333],[93.0416667,37.5],[93.0416667,22.1666666],[93.0416667,12.8333333],[92.8333334,12.8333333],[92.8333334,1.25],[92.5520834,-5.8333334]],"sourceHandles":["2866C","2866D","28670","28671","287F4","287F5","287F8","287F9","2880C","2880D","28825","28826"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":258,"id":"upper-exterior-2-east-column-358","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":357,"columnIndex":56,"outlineFt":[[90.78125,-5.8333334],[90.5,1.25],[90.5,12.8333333],[90.5,22.1666666],[90.6875,22.1666666],[90.6875,37.5],[90.5,37.5],[90.5,46.8333333],[89.5,46.8333333],[89.5,37.5],[89.3125,37.5],[89.3125,22.1666666],[89.5,22.1666666],[89.5,12.8333333],[89.5,1.25],[89.21875,-5.8333334]],"sourceHandles":["2866E","28681","28684","28685","287E4","287E5","287EA","287EB","287EC","287ED"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":257,"id":"upper-exterior-2-east-column-357","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":356,"columnIndex":55,"outlineFt":[[87.4479167,-5.8333334],[87.1666667,1.25],[87.1666667,12.8333333],[86.9583334,12.8333333],[86.9583334,22.1666666],[86.9583334,37.5],[86.9583334,46.8333333],[86.375,46.8333333],[86.375,37.5],[86.375,22.1666666],[86.375,12.8333333],[86.1666667,12.8333333],[86.1666667,1.25],[85.8854167,-5.8333334]],"sourceHandles":["28682","28687","2868A","2868B","287DE","287DF","287E8","287E9","2880E","2880F","2881B","2881C"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":256,"id":"upper-exterior-2-east-column-356","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":355,"columnIndex":54,"outlineFt":[[84.1145834,-5.8333334],[83.8333334,1.25],[83.8333334,12.8333333],[83.8333334,22.1666666],[84.0208334,22.1666666],[84.0208334,37.5],[83.8333334,37.5],[83.8333334,46.8333333],[82.8333334,46.8333333],[82.8333334,37.5],[82.6458334,37.5],[82.6458334,22.1666666],[82.8333334,22.1666666],[82.8333334,12.8333333],[82.8333334,1.25],[82.5520834,-5.8333334]],"sourceHandles":["28688","2868D","28690","28691","2882F","28830","28835","28836","28837","28838"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":255,"id":"upper-exterior-2-east-column-355","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":354,"columnIndex":53,"outlineFt":[[80.78125,-5.8333334],[80.5,1.25],[80.5,12.8333333],[80.2916667,12.8333333],[80.2916667,22.1666666],[80.2916667,37.5],[80.2916667,46.8333333],[79.7083334,46.8333333],[79.7083334,37.5],[79.7083334,22.1666666],[79.7083334,12.8333333],[79.5,12.8333333],[79.5,1.25],[79.21875,-5.8333334]],"sourceHandles":["2868E","28693","28696","28697","2882B","2882C","28833","28834","2884B","2884C","28852","28853"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":254,"id":"upper-exterior-2-east-column-354","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":353,"columnIndex":52,"outlineFt":[[77.4479167,-5.8333334],[77.1666667,1.25],[77.1666667,12.8333333],[77.1666667,22.1666666],[77.3541667,22.1666666],[77.3541667,37.5],[77.1666667,37.5],[77.1666667,46.8333333],[76.1666667,46.8333333],[76.1666667,37.5],[75.9791667,37.5],[75.9791667,22.1666666],[76.1666667,22.1666666],[76.1666667,12.8333333],[76.1666667,1.25],[75.8854167,-5.8333334]],"sourceHandles":["28694","28699","2869C","2869D","2885F","28860","28865","28866","28867","28868"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":253,"id":"upper-exterior-2-east-column-353","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":352,"columnIndex":51,"outlineFt":[[74.1145834,-5.8333334],[73.8333334,1.25],[73.8333334,12.8333333],[73.625,12.8333333],[73.625,22.1666666],[73.625,37.5],[73.625,46.8333333],[73.0416667,46.8333333],[73.0416667,37.5],[73.0416667,22.1666666],[73.0416667,12.8333333],[72.8333334,12.8333333],[72.8333334,1.25],[72.5520834,-5.8333334]],"sourceHandles":["2869A","2869F","286A2","286A3","2885B","2885C","28863","28864","2887B","2887C","28882","28883"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":252,"id":"upper-exterior-2-east-column-352","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":351,"columnIndex":50,"outlineFt":[[70.78125,-5.8333334],[70.5,1.25],[70.5,12.8333333],[70.5,22.1666666],[70.6875,22.1666666],[70.6875,37.5],[70.5,37.5],[70.5,46.8333333],[69.5,46.8333333],[69.5,37.5],[69.3125,37.5],[69.3125,22.1666666],[69.5,22.1666666],[69.5,12.8333333],[69.5,1.25],[69.21875,-5.8333334]],"sourceHandles":["286A0","286A5","286A8","286A9","2888F","28890","28895","28896","28897","28898"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":251,"id":"upper-exterior-2-east-column-351","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":350,"columnIndex":49,"outlineFt":[[67.4479167,-5.8333334],[67.1666667,1.25],[67.1666667,12.8333333],[66.9583334,12.8333333],[66.9583334,22.1666666],[66.9583334,37.5],[66.9583334,46.8333333],[66.375,46.8333333],[66.375,37.5],[66.375,22.1666666],[66.375,12.8333333],[66.1666667,12.8333333],[66.1666667,1.25],[65.8854167,-5.8333334]],"sourceHandles":["286A6","286AB","286AE","286AF","2888B","2888C","28893","28894","288AB","288AC","288B2","288B3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":250,"id":"upper-exterior-2-east-column-350","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":349,"columnIndex":48,"outlineFt":[[64.1145834,-5.8333334],[63.8333334,1.25],[63.8333334,12.8333333],[63.8333334,22.1666666],[64.0208334,22.1666666],[64.0208334,37.5],[63.8333334,37.5],[63.8333334,46.8333333],[62.8333334,46.8333333],[62.8333334,37.5],[62.6458334,37.5],[62.6458334,22.1666666],[62.8333334,22.1666666],[62.8333334,12.8333333],[62.8333334,1.25],[62.5520834,-5.8333334]],"sourceHandles":["286AC","286B1","286B4","286B5","288BF","288C0","288C5","288C6","288C7","288C8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":249,"id":"upper-exterior-2-east-column-349","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":348,"columnIndex":47,"outlineFt":[[60.78125,-5.8333334],[60.5,1.25],[60.5,12.8333333],[60.2916667,12.8333333],[60.2916667,22.1666666],[60.2916667,37.5],[60.2916667,46.8333333],[59.7083334,46.8333333],[59.7083334,37.5],[59.7083334,22.1666666],[59.7083334,12.8333333],[59.5,12.8333333],[59.5,1.25],[59.21875,-5.8333334]],"sourceHandles":["286B2","286B7","286BA","286BB","288BB","288BC","288C3","288C4","288DB","288DC","288E2","288E3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":248,"id":"upper-exterior-2-east-column-348","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":347,"columnIndex":46,"outlineFt":[[57.4479167,-5.8333334],[57.1666667,1.25],[57.1666667,12.8333333],[57.1666667,22.1666666],[57.3541667,22.1666666],[57.3541667,37.5],[57.1666667,37.5],[57.1666667,46.8333333],[56.1666667,46.8333333],[56.1666667,37.5],[55.9791667,37.5],[55.9791667,22.1666666],[56.1666667,22.1666666],[56.1666667,12.8333333],[56.1666667,1.25],[55.8854167,-5.8333334]],"sourceHandles":["286B8","286BD","286C0","286C1","288EF","288F0","288F5","288F6","288F7","288F8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":247,"id":"upper-exterior-2-east-column-347","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":346,"columnIndex":45,"outlineFt":[[54.1145834,-5.8333334],[53.8333334,1.25],[53.8333334,12.8333333],[53.625,12.8333333],[53.625,22.1666666],[53.625,37.5],[53.625,46.8333333],[53.0416667,46.8333333],[53.0416667,37.5],[53.0416667,22.1666666],[53.0416667,12.8333333],[52.8333334,12.8333333],[52.8333334,1.25],[52.5520834,-5.8333334]],"sourceHandles":["286BE","286C3","286C6","286C7","288EB","288EC","288F3","288F4","2890B","2890C","28912","28913"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":246,"id":"upper-exterior-2-east-column-346","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":345,"columnIndex":44,"outlineFt":[[50.78125,-5.8333334],[50.5,1.25],[50.5,12.8333333],[50.5,22.1666666],[50.6875,22.1666666],[50.6875,37.5],[50.5,37.5],[50.5,46.8333333],[49.5,46.8333333],[49.5,37.5],[49.3125,37.5],[49.3125,22.1666666],[49.5,22.1666666],[49.5,12.8333333],[49.5,1.25],[49.21875,-5.8333334]],"sourceHandles":["286C4","286C9","286CC","286CD","2891F","28920","28925","28926","28927","28928"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":245,"id":"upper-exterior-2-east-column-345","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":344,"columnIndex":43,"outlineFt":[[47.4479167,-5.8333334],[47.1666667,1.25],[47.1666667,12.8333333],[46.9583334,12.8333333],[46.9583334,22.1666666],[46.9583334,37.5],[46.9583334,46.8333333],[46.375,46.8333333],[46.375,37.5],[46.375,22.1666666],[46.375,12.8333333],[46.1666667,12.8333333],[46.1666667,1.25],[45.8854167,-5.8333334]],"sourceHandles":["286CA","286CF","286D2","286D3","2891B","2891C","28923","28924","2893B","2893C","28942","28943"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":244,"id":"upper-exterior-2-east-column-344","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":343,"columnIndex":42,"outlineFt":[[44.1145834,-5.8333334],[43.8333334,1.25],[43.8333334,12.8333333],[43.8333334,22.1666666],[44.0208334,22.1666666],[44.0208334,37.5],[43.8333334,37.5],[43.8333334,46.8333333],[42.8333334,46.8333333],[42.8333334,37.5],[42.6458334,37.5],[42.6458334,22.1666666],[42.8333334,22.1666666],[42.8333334,12.8333333],[42.8333334,1.25],[42.5520834,-5.8333334]],"sourceHandles":["286D0","286D5","286D8","286D9","2894F","28950","28955","28956","28957","28958"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":243,"id":"upper-exterior-2-east-column-343","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":342,"columnIndex":41,"outlineFt":[[40.78125,-5.8333334],[40.5,1.25],[40.5,12.8333333],[40.2916667,12.8333333],[40.2916667,22.1666666],[40.2916667,37.5],[40.2916667,46.8333333],[39.7083334,46.8333333],[39.7083334,37.5],[39.7083334,22.1666666],[39.7083334,12.8333333],[39.5,12.8333333],[39.5,1.25],[39.21875,-5.8333334]],"sourceHandles":["286D6","286DB","286DE","286DF","2894B","2894C","28953","28954","2896B","2896C","28972","28973"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":242,"id":"upper-exterior-2-east-column-342","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":341,"columnIndex":40,"outlineFt":[[37.4479167,-5.8333334],[37.1666667,1.25],[37.1666667,12.8333333],[37.1666667,22.1666666],[37.3541667,22.1666666],[37.3541667,37.5],[37.1666667,37.5],[37.1666667,46.8333333],[36.1666667,46.8333333],[36.1666667,37.5],[35.9791667,37.5],[35.9791667,22.1666666],[36.1666667,22.1666666],[36.1666667,12.8333333],[36.1666667,1.25],[35.8854167,-5.8333334]],"sourceHandles":["286DC","286E1","286E4","286E5","2897F","28980","28985","28986","28987","28988"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":241,"id":"upper-exterior-2-east-column-341","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":340,"columnIndex":39,"outlineFt":[[34.1145834,-5.8333334],[33.8333334,1.25],[33.8333334,12.8333333],[33.625,12.8333333],[33.625,22.1666666],[33.625,37.5],[33.625,46.8333333],[33.0416667,46.8333333],[33.0416667,37.5],[33.0416667,22.1666666],[33.0416667,12.8333333],[32.8333334,12.8333333],[32.8333334,1.25],[32.5520834,-5.8333334]],"sourceHandles":["286E2","286E7","286EA","286EB","2897B","2897C","28983","28984","2899B","2899C","289A2","289A3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":240,"id":"upper-exterior-2-east-column-340","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":339,"columnIndex":38,"outlineFt":[[30.78125,-5.8333334],[30.5,1.25],[30.5,12.8333333],[30.5,22.1666666],[30.6875,22.1666666],[30.6875,37.5],[30.5,37.5],[30.5,46.8333333],[29.5,46.8333333],[29.5,37.5],[29.3125,37.5],[29.3125,22.1666666],[29.5,22.1666666],[29.5,12.8333333],[29.5,1.25],[29.21875,-5.8333334]],"sourceHandles":["286E8","286ED","286F0","286F1","289AF","289B0","289B5","289B6","289B7","289B8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":239,"id":"upper-exterior-2-east-column-339","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":338,"columnIndex":37,"outlineFt":[[27.4479167,-5.8333334],[27.1666667,1.25],[27.1666667,12.8333333],[26.9583334,12.8333333],[26.9583334,22.1666666],[26.9583334,37.5],[26.9583334,46.8333333],[26.375,46.8333333],[26.375,37.5],[26.375,22.1666666],[26.375,12.8333333],[26.1666667,12.8333333],[26.1666667,1.25],[25.8854167,-5.8333334]],"sourceHandles":["286EE","286F3","286F6","286F7","289AB","289AC","289B3","289B4","289CB","289CC","289D2","289D3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":238,"id":"upper-exterior-2-east-column-338","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":337,"columnIndex":36,"outlineFt":[[24.1145834,-5.8333334],[23.8333334,1.25],[23.8333334,12.8333333],[23.8333334,22.1666666],[24.0208334,22.1666666],[24.0208334,37.5],[23.8333334,37.5],[23.8333334,46.8333333],[22.8333334,46.8333333],[22.8333334,37.5],[22.6458334,37.5],[22.6458334,22.1666666],[22.8333334,22.1666666],[22.8333334,12.8333333],[22.8333334,1.25],[22.5520834,-5.8333334]],"sourceHandles":["286F4","286F9","286FC","286FD","289DF","289E0","289E5","289E6","289E7","289E8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":237,"id":"upper-exterior-2-east-column-337","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":336,"columnIndex":35,"outlineFt":[[20.78125,-5.8333334],[20.5,1.25],[20.5,12.8333333],[20.2916667,12.8333333],[20.2916667,22.1666666],[20.2916667,37.5],[20.2916667,46.8333333],[19.7083334,46.8333333],[19.7083334,37.5],[19.7083334,22.1666666],[19.7083334,12.8333333],[19.5,12.8333333],[19.5,1.25],[19.21875,-5.8333334]],"sourceHandles":["286FA","286FF","28702","28703","289DB","289DC","289E3","289E4","289FB","289FC","28A02","28A03"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":236,"id":"upper-exterior-2-east-column-336","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":335,"columnIndex":34,"outlineFt":[[17.4479167,-5.8333334],[17.1666667,1.25],[17.1666667,12.8333333],[17.1666667,22.1666666],[17.3541667,22.1666666],[17.3541667,37.5],[17.1666667,37.5],[17.1666667,46.8333333],[16.1666667,46.8333333],[16.1666667,37.5],[15.9791667,37.5],[15.9791667,22.1666666],[16.1666667,22.1666666],[16.1666667,12.8333333],[16.1666667,1.25],[15.8854167,-5.8333334]],"sourceHandles":["28700","28705","28708","28709","28A0F","28A10","28A15","28A16","28A17","28A18"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":235,"id":"upper-exterior-2-east-column-335","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":334,"columnIndex":33,"outlineFt":[[14.1145834,-5.8333334],[13.8333334,1.25],[13.8333334,12.8333333],[13.625,12.8333333],[13.625,22.1666666],[13.625,37.5],[13.625,46.8333333],[13.0416667,46.8333333],[13.0416667,37.5],[13.0416667,22.1666666],[13.0416667,12.8333333],[12.8333334,12.8333333],[12.8333334,1.25],[12.5520834,-5.8333334]],"sourceHandles":["28706","2870B","2870E","2870F","28A0B","28A0C","28A13","28A14","28A2B","28A2C","28A32","28A33"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":234,"id":"upper-exterior-2-east-column-334","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":333,"columnIndex":32,"outlineFt":[[10.78125,-5.8333334],[10.5,1.25],[10.5,12.8333333],[10.5,22.1666666],[10.6875,22.1666666],[10.6875,37.5],[10.5,37.5],[10.5,46.8333333],[9.5,46.8333333],[9.5,37.5],[9.3125,37.5],[9.3125,22.1666666],[9.5,22.1666666],[9.5,12.8333333],[9.5,1.25],[9.21875,-5.8333334]],"sourceHandles":["2870C","28711","28714","28715","28A3F","28A40","28A45","28A46","28A47","28A48"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":233,"id":"upper-exterior-2-east-column-333","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":332,"columnIndex":31,"outlineFt":[[7.4479167,-5.8333334],[7.1666667,1.25],[7.1666667,12.8333333],[6.9583334,12.8333333],[6.9583334,22.1666666],[6.9583334,37.5],[6.9583334,46.8333333],[6.375,46.8333333],[6.375,37.5],[6.375,22.1666666],[6.375,12.8333333],[6.1666667,12.8333333],[6.1666667,1.25],[5.8854167,-5.8333334]],"sourceHandles":["28712","28717","2871A","2871B","28A3B","28A3C","28A43","28A44","28A5B","28A5C","28A62","28A63"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":232,"id":"upper-exterior-2-east-column-332","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":331,"columnIndex":30,"outlineFt":[[4.1145834,-5.8333334],[3.8333334,1.25],[3.8333334,12.8333333],[3.8333334,22.1666666],[4.0208334,22.1666666],[4.0208334,37.5],[3.8333334,37.5],[3.8333334,46.8333333],[2.8333334,46.8333333],[2.8333334,37.5],[2.6458334,37.5],[2.6458334,22.1666666],[2.8333334,22.1666666],[2.8333334,12.8333333],[2.8333334,1.25],[2.5520834,-5.8333334]],"sourceHandles":["28718","2871D","28720","28721","28A6F","28A70","28A75","28A76","28A77","28A78"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":231,"id":"upper-exterior-2-east-column-331","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":330,"columnIndex":29,"outlineFt":[[0.78125,-5.8333334],[0.5,1.25],[0.5,12.8333333],[0.2916667,12.8333333],[0.2916667,22.1666666],[0.2916667,37.5],[0.2916667,46.8333333],[-0.2916666,46.8333333],[-0.2916666,37.5],[-0.2916666,22.1666666],[-0.2916666,12.8333333],[-0.5,12.8333333],[-0.5,1.25],[-0.78125,-5.8333334]],"sourceHandles":["2871E","28723","28726","28727","28A6B","28A6C","28A73","28A74","28A8B","28A8C","28A92","28A93"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":230,"id":"upper-exterior-2-east-column-330","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":329,"columnIndex":28,"outlineFt":[[-2.5520833,-5.8333334],[-2.8333333,1.25],[-2.8333333,12.8333333],[-2.8333333,22.1666666],[-2.6458333,22.1666666],[-2.6458333,37.5],[-2.8333333,37.5],[-2.8333333,46.8333333],[-3.8333333,46.8333333],[-3.8333333,37.5],[-4.0208333,37.5],[-4.0208333,22.1666666],[-3.8333333,22.1666666],[-3.8333333,12.8333333],[-3.8333333,1.25],[-4.1145833,-5.8333334]],"sourceHandles":["28724","28729","2872C","2872D","28A9F","28AA0","28AA5","28AA6","28AA7","28AA8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":229,"id":"upper-exterior-2-east-column-329","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":328,"columnIndex":27,"outlineFt":[[-5.8854166,-5.8333334],[-6.1666666,1.25],[-6.1666666,12.8333333],[-6.375,12.8333333],[-6.375,22.1666666],[-6.375,37.5],[-6.375,46.8333333],[-6.9583333,46.8333333],[-6.9583333,37.5],[-6.9583333,22.1666666],[-6.9583333,12.8333333],[-7.1666666,12.8333333],[-7.1666666,1.25],[-7.4479166,-5.8333334]],"sourceHandles":["2872A","2872F","28732","28733","28A9B","28A9C","28AA3","28AA4","28ABB","28ABC","28AC2","28AC3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":228,"id":"upper-exterior-2-east-column-328","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":327,"columnIndex":26,"outlineFt":[[-9.21875,-5.8333334],[-9.5,1.25],[-9.5,12.8333333],[-9.5,22.1666666],[-9.3125,22.1666666],[-9.3125,37.5],[-9.5,37.5],[-9.5,46.8333333],[-10.5,46.8333333],[-10.5,37.5],[-10.6875,37.5],[-10.6875,22.1666666],[-10.5,22.1666666],[-10.5,12.8333333],[-10.5,1.25],[-10.78125,-5.8333334]],"sourceHandles":["28730","28735","28738","28739","28ACF","28AD0","28AD5","28AD6","28AD7","28AD8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":227,"id":"upper-exterior-2-east-column-327","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":326,"columnIndex":25,"outlineFt":[[-12.5520833,-5.8333334],[-12.8333333,1.25],[-12.8333333,12.8333333],[-13.0416666,12.8333333],[-13.0416666,22.1666666],[-13.0416666,37.5],[-13.0416666,46.8333333],[-13.625,46.8333333],[-13.625,37.5],[-13.625,22.1666666],[-13.625,12.8333333],[-13.8333333,12.8333333],[-13.8333333,1.25],[-14.1145833,-5.8333334]],"sourceHandles":["28736","2873B","2873E","2873F","28ACB","28ACC","28AD3","28AD4","28AEB","28AEC","28AF2","28AF3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":226,"id":"upper-exterior-2-east-column-326","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":325,"columnIndex":24,"outlineFt":[[-15.8854166,-5.8333334],[-16.1666666,1.25],[-16.1666666,12.8333333],[-16.1666666,22.1666666],[-15.9791666,22.1666666],[-15.9791666,37.5],[-16.1666666,37.5],[-16.1666666,46.8333333],[-17.1666666,46.8333333],[-17.1666666,37.5],[-17.3541666,37.5],[-17.3541666,22.1666666],[-17.1666666,22.1666666],[-17.1666666,12.8333333],[-17.1666666,1.25],[-17.4479166,-5.8333334]],"sourceHandles":["2873C","28741","28744","28745","28AFF","28B00","28B05","28B06","28B07","28B08"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":225,"id":"upper-exterior-2-east-column-325","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":324,"columnIndex":23,"outlineFt":[[-19.21875,-5.8333334],[-19.5,1.25],[-19.5,12.8333333],[-19.7083333,12.8333333],[-19.7083333,22.1666666],[-19.7083333,37.5],[-19.7083333,46.8333333],[-20.2916666,46.8333333],[-20.2916666,37.5],[-20.2916666,22.1666666],[-20.2916666,12.8333333],[-20.5,12.8333333],[-20.5,1.25],[-20.78125,-5.8333334]],"sourceHandles":["28742","28747","2874A","2874B","28AFB","28AFC","28B03","28B04","28B1B","28B1C","28B22","28B23"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":224,"id":"upper-exterior-2-east-column-324","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":323,"columnIndex":22,"outlineFt":[[-22.5520833,-5.8333334],[-22.8333333,1.25],[-22.8333333,12.8333333],[-22.8333333,22.1666666],[-22.6458333,22.1666666],[-22.6458333,37.5],[-22.8333333,37.5],[-22.8333333,46.8333333],[-23.8333333,46.8333333],[-23.8333333,37.5],[-24.0208333,37.5],[-24.0208333,22.1666666],[-23.8333333,22.1666666],[-23.8333333,12.8333333],[-23.8333333,1.25],[-24.1145833,-5.8333334]],"sourceHandles":["28748","2874D","28750","28751","28B2F","28B30","28B35","28B36","28B37","28B38"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":223,"id":"upper-exterior-2-east-column-323","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":322,"columnIndex":21,"outlineFt":[[-25.8854166,-5.8333334],[-26.1666666,1.25],[-26.1666666,12.8333333],[-26.375,12.8333333],[-26.375,22.1666666],[-26.375,37.5],[-26.375,46.8333333],[-26.9583333,46.8333333],[-26.9583333,37.5],[-26.9583333,22.1666666],[-26.9583333,12.8333333],[-27.1666666,12.8333333],[-27.1666666,1.25],[-27.4479166,-5.8333334]],"sourceHandles":["2874E","28753","28756","28757","28B2B","28B2C","28B33","28B34","28B4B","28B4C","28B52","28B53"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":222,"id":"upper-exterior-2-east-column-322","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":321,"columnIndex":20,"outlineFt":[[-29.21875,-5.8333334],[-29.5,1.25],[-29.5,12.8333333],[-29.5,22.1666666],[-29.3125,22.1666666],[-29.3125,37.5],[-29.5,37.5],[-29.5,46.8333333],[-30.5,46.8333333],[-30.5,37.5],[-30.6875,37.5],[-30.6875,22.1666666],[-30.5,22.1666666],[-30.5,12.8333333],[-30.5,1.25],[-30.78125,-5.8333334]],"sourceHandles":["28754","28759","2875C","2875D","28B5F","28B60","28B65","28B66","28B67","28B68"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":221,"id":"upper-exterior-2-east-column-321","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":320,"columnIndex":19,"outlineFt":[[-32.5520833,-5.8333334],[-32.8333333,1.25],[-32.8333333,12.8333333],[-33.0416666,12.8333333],[-33.0416666,22.1666666],[-33.0416666,37.5],[-33.0416666,46.8333333],[-33.625,46.8333333],[-33.625,37.5],[-33.625,22.1666666],[-33.625,12.8333333],[-33.8333333,12.8333333],[-33.8333333,1.25],[-34.1145833,-5.8333334]],"sourceHandles":["2875A","2875F","28762","28763","28B5B","28B5C","28B63","28B64","28B7B","28B7C","28B82","28B83"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":220,"id":"upper-exterior-2-east-column-320","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":319,"columnIndex":18,"outlineFt":[[-35.8854166,-5.8333334],[-36.1666666,1.25],[-36.1666666,12.8333333],[-36.1666666,22.1666666],[-35.9791666,22.1666666],[-35.9791666,37.5],[-36.1666666,37.5],[-36.1666666,46.8333333],[-37.1666666,46.8333333],[-37.1666666,37.5],[-37.3541666,37.5],[-37.3541666,22.1666666],[-37.1666666,22.1666666],[-37.1666666,12.8333333],[-37.1666666,1.25],[-37.4479166,-5.8333334]],"sourceHandles":["28760","28765","28768","28769","28B8F","28B90","28B95","28B96","28B97","28B98"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":219,"id":"upper-exterior-2-east-column-319","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":318,"columnIndex":17,"outlineFt":[[-39.21875,-5.8333334],[-39.5,1.25],[-39.5,12.8333333],[-39.7083333,12.8333333],[-39.7083333,22.1666666],[-39.7083333,37.5],[-39.7083333,46.8333333],[-40.2916666,46.8333333],[-40.2916666,37.5],[-40.2916666,22.1666666],[-40.2916666,12.8333333],[-40.5,12.8333333],[-40.5,1.25],[-40.78125,-5.8333334]],"sourceHandles":["28766","2876B","2876E","2876F","28B8B","28B8C","28B93","28B94","28BAB","28BAC","28BB2","28BB3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":218,"id":"upper-exterior-2-east-column-318","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":317,"columnIndex":16,"outlineFt":[[-42.5520833,-5.8333334],[-42.8333333,1.25],[-42.8333333,12.8333333],[-42.8333333,22.1666666],[-42.6458333,22.1666666],[-42.6458333,37.5],[-42.8333333,37.5],[-42.8333333,46.8333333],[-43.8333333,46.8333333],[-43.8333333,37.5],[-44.0208333,37.5],[-44.0208333,22.1666666],[-43.8333333,22.1666666],[-43.8333333,12.8333333],[-43.8333333,1.25],[-44.1145833,-5.8333334]],"sourceHandles":["2876C","28771","28774","28775","28BBF","28BC0","28BC5","28BC6","28BC7","28BC8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":217,"id":"upper-exterior-2-east-column-317","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":316,"columnIndex":15,"outlineFt":[[-45.8854166,-5.8333334],[-46.1666666,1.25],[-46.1666666,12.8333333],[-46.375,12.8333333],[-46.375,22.1666666],[-46.375,37.5],[-46.375,46.8333333],[-46.9583333,46.8333333],[-46.9583333,37.5],[-46.9583333,22.1666666],[-46.9583333,12.8333333],[-47.1666666,12.8333333],[-47.1666666,1.25],[-47.4479166,-5.8333334]],"sourceHandles":["28772","28777","2877A","2877B","28BBB","28BBC","28BC3","28BC4","28BDB","28BDC","28BE2","28BE3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":216,"id":"upper-exterior-2-east-column-316","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":315,"columnIndex":14,"outlineFt":[[-49.21875,-5.8333334],[-49.5,1.25],[-49.5,12.8333333],[-49.5,22.1666666],[-49.3125,22.1666666],[-49.3125,37.5],[-49.5,37.5],[-49.5,46.8333333],[-50.5,46.8333333],[-50.5,37.5],[-50.6875,37.5],[-50.6875,22.1666666],[-50.5,22.1666666],[-50.5,12.8333333],[-50.5,1.25],[-50.78125,-5.8333334]],"sourceHandles":["28778","2877D","28780","28781","28BEF","28BF0","28BF5","28BF6","28BF7","28BF8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":215,"id":"upper-exterior-2-east-column-315","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":314,"columnIndex":13,"outlineFt":[[-52.5520833,-5.8333334],[-52.8333333,1.25],[-52.8333333,12.8333333],[-53.0416666,12.8333333],[-53.0416666,22.1666666],[-53.0416666,37.5],[-53.0416666,46.8333333],[-53.625,46.8333333],[-53.625,37.5],[-53.625,22.1666666],[-53.625,12.8333333],[-53.8333333,12.8333333],[-53.8333333,1.25],[-54.1145833,-5.8333334]],"sourceHandles":["2877E","28783","28786","28787","28BEB","28BEC","28BF3","28BF4","28C0B","28C0C","28C12","28C13"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":214,"id":"upper-exterior-2-east-column-314","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":313,"columnIndex":12,"outlineFt":[[-55.8854166,-5.8333334],[-56.1666666,1.25],[-56.1666666,12.8333333],[-56.1666666,22.1666666],[-55.9791666,22.1666666],[-55.9791666,37.5],[-56.1666666,37.5],[-56.1666666,46.8333333],[-57.1666666,46.8333333],[-57.1666666,37.5],[-57.3541666,37.5],[-57.3541666,22.1666666],[-57.1666666,22.1666666],[-57.1666666,12.8333333],[-57.1666666,1.25],[-57.4479166,-5.8333334]],"sourceHandles":["28784","28789","2878C","2878D","28C1F","28C20","28C25","28C26","28C27","28C28"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":213,"id":"upper-exterior-2-east-column-313","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":312,"columnIndex":11,"outlineFt":[[-59.21875,-5.8333334],[-59.5,1.25],[-59.5,12.8333333],[-59.7083333,12.8333333],[-59.7083333,22.1666666],[-59.7083333,37.5],[-59.7083333,46.8333333],[-60.2916666,46.8333333],[-60.2916666,37.5],[-60.2916666,22.1666666],[-60.2916666,12.8333333],[-60.5,12.8333333],[-60.5,1.25],[-60.78125,-5.8333334]],"sourceHandles":["2878A","2878F","28792","28793","28C1B","28C1C","28C23","28C24","28C3B","28C3C","28C42","28C43"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":212,"id":"upper-exterior-2-east-column-312","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":311,"columnIndex":10,"outlineFt":[[-62.5520833,-5.8333334],[-62.8333333,1.25],[-62.8333333,12.8333333],[-62.8333333,22.1666666],[-62.6458333,22.1666666],[-62.6458333,37.5],[-62.8333333,37.5],[-62.8333333,46.8333333],[-63.8333333,46.8333333],[-63.8333333,37.5],[-64.0208333,37.5],[-64.0208333,22.1666666],[-63.8333333,22.1666666],[-63.8333333,12.8333333],[-63.8333333,1.25],[-64.1145833,-5.8333334]],"sourceHandles":["28790","28795","28798","28799","28C4F","28C50","28C55","28C56","28C57","28C58"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":211,"id":"upper-exterior-2-east-column-311","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":310,"columnIndex":9,"outlineFt":[[-65.8854166,-5.8333334],[-66.1666666,1.25],[-66.1666666,12.8333333],[-66.375,12.8333333],[-66.375,22.1666666],[-66.375,37.5],[-66.375,46.8333333],[-66.9583333,46.8333333],[-66.9583333,37.5],[-66.9583333,22.1666666],[-66.9583333,12.8333333],[-67.1666666,12.8333333],[-67.1666666,1.25],[-67.4479166,-5.8333334]],"sourceHandles":["28796","2879B","2879E","2879F","28C4B","28C4C","28C53","28C54","28C6B","28C6C","28C72","28C73"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":210,"id":"upper-exterior-2-east-column-310","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":309,"columnIndex":8,"outlineFt":[[-69.21875,-5.8333334],[-69.5,1.25],[-69.5,12.8333333],[-69.5,22.1666666],[-69.3125,22.1666666],[-69.3125,37.5],[-69.5,37.5],[-69.5,46.8333333],[-70.5,46.8333333],[-70.5,37.5],[-70.6875,37.5],[-70.6875,22.1666666],[-70.5,22.1666666],[-70.5,12.8333333],[-70.5,1.25],[-70.78125,-5.8333334]],"sourceHandles":["2879C","287A1","287A4","287A5","28C7F","28C80","28C85","28C86","28C87","28C88"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":209,"id":"upper-exterior-2-east-column-309","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":308,"columnIndex":7,"outlineFt":[[-72.5520833,-5.8333334],[-72.8333333,1.25],[-72.8333333,12.8333333],[-73.0416666,12.8333333],[-73.0416666,22.1666666],[-73.0416666,37.5],[-73.0416666,46.8333333],[-73.625,46.8333333],[-73.625,37.5],[-73.625,22.1666666],[-73.625,12.8333333],[-73.8333333,12.8333333],[-73.8333333,1.25],[-74.1145833,-5.8333334]],"sourceHandles":["287A2","287A7","287AA","287AB","28C7B","28C7C","28C83","28C84","28C9B","28C9C","28CA2","28CA3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":208,"id":"upper-exterior-2-east-column-308","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":307,"columnIndex":6,"outlineFt":[[-75.8854166,-5.8333334],[-76.1666666,1.25],[-76.1666666,12.8333333],[-76.1666666,22.1666666],[-75.9791666,22.1666666],[-75.9791666,37.5],[-76.1666666,37.5],[-76.1666666,46.8333333],[-77.1666666,46.8333333],[-77.1666666,37.5],[-77.3541666,37.5],[-77.3541666,22.1666666],[-77.1666666,22.1666666],[-77.1666666,12.8333333],[-77.1666666,1.25],[-77.4479166,-5.8333334]],"sourceHandles":["287A8","287AD","287B0","287B1","28CAF","28CB0","28CB5","28CB6","28CB7","28CB8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":207,"id":"upper-exterior-2-east-column-307","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":306,"columnIndex":5,"outlineFt":[[-79.21875,-5.8333334],[-79.5,1.25],[-79.5,12.8333333],[-79.7083333,12.8333333],[-79.7083333,22.1666666],[-79.7083333,37.5],[-79.7083333,46.8333333],[-80.2916666,46.8333333],[-80.2916666,37.5],[-80.2916666,22.1666666],[-80.2916666,12.8333333],[-80.5,12.8333333],[-80.5,1.25],[-80.78125,-5.8333334]],"sourceHandles":["287AE","287B3","287B6","287B7","28CAB","28CAC","28CB3","28CB4","28CCB","28CCC","28CD2","28CD3"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":206,"id":"upper-exterior-2-east-column-306","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":305,"columnIndex":4,"outlineFt":[[-82.5520833,-5.8333334],[-82.8333333,1.25],[-82.8333333,12.8333333],[-82.8333333,22.1666666],[-82.6458333,22.1666666],[-82.6458333,37.5],[-82.8333333,37.5],[-82.8333333,46.8333333],[-83.8333333,46.8333333],[-83.8333333,37.5],[-84.0208333,37.5],[-84.0208333,22.1666666],[-83.8333333,22.1666666],[-83.8333333,12.8333333],[-83.8333333,1.25],[-84.1145833,-5.8333334]],"sourceHandles":["287B4","287B9","287BC","287BD","28CDF","28CE0","28CE5","28CE6","28CE7","28CE8"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":205,"id":"upper-exterior-2-east-column-305","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":304,"columnIndex":3,"outlineFt":[[-85.8854166,-5.8333334],[-86.1666666,1.25],[-86.1666666,12.8333333],[-86.375,12.8333333],[-86.375,22.1666666],[-86.375,37.5],[-86.375,46.8333333],[-86.9583333,46.8333333],[-86.9583333,37.5],[-86.9583333,22.1666666],[-86.9583333,12.8333333],[-87.1666666,12.8333333],[-87.1666666,1.25],[-87.4479166,-5.8333334]],"sourceHandles":["287BA","287BF","287C2","287C3","28CDB","28CDC","28CE3","28CE4","28CFB","28CFC","28D02","28D03"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":204,"id":"upper-exterior-2-east-column-304","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":303,"columnIndex":2,"outlineFt":[[-89.21875,-5.8333334],[-89.5,1.25],[-89.5,12.8333333],[-89.5,22.1666666],[-89.3125,22.1666666],[-89.3125,37.5],[-89.5,37.5],[-89.5,46.8333333],[-90.5,46.8333333],[-90.5,37.5],[-90.6875,37.5],[-90.6875,22.1666666],[-90.5,22.1666666],[-90.5,12.8333333],[-90.5,1.25],[-90.78125,-5.8333334]],"sourceHandles":["287C0","287C5","287C8","287C9","28D0F","28D10","28D15","28D16","28D17","28D18"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":203,"id":"upper-exterior-2-east-column-303","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":302,"columnIndex":1,"outlineFt":[[-92.5520833,-5.8333334],[-92.8333333,1.25],[-92.8333333,12.8333333],[-93.0416666,12.8333333],[-93.0416666,22.1666666],[-93.0416666,37.5],[-93.0416666,46.8333333],[-93.625,46.8333333],[-93.625,37.5],[-93.625,22.1666666],[-93.625,12.8333333],[-93.8333333,12.8333333],[-93.8333333,1.25],[-94.1145833,-5.8333334]],"sourceHandles":["287C6","287CB","287CD","287CE","28D0B","28D0C","28D13","28D14","28D2B","28D2C","28D32","28D33"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":202,"id":"upper-exterior-2-east-column-302","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":301,"columnIndex":0,"outlineFt":[[-95.8854166,-5.8333334],[-96.1170343,-0.0],[-96.1666666,1.25],[-96.1668614,1.25],[-96.1668614,17.5],[-96.1668614,17.5049035],[-96.1668614,22.1666666],[-95.9791666,22.1666666],[-95.9791666,37.5],[-96.1668614,37.5],[-96.1668614,49.0833333],[-98.375,49.0833333],[-98.375,37.5],[-98.375,22.1666666],[-98.375,17.5049035],[-98.375,17.5],[-98.375,1.25],[-98.375,-0.0],[-98.375,-5.8333334]],"sourceHandles":["287CF","287D0","287D1","287D3","287D5","287D6","287D7","28D41","28D43"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":201,"id":"upper-exterior-2-east-column-301","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[93.8333334,1.25],[94.1145834,-5.8333334],[95.8854167,-5.8333334],[96.1170343,-0.0],[96.1666667,1.25]],"sourceHandles":["2866A","2866B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-0","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[90.5,1.25],[90.78125,-5.8333334],[92.5520834,-5.8333334],[92.8333334,1.25]],"sourceHandles":["28669","2866F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-1","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[87.1666667,1.25],[87.4479167,-5.8333334],[89.21875,-5.8333334],[89.5,1.25]],"sourceHandles":["28680","28683"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-2","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[83.8333334,1.25],[84.1145834,-5.8333334],[85.8854167,-5.8333334],[86.1666667,1.25]],"sourceHandles":["28686","28689"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-3","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[80.5,1.25],[80.78125,-5.8333334],[82.5520834,-5.8333334],[82.8333334,1.25]],"sourceHandles":["2868C","2868F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-4","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[77.1666667,1.25],[77.4479167,-5.8333334],[79.21875,-5.8333334],[79.5,1.25]],"sourceHandles":["28692","28695"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-5","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[73.8333334,1.25],[74.1145834,-5.8333334],[75.8854167,-5.8333334],[76.1666667,1.25]],"sourceHandles":["28698","2869B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-6","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[70.5,1.25],[70.78125,-5.8333334],[72.5520834,-5.8333334],[72.8333334,1.25]],"sourceHandles":["2869E","286A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-7","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[67.1666667,1.25],[67.4479167,-5.8333334],[69.21875,-5.8333334],[69.5,1.25]],"sourceHandles":["286A4","286A7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-8","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[63.8333334,1.25],[64.1145834,-5.8333334],[65.8854167,-5.8333334],[66.1666667,1.25]],"sourceHandles":["286AA","286AD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-9","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[60.5,1.25],[60.78125,-5.8333334],[62.5520834,-5.8333334],[62.8333334,1.25]],"sourceHandles":["286B0","286B3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-10","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[57.1666667,1.25],[57.4479167,-5.8333334],[59.21875,-5.8333334],[59.5,1.25]],"sourceHandles":["286B6","286B9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-11","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[53.8333334,1.25],[54.1145834,-5.8333334],[55.8854167,-5.8333334],[56.1666667,1.25]],"sourceHandles":["286BC","286BF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-12","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[50.5,1.25],[50.78125,-5.8333334],[52.5520834,-5.8333334],[52.8333334,1.25]],"sourceHandles":["286C2","286C5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-13","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[47.1666667,1.25],[47.4479167,-5.8333334],[49.21875,-5.8333334],[49.5,1.25]],"sourceHandles":["286C8","286CB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-14","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[43.8333334,1.25],[44.1145834,-5.8333334],[45.8854167,-5.8333334],[46.1666667,1.25]],"sourceHandles":["286CE","286D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-15","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[40.5,1.25],[40.78125,-5.8333334],[42.5520834,-5.8333334],[42.8333334,1.25]],"sourceHandles":["286D4","286D7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-16","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[37.1666667,1.25],[37.4479167,-5.8333334],[39.21875,-5.8333334],[39.5,1.25]],"sourceHandles":["286DA","286DD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-17","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[33.8333334,1.25],[34.1145834,-5.8333334],[35.8854167,-5.8333334],[36.1666667,1.25]],"sourceHandles":["286E0","286E3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-18","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[30.5,1.25],[30.78125,-5.8333334],[32.5520834,-5.8333334],[32.8333334,1.25]],"sourceHandles":["286E6","286E9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-19","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[27.1666667,1.25],[27.4479167,-5.8333334],[29.21875,-5.8333334],[29.5,1.25]],"sourceHandles":["286EC","286EF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-20","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[23.8333334,1.25],[24.1145834,-5.8333334],[25.8854167,-5.8333334],[26.1666667,1.25]],"sourceHandles":["286F2","286F5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-21","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[20.5,1.25],[20.78125,-5.8333334],[22.5520834,-5.8333334],[22.8333334,1.25]],"sourceHandles":["286F8","286FB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-22","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[17.1666667,1.25],[17.4479167,-5.8333334],[19.21875,-5.8333334],[19.5,1.25]],"sourceHandles":["286FE","28701"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-23","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[13.8333334,1.25],[14.1145834,-5.8333334],[15.8854167,-5.8333334],[16.1666667,1.25]],"sourceHandles":["28704","28707"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-24","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[10.5,1.25],[10.78125,-5.8333334],[12.5520834,-5.8333334],[12.8333334,1.25]],"sourceHandles":["2870A","2870D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-25","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[7.1666667,1.25],[7.4479167,-5.8333334],[9.21875,-5.8333334],[9.5,1.25]],"sourceHandles":["28710","28713"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-26","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[3.8333334,1.25],[4.1145834,-5.8333334],[5.8854167,-5.8333334],[6.1666667,1.25]],"sourceHandles":["28716","28719"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-27","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[0.5,1.25],[0.78125,-5.8333334],[2.5520834,-5.8333334],[2.8333334,1.25]],"sourceHandles":["2871C","2871F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-28","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[-2.8333333,1.25],[-2.5520833,-5.8333334],[-0.78125,-5.8333334],[-0.5,1.25]],"sourceHandles":["28722","28725"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-29","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[-6.1666666,1.25],[-5.8854166,-5.8333334],[-4.1145833,-5.8333334],[-3.8333333,1.25]],"sourceHandles":["28728","2872B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-30","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[-9.5,1.25],[-9.21875,-5.8333334],[-7.4479166,-5.8333334],[-7.1666666,1.25]],"sourceHandles":["2872E","28731"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-31","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[-12.8333333,1.25],[-12.5520833,-5.8333334],[-10.78125,-5.8333334],[-10.5,1.25]],"sourceHandles":["28734","28737"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-32","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[-16.1666666,1.25],[-15.8854166,-5.8333334],[-14.1145833,-5.8333334],[-13.8333333,1.25]],"sourceHandles":["2873A","2873D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-33","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[-19.5,1.25],[-19.21875,-5.8333334],[-17.4479166,-5.8333334],[-17.1666666,1.25]],"sourceHandles":["28740","28743"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-34","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[-22.8333333,1.25],[-22.5520833,-5.8333334],[-20.78125,-5.8333334],[-20.5,1.25]],"sourceHandles":["28746","28749"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-35","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[-26.1666666,1.25],[-25.8854166,-5.8333334],[-24.1145833,-5.8333334],[-23.8333333,1.25]],"sourceHandles":["2874C","2874F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-36","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[-29.5,1.25],[-29.21875,-5.8333334],[-27.4479166,-5.8333334],[-27.1666666,1.25]],"sourceHandles":["28752","28755"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-37","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[-32.8333333,1.25],[-32.5520833,-5.8333334],[-30.78125,-5.8333334],[-30.5,1.25]],"sourceHandles":["28758","2875B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-38","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[-36.1666666,1.25],[-35.8854166,-5.8333334],[-34.1145833,-5.8333334],[-33.8333333,1.25]],"sourceHandles":["2875E","28761"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-39","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[-39.5,1.25],[-39.21875,-5.8333334],[-37.4479166,-5.8333334],[-37.1666666,1.25]],"sourceHandles":["28764","28767"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-40","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[-42.8333333,1.25],[-42.5520833,-5.8333334],[-40.78125,-5.8333334],[-40.5,1.25]],"sourceHandles":["2876A","2876D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-41","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[-46.1666666,1.25],[-45.8854166,-5.8333334],[-44.1145833,-5.8333334],[-43.8333333,1.25]],"sourceHandles":["28770","28773"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-42","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[-49.5,1.25],[-49.21875,-5.8333334],[-47.4479166,-5.8333334],[-47.1666666,1.25]],"sourceHandles":["28776","28779"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-43","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[-52.8333333,1.25],[-52.5520833,-5.8333334],[-50.78125,-5.8333334],[-50.5,1.25]],"sourceHandles":["2877C","2877F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-44","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[-56.1666666,1.25],[-55.8854166,-5.8333334],[-54.1145833,-5.8333334],[-53.8333333,1.25]],"sourceHandles":["28782","28785"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-45","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[-59.5,1.25],[-59.21875,-5.8333334],[-57.4479166,-5.8333334],[-57.1666666,1.25]],"sourceHandles":["28788","2878B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-46","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[-62.8333333,1.25],[-62.5520833,-5.8333334],[-60.78125,-5.8333334],[-60.5,1.25]],"sourceHandles":["2878E","28791"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-47","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[-66.1666666,1.25],[-65.8854166,-5.8333334],[-64.1145833,-5.8333334],[-63.8333333,1.25]],"sourceHandles":["28794","28797"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-48","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[-69.5,1.25],[-69.21875,-5.8333334],[-67.4479166,-5.8333334],[-67.1666666,1.25]],"sourceHandles":["2879A","2879D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-49","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[-72.8333333,1.25],[-72.5520833,-5.8333334],[-70.78125,-5.8333334],[-70.5,1.25]],"sourceHandles":["287A0","287A3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-50","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[-76.1666666,1.25],[-75.8854166,-5.8333334],[-74.1145833,-5.8333334],[-73.8333333,1.25]],"sourceHandles":["287A6","287A9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-51","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[-79.5,1.25],[-79.21875,-5.8333334],[-77.4479166,-5.8333334],[-77.1666666,1.25]],"sourceHandles":["287AC","287AF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-52","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[-82.8333333,1.25],[-82.5520833,-5.8333334],[-80.78125,-5.8333334],[-80.5,1.25]],"sourceHandles":["287B2","287B5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-53","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[-86.1666666,1.25],[-85.8854166,-5.8333334],[-84.1145833,-5.8333334],[-83.8333333,1.25]],"sourceHandles":["287B8","287BB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-54","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[-89.5,1.25],[-89.21875,-5.8333334],[-87.4479166,-5.8333334],[-87.1666666,1.25]],"sourceHandles":["287BE","287C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-55","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[-92.8333333,1.25],[-92.5520833,-5.8333334],[-90.78125,-5.8333334],[-90.5,1.25]],"sourceHandles":["287C4","287C7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-56","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[-96.1666666,1.25],[-96.1170343,-0.0],[-95.8854166,-5.8333334],[-94.1145833,-5.8333334],[-93.8333333,1.25]],"sourceHandles":["287CA","287CC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-107-57","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[93.625,18.8333333],[93.625,12.8333333],[93.8333334,12.8333333],[96.1666667,12.8333333],[96.1666667,17.5],[96.1666667,18.8333333]],"sourceHandles":["287E0","287E1","287FE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-0","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[90.5,18.8333333],[90.5,12.8333333],[92.8333334,12.8333333],[93.0416667,12.8333333],[93.0416667,18.8333333]],"sourceHandles":["287FC","287FD","28800"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-1","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[86.9583334,18.8333333],[86.9583334,12.8333333],[87.1666667,12.8333333],[89.5,12.8333333],[89.5,18.8333333]],"sourceHandles":["287FA","287FB","28801"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-2","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[83.8333334,18.8333333],[83.8333334,12.8333333],[86.1666667,12.8333333],[86.375,12.8333333],[86.375,18.8333333]],"sourceHandles":["28841","28842","28843"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-3","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[80.2916667,18.8333333],[80.2916667,12.8333333],[80.5,12.8333333],[82.8333334,12.8333333],[82.8333334,18.8333333]],"sourceHandles":["2883F","28840","28844"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-4","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[77.1666667,18.8333333],[77.1666667,12.8333333],[79.5,12.8333333],[79.7083334,12.8333333],[79.7083334,18.8333333]],"sourceHandles":["28871","28872","28873"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-5","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[73.625,18.8333333],[73.625,12.8333333],[73.8333334,12.8333333],[76.1666667,12.8333333],[76.1666667,18.8333333]],"sourceHandles":["2886F","28870","28874"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-6","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[70.5,18.8333333],[70.5,12.8333333],[72.8333334,12.8333333],[73.0416667,12.8333333],[73.0416667,18.8333333]],"sourceHandles":["288A1","288A2","288A3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-7","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[66.9583334,18.8333333],[66.9583334,12.8333333],[67.1666667,12.8333333],[69.5,12.8333333],[69.5,18.8333333]],"sourceHandles":["2889F","288A0","288A4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-8","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[63.8333334,18.8333333],[63.8333334,12.8333333],[66.1666667,12.8333333],[66.375,12.8333333],[66.375,18.8333333]],"sourceHandles":["288D1","288D2","288D3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-9","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[60.2916667,18.8333333],[60.2916667,12.8333333],[60.5,12.8333333],[62.8333334,12.8333333],[62.8333334,18.8333333]],"sourceHandles":["288CF","288D0","288D4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-10","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[57.1666667,18.8333333],[57.1666667,12.8333333],[59.5,12.8333333],[59.7083334,12.8333333],[59.7083334,18.8333333]],"sourceHandles":["28901","28902","28903"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-11","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[53.625,18.8333333],[53.625,12.8333333],[53.8333334,12.8333333],[56.1666667,12.8333333],[56.1666667,18.8333333]],"sourceHandles":["288FF","28900","28904"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-12","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[50.5,18.8333333],[50.5,12.8333333],[52.8333334,12.8333333],[53.0416667,12.8333333],[53.0416667,18.8333333]],"sourceHandles":["28931","28932","28933"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-13","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[46.9583334,18.8333333],[46.9583334,12.8333333],[47.1666667,12.8333333],[49.5,12.8333333],[49.5,18.8333333]],"sourceHandles":["2892F","28930","28934"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-14","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[43.8333334,18.8333333],[43.8333334,12.8333333],[46.1666667,12.8333333],[46.375,12.8333333],[46.375,18.8333333]],"sourceHandles":["28961","28962","28963"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-15","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[40.2916667,18.8333333],[40.2916667,12.8333333],[40.5,12.8333333],[42.8333334,12.8333333],[42.8333334,18.8333333]],"sourceHandles":["2895F","28960","28964"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-16","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[37.1666667,18.8333333],[37.1666667,12.8333333],[39.5,12.8333333],[39.7083334,12.8333333],[39.7083334,18.8333333]],"sourceHandles":["28991","28992","28993"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-17","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[33.625,18.8333333],[33.625,12.8333333],[33.8333334,12.8333333],[36.1666667,12.8333333],[36.1666667,18.8333333]],"sourceHandles":["2898F","28990","28994"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-18","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[30.5,18.8333333],[30.5,12.8333333],[32.8333334,12.8333333],[33.0416667,12.8333333],[33.0416667,18.8333333]],"sourceHandles":["289C1","289C2","289C3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-19","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[26.9583334,18.8333333],[26.9583334,12.8333333],[27.1666667,12.8333333],[29.5,12.8333333],[29.5,18.8333333]],"sourceHandles":["289BF","289C0","289C4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-20","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[23.8333334,18.8333333],[23.8333334,12.8333333],[26.1666667,12.8333333],[26.375,12.8333333],[26.375,18.8333333]],"sourceHandles":["289F1","289F2","289F3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-21","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[20.2916667,18.8333333],[20.2916667,12.8333333],[20.5,12.8333333],[22.8333334,12.8333333],[22.8333334,18.8333333]],"sourceHandles":["289EF","289F0","289F4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-22","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[17.1666667,18.8333333],[17.1666667,12.8333333],[19.5,12.8333333],[19.7083334,12.8333333],[19.7083334,18.8333333]],"sourceHandles":["28A21","28A22","28A23"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-23","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[13.625,18.8333333],[13.625,12.8333333],[13.8333334,12.8333333],[16.1666667,12.8333333],[16.1666667,18.8333333]],"sourceHandles":["28A1F","28A20","28A24"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-24","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[10.5,18.8333333],[10.5,12.8333333],[12.8333334,12.8333333],[13.0416667,12.8333333],[13.0416667,18.8333333]],"sourceHandles":["28A51","28A52","28A53"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-25","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[6.9583334,18.8333333],[6.9583334,12.8333333],[7.1666667,12.8333333],[9.5,12.8333333],[9.5,18.8333333]],"sourceHandles":["28A4F","28A50","28A54"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-26","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[3.8333334,18.8333333],[3.8333334,12.8333333],[6.1666667,12.8333333],[6.375,12.8333333],[6.375,18.8333333]],"sourceHandles":["28A81","28A82","28A83"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-27","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[0.2916667,18.8333333],[0.2916667,12.8333333],[0.5,12.8333333],[2.8333334,12.8333333],[2.8333334,18.8333333]],"sourceHandles":["28A7F","28A80","28A84"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-28","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[-2.8333333,18.8333333],[-2.8333333,12.8333333],[-0.5,12.8333333],[-0.2916666,12.8333333],[-0.2916666,18.8333333]],"sourceHandles":["28AB1","28AB2","28AB3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-29","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[-6.375,18.8333333],[-6.375,12.8333333],[-6.1666666,12.8333333],[-3.8333333,12.8333333],[-3.8333333,18.8333333]],"sourceHandles":["28AAF","28AB0","28AB4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-30","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[-9.5,18.8333333],[-9.5,12.8333333],[-7.1666666,12.8333333],[-6.9583333,12.8333333],[-6.9583333,18.8333333]],"sourceHandles":["28AE1","28AE2","28AE3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-31","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[-13.0416666,18.8333333],[-13.0416666,12.8333333],[-12.8333333,12.8333333],[-10.5,12.8333333],[-10.5,18.8333333]],"sourceHandles":["28ADF","28AE0","28AE4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-32","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[-16.1666666,18.8333333],[-16.1666666,12.8333333],[-13.8333333,12.8333333],[-13.625,12.8333333],[-13.625,18.8333333]],"sourceHandles":["28B11","28B12","28B13"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-33","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[-19.7083333,18.8333333],[-19.7083333,12.8333333],[-19.5,12.8333333],[-17.1666666,12.8333333],[-17.1666666,18.8333333]],"sourceHandles":["28B0F","28B10","28B14"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-34","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[-22.8333333,18.8333333],[-22.8333333,12.8333333],[-20.5,12.8333333],[-20.2916666,12.8333333],[-20.2916666,18.8333333]],"sourceHandles":["28B41","28B42","28B43"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-35","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[-26.375,18.8333333],[-26.375,12.8333333],[-26.1666666,12.8333333],[-23.8333333,12.8333333],[-23.8333333,18.8333333]],"sourceHandles":["28B3F","28B40","28B44"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-36","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[-29.5,18.8333333],[-29.5,12.8333333],[-27.1666666,12.8333333],[-26.9583333,12.8333333],[-26.9583333,18.8333333]],"sourceHandles":["28B71","28B72","28B73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-37","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[-33.0416666,18.8333333],[-33.0416666,12.8333333],[-32.8333333,12.8333333],[-30.5,12.8333333],[-30.5,18.8333333]],"sourceHandles":["28B6F","28B70","28B74"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-38","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[-36.1666666,18.8333333],[-36.1666666,12.8333333],[-33.8333333,12.8333333],[-33.625,12.8333333],[-33.625,18.8333333]],"sourceHandles":["28BA1","28BA2","28BA3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-39","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[-39.7083333,18.8333333],[-39.7083333,12.8333333],[-39.5,12.8333333],[-37.1666666,12.8333333],[-37.1666666,18.8333333]],"sourceHandles":["28B9F","28BA0","28BA4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-40","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[-42.8333333,18.8333333],[-42.8333333,12.8333333],[-40.5,12.8333333],[-40.2916666,12.8333333],[-40.2916666,18.8333333]],"sourceHandles":["28BD1","28BD2","28BD3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-41","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[-46.375,18.8333333],[-46.375,12.8333333],[-46.1666666,12.8333333],[-43.8333333,12.8333333],[-43.8333333,18.8333333]],"sourceHandles":["28BCF","28BD0","28BD4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-42","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[-49.5,18.8333333],[-49.5,12.8333333],[-47.1666666,12.8333333],[-46.9583333,12.8333333],[-46.9583333,18.8333333]],"sourceHandles":["28C01","28C02","28C03"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-43","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[-53.0416666,18.8333333],[-53.0416666,12.8333333],[-52.8333333,12.8333333],[-50.5,12.8333333],[-50.5,18.8333333]],"sourceHandles":["28BFF","28C00","28C04"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-44","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[-56.1666666,18.8333333],[-56.1666666,12.8333333],[-53.8333333,12.8333333],[-53.625,12.8333333],[-53.625,18.8333333]],"sourceHandles":["28C31","28C32","28C33"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-45","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[-59.7083333,18.8333333],[-59.7083333,12.8333333],[-59.5,12.8333333],[-57.1666666,12.8333333],[-57.1666666,18.8333333]],"sourceHandles":["28C2F","28C30","28C34"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-46","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[-62.8333333,18.8333333],[-62.8333333,12.8333333],[-60.5,12.8333333],[-60.2916666,12.8333333],[-60.2916666,18.8333333]],"sourceHandles":["28C61","28C62","28C63"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-47","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[-66.375,18.8333333],[-66.375,12.8333333],[-66.1666666,12.8333333],[-63.8333333,12.8333333],[-63.8333333,18.8333333]],"sourceHandles":["28C5F","28C60","28C64"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-48","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[-69.5,18.8333333],[-69.5,12.8333333],[-67.1666666,12.8333333],[-66.9583333,12.8333333],[-66.9583333,18.8333333]],"sourceHandles":["28C91","28C92","28C93"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-49","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[-73.0416666,18.8333333],[-73.0416666,12.8333333],[-72.8333333,12.8333333],[-70.5,12.8333333],[-70.5,18.8333333]],"sourceHandles":["28C8F","28C90","28C94"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-50","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[-76.1666666,18.8333333],[-76.1666666,12.8333333],[-73.8333333,12.8333333],[-73.625,12.8333333],[-73.625,18.8333333]],"sourceHandles":["28CC1","28CC2","28CC3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-51","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[-79.7083333,18.8333333],[-79.7083333,12.8333333],[-79.5,12.8333333],[-77.1666666,12.8333333],[-77.1666666,18.8333333]],"sourceHandles":["28CBF","28CC0","28CC4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-52","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[-82.8333333,18.8333333],[-82.8333333,12.8333333],[-80.5,12.8333333],[-80.2916666,12.8333333],[-80.2916666,18.8333333]],"sourceHandles":["28CF1","28CF2","28CF3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-53","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[-86.375,18.8333333],[-86.375,12.8333333],[-86.1666666,12.8333333],[-83.8333333,12.8333333],[-83.8333333,18.8333333]],"sourceHandles":["28CEF","28CF0","28CF4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-54","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[-89.5,18.8333333],[-89.5,12.8333333],[-87.1666666,12.8333333],[-86.9583333,12.8333333],[-86.9583333,18.8333333]],"sourceHandles":["28D21","28D22","28D23"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-55","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[-93.0416666,18.8333333],[-93.0416666,12.8333333],[-92.8333333,12.8333333],[-90.5,12.8333333],[-90.5,18.8333333]],"sourceHandles":["28D1F","28D20","28D24"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-56","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[-96.1668614,18.8333333],[-96.1668614,17.5049035],[-96.1668614,17.5],[-96.1668614,12.8333333],[-93.8333333,12.8333333],[-93.625,12.8333333],[-93.625,18.8333333]],"sourceHandles":["28D46","28D47","28D48"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-108-57","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[93.625,46.8333333],[93.625,39.5833333],[96.1666667,39.5833333],[96.1666667,46.8333333]],"sourceHandles":["28802","28810","28DBA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-0","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[90.5,46.8333333],[90.5,39.5833333],[93.0416667,39.5833333],[93.0416667,46.8333333]],"sourceHandles":["2880A","28811","28812"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-1","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[86.9583334,46.8333333],[86.9583334,39.5833333],[89.5,39.5833333],[89.5,46.8333333]],"sourceHandles":["2880B","28813","28814"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-2","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[83.8333334,46.8333333],[83.8333334,39.5833333],[86.375,39.5833333],[86.375,46.8333333]],"sourceHandles":["28815","28849","28D4D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-3","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[80.2916667,46.8333333],[80.2916667,39.5833333],[82.8333334,39.5833333],[82.8333334,46.8333333]],"sourceHandles":["2884A","28D4E","28D4F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-4","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[77.1666667,46.8333333],[77.1666667,39.5833333],[79.7083334,39.5833333],[79.7083334,46.8333333]],"sourceHandles":["28879","28D50","28D51"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-5","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[73.625,46.8333333],[73.625,39.5833333],[76.1666667,39.5833333],[76.1666667,46.8333333]],"sourceHandles":["2887A","28D52","28D53"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-6","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[70.5,46.8333333],[70.5,39.5833333],[73.0416667,39.5833333],[73.0416667,46.8333333]],"sourceHandles":["288A9","28D54","28D55"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-7","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[66.9583334,46.8333333],[66.9583334,39.5833333],[69.5,39.5833333],[69.5,46.8333333]],"sourceHandles":["288AA","28D56","28D57"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-8","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[63.8333334,46.8333333],[63.8333334,39.5833333],[66.375,39.5833333],[66.375,46.8333333]],"sourceHandles":["288D9","28D58","28D59"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-9","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[60.2916667,46.8333333],[60.2916667,39.5833333],[62.8333334,39.5833333],[62.8333334,46.8333333]],"sourceHandles":["288DA","28D5A","28D5B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-10","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[57.1666667,46.8333333],[57.1666667,39.5833333],[59.7083334,39.5833333],[59.7083334,46.8333333]],"sourceHandles":["28909","28D5C","28D5D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-11","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[53.625,46.8333333],[53.625,39.5833333],[56.1666667,39.5833333],[56.1666667,46.8333333]],"sourceHandles":["2890A","28D5E","28D5F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-12","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[50.5,46.8333333],[50.5,39.5833333],[53.0416667,39.5833333],[53.0416667,46.8333333]],"sourceHandles":["28939","28D60","28D61"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-13","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[46.9583334,46.8333333],[46.9583334,39.5833333],[49.5,39.5833333],[49.5,46.8333333]],"sourceHandles":["2893A","28D62","28D63"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-14","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[43.8333334,46.8333333],[43.8333334,39.5833333],[46.375,39.5833333],[46.375,46.8333333]],"sourceHandles":["28969","28D64","28D65"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-15","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[40.2916667,46.8333333],[40.2916667,39.5833333],[42.8333334,39.5833333],[42.8333334,46.8333333]],"sourceHandles":["2896A","28D66","28D67"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-16","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[37.1666667,46.8333333],[37.1666667,39.5833333],[39.7083334,39.5833333],[39.7083334,46.8333333]],"sourceHandles":["28999","28D68","28D69"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-17","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[33.625,46.8333333],[33.625,39.5833333],[36.1666667,39.5833333],[36.1666667,46.8333333]],"sourceHandles":["2899A","28D6A","28D6B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-18","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[30.5,46.8333333],[30.5,39.5833333],[33.0416667,39.5833333],[33.0416667,46.8333333]],"sourceHandles":["289C9","28D6C","28D6D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-19","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[26.9583334,46.8333333],[26.9583334,39.5833333],[29.5,39.5833333],[29.5,46.8333333]],"sourceHandles":["289CA","28D6E","28D6F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-20","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[23.8333334,46.8333333],[23.8333334,39.5833333],[26.375,39.5833333],[26.375,46.8333333]],"sourceHandles":["289F9","28D70","28D71"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-21","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[20.2916667,46.8333333],[20.2916667,39.5833333],[22.8333334,39.5833333],[22.8333334,46.8333333]],"sourceHandles":["289FA","28D72","28D73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-22","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[17.1666667,46.8333333],[17.1666667,39.5833333],[19.7083334,39.5833333],[19.7083334,46.8333333]],"sourceHandles":["28A29","28D74","28D75"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-23","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[13.625,46.8333333],[13.625,39.5833333],[16.1666667,39.5833333],[16.1666667,46.8333333]],"sourceHandles":["28A2A","28D76","28D77"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-24","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[10.5,46.8333333],[10.5,39.5833333],[13.0416667,39.5833333],[13.0416667,46.8333333]],"sourceHandles":["28A59","28D78","28D79"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-25","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[6.9583334,46.8333333],[6.9583334,39.5833333],[9.5,39.5833333],[9.5,46.8333333]],"sourceHandles":["28A5A","28D7A","28D7B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-26","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[3.8333334,46.8333333],[3.8333334,39.5833333],[6.375,39.5833333],[6.375,46.8333333]],"sourceHandles":["28A89","28D7C","28D7D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-27","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[0.2916667,46.8333333],[0.2916667,39.5833333],[2.8333334,39.5833333],[2.8333334,46.8333333]],"sourceHandles":["28A8A","28D7E","28D7F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-28","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[-2.8333333,46.8333333],[-2.8333333,39.5833333],[-0.2916666,39.5833333],[-0.2916666,46.8333333]],"sourceHandles":["28AB9","28D80","28D81"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-29","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[-6.375,46.8333333],[-6.375,39.5833333],[-3.8333333,39.5833333],[-3.8333333,46.8333333]],"sourceHandles":["28ABA","28D82","28D83"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-30","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[-9.5,46.8333333],[-9.5,39.5833333],[-6.9583333,39.5833333],[-6.9583333,46.8333333]],"sourceHandles":["28AE9","28D84","28D85"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-31","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[-13.0416666,46.8333333],[-13.0416666,39.5833333],[-10.5,39.5833333],[-10.5,46.8333333]],"sourceHandles":["28AEA","28D86","28D87"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-32","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[-16.1666666,46.8333333],[-16.1666666,39.5833333],[-13.625,39.5833333],[-13.625,46.8333333]],"sourceHandles":["28B19","28D88","28D89"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-33","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[-19.7083333,46.8333333],[-19.7083333,39.5833333],[-17.1666666,39.5833333],[-17.1666666,46.8333333]],"sourceHandles":["28B1A","28D8A","28D8B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-34","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[-22.8333333,46.8333333],[-22.8333333,39.5833333],[-20.2916666,39.5833333],[-20.2916666,46.8333333]],"sourceHandles":["28B49","28D8C","28D8D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-35","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[-26.375,46.8333333],[-26.375,39.5833333],[-23.8333333,39.5833333],[-23.8333333,46.8333333]],"sourceHandles":["28B4A","28D8E","28D8F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-36","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[-29.5,46.8333333],[-29.5,39.5833333],[-26.9583333,39.5833333],[-26.9583333,46.8333333]],"sourceHandles":["28B79","28D90","28D91"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-37","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[-33.0416666,46.8333333],[-33.0416666,39.5833333],[-30.5,39.5833333],[-30.5,46.8333333]],"sourceHandles":["28B7A","28D92","28D93"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-38","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[-36.1666666,46.8333333],[-36.1666666,39.5833333],[-33.625,39.5833333],[-33.625,46.8333333]],"sourceHandles":["28BA9","28D94","28D95"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-39","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[-39.7083333,46.8333333],[-39.7083333,39.5833333],[-37.1666666,39.5833333],[-37.1666666,46.8333333]],"sourceHandles":["28BAA","28D96","28D97"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-40","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[-42.8333333,46.8333333],[-42.8333333,39.5833333],[-40.2916666,39.5833333],[-40.2916666,46.8333333]],"sourceHandles":["28BD9","28D98","28D99"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-41","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[-46.375,46.8333333],[-46.375,39.5833333],[-43.8333333,39.5833333],[-43.8333333,46.8333333]],"sourceHandles":["28BDA","28D9A","28D9B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-42","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[-49.5,46.8333333],[-49.5,39.5833333],[-46.9583333,39.5833333],[-46.9583333,46.8333333]],"sourceHandles":["28C09","28D9C","28D9D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-43","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[-53.0416666,46.8333333],[-53.0416666,39.5833333],[-50.5,39.5833333],[-50.5,46.8333333]],"sourceHandles":["28C0A","28D9E","28D9F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-44","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[-56.1666666,46.8333333],[-56.1666666,39.5833333],[-53.625,39.5833333],[-53.625,46.8333333]],"sourceHandles":["28C39","28DA0","28DA1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-45","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[-59.7083333,46.8333333],[-59.7083333,39.5833333],[-57.1666666,39.5833333],[-57.1666666,46.8333333]],"sourceHandles":["28C3A","28DA2","28DA3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-46","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[-62.8333333,46.8333333],[-62.8333333,39.5833333],[-60.2916666,39.5833333],[-60.2916666,46.8333333]],"sourceHandles":["28C69","28DA4","28DA5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-47","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[-66.375,46.8333333],[-66.375,39.5833333],[-63.8333333,39.5833333],[-63.8333333,46.8333333]],"sourceHandles":["28C6A","28DA6","28DA7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-48","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[-69.5,46.8333333],[-69.5,39.5833333],[-66.9583333,39.5833333],[-66.9583333,46.8333333]],"sourceHandles":["28C99","28DA8","28DA9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-49","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[-73.0416666,46.8333333],[-73.0416666,39.5833333],[-70.5,39.5833333],[-70.5,46.8333333]],"sourceHandles":["28C9A","28DAA","28DAB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-50","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[-76.1666666,46.8333333],[-76.1666666,39.5833333],[-73.625,39.5833333],[-73.625,46.8333333]],"sourceHandles":["28CC9","28DAC","28DAD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-51","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[-79.7083333,46.8333333],[-79.7083333,39.5833333],[-77.1666666,39.5833333],[-77.1666666,46.8333333]],"sourceHandles":["28CCA","28DAE","28DAF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-52","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[-82.8333333,46.8333333],[-82.8333333,39.5833333],[-80.2916666,39.5833333],[-80.2916666,46.8333333]],"sourceHandles":["28CF9","28DB0","28DB1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-53","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[-86.375,46.8333333],[-86.375,39.5833333],[-83.8333333,39.5833333],[-83.8333333,46.8333333]],"sourceHandles":["28CFA","28DB2","28DB3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-54","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[-89.5,46.8333333],[-89.5,39.5833333],[-86.9583333,39.5833333],[-86.9583333,46.8333333]],"sourceHandles":["28D29","28DB4","28DB5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-55","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[-93.0416666,46.8333333],[-93.0416666,39.5833333],[-90.5,39.5833333],[-90.5,46.8333333]],"sourceHandles":["28D2A","28DB6","28DB7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-56","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[-96.1668614,46.8333333],[-96.1668614,39.5833333],[-93.625,39.5833333],[-93.625,46.8333333]],"sourceHandles":["28DB8","28DB9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-east-spandrel-110-57","tower":2,"face":"east","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":359,"columnIndex":0,"outlineFt":[[-98.375,-5.8333334],[-98.375,-0.0],[-98.375,1.25],[-98.375,17.5],[-98.375,22.1666666],[-98.375,37.5],[-98.375,49.0833333],[-96.1666666,49.0833333],[-96.1666666,37.5],[-95.9791666,37.5],[-95.9791666,22.1666666],[-96.1666666,22.1666666],[-96.1666666,17.5],[-96.1666666,1.25],[-96.1170343,-0.0],[-95.8854166,-5.8333334]],"sourceHandles":["1EC51","1EC53","1EC5A","1EC5B","1EC5E","1F31A","1F31B","1F31F"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":359,"id":"upper-exterior-1-south-column-359","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":358,"columnIndex":1,"outlineFt":[[-94.1145833,-5.8333334],[-93.8333333,1.25],[-93.8333333,12.8333333],[-93.625,12.8333333],[-93.625,22.1666666],[-93.625,37.5],[-93.625,46.8333333],[-93.0416666,46.8333333],[-93.0416666,37.5],[-93.0416666,22.1666666],[-93.0416666,12.8333333],[-92.8333333,12.8333333],[-92.8333333,1.25],[-92.5520833,-5.8333334]],"sourceHandles":["1EC4B","1EC4C","1EC4F","1EC50","1EDD3","1EDD4","1EDD7","1EDD8","1EDEB","1EDEC","1EE04","1EE05"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":358,"id":"upper-exterior-1-south-column-358","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":357,"columnIndex":2,"outlineFt":[[-90.78125,-5.8333334],[-90.5,1.25],[-90.5,12.8333333],[-90.5,22.1666666],[-90.6875,22.1666666],[-90.6875,37.5],[-90.5,37.5],[-90.5,46.8333333],[-89.5,46.8333333],[-89.5,37.5],[-89.3125,37.5],[-89.3125,22.1666666],[-89.5,22.1666666],[-89.5,12.8333333],[-89.5,1.25],[-89.21875,-5.8333334]],"sourceHandles":["1EC4D","1EC60","1EC63","1EC64","1EDC3","1EDC4","1EDC9","1EDCA","1EDCB","1EDCC"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":357,"id":"upper-exterior-1-south-column-357","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":356,"columnIndex":3,"outlineFt":[[-87.4479166,-5.8333334],[-87.1666666,1.25],[-87.1666666,12.8333333],[-86.9583333,12.8333333],[-86.9583333,22.1666666],[-86.9583333,37.5],[-86.9583333,46.8333333],[-86.375,46.8333333],[-86.375,37.5],[-86.375,22.1666666],[-86.375,12.8333333],[-86.1666666,12.8333333],[-86.1666666,1.25],[-85.8854166,-5.8333334]],"sourceHandles":["1EC61","1EC66","1EC69","1EC6A","1EDBD","1EDBE","1EDC7","1EDC8","1EDED","1EDEE","1EDFA","1EDFB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":356,"id":"upper-exterior-1-south-column-356","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":355,"columnIndex":4,"outlineFt":[[-84.1145833,-5.8333334],[-83.8333333,1.25],[-83.8333333,12.8333333],[-83.8333333,22.1666666],[-84.0208333,22.1666666],[-84.0208333,37.5],[-83.8333333,37.5],[-83.8333333,46.8333333],[-82.8333333,46.8333333],[-82.8333333,37.5],[-82.6458333,37.5],[-82.6458333,22.1666666],[-82.8333333,22.1666666],[-82.8333333,12.8333333],[-82.8333333,1.25],[-82.5520833,-5.8333334]],"sourceHandles":["1EC67","1EC6C","1EC6F","1EC70","1EE0E","1EE0F","1EE14","1EE15","1EE16","1EE17"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":355,"id":"upper-exterior-1-south-column-355","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":354,"columnIndex":5,"outlineFt":[[-80.78125,-5.8333334],[-80.5,1.25],[-80.5,12.8333333],[-80.2916666,12.8333333],[-80.2916666,22.1666666],[-80.2916666,37.5],[-80.2916666,46.8333333],[-79.7083333,46.8333333],[-79.7083333,37.5],[-79.7083333,22.1666666],[-79.7083333,12.8333333],[-79.5,12.8333333],[-79.5,1.25],[-79.21875,-5.8333334]],"sourceHandles":["1EC6D","1EC72","1EC75","1EC76","1EE0A","1EE0B","1EE12","1EE13","1EE2A","1EE2B","1EE31","1EE32"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":354,"id":"upper-exterior-1-south-column-354","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":353,"columnIndex":6,"outlineFt":[[-77.4479166,-5.8333334],[-77.1666666,1.25],[-77.1666666,12.8333333],[-77.1666666,22.1666666],[-77.3541666,22.1666666],[-77.3541666,37.5],[-77.1666666,37.5],[-77.1666666,46.8333333],[-76.1666666,46.8333333],[-76.1666666,37.5],[-75.9791666,37.5],[-75.9791666,22.1666666],[-76.1666666,22.1666666],[-76.1666666,12.8333333],[-76.1666666,1.25],[-75.8854166,-5.8333334]],"sourceHandles":["1EC73","1EC78","1EC7B","1EC7C","1EE3E","1EE3F","1EE44","1EE45","1EE46","1EE47"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":353,"id":"upper-exterior-1-south-column-353","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":352,"columnIndex":7,"outlineFt":[[-74.1145833,-5.8333334],[-73.8333333,1.25],[-73.8333333,12.8333333],[-73.625,12.8333333],[-73.625,22.1666666],[-73.625,37.5],[-73.625,46.8333333],[-73.0416666,46.8333333],[-73.0416666,37.5],[-73.0416666,22.1666666],[-73.0416666,12.8333333],[-72.8333333,12.8333333],[-72.8333333,1.25],[-72.5520833,-5.8333334]],"sourceHandles":["1EC79","1EC7E","1EC81","1EC82","1EE3A","1EE3B","1EE42","1EE43","1EE5A","1EE5B","1EE61","1EE62"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":352,"id":"upper-exterior-1-south-column-352","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":351,"columnIndex":8,"outlineFt":[[-70.78125,-5.8333334],[-70.5,1.25],[-70.5,12.8333333],[-70.5,22.1666666],[-70.6875,22.1666666],[-70.6875,37.5],[-70.5,37.5],[-70.5,46.8333333],[-69.5,46.8333333],[-69.5,37.5],[-69.3125,37.5],[-69.3125,22.1666666],[-69.5,22.1666666],[-69.5,12.8333333],[-69.5,1.25],[-69.21875,-5.8333334]],"sourceHandles":["1EC7F","1EC84","1EC87","1EC88","1EE6E","1EE6F","1EE74","1EE75","1EE76","1EE77"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":351,"id":"upper-exterior-1-south-column-351","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":350,"columnIndex":9,"outlineFt":[[-67.4479166,-5.8333334],[-67.1666666,1.25],[-67.1666666,12.8333333],[-66.9583333,12.8333333],[-66.9583333,22.1666666],[-66.9583333,37.5],[-66.9583333,46.8333333],[-66.375,46.8333333],[-66.375,37.5],[-66.375,22.1666666],[-66.375,12.8333333],[-66.1666666,12.8333333],[-66.1666666,1.25],[-65.8854166,-5.8333334]],"sourceHandles":["1EC85","1EC8A","1EC8D","1EC8E","1EE6A","1EE6B","1EE72","1EE73","1EE8A","1EE8B","1EE91","1EE92"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":350,"id":"upper-exterior-1-south-column-350","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":349,"columnIndex":10,"outlineFt":[[-64.1145833,-5.8333334],[-63.8333333,1.25],[-63.8333333,12.8333333],[-63.8333333,22.1666666],[-64.0208333,22.1666666],[-64.0208333,37.5],[-63.8333333,37.5],[-63.8333333,46.8333333],[-62.8333333,46.8333333],[-62.8333333,37.5],[-62.6458333,37.5],[-62.6458333,22.1666666],[-62.8333333,22.1666666],[-62.8333333,12.8333333],[-62.8333333,1.25],[-62.5520833,-5.8333334]],"sourceHandles":["1EC8B","1EC90","1EC93","1EC94","1EE9E","1EE9F","1EEA4","1EEA5","1EEA6","1EEA7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":349,"id":"upper-exterior-1-south-column-349","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":348,"columnIndex":11,"outlineFt":[[-60.78125,-5.8333334],[-60.5,1.25],[-60.5,12.8333333],[-60.2916666,12.8333333],[-60.2916666,22.1666666],[-60.2916666,37.5],[-60.2916666,46.8333333],[-59.7083333,46.8333333],[-59.7083333,37.5],[-59.7083333,22.1666666],[-59.7083333,12.8333333],[-59.5,12.8333333],[-59.5,1.25],[-59.21875,-5.8333334]],"sourceHandles":["1EC91","1EC96","1EC99","1EC9A","1EE9A","1EE9B","1EEA2","1EEA3","1EEBA","1EEBB","1EEC1","1EEC2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":348,"id":"upper-exterior-1-south-column-348","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":347,"columnIndex":12,"outlineFt":[[-57.4479166,-5.8333334],[-57.1666666,1.25],[-57.1666666,12.8333333],[-57.1666666,22.1666666],[-57.3541666,22.1666666],[-57.3541666,37.5],[-57.1666666,37.5],[-57.1666666,46.8333333],[-56.1666666,46.8333333],[-56.1666666,37.5],[-55.9791666,37.5],[-55.9791666,22.1666666],[-56.1666666,22.1666666],[-56.1666666,12.8333333],[-56.1666666,1.25],[-55.8854166,-5.8333334]],"sourceHandles":["1EC97","1EC9C","1EC9F","1ECA0","1EECE","1EECF","1EED4","1EED5","1EED6","1EED7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":347,"id":"upper-exterior-1-south-column-347","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":346,"columnIndex":13,"outlineFt":[[-54.1145833,-5.8333334],[-53.8333333,1.25],[-53.8333333,12.8333333],[-53.625,12.8333333],[-53.625,22.1666666],[-53.625,37.5],[-53.625,46.8333333],[-53.0416666,46.8333333],[-53.0416666,37.5],[-53.0416666,22.1666666],[-53.0416666,12.8333333],[-52.8333333,12.8333333],[-52.8333333,1.25],[-52.5520833,-5.8333334]],"sourceHandles":["1EC9D","1ECA2","1ECA5","1ECA6","1EECA","1EECB","1EED2","1EED3","1EEEA","1EEEB","1EEF1","1EEF2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":346,"id":"upper-exterior-1-south-column-346","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":345,"columnIndex":14,"outlineFt":[[-50.78125,-5.8333334],[-50.5,1.25],[-50.5,12.8333333],[-50.5,22.1666666],[-50.6875,22.1666666],[-50.6875,37.5],[-50.5,37.5],[-50.5,46.8333333],[-49.5,46.8333333],[-49.5,37.5],[-49.3125,37.5],[-49.3125,22.1666666],[-49.5,22.1666666],[-49.5,12.8333333],[-49.5,1.25],[-49.21875,-5.8333334]],"sourceHandles":["1ECA3","1ECA8","1ECAB","1ECAC","1EEFE","1EEFF","1EF04","1EF05","1EF06","1EF07"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":345,"id":"upper-exterior-1-south-column-345","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":344,"columnIndex":15,"outlineFt":[[-47.4479166,-5.8333334],[-47.1666666,1.25],[-47.1666666,12.8333333],[-46.9583333,12.8333333],[-46.9583333,22.1666666],[-46.9583333,37.5],[-46.9583333,46.8333333],[-46.375,46.8333333],[-46.375,37.5],[-46.375,22.1666666],[-46.375,12.8333333],[-46.1666666,12.8333333],[-46.1666666,1.25],[-45.8854166,-5.8333334]],"sourceHandles":["1ECA9","1ECAE","1ECB1","1ECB2","1EEFA","1EEFB","1EF02","1EF03","1EF1A","1EF1B","1EF21","1EF22"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":344,"id":"upper-exterior-1-south-column-344","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":343,"columnIndex":16,"outlineFt":[[-44.1145833,-5.8333334],[-43.8333333,1.25],[-43.8333333,12.8333333],[-43.8333333,22.1666666],[-44.0208333,22.1666666],[-44.0208333,37.5],[-43.8333333,37.5],[-43.8333333,46.8333333],[-42.8333333,46.8333333],[-42.8333333,37.5],[-42.6458333,37.5],[-42.6458333,22.1666666],[-42.8333333,22.1666666],[-42.8333333,12.8333333],[-42.8333333,1.25],[-42.5520833,-5.8333334]],"sourceHandles":["1ECAF","1ECB4","1ECB7","1ECB8","1EF2E","1EF2F","1EF34","1EF35","1EF36","1EF37"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":343,"id":"upper-exterior-1-south-column-343","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":342,"columnIndex":17,"outlineFt":[[-40.78125,-5.8333334],[-40.5,1.25],[-40.5,12.8333333],[-40.2916666,12.8333333],[-40.2916666,22.1666666],[-40.2916666,37.5],[-40.2916666,46.8333333],[-39.7083333,46.8333333],[-39.7083333,37.5],[-39.7083333,22.1666666],[-39.7083333,12.8333333],[-39.5,12.8333333],[-39.5,1.25],[-39.21875,-5.8333334]],"sourceHandles":["1ECB5","1ECBA","1ECBD","1ECBE","1EF2A","1EF2B","1EF32","1EF33","1EF4A","1EF4B","1EF51","1EF52"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":342,"id":"upper-exterior-1-south-column-342","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":341,"columnIndex":18,"outlineFt":[[-37.4479166,-5.8333334],[-37.1666666,1.25],[-37.1666666,12.8333333],[-37.1666666,22.1666666],[-37.3541666,22.1666666],[-37.3541666,37.5],[-37.1666666,37.5],[-37.1666666,46.8333333],[-36.1666666,46.8333333],[-36.1666666,37.5],[-35.9791666,37.5],[-35.9791666,22.1666666],[-36.1666666,22.1666666],[-36.1666666,12.8333333],[-36.1666666,1.25],[-35.8854166,-5.8333334]],"sourceHandles":["1ECBB","1ECC0","1ECC3","1ECC4","1EF5E","1EF5F","1EF64","1EF65","1EF66","1EF67"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":341,"id":"upper-exterior-1-south-column-341","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":340,"columnIndex":19,"outlineFt":[[-34.1145833,-5.8333334],[-33.8333333,1.25],[-33.8333333,12.8333333],[-33.625,12.8333333],[-33.625,22.1666666],[-33.625,37.5],[-33.625,46.8333333],[-33.0416666,46.8333333],[-33.0416666,37.5],[-33.0416666,22.1666666],[-33.0416666,12.8333333],[-32.8333333,12.8333333],[-32.8333333,1.25],[-32.5520833,-5.8333334]],"sourceHandles":["1ECC1","1ECC6","1ECC9","1ECCA","1EF5A","1EF5B","1EF62","1EF63","1EF7A","1EF7B","1EF81","1EF82"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":340,"id":"upper-exterior-1-south-column-340","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":339,"columnIndex":20,"outlineFt":[[-30.78125,-5.8333334],[-30.5,1.25],[-30.5,12.8333333],[-30.5,22.1666666],[-30.6875,22.1666666],[-30.6875,37.5],[-30.5,37.5],[-30.5,46.8333333],[-29.5,46.8333333],[-29.5,37.5],[-29.3125,37.5],[-29.3125,22.1666666],[-29.5,22.1666666],[-29.5,12.8333333],[-29.5,1.25],[-29.21875,-5.8333334]],"sourceHandles":["1ECC7","1ECCC","1ECCF","1ECD0","1EF8E","1EF8F","1EF94","1EF95","1EF96","1EF97"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":339,"id":"upper-exterior-1-south-column-339","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":338,"columnIndex":21,"outlineFt":[[-27.4479166,-5.8333334],[-27.1666666,1.25],[-27.1666666,12.8333333],[-26.9583333,12.8333333],[-26.9583333,22.1666666],[-26.9583333,37.5],[-26.9583333,46.8333333],[-26.375,46.8333333],[-26.375,37.5],[-26.375,22.1666666],[-26.375,12.8333333],[-26.1666666,12.8333333],[-26.1666666,1.25],[-25.8854166,-5.8333334]],"sourceHandles":["1ECCD","1ECD2","1ECD5","1ECD6","1EF8A","1EF8B","1EF92","1EF93","1EFAA","1EFAB","1EFB1","1EFB2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":338,"id":"upper-exterior-1-south-column-338","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":337,"columnIndex":22,"outlineFt":[[-24.1145833,-5.8333334],[-23.8333333,1.25],[-23.8333333,12.8333333],[-23.8333333,22.1666666],[-24.0208333,22.1666666],[-24.0208333,37.5],[-23.8333333,37.5],[-23.8333333,46.8333333],[-22.8333333,46.8333333],[-22.8333333,37.5],[-22.6458333,37.5],[-22.6458333,22.1666666],[-22.8333333,22.1666666],[-22.8333333,12.8333333],[-22.8333333,1.25],[-22.5520833,-5.8333334]],"sourceHandles":["1ECD3","1ECD8","1ECDB","1ECDC","1EFBE","1EFBF","1EFC4","1EFC5","1EFC6","1EFC7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":337,"id":"upper-exterior-1-south-column-337","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":336,"columnIndex":23,"outlineFt":[[-20.78125,-5.8333334],[-20.5,1.25],[-20.5,12.8333333],[-20.2916666,12.8333333],[-20.2916666,22.1666666],[-20.2916666,37.5],[-20.2916666,46.8333333],[-19.7083333,46.8333333],[-19.7083333,37.5],[-19.7083333,22.1666666],[-19.7083333,12.8333333],[-19.5,12.8333333],[-19.5,1.25],[-19.21875,-5.8333334]],"sourceHandles":["1ECD9","1ECDE","1ECE1","1ECE2","1EFBA","1EFBB","1EFC2","1EFC3","1EFDA","1EFDB","1EFE1","1EFE2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":336,"id":"upper-exterior-1-south-column-336","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":335,"columnIndex":24,"outlineFt":[[-17.4479166,-5.8333334],[-17.1666666,1.25],[-17.1666666,12.8333333],[-17.1666666,22.1666666],[-17.3541666,22.1666666],[-17.3541666,37.5],[-17.1666666,37.5],[-17.1666666,46.8333333],[-16.1666666,46.8333333],[-16.1666666,37.5],[-15.9791666,37.5],[-15.9791666,22.1666666],[-16.1666666,22.1666666],[-16.1666666,12.8333333],[-16.1666666,1.25],[-15.8854166,-5.8333334]],"sourceHandles":["1ECDF","1ECE4","1ECE7","1ECE8","1EFEE","1EFEF","1EFF4","1EFF5","1EFF6","1EFF7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":335,"id":"upper-exterior-1-south-column-335","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":334,"columnIndex":25,"outlineFt":[[-14.1145833,-5.8333334],[-13.8333333,1.25],[-13.8333333,12.8333333],[-13.625,12.8333333],[-13.625,22.1666666],[-13.625,37.5],[-13.625,46.8333333],[-13.0416666,46.8333333],[-13.0416666,37.5],[-13.0416666,22.1666666],[-13.0416666,12.8333333],[-12.8333333,12.8333333],[-12.8333333,1.25],[-12.5520833,-5.8333334]],"sourceHandles":["1ECE5","1ECEA","1ECED","1ECEE","1EFEA","1EFEB","1EFF2","1EFF3","1F00A","1F00B","1F011","1F012"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":334,"id":"upper-exterior-1-south-column-334","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":333,"columnIndex":26,"outlineFt":[[-10.78125,-5.8333334],[-10.5,1.25],[-10.5,12.8333333],[-10.5,22.1666666],[-10.6875,22.1666666],[-10.6875,37.5],[-10.5,37.5],[-10.5,46.8333333],[-9.5,46.8333333],[-9.5,37.5],[-9.3125,37.5],[-9.3125,22.1666666],[-9.5,22.1666666],[-9.5,12.8333333],[-9.5,1.25],[-9.21875,-5.8333334]],"sourceHandles":["1ECEB","1ECF0","1ECF3","1ECF4","1F01E","1F01F","1F024","1F025","1F026","1F027"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":333,"id":"upper-exterior-1-south-column-333","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":332,"columnIndex":27,"outlineFt":[[-7.4479166,-5.8333334],[-7.1666666,1.25],[-7.1666666,12.8333333],[-6.9583333,12.8333333],[-6.9583333,22.1666666],[-6.9583333,37.5],[-6.9583333,46.8333333],[-6.375,46.8333333],[-6.375,37.5],[-6.375,22.1666666],[-6.375,12.8333333],[-6.1666666,12.8333333],[-6.1666666,1.25],[-5.8854166,-5.8333334]],"sourceHandles":["1ECF1","1ECF6","1ECF9","1ECFA","1F01A","1F01B","1F022","1F023","1F03A","1F03B","1F041","1F042"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":332,"id":"upper-exterior-1-south-column-332","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":331,"columnIndex":28,"outlineFt":[[-4.1145833,-5.8333334],[-3.8333333,1.25],[-3.8333333,12.8333333],[-3.8333333,22.1666666],[-4.0208333,22.1666666],[-4.0208333,37.5],[-3.8333333,37.5],[-3.8333333,46.8333333],[-2.8333333,46.8333333],[-2.8333333,37.5],[-2.6458333,37.5],[-2.6458333,22.1666666],[-2.8333333,22.1666666],[-2.8333333,12.8333333],[-2.8333333,1.25],[-2.5520833,-5.8333334]],"sourceHandles":["1ECF7","1ECFC","1ECFF","1ED00","1F04E","1F04F","1F054","1F055","1F056","1F057"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":331,"id":"upper-exterior-1-south-column-331","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":330,"columnIndex":29,"outlineFt":[[-0.78125,-5.8333334],[-0.5,1.25],[-0.5,12.8333333],[-0.2916666,12.8333333],[-0.2916666,22.1666666],[-0.2916666,37.5],[-0.2916666,46.8333333],[0.2916667,46.8333333],[0.2916667,37.5],[0.2916667,22.1666666],[0.2916667,12.8333333],[0.5,12.8333333],[0.5,1.25],[0.78125,-5.8333334]],"sourceHandles":["1ECFD","1ED02","1ED05","1ED06","1F04A","1F04B","1F052","1F053","1F06A","1F06B","1F071","1F072"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":330,"id":"upper-exterior-1-south-column-330","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":329,"columnIndex":30,"outlineFt":[[2.5520834,-5.8333334],[2.8333334,1.25],[2.8333334,12.8333333],[2.8333334,22.1666666],[2.6458334,22.1666666],[2.6458334,37.5],[2.8333334,37.5],[2.8333334,46.8333333],[3.8333334,46.8333333],[3.8333334,37.5],[4.0208334,37.5],[4.0208334,22.1666666],[3.8333334,22.1666666],[3.8333334,12.8333333],[3.8333334,1.25],[4.1145834,-5.8333334]],"sourceHandles":["1ED03","1ED08","1ED0B","1ED0C","1F07E","1F07F","1F084","1F085","1F086","1F087"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":329,"id":"upper-exterior-1-south-column-329","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":328,"columnIndex":31,"outlineFt":[[5.8854167,-5.8333334],[6.1666667,1.25],[6.1666667,12.8333333],[6.375,12.8333333],[6.375,22.1666666],[6.375,37.5],[6.375,46.8333333],[6.9583334,46.8333333],[6.9583334,37.5],[6.9583334,22.1666666],[6.9583334,12.8333333],[7.1666667,12.8333333],[7.1666667,1.25],[7.4479167,-5.8333334]],"sourceHandles":["1ED09","1ED0E","1ED11","1ED12","1F07A","1F07B","1F082","1F083","1F09A","1F09B","1F0A1","1F0A2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":328,"id":"upper-exterior-1-south-column-328","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":327,"columnIndex":32,"outlineFt":[[9.21875,-5.8333334],[9.5,1.25],[9.5,12.8333333],[9.5,22.1666666],[9.3125,22.1666666],[9.3125,37.5],[9.5,37.5],[9.5,46.8333333],[10.5,46.8333333],[10.5,37.5],[10.6875,37.5],[10.6875,22.1666666],[10.5,22.1666666],[10.5,12.8333333],[10.5,1.25],[10.78125,-5.8333334]],"sourceHandles":["1ED0F","1ED14","1ED17","1ED18","1F0AE","1F0AF","1F0B4","1F0B5","1F0B6","1F0B7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":327,"id":"upper-exterior-1-south-column-327","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":326,"columnIndex":33,"outlineFt":[[12.5520834,-5.8333334],[12.8333334,1.25],[12.8333334,12.8333333],[13.0416667,12.8333333],[13.0416667,22.1666666],[13.0416667,37.5],[13.0416667,46.8333333],[13.625,46.8333333],[13.625,37.5],[13.625,22.1666666],[13.625,12.8333333],[13.8333334,12.8333333],[13.8333334,1.25],[14.1145834,-5.8333334]],"sourceHandles":["1ED15","1ED1A","1ED1D","1ED1E","1F0AA","1F0AB","1F0B2","1F0B3","1F0CA","1F0CB","1F0D1","1F0D2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":326,"id":"upper-exterior-1-south-column-326","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":325,"columnIndex":34,"outlineFt":[[15.8854167,-5.8333334],[16.1666667,1.25],[16.1666667,12.8333333],[16.1666667,22.1666666],[15.9791667,22.1666666],[15.9791667,37.5],[16.1666667,37.5],[16.1666667,46.8333333],[17.1666667,46.8333333],[17.1666667,37.5],[17.3541667,37.5],[17.3541667,22.1666666],[17.1666667,22.1666666],[17.1666667,12.8333333],[17.1666667,1.25],[17.4479167,-5.8333334]],"sourceHandles":["1ED1B","1ED20","1ED23","1ED24","1F0DE","1F0DF","1F0E4","1F0E5","1F0E6","1F0E7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":325,"id":"upper-exterior-1-south-column-325","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":324,"columnIndex":35,"outlineFt":[[19.21875,-5.8333334],[19.5,1.25],[19.5,12.8333333],[19.7083334,12.8333333],[19.7083334,22.1666666],[19.7083334,37.5],[19.7083334,46.8333333],[20.2916667,46.8333333],[20.2916667,37.5],[20.2916667,22.1666666],[20.2916667,12.8333333],[20.5,12.8333333],[20.5,1.25],[20.78125,-5.8333334]],"sourceHandles":["1ED21","1ED26","1ED29","1ED2A","1F0DA","1F0DB","1F0E2","1F0E3","1F0FA","1F0FB","1F101","1F102"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":324,"id":"upper-exterior-1-south-column-324","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":323,"columnIndex":36,"outlineFt":[[22.5520834,-5.8333334],[22.8333334,1.25],[22.8333334,12.8333333],[22.8333334,22.1666666],[22.6458334,22.1666666],[22.6458334,37.5],[22.8333334,37.5],[22.8333334,46.8333333],[23.8333334,46.8333333],[23.8333334,37.5],[24.0208334,37.5],[24.0208334,22.1666666],[23.8333334,22.1666666],[23.8333334,12.8333333],[23.8333334,1.25],[24.1145834,-5.8333334]],"sourceHandles":["1ED27","1ED2C","1ED2F","1ED30","1F10E","1F10F","1F114","1F115","1F116","1F117"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":323,"id":"upper-exterior-1-south-column-323","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":322,"columnIndex":37,"outlineFt":[[25.8854167,-5.8333334],[26.1666667,1.25],[26.1666667,12.8333333],[26.375,12.8333333],[26.375,22.1666666],[26.375,37.5],[26.375,46.8333333],[26.9583334,46.8333333],[26.9583334,37.5],[26.9583334,22.1666666],[26.9583334,12.8333333],[27.1666667,12.8333333],[27.1666667,1.25],[27.4479167,-5.8333334]],"sourceHandles":["1ED2D","1ED32","1ED35","1ED36","1F10A","1F10B","1F112","1F113","1F12A","1F12B","1F131","1F132"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":322,"id":"upper-exterior-1-south-column-322","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":321,"columnIndex":38,"outlineFt":[[29.21875,-5.8333334],[29.5,1.25],[29.5,12.8333333],[29.5,22.1666666],[29.3125,22.1666666],[29.3125,37.5],[29.5,37.5],[29.5,46.8333333],[30.5,46.8333333],[30.5,37.5],[30.6875,37.5],[30.6875,22.1666666],[30.5,22.1666666],[30.5,12.8333333],[30.5,1.25],[30.78125,-5.8333334]],"sourceHandles":["1ED33","1ED38","1ED3B","1ED3C","1F13E","1F13F","1F144","1F145","1F146","1F147"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":321,"id":"upper-exterior-1-south-column-321","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":320,"columnIndex":39,"outlineFt":[[32.5520834,-5.8333334],[32.8333334,1.25],[32.8333334,12.8333333],[33.0416667,12.8333333],[33.0416667,22.1666666],[33.0416667,37.5],[33.0416667,46.8333333],[33.625,46.8333333],[33.625,37.5],[33.625,22.1666666],[33.625,12.8333333],[33.8333334,12.8333333],[33.8333334,1.25],[34.1145834,-5.8333334]],"sourceHandles":["1ED39","1ED3E","1ED41","1ED42","1F13A","1F13B","1F142","1F143","1F15A","1F15B","1F161","1F162"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":320,"id":"upper-exterior-1-south-column-320","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":319,"columnIndex":40,"outlineFt":[[35.8854167,-5.8333334],[36.1666667,1.25],[36.1666667,12.8333333],[36.1666667,22.1666666],[35.9791667,22.1666666],[35.9791667,37.5],[36.1666667,37.5],[36.1666667,46.8333333],[37.1666667,46.8333333],[37.1666667,37.5],[37.3541667,37.5],[37.3541667,22.1666666],[37.1666667,22.1666666],[37.1666667,12.8333333],[37.1666667,1.25],[37.4479167,-5.8333334]],"sourceHandles":["1ED3F","1ED44","1ED47","1ED48","1F16E","1F16F","1F174","1F175","1F176","1F177"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":319,"id":"upper-exterior-1-south-column-319","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":318,"columnIndex":41,"outlineFt":[[39.21875,-5.8333334],[39.5,1.25],[39.5,12.8333333],[39.7083334,12.8333333],[39.7083334,22.1666666],[39.7083334,37.5],[39.7083334,46.8333333],[40.2916667,46.8333333],[40.2916667,37.5],[40.2916667,22.1666666],[40.2916667,12.8333333],[40.5,12.8333333],[40.5,1.25],[40.78125,-5.8333334]],"sourceHandles":["1ED45","1ED4A","1ED4D","1ED4E","1F16A","1F16B","1F172","1F173","1F18A","1F18B","1F191","1F192"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":318,"id":"upper-exterior-1-south-column-318","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":317,"columnIndex":42,"outlineFt":[[42.5520834,-5.8333334],[42.8333334,1.25],[42.8333334,12.8333333],[42.8333334,22.1666666],[42.6458334,22.1666666],[42.6458334,37.5],[42.8333334,37.5],[42.8333334,46.8333333],[43.8333334,46.8333333],[43.8333334,37.5],[44.0208334,37.5],[44.0208334,22.1666666],[43.8333334,22.1666666],[43.8333334,12.8333333],[43.8333334,1.25],[44.1145834,-5.8333334]],"sourceHandles":["1ED4B","1ED50","1ED53","1ED54","1F19E","1F19F","1F1A4","1F1A5","1F1A6","1F1A7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":317,"id":"upper-exterior-1-south-column-317","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":316,"columnIndex":43,"outlineFt":[[45.8854167,-5.8333334],[46.1666667,1.25],[46.1666667,12.8333333],[46.375,12.8333333],[46.375,22.1666666],[46.375,37.5],[46.375,46.8333333],[46.9583334,46.8333333],[46.9583334,37.5],[46.9583334,22.1666666],[46.9583334,12.8333333],[47.1666667,12.8333333],[47.1666667,1.25],[47.4479167,-5.8333334]],"sourceHandles":["1ED51","1ED56","1ED59","1ED5A","1F19A","1F19B","1F1A2","1F1A3","1F1BA","1F1BB","1F1C1","1F1C2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":316,"id":"upper-exterior-1-south-column-316","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":315,"columnIndex":44,"outlineFt":[[49.21875,-5.8333334],[49.5,1.25],[49.5,12.8333333],[49.5,22.1666666],[49.3125,22.1666666],[49.3125,37.5],[49.5,37.5],[49.5,46.8333333],[50.5,46.8333333],[50.5,37.5],[50.6875,37.5],[50.6875,22.1666666],[50.5,22.1666666],[50.5,12.8333333],[50.5,1.25],[50.78125,-5.8333334]],"sourceHandles":["1ED57","1ED5C","1ED5F","1ED60","1F1CE","1F1CF","1F1D4","1F1D5","1F1D6","1F1D7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":315,"id":"upper-exterior-1-south-column-315","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":314,"columnIndex":45,"outlineFt":[[52.5520834,-5.8333334],[52.8333334,1.25],[52.8333334,12.8333333],[53.0416667,12.8333333],[53.0416667,22.1666666],[53.0416667,37.5],[53.0416667,46.8333333],[53.625,46.8333333],[53.625,37.5],[53.625,22.1666666],[53.625,12.8333333],[53.8333334,12.8333333],[53.8333334,1.25],[54.1145834,-5.8333334]],"sourceHandles":["1ED5D","1ED62","1ED65","1ED66","1F1CA","1F1CB","1F1D2","1F1D3","1F1EA","1F1EB","1F1F1","1F1F2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":314,"id":"upper-exterior-1-south-column-314","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":313,"columnIndex":46,"outlineFt":[[55.8854167,-5.8333334],[56.1666667,1.25],[56.1666667,12.8333333],[56.1666667,22.1666666],[55.9791667,22.1666666],[55.9791667,37.5],[56.1666667,37.5],[56.1666667,46.8333333],[57.1666667,46.8333333],[57.1666667,37.5],[57.3541667,37.5],[57.3541667,22.1666666],[57.1666667,22.1666666],[57.1666667,12.8333333],[57.1666667,1.25],[57.4479167,-5.8333334]],"sourceHandles":["1ED63","1ED68","1ED6B","1ED6C","1F1FE","1F1FF","1F204","1F205","1F206","1F207"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":313,"id":"upper-exterior-1-south-column-313","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":312,"columnIndex":47,"outlineFt":[[59.21875,-5.8333334],[59.5,1.25],[59.5,12.8333333],[59.7083334,12.8333333],[59.7083334,22.1666666],[59.7083334,37.5],[59.7083334,46.8333333],[60.2916667,46.8333333],[60.2916667,37.5],[60.2916667,22.1666666],[60.2916667,12.8333333],[60.5,12.8333333],[60.5,1.25],[60.78125,-5.8333334]],"sourceHandles":["1ED69","1ED6E","1ED71","1ED72","1F1FA","1F1FB","1F202","1F203","1F21A","1F21B","1F221","1F222"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":312,"id":"upper-exterior-1-south-column-312","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":311,"columnIndex":48,"outlineFt":[[62.5520834,-5.8333334],[62.8333334,1.25],[62.8333334,12.8333333],[62.8333334,22.1666666],[62.6458334,22.1666666],[62.6458334,37.5],[62.8333334,37.5],[62.8333334,46.8333333],[63.8333334,46.8333333],[63.8333334,37.5],[64.0208334,37.5],[64.0208334,22.1666666],[63.8333334,22.1666666],[63.8333334,12.8333333],[63.8333334,1.25],[64.1145834,-5.8333334]],"sourceHandles":["1ED6F","1ED74","1ED77","1ED78","1F22E","1F22F","1F234","1F235","1F236","1F237"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":311,"id":"upper-exterior-1-south-column-311","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":310,"columnIndex":49,"outlineFt":[[65.8854167,-5.8333334],[66.1666667,1.25],[66.1666667,12.8333333],[66.375,12.8333333],[66.375,22.1666666],[66.375,37.5],[66.375,46.8333333],[66.9583334,46.8333333],[66.9583334,37.5],[66.9583334,22.1666666],[66.9583334,12.8333333],[67.1666667,12.8333333],[67.1666667,1.25],[67.4479167,-5.8333334]],"sourceHandles":["1ED75","1ED7A","1ED7D","1ED7E","1F22A","1F22B","1F232","1F233","1F24A","1F24B","1F251","1F252"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":310,"id":"upper-exterior-1-south-column-310","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":309,"columnIndex":50,"outlineFt":[[69.21875,-5.8333334],[69.5,1.25],[69.5,12.8333333],[69.5,22.1666666],[69.3125,22.1666666],[69.3125,37.5],[69.5,37.5],[69.5,46.8333333],[70.5,46.8333333],[70.5,37.5],[70.6875,37.5],[70.6875,22.1666666],[70.5,22.1666666],[70.5,12.8333333],[70.5,1.25],[70.78125,-5.8333334]],"sourceHandles":["1ED7B","1ED80","1ED83","1ED84","1F25E","1F25F","1F264","1F265","1F266","1F267"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":309,"id":"upper-exterior-1-south-column-309","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":308,"columnIndex":51,"outlineFt":[[72.5520834,-5.8333334],[72.8333334,1.25],[72.8333334,12.8333333],[73.0416667,12.8333333],[73.0416667,22.1666666],[73.0416667,37.5],[73.0416667,46.8333333],[73.625,46.8333333],[73.625,37.5],[73.625,22.1666666],[73.625,12.8333333],[73.8333334,12.8333333],[73.8333334,1.25],[74.1145834,-5.8333334]],"sourceHandles":["1ED81","1ED86","1ED89","1ED8A","1F25A","1F25B","1F262","1F263","1F27A","1F27B","1F281","1F282"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":308,"id":"upper-exterior-1-south-column-308","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":307,"columnIndex":52,"outlineFt":[[75.8854167,-5.8333334],[76.1666667,1.25],[76.1666667,12.8333333],[76.1666667,22.1666666],[75.9791667,22.1666666],[75.9791667,37.5],[76.1666667,37.5],[76.1666667,46.8333333],[77.1666667,46.8333333],[77.1666667,37.5],[77.3541667,37.5],[77.3541667,22.1666666],[77.1666667,22.1666666],[77.1666667,12.8333333],[77.1666667,1.25],[77.4479167,-5.8333334]],"sourceHandles":["1ED87","1ED8C","1ED8F","1ED90","1F28E","1F28F","1F294","1F295","1F296","1F297"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":307,"id":"upper-exterior-1-south-column-307","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":306,"columnIndex":53,"outlineFt":[[79.21875,-5.8333334],[79.5,1.25],[79.5,12.8333333],[79.7083334,12.8333333],[79.7083334,22.1666666],[79.7083334,37.5],[79.7083334,46.8333333],[80.2916667,46.8333333],[80.2916667,37.5],[80.2916667,22.1666666],[80.2916667,12.8333333],[80.5,12.8333333],[80.5,1.25],[80.78125,-5.8333334]],"sourceHandles":["1ED8D","1ED92","1ED95","1ED96","1F28A","1F28B","1F292","1F293","1F2AA","1F2AB","1F2B1","1F2B2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":306,"id":"upper-exterior-1-south-column-306","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":305,"columnIndex":54,"outlineFt":[[82.5520834,-5.8333334],[82.8333334,1.25],[82.8333334,12.8333333],[82.8333334,22.1666666],[82.6458334,22.1666666],[82.6458334,37.5],[82.8333334,37.5],[82.8333334,46.8333333],[83.8333334,46.8333333],[83.8333334,37.5],[84.0208334,37.5],[84.0208334,22.1666666],[83.8333334,22.1666666],[83.8333334,12.8333333],[83.8333334,1.25],[84.1145834,-5.8333334]],"sourceHandles":["1ED93","1ED98","1ED9B","1ED9C","1F2BE","1F2BF","1F2C4","1F2C5","1F2C6","1F2C7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":305,"id":"upper-exterior-1-south-column-305","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":304,"columnIndex":55,"outlineFt":[[85.8854167,-5.8333334],[86.1666667,1.25],[86.1666667,12.8333333],[86.375,12.8333333],[86.375,22.1666666],[86.375,37.5],[86.375,46.8333333],[86.9583334,46.8333333],[86.9583334,37.5],[86.9583334,22.1666666],[86.9583334,12.8333333],[87.1666667,12.8333333],[87.1666667,1.25],[87.4479167,-5.8333334]],"sourceHandles":["1ED99","1ED9E","1EDA1","1EDA2","1F2BA","1F2BB","1F2C2","1F2C3","1F2DA","1F2DB","1F2E1","1F2E2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":304,"id":"upper-exterior-1-south-column-304","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":303,"columnIndex":56,"outlineFt":[[89.21875,-5.8333334],[89.5,1.25],[89.5,12.8333333],[89.5,22.1666666],[89.3125,22.1666666],[89.3125,37.5],[89.5,37.5],[89.5,46.8333333],[90.5,46.8333333],[90.5,37.5],[90.6875,37.5],[90.6875,22.1666666],[90.5,22.1666666],[90.5,12.8333333],[90.5,1.25],[90.78125,-5.8333334]],"sourceHandles":["1ED9F","1EDA4","1EDA7","1EDA8","1F2EE","1F2EF","1F2F4","1F2F5","1F2F6","1F2F7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":303,"id":"upper-exterior-1-south-column-303","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":302,"columnIndex":57,"outlineFt":[[92.5520834,-5.8333334],[92.8333334,1.25],[92.8333334,12.8333333],[93.0416667,12.8333333],[93.0416667,22.1666666],[93.0416667,37.5],[93.0416667,46.8333333],[93.625,46.8333333],[93.625,37.5],[93.625,22.1666666],[93.625,12.8333333],[93.8333334,12.8333333],[93.8333334,1.25],[94.1145834,-5.8333334]],"sourceHandles":["1EDA5","1EDAA","1EDAC","1EDAD","1F2EA","1F2EB","1F2F2","1F2F3","1F30A","1F30B","1F311","1F312"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":302,"id":"upper-exterior-1-south-column-302","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":301,"columnIndex":58,"outlineFt":[[95.8854167,-5.8333334],[96.1170343,-0.0],[96.1666667,1.25],[96.1668614,1.25],[96.1668614,17.5],[96.1668614,17.5049035],[96.1668614,22.1666666],[95.9791667,22.1666666],[95.9791667,37.5],[96.1668614,37.5],[96.1668614,49.0833333],[98.375,49.0833333],[98.375,37.5],[98.375,22.1666666],[98.375,17.5049035],[98.375,17.5],[98.375,1.25],[98.375,-0.0],[98.375,-5.8333334]],"sourceHandles":["1EDAE","1EDAF","1EDB0","1EDB2","1EDB4","1EDB5","1EDB6","1F320","1F322"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":301,"id":"upper-exterior-1-south-column-301","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[-93.8333333,1.25],[-94.1145833,-5.8333334],[-95.8854166,-5.8333334],[-96.1170343,-0.0],[-96.1666666,1.25]],"sourceHandles":["1EC49","1EC4A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-0","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[-90.5,1.25],[-90.78125,-5.8333334],[-92.5520833,-5.8333334],[-92.8333333,1.25]],"sourceHandles":["1EC48","1EC4E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-1","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[-87.1666666,1.25],[-87.4479166,-5.8333334],[-89.21875,-5.8333334],[-89.5,1.25]],"sourceHandles":["1EC5F","1EC62"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-2","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[-83.8333333,1.25],[-84.1145833,-5.8333334],[-85.8854166,-5.8333334],[-86.1666666,1.25]],"sourceHandles":["1EC65","1EC68"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-3","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[-80.5,1.25],[-80.78125,-5.8333334],[-82.5520833,-5.8333334],[-82.8333333,1.25]],"sourceHandles":["1EC6B","1EC6E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-4","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[-77.1666666,1.25],[-77.4479166,-5.8333334],[-79.21875,-5.8333334],[-79.5,1.25]],"sourceHandles":["1EC71","1EC74"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-5","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[-73.8333333,1.25],[-74.1145833,-5.8333334],[-75.8854166,-5.8333334],[-76.1666666,1.25]],"sourceHandles":["1EC77","1EC7A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-6","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[-70.5,1.25],[-70.78125,-5.8333334],[-72.5520833,-5.8333334],[-72.8333333,1.25]],"sourceHandles":["1EC7D","1EC80"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-7","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[-67.1666666,1.25],[-67.4479166,-5.8333334],[-69.21875,-5.8333334],[-69.5,1.25]],"sourceHandles":["1EC83","1EC86"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-8","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[-63.8333333,1.25],[-64.1145833,-5.8333334],[-65.8854166,-5.8333334],[-66.1666666,1.25]],"sourceHandles":["1EC89","1EC8C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-9","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[-60.5,1.25],[-60.78125,-5.8333334],[-62.5520833,-5.8333334],[-62.8333333,1.25]],"sourceHandles":["1EC8F","1EC92"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-10","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[-57.1666666,1.25],[-57.4479166,-5.8333334],[-59.21875,-5.8333334],[-59.5,1.25]],"sourceHandles":["1EC95","1EC98"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-11","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[-53.8333333,1.25],[-54.1145833,-5.8333334],[-55.8854166,-5.8333334],[-56.1666666,1.25]],"sourceHandles":["1EC9B","1EC9E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-12","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[-50.5,1.25],[-50.78125,-5.8333334],[-52.5520833,-5.8333334],[-52.8333333,1.25]],"sourceHandles":["1ECA1","1ECA4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-13","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[-47.1666666,1.25],[-47.4479166,-5.8333334],[-49.21875,-5.8333334],[-49.5,1.25]],"sourceHandles":["1ECA7","1ECAA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-14","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[-43.8333333,1.25],[-44.1145833,-5.8333334],[-45.8854166,-5.8333334],[-46.1666666,1.25]],"sourceHandles":["1ECAD","1ECB0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-15","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[-40.5,1.25],[-40.78125,-5.8333334],[-42.5520833,-5.8333334],[-42.8333333,1.25]],"sourceHandles":["1ECB3","1ECB6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-16","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[-37.1666666,1.25],[-37.4479166,-5.8333334],[-39.21875,-5.8333334],[-39.5,1.25]],"sourceHandles":["1ECB9","1ECBC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-17","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[-33.8333333,1.25],[-34.1145833,-5.8333334],[-35.8854166,-5.8333334],[-36.1666666,1.25]],"sourceHandles":["1ECBF","1ECC2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-18","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[-30.5,1.25],[-30.78125,-5.8333334],[-32.5520833,-5.8333334],[-32.8333333,1.25]],"sourceHandles":["1ECC5","1ECC8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-19","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[-27.1666666,1.25],[-27.4479166,-5.8333334],[-29.21875,-5.8333334],[-29.5,1.25]],"sourceHandles":["1ECCB","1ECCE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-20","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[-23.8333333,1.25],[-24.1145833,-5.8333334],[-25.8854166,-5.8333334],[-26.1666666,1.25]],"sourceHandles":["1ECD1","1ECD4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-21","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[-20.5,1.25],[-20.78125,-5.8333334],[-22.5520833,-5.8333334],[-22.8333333,1.25]],"sourceHandles":["1ECD7","1ECDA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-22","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[-17.1666666,1.25],[-17.4479166,-5.8333334],[-19.21875,-5.8333334],[-19.5,1.25]],"sourceHandles":["1ECDD","1ECE0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-23","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[-13.8333333,1.25],[-14.1145833,-5.8333334],[-15.8854166,-5.8333334],[-16.1666666,1.25]],"sourceHandles":["1ECE3","1ECE6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-24","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[-10.5,1.25],[-10.78125,-5.8333334],[-12.5520833,-5.8333334],[-12.8333333,1.25]],"sourceHandles":["1ECE9","1ECEC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-25","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[-7.1666666,1.25],[-7.4479166,-5.8333334],[-9.21875,-5.8333334],[-9.5,1.25]],"sourceHandles":["1ECEF","1ECF2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-26","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[-3.8333333,1.25],[-4.1145833,-5.8333334],[-5.8854166,-5.8333334],[-6.1666666,1.25]],"sourceHandles":["1ECF5","1ECF8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-27","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[-0.5,1.25],[-0.78125,-5.8333334],[-2.5520833,-5.8333334],[-2.8333333,1.25]],"sourceHandles":["1ECFB","1ECFE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-28","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[2.8333334,1.25],[2.5520834,-5.8333334],[0.78125,-5.8333334],[0.5,1.25]],"sourceHandles":["1ED01","1ED04"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-29","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[6.1666667,1.25],[5.8854167,-5.8333334],[4.1145834,-5.8333334],[3.8333334,1.25]],"sourceHandles":["1ED07","1ED0A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-30","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[9.5,1.25],[9.21875,-5.8333334],[7.4479167,-5.8333334],[7.1666667,1.25]],"sourceHandles":["1ED0D","1ED10"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-31","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[12.8333334,1.25],[12.5520834,-5.8333334],[10.78125,-5.8333334],[10.5,1.25]],"sourceHandles":["1ED13","1ED16"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-32","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[16.1666667,1.25],[15.8854167,-5.8333334],[14.1145834,-5.8333334],[13.8333334,1.25]],"sourceHandles":["1ED19","1ED1C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-33","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[19.5,1.25],[19.21875,-5.8333334],[17.4479167,-5.8333334],[17.1666667,1.25]],"sourceHandles":["1ED1F","1ED22"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-34","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[22.8333334,1.25],[22.5520834,-5.8333334],[20.78125,-5.8333334],[20.5,1.25]],"sourceHandles":["1ED25","1ED28"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-35","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[26.1666667,1.25],[25.8854167,-5.8333334],[24.1145834,-5.8333334],[23.8333334,1.25]],"sourceHandles":["1ED2B","1ED2E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-36","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[29.5,1.25],[29.21875,-5.8333334],[27.4479167,-5.8333334],[27.1666667,1.25]],"sourceHandles":["1ED31","1ED34"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-37","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[32.8333334,1.25],[32.5520834,-5.8333334],[30.78125,-5.8333334],[30.5,1.25]],"sourceHandles":["1ED37","1ED3A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-38","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[36.1666667,1.25],[35.8854167,-5.8333334],[34.1145834,-5.8333334],[33.8333334,1.25]],"sourceHandles":["1ED3D","1ED40"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-39","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[39.5,1.25],[39.21875,-5.8333334],[37.4479167,-5.8333334],[37.1666667,1.25]],"sourceHandles":["1ED43","1ED46"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-40","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[42.8333334,1.25],[42.5520834,-5.8333334],[40.78125,-5.8333334],[40.5,1.25]],"sourceHandles":["1ED49","1ED4C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-41","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[46.1666667,1.25],[45.8854167,-5.8333334],[44.1145834,-5.8333334],[43.8333334,1.25]],"sourceHandles":["1ED4F","1ED52"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-42","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[49.5,1.25],[49.21875,-5.8333334],[47.4479167,-5.8333334],[47.1666667,1.25]],"sourceHandles":["1ED55","1ED58"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-43","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[52.8333334,1.25],[52.5520834,-5.8333334],[50.78125,-5.8333334],[50.5,1.25]],"sourceHandles":["1ED5B","1ED5E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-44","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[56.1666667,1.25],[55.8854167,-5.8333334],[54.1145834,-5.8333334],[53.8333334,1.25]],"sourceHandles":["1ED61","1ED64"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-45","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[59.5,1.25],[59.21875,-5.8333334],[57.4479167,-5.8333334],[57.1666667,1.25]],"sourceHandles":["1ED67","1ED6A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-46","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[62.8333334,1.25],[62.5520834,-5.8333334],[60.78125,-5.8333334],[60.5,1.25]],"sourceHandles":["1ED6D","1ED70"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-47","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[66.1666667,1.25],[65.8854167,-5.8333334],[64.1145834,-5.8333334],[63.8333334,1.25]],"sourceHandles":["1ED73","1ED76"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-48","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[69.5,1.25],[69.21875,-5.8333334],[67.4479167,-5.8333334],[67.1666667,1.25]],"sourceHandles":["1ED79","1ED7C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-49","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[72.8333334,1.25],[72.5520834,-5.8333334],[70.78125,-5.8333334],[70.5,1.25]],"sourceHandles":["1ED7F","1ED82"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-50","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[76.1666667,1.25],[75.8854167,-5.8333334],[74.1145834,-5.8333334],[73.8333334,1.25]],"sourceHandles":["1ED85","1ED88"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-51","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[79.5,1.25],[79.21875,-5.8333334],[77.4479167,-5.8333334],[77.1666667,1.25]],"sourceHandles":["1ED8B","1ED8E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-52","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[82.8333334,1.25],[82.5520834,-5.8333334],[80.78125,-5.8333334],[80.5,1.25]],"sourceHandles":["1ED91","1ED94"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-53","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[86.1666667,1.25],[85.8854167,-5.8333334],[84.1145834,-5.8333334],[83.8333334,1.25]],"sourceHandles":["1ED97","1ED9A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-54","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[89.5,1.25],[89.21875,-5.8333334],[87.4479167,-5.8333334],[87.1666667,1.25]],"sourceHandles":["1ED9D","1EDA0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-55","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[92.8333334,1.25],[92.5520834,-5.8333334],[90.78125,-5.8333334],[90.5,1.25]],"sourceHandles":["1EDA3","1EDA6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-56","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[96.1666667,1.25],[96.1170343,-0.0],[95.8854167,-5.8333334],[94.1145834,-5.8333334],[93.8333334,1.25]],"sourceHandles":["1EDA9","1EDAB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-107-57","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[-93.625,18.8333333],[-93.625,12.8333333],[-93.8333333,12.8333333],[-96.1666666,12.8333333],[-96.1666666,17.5],[-96.1666666,18.8333333]],"sourceHandles":["1EDBF","1EDC0","1EDDD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-0","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[-90.5,18.8333333],[-90.5,12.8333333],[-92.8333333,12.8333333],[-93.0416666,12.8333333],[-93.0416666,18.8333333]],"sourceHandles":["1EDDB","1EDDC","1EDDF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-1","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[-86.9583333,18.8333333],[-86.9583333,12.8333333],[-87.1666666,12.8333333],[-89.5,12.8333333],[-89.5,18.8333333]],"sourceHandles":["1EDD9","1EDDA","1EDE0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-2","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[-83.8333333,18.8333333],[-83.8333333,12.8333333],[-86.1666666,12.8333333],[-86.375,12.8333333],[-86.375,18.8333333]],"sourceHandles":["1EE20","1EE21","1EE22"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-3","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[-80.2916666,18.8333333],[-80.2916666,12.8333333],[-80.5,12.8333333],[-82.8333333,12.8333333],[-82.8333333,18.8333333]],"sourceHandles":["1EE1E","1EE1F","1EE23"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-4","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[-77.1666666,18.8333333],[-77.1666666,12.8333333],[-79.5,12.8333333],[-79.7083333,12.8333333],[-79.7083333,18.8333333]],"sourceHandles":["1EE50","1EE51","1EE52"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-5","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[-73.625,18.8333333],[-73.625,12.8333333],[-73.8333333,12.8333333],[-76.1666666,12.8333333],[-76.1666666,18.8333333]],"sourceHandles":["1EE4E","1EE4F","1EE53"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-6","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[-70.5,18.8333333],[-70.5,12.8333333],[-72.8333333,12.8333333],[-73.0416666,12.8333333],[-73.0416666,18.8333333]],"sourceHandles":["1EE80","1EE81","1EE82"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-7","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[-66.9583333,18.8333333],[-66.9583333,12.8333333],[-67.1666666,12.8333333],[-69.5,12.8333333],[-69.5,18.8333333]],"sourceHandles":["1EE7E","1EE7F","1EE83"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-8","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[-63.8333333,18.8333333],[-63.8333333,12.8333333],[-66.1666666,12.8333333],[-66.375,12.8333333],[-66.375,18.8333333]],"sourceHandles":["1EEB0","1EEB1","1EEB2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-9","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[-60.2916666,18.8333333],[-60.2916666,12.8333333],[-60.5,12.8333333],[-62.8333333,12.8333333],[-62.8333333,18.8333333]],"sourceHandles":["1EEAE","1EEAF","1EEB3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-10","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[-57.1666666,18.8333333],[-57.1666666,12.8333333],[-59.5,12.8333333],[-59.7083333,12.8333333],[-59.7083333,18.8333333]],"sourceHandles":["1EEE0","1EEE1","1EEE2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-11","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[-53.625,18.8333333],[-53.625,12.8333333],[-53.8333333,12.8333333],[-56.1666666,12.8333333],[-56.1666666,18.8333333]],"sourceHandles":["1EEDE","1EEDF","1EEE3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-12","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[-50.5,18.8333333],[-50.5,12.8333333],[-52.8333333,12.8333333],[-53.0416666,12.8333333],[-53.0416666,18.8333333]],"sourceHandles":["1EF10","1EF11","1EF12"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-13","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[-46.9583333,18.8333333],[-46.9583333,12.8333333],[-47.1666666,12.8333333],[-49.5,12.8333333],[-49.5,18.8333333]],"sourceHandles":["1EF0E","1EF0F","1EF13"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-14","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[-43.8333333,18.8333333],[-43.8333333,12.8333333],[-46.1666666,12.8333333],[-46.375,12.8333333],[-46.375,18.8333333]],"sourceHandles":["1EF40","1EF41","1EF42"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-15","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[-40.2916666,18.8333333],[-40.2916666,12.8333333],[-40.5,12.8333333],[-42.8333333,12.8333333],[-42.8333333,18.8333333]],"sourceHandles":["1EF3E","1EF3F","1EF43"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-16","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[-37.1666666,18.8333333],[-37.1666666,12.8333333],[-39.5,12.8333333],[-39.7083333,12.8333333],[-39.7083333,18.8333333]],"sourceHandles":["1EF70","1EF71","1EF72"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-17","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[-33.625,18.8333333],[-33.625,12.8333333],[-33.8333333,12.8333333],[-36.1666666,12.8333333],[-36.1666666,18.8333333]],"sourceHandles":["1EF6E","1EF6F","1EF73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-18","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[-30.5,18.8333333],[-30.5,12.8333333],[-32.8333333,12.8333333],[-33.0416666,12.8333333],[-33.0416666,18.8333333]],"sourceHandles":["1EFA0","1EFA1","1EFA2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-19","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[-26.9583333,18.8333333],[-26.9583333,12.8333333],[-27.1666666,12.8333333],[-29.5,12.8333333],[-29.5,18.8333333]],"sourceHandles":["1EF9E","1EF9F","1EFA3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-20","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[-23.8333333,18.8333333],[-23.8333333,12.8333333],[-26.1666666,12.8333333],[-26.375,12.8333333],[-26.375,18.8333333]],"sourceHandles":["1EFD0","1EFD1","1EFD2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-21","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[-20.2916666,18.8333333],[-20.2916666,12.8333333],[-20.5,12.8333333],[-22.8333333,12.8333333],[-22.8333333,18.8333333]],"sourceHandles":["1EFCE","1EFCF","1EFD3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-22","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[-17.1666666,18.8333333],[-17.1666666,12.8333333],[-19.5,12.8333333],[-19.7083333,12.8333333],[-19.7083333,18.8333333]],"sourceHandles":["1F000","1F001","1F002"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-23","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[-13.625,18.8333333],[-13.625,12.8333333],[-13.8333333,12.8333333],[-16.1666666,12.8333333],[-16.1666666,18.8333333]],"sourceHandles":["1EFFE","1EFFF","1F003"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-24","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[-10.5,18.8333333],[-10.5,12.8333333],[-12.8333333,12.8333333],[-13.0416666,12.8333333],[-13.0416666,18.8333333]],"sourceHandles":["1F030","1F031","1F032"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-25","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[-6.9583333,18.8333333],[-6.9583333,12.8333333],[-7.1666666,12.8333333],[-9.5,12.8333333],[-9.5,18.8333333]],"sourceHandles":["1F02E","1F02F","1F033"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-26","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[-3.8333333,18.8333333],[-3.8333333,12.8333333],[-6.1666666,12.8333333],[-6.375,12.8333333],[-6.375,18.8333333]],"sourceHandles":["1F060","1F061","1F062"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-27","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[-0.2916666,18.8333333],[-0.2916666,12.8333333],[-0.5,12.8333333],[-2.8333333,12.8333333],[-2.8333333,18.8333333]],"sourceHandles":["1F05E","1F05F","1F063"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-28","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[2.8333334,18.8333333],[2.8333334,12.8333333],[0.5,12.8333333],[0.2916667,12.8333333],[0.2916667,18.8333333]],"sourceHandles":["1F090","1F091","1F092"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-29","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[6.375,18.8333333],[6.375,12.8333333],[6.1666667,12.8333333],[3.8333334,12.8333333],[3.8333334,18.8333333]],"sourceHandles":["1F08E","1F08F","1F093"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-30","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[9.5,18.8333333],[9.5,12.8333333],[7.1666667,12.8333333],[6.9583334,12.8333333],[6.9583334,18.8333333]],"sourceHandles":["1F0C0","1F0C1","1F0C2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-31","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[13.0416667,18.8333333],[13.0416667,12.8333333],[12.8333334,12.8333333],[10.5,12.8333333],[10.5,18.8333333]],"sourceHandles":["1F0BE","1F0BF","1F0C3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-32","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[16.1666667,18.8333333],[16.1666667,12.8333333],[13.8333334,12.8333333],[13.625,12.8333333],[13.625,18.8333333]],"sourceHandles":["1F0F0","1F0F1","1F0F2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-33","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[19.7083334,18.8333333],[19.7083334,12.8333333],[19.5,12.8333333],[17.1666667,12.8333333],[17.1666667,18.8333333]],"sourceHandles":["1F0EE","1F0EF","1F0F3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-34","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[22.8333334,18.8333333],[22.8333334,12.8333333],[20.5,12.8333333],[20.2916667,12.8333333],[20.2916667,18.8333333]],"sourceHandles":["1F120","1F121","1F122"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-35","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[26.375,18.8333333],[26.375,12.8333333],[26.1666667,12.8333333],[23.8333334,12.8333333],[23.8333334,18.8333333]],"sourceHandles":["1F11E","1F11F","1F123"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-36","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[29.5,18.8333333],[29.5,12.8333333],[27.1666667,12.8333333],[26.9583334,12.8333333],[26.9583334,18.8333333]],"sourceHandles":["1F150","1F151","1F152"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-37","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[33.0416667,18.8333333],[33.0416667,12.8333333],[32.8333334,12.8333333],[30.5,12.8333333],[30.5,18.8333333]],"sourceHandles":["1F14E","1F14F","1F153"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-38","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[36.1666667,18.8333333],[36.1666667,12.8333333],[33.8333334,12.8333333],[33.625,12.8333333],[33.625,18.8333333]],"sourceHandles":["1F180","1F181","1F182"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-39","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[39.7083334,18.8333333],[39.7083334,12.8333333],[39.5,12.8333333],[37.1666667,12.8333333],[37.1666667,18.8333333]],"sourceHandles":["1F17E","1F17F","1F183"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-40","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[42.8333334,18.8333333],[42.8333334,12.8333333],[40.5,12.8333333],[40.2916667,12.8333333],[40.2916667,18.8333333]],"sourceHandles":["1F1B0","1F1B1","1F1B2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-41","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[46.375,18.8333333],[46.375,12.8333333],[46.1666667,12.8333333],[43.8333334,12.8333333],[43.8333334,18.8333333]],"sourceHandles":["1F1AE","1F1AF","1F1B3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-42","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[49.5,18.8333333],[49.5,12.8333333],[47.1666667,12.8333333],[46.9583334,12.8333333],[46.9583334,18.8333333]],"sourceHandles":["1F1E0","1F1E1","1F1E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-43","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[53.0416667,18.8333333],[53.0416667,12.8333333],[52.8333334,12.8333333],[50.5,12.8333333],[50.5,18.8333333]],"sourceHandles":["1F1DE","1F1DF","1F1E3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-44","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[56.1666667,18.8333333],[56.1666667,12.8333333],[53.8333334,12.8333333],[53.625,12.8333333],[53.625,18.8333333]],"sourceHandles":["1F210","1F211","1F212"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-45","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[59.7083334,18.8333333],[59.7083334,12.8333333],[59.5,12.8333333],[57.1666667,12.8333333],[57.1666667,18.8333333]],"sourceHandles":["1F20E","1F20F","1F213"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-46","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[62.8333334,18.8333333],[62.8333334,12.8333333],[60.5,12.8333333],[60.2916667,12.8333333],[60.2916667,18.8333333]],"sourceHandles":["1F240","1F241","1F242"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-47","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[66.375,18.8333333],[66.375,12.8333333],[66.1666667,12.8333333],[63.8333334,12.8333333],[63.8333334,18.8333333]],"sourceHandles":["1F23E","1F23F","1F243"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-48","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[69.5,18.8333333],[69.5,12.8333333],[67.1666667,12.8333333],[66.9583334,12.8333333],[66.9583334,18.8333333]],"sourceHandles":["1F270","1F271","1F272"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-49","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[73.0416667,18.8333333],[73.0416667,12.8333333],[72.8333334,12.8333333],[70.5,12.8333333],[70.5,18.8333333]],"sourceHandles":["1F26E","1F26F","1F273"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-50","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[76.1666667,18.8333333],[76.1666667,12.8333333],[73.8333334,12.8333333],[73.625,12.8333333],[73.625,18.8333333]],"sourceHandles":["1F2A0","1F2A1","1F2A2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-51","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[79.7083334,18.8333333],[79.7083334,12.8333333],[79.5,12.8333333],[77.1666667,12.8333333],[77.1666667,18.8333333]],"sourceHandles":["1F29E","1F29F","1F2A3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-52","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[82.8333334,18.8333333],[82.8333334,12.8333333],[80.5,12.8333333],[80.2916667,12.8333333],[80.2916667,18.8333333]],"sourceHandles":["1F2D0","1F2D1","1F2D2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-53","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[86.375,18.8333333],[86.375,12.8333333],[86.1666667,12.8333333],[83.8333334,12.8333333],[83.8333334,18.8333333]],"sourceHandles":["1F2CE","1F2CF","1F2D3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-54","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[89.5,18.8333333],[89.5,12.8333333],[87.1666667,12.8333333],[86.9583334,12.8333333],[86.9583334,18.8333333]],"sourceHandles":["1F300","1F301","1F302"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-55","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[93.0416667,18.8333333],[93.0416667,12.8333333],[92.8333334,12.8333333],[90.5,12.8333333],[90.5,18.8333333]],"sourceHandles":["1F2FE","1F2FF","1F303"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-56","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[96.1668614,18.8333333],[96.1668614,17.5049035],[96.1668614,17.5],[96.1668614,12.8333333],[93.8333334,12.8333333],[93.625,12.8333333],[93.625,18.8333333]],"sourceHandles":["1F325","1F326","1F327"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-108-57","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[-93.625,46.8333333],[-93.625,39.5833333],[-96.1666666,39.5833333],[-96.1666666,46.8333333]],"sourceHandles":["1EDE1","1EDEF","1F399"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-0","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[-90.5,46.8333333],[-90.5,39.5833333],[-93.0416666,39.5833333],[-93.0416666,46.8333333]],"sourceHandles":["1EDE9","1EDF0","1EDF1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-1","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[-86.9583333,46.8333333],[-86.9583333,39.5833333],[-89.5,39.5833333],[-89.5,46.8333333]],"sourceHandles":["1EDEA","1EDF2","1EDF3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-2","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[-83.8333333,46.8333333],[-83.8333333,39.5833333],[-86.375,39.5833333],[-86.375,46.8333333]],"sourceHandles":["1EDF4","1EE28","1F32C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-3","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[-80.2916666,46.8333333],[-80.2916666,39.5833333],[-82.8333333,39.5833333],[-82.8333333,46.8333333]],"sourceHandles":["1EE29","1F32D","1F32E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-4","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[-77.1666666,46.8333333],[-77.1666666,39.5833333],[-79.7083333,39.5833333],[-79.7083333,46.8333333]],"sourceHandles":["1EE58","1F32F","1F330"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-5","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[-73.625,46.8333333],[-73.625,39.5833333],[-76.1666666,39.5833333],[-76.1666666,46.8333333]],"sourceHandles":["1EE59","1F331","1F332"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-6","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[-70.5,46.8333333],[-70.5,39.5833333],[-73.0416666,39.5833333],[-73.0416666,46.8333333]],"sourceHandles":["1EE88","1F333","1F334"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-7","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[-66.9583333,46.8333333],[-66.9583333,39.5833333],[-69.5,39.5833333],[-69.5,46.8333333]],"sourceHandles":["1EE89","1F335","1F336"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-8","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[-63.8333333,46.8333333],[-63.8333333,39.5833333],[-66.375,39.5833333],[-66.375,46.8333333]],"sourceHandles":["1EEB8","1F337","1F338"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-9","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[-60.2916666,46.8333333],[-60.2916666,39.5833333],[-62.8333333,39.5833333],[-62.8333333,46.8333333]],"sourceHandles":["1EEB9","1F339","1F33A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-10","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[-57.1666666,46.8333333],[-57.1666666,39.5833333],[-59.7083333,39.5833333],[-59.7083333,46.8333333]],"sourceHandles":["1EEE8","1F33B","1F33C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-11","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[-53.625,46.8333333],[-53.625,39.5833333],[-56.1666666,39.5833333],[-56.1666666,46.8333333]],"sourceHandles":["1EEE9","1F33D","1F33E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-12","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[-50.5,46.8333333],[-50.5,39.5833333],[-53.0416666,39.5833333],[-53.0416666,46.8333333]],"sourceHandles":["1EF18","1F33F","1F340"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-13","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[-46.9583333,46.8333333],[-46.9583333,39.5833333],[-49.5,39.5833333],[-49.5,46.8333333]],"sourceHandles":["1EF19","1F341","1F342"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-14","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[-43.8333333,46.8333333],[-43.8333333,39.5833333],[-46.375,39.5833333],[-46.375,46.8333333]],"sourceHandles":["1EF48","1F343","1F344"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-15","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[-40.2916666,46.8333333],[-40.2916666,39.5833333],[-42.8333333,39.5833333],[-42.8333333,46.8333333]],"sourceHandles":["1EF49","1F345","1F346"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-16","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[-37.1666666,46.8333333],[-37.1666666,39.5833333],[-39.7083333,39.5833333],[-39.7083333,46.8333333]],"sourceHandles":["1EF78","1F347","1F348"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-17","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[-33.625,46.8333333],[-33.625,39.5833333],[-36.1666666,39.5833333],[-36.1666666,46.8333333]],"sourceHandles":["1EF79","1F349","1F34A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-18","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[-30.5,46.8333333],[-30.5,39.5833333],[-33.0416666,39.5833333],[-33.0416666,46.8333333]],"sourceHandles":["1EFA8","1F34B","1F34C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-19","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[-26.9583333,46.8333333],[-26.9583333,39.5833333],[-29.5,39.5833333],[-29.5,46.8333333]],"sourceHandles":["1EFA9","1F34D","1F34E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-20","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[-23.8333333,46.8333333],[-23.8333333,39.5833333],[-26.375,39.5833333],[-26.375,46.8333333]],"sourceHandles":["1EFD8","1F34F","1F350"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-21","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[-20.2916666,46.8333333],[-20.2916666,39.5833333],[-22.8333333,39.5833333],[-22.8333333,46.8333333]],"sourceHandles":["1EFD9","1F351","1F352"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-22","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[-17.1666666,46.8333333],[-17.1666666,39.5833333],[-19.7083333,39.5833333],[-19.7083333,46.8333333]],"sourceHandles":["1F008","1F353","1F354"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-23","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[-13.625,46.8333333],[-13.625,39.5833333],[-16.1666666,39.5833333],[-16.1666666,46.8333333]],"sourceHandles":["1F009","1F355","1F356"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-24","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[-10.5,46.8333333],[-10.5,39.5833333],[-13.0416666,39.5833333],[-13.0416666,46.8333333]],"sourceHandles":["1F038","1F357","1F358"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-25","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[-6.9583333,46.8333333],[-6.9583333,39.5833333],[-9.5,39.5833333],[-9.5,46.8333333]],"sourceHandles":["1F039","1F359","1F35A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-26","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[-3.8333333,46.8333333],[-3.8333333,39.5833333],[-6.375,39.5833333],[-6.375,46.8333333]],"sourceHandles":["1F068","1F35B","1F35C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-27","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[-0.2916666,46.8333333],[-0.2916666,39.5833333],[-2.8333333,39.5833333],[-2.8333333,46.8333333]],"sourceHandles":["1F069","1F35D","1F35E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-28","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[2.8333334,46.8333333],[2.8333334,39.5833333],[0.2916667,39.5833333],[0.2916667,46.8333333]],"sourceHandles":["1F098","1F35F","1F360"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-29","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[6.375,46.8333333],[6.375,39.5833333],[3.8333334,39.5833333],[3.8333334,46.8333333]],"sourceHandles":["1F099","1F361","1F362"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-30","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[9.5,46.8333333],[9.5,39.5833333],[6.9583334,39.5833333],[6.9583334,46.8333333]],"sourceHandles":["1F0C8","1F363","1F364"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-31","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[13.0416667,46.8333333],[13.0416667,39.5833333],[10.5,39.5833333],[10.5,46.8333333]],"sourceHandles":["1F0C9","1F365","1F366"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-32","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[16.1666667,46.8333333],[16.1666667,39.5833333],[13.625,39.5833333],[13.625,46.8333333]],"sourceHandles":["1F0F8","1F367","1F368"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-33","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[19.7083334,46.8333333],[19.7083334,39.5833333],[17.1666667,39.5833333],[17.1666667,46.8333333]],"sourceHandles":["1F0F9","1F369","1F36A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-34","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[22.8333334,46.8333333],[22.8333334,39.5833333],[20.2916667,39.5833333],[20.2916667,46.8333333]],"sourceHandles":["1F128","1F36B","1F36C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-35","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[26.375,46.8333333],[26.375,39.5833333],[23.8333334,39.5833333],[23.8333334,46.8333333]],"sourceHandles":["1F129","1F36D","1F36E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-36","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[29.5,46.8333333],[29.5,39.5833333],[26.9583334,39.5833333],[26.9583334,46.8333333]],"sourceHandles":["1F158","1F36F","1F370"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-37","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[33.0416667,46.8333333],[33.0416667,39.5833333],[30.5,39.5833333],[30.5,46.8333333]],"sourceHandles":["1F159","1F371","1F372"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-38","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[36.1666667,46.8333333],[36.1666667,39.5833333],[33.625,39.5833333],[33.625,46.8333333]],"sourceHandles":["1F188","1F373","1F374"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-39","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[39.7083334,46.8333333],[39.7083334,39.5833333],[37.1666667,39.5833333],[37.1666667,46.8333333]],"sourceHandles":["1F189","1F375","1F376"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-40","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[42.8333334,46.8333333],[42.8333334,39.5833333],[40.2916667,39.5833333],[40.2916667,46.8333333]],"sourceHandles":["1F1B8","1F377","1F378"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-41","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[46.375,46.8333333],[46.375,39.5833333],[43.8333334,39.5833333],[43.8333334,46.8333333]],"sourceHandles":["1F1B9","1F379","1F37A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-42","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[49.5,46.8333333],[49.5,39.5833333],[46.9583334,39.5833333],[46.9583334,46.8333333]],"sourceHandles":["1F1E8","1F37B","1F37C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-43","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[53.0416667,46.8333333],[53.0416667,39.5833333],[50.5,39.5833333],[50.5,46.8333333]],"sourceHandles":["1F1E9","1F37D","1F37E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-44","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[56.1666667,46.8333333],[56.1666667,39.5833333],[53.625,39.5833333],[53.625,46.8333333]],"sourceHandles":["1F218","1F37F","1F380"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-45","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[59.7083334,46.8333333],[59.7083334,39.5833333],[57.1666667,39.5833333],[57.1666667,46.8333333]],"sourceHandles":["1F219","1F381","1F382"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-46","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[62.8333334,46.8333333],[62.8333334,39.5833333],[60.2916667,39.5833333],[60.2916667,46.8333333]],"sourceHandles":["1F248","1F383","1F384"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-47","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[66.375,46.8333333],[66.375,39.5833333],[63.8333334,39.5833333],[63.8333334,46.8333333]],"sourceHandles":["1F249","1F385","1F386"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-48","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[69.5,46.8333333],[69.5,39.5833333],[66.9583334,39.5833333],[66.9583334,46.8333333]],"sourceHandles":["1F278","1F387","1F388"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-49","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[73.0416667,46.8333333],[73.0416667,39.5833333],[70.5,39.5833333],[70.5,46.8333333]],"sourceHandles":["1F279","1F389","1F38A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-50","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[76.1666667,46.8333333],[76.1666667,39.5833333],[73.625,39.5833333],[73.625,46.8333333]],"sourceHandles":["1F2A8","1F38B","1F38C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-51","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[79.7083334,46.8333333],[79.7083334,39.5833333],[77.1666667,39.5833333],[77.1666667,46.8333333]],"sourceHandles":["1F2A9","1F38D","1F38E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-52","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[82.8333334,46.8333333],[82.8333334,39.5833333],[80.2916667,39.5833333],[80.2916667,46.8333333]],"sourceHandles":["1F2D8","1F38F","1F390"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-53","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[86.375,46.8333333],[86.375,39.5833333],[83.8333334,39.5833333],[83.8333334,46.8333333]],"sourceHandles":["1F2D9","1F391","1F392"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-54","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[89.5,46.8333333],[89.5,39.5833333],[86.9583334,39.5833333],[86.9583334,46.8333333]],"sourceHandles":["1F308","1F393","1F394"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-55","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[93.0416667,46.8333333],[93.0416667,39.5833333],[90.5,39.5833333],[90.5,46.8333333]],"sourceHandles":["1F309","1F395","1F396"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-56","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[96.1668614,46.8333333],[96.1668614,39.5833333],[93.625,39.5833333],[93.625,46.8333333]],"sourceHandles":["1F397","1F398"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-south-spandrel-110-57","tower":1,"face":"south","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":459,"columnIndex":0,"outlineFt":[[-98.375,-5.8333334],[-98.375,-0.0],[-98.375,1.25],[-98.375,17.5],[-98.375,22.1666666],[-98.375,37.5],[-98.375,49.0833333],[-96.1666666,49.0833333],[-96.1666666,37.5],[-95.9791666,37.5],[-95.9791666,22.1666666],[-96.1666666,22.1666666],[-96.1666666,17.5],[-96.1666666,1.25],[-96.1170343,-0.0],[-95.8854166,-5.8333334]],"sourceHandles":["1EC51","1EC53","1EC5A","1EC5B","1EC5E","1F31A","1F31B","1F31F"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":359,"id":"upper-exterior-2-south-column-459","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":458,"columnIndex":1,"outlineFt":[[-94.1145833,-5.8333334],[-93.8333333,1.25],[-93.8333333,12.8333333],[-93.625,12.8333333],[-93.625,22.1666666],[-93.625,37.5],[-93.625,46.8333333],[-93.0416666,46.8333333],[-93.0416666,37.5],[-93.0416666,22.1666666],[-93.0416666,12.8333333],[-92.8333333,12.8333333],[-92.8333333,1.25],[-92.5520833,-5.8333334]],"sourceHandles":["1EC4B","1EC4C","1EC4F","1EC50","1EDD3","1EDD4","1EDD7","1EDD8","1EDEB","1EDEC","1EE04","1EE05"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":358,"id":"upper-exterior-2-south-column-458","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":457,"columnIndex":2,"outlineFt":[[-90.78125,-5.8333334],[-90.5,1.25],[-90.5,12.8333333],[-90.5,22.1666666],[-90.6875,22.1666666],[-90.6875,37.5],[-90.5,37.5],[-90.5,46.8333333],[-89.5,46.8333333],[-89.5,37.5],[-89.3125,37.5],[-89.3125,22.1666666],[-89.5,22.1666666],[-89.5,12.8333333],[-89.5,1.25],[-89.21875,-5.8333334]],"sourceHandles":["1EC4D","1EC60","1EC63","1EC64","1EDC3","1EDC4","1EDC9","1EDCA","1EDCB","1EDCC"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":357,"id":"upper-exterior-2-south-column-457","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":456,"columnIndex":3,"outlineFt":[[-87.4479166,-5.8333334],[-87.1666666,1.25],[-87.1666666,12.8333333],[-86.9583333,12.8333333],[-86.9583333,22.1666666],[-86.9583333,37.5],[-86.9583333,46.8333333],[-86.375,46.8333333],[-86.375,37.5],[-86.375,22.1666666],[-86.375,12.8333333],[-86.1666666,12.8333333],[-86.1666666,1.25],[-85.8854166,-5.8333334]],"sourceHandles":["1EC61","1EC66","1EC69","1EC6A","1EDBD","1EDBE","1EDC7","1EDC8","1EDED","1EDEE","1EDFA","1EDFB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":356,"id":"upper-exterior-2-south-column-456","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":455,"columnIndex":4,"outlineFt":[[-84.1145833,-5.8333334],[-83.8333333,1.25],[-83.8333333,12.8333333],[-83.8333333,22.1666666],[-84.0208333,22.1666666],[-84.0208333,37.5],[-83.8333333,37.5],[-83.8333333,46.8333333],[-82.8333333,46.8333333],[-82.8333333,37.5],[-82.6458333,37.5],[-82.6458333,22.1666666],[-82.8333333,22.1666666],[-82.8333333,12.8333333],[-82.8333333,1.25],[-82.5520833,-5.8333334]],"sourceHandles":["1EC67","1EC6C","1EC6F","1EC70","1EE0E","1EE0F","1EE14","1EE15","1EE16","1EE17"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":355,"id":"upper-exterior-2-south-column-455","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":454,"columnIndex":5,"outlineFt":[[-80.78125,-5.8333334],[-80.5,1.25],[-80.5,12.8333333],[-80.2916666,12.8333333],[-80.2916666,22.1666666],[-80.2916666,37.5],[-80.2916666,46.8333333],[-79.7083333,46.8333333],[-79.7083333,37.5],[-79.7083333,22.1666666],[-79.7083333,12.8333333],[-79.5,12.8333333],[-79.5,1.25],[-79.21875,-5.8333334]],"sourceHandles":["1EC6D","1EC72","1EC75","1EC76","1EE0A","1EE0B","1EE12","1EE13","1EE2A","1EE2B","1EE31","1EE32"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":354,"id":"upper-exterior-2-south-column-454","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":453,"columnIndex":6,"outlineFt":[[-77.4479166,-5.8333334],[-77.1666666,1.25],[-77.1666666,12.8333333],[-77.1666666,22.1666666],[-77.3541666,22.1666666],[-77.3541666,37.5],[-77.1666666,37.5],[-77.1666666,46.8333333],[-76.1666666,46.8333333],[-76.1666666,37.5],[-75.9791666,37.5],[-75.9791666,22.1666666],[-76.1666666,22.1666666],[-76.1666666,12.8333333],[-76.1666666,1.25],[-75.8854166,-5.8333334]],"sourceHandles":["1EC73","1EC78","1EC7B","1EC7C","1EE3E","1EE3F","1EE44","1EE45","1EE46","1EE47"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":353,"id":"upper-exterior-2-south-column-453","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":452,"columnIndex":7,"outlineFt":[[-74.1145833,-5.8333334],[-73.8333333,1.25],[-73.8333333,12.8333333],[-73.625,12.8333333],[-73.625,22.1666666],[-73.625,37.5],[-73.625,46.8333333],[-73.0416666,46.8333333],[-73.0416666,37.5],[-73.0416666,22.1666666],[-73.0416666,12.8333333],[-72.8333333,12.8333333],[-72.8333333,1.25],[-72.5520833,-5.8333334]],"sourceHandles":["1EC79","1EC7E","1EC81","1EC82","1EE3A","1EE3B","1EE42","1EE43","1EE5A","1EE5B","1EE61","1EE62"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":352,"id":"upper-exterior-2-south-column-452","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":451,"columnIndex":8,"outlineFt":[[-70.78125,-5.8333334],[-70.5,1.25],[-70.5,12.8333333],[-70.5,22.1666666],[-70.6875,22.1666666],[-70.6875,37.5],[-70.5,37.5],[-70.5,46.8333333],[-69.5,46.8333333],[-69.5,37.5],[-69.3125,37.5],[-69.3125,22.1666666],[-69.5,22.1666666],[-69.5,12.8333333],[-69.5,1.25],[-69.21875,-5.8333334]],"sourceHandles":["1EC7F","1EC84","1EC87","1EC88","1EE6E","1EE6F","1EE74","1EE75","1EE76","1EE77"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":351,"id":"upper-exterior-2-south-column-451","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":450,"columnIndex":9,"outlineFt":[[-67.4479166,-5.8333334],[-67.1666666,1.25],[-67.1666666,12.8333333],[-66.9583333,12.8333333],[-66.9583333,22.1666666],[-66.9583333,37.5],[-66.9583333,46.8333333],[-66.375,46.8333333],[-66.375,37.5],[-66.375,22.1666666],[-66.375,12.8333333],[-66.1666666,12.8333333],[-66.1666666,1.25],[-65.8854166,-5.8333334]],"sourceHandles":["1EC85","1EC8A","1EC8D","1EC8E","1EE6A","1EE6B","1EE72","1EE73","1EE8A","1EE8B","1EE91","1EE92"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":350,"id":"upper-exterior-2-south-column-450","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":449,"columnIndex":10,"outlineFt":[[-64.1145833,-5.8333334],[-63.8333333,1.25],[-63.8333333,12.8333333],[-63.8333333,22.1666666],[-64.0208333,22.1666666],[-64.0208333,37.5],[-63.8333333,37.5],[-63.8333333,46.8333333],[-62.8333333,46.8333333],[-62.8333333,37.5],[-62.6458333,37.5],[-62.6458333,22.1666666],[-62.8333333,22.1666666],[-62.8333333,12.8333333],[-62.8333333,1.25],[-62.5520833,-5.8333334]],"sourceHandles":["1EC8B","1EC90","1EC93","1EC94","1EE9E","1EE9F","1EEA4","1EEA5","1EEA6","1EEA7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":349,"id":"upper-exterior-2-south-column-449","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":448,"columnIndex":11,"outlineFt":[[-60.78125,-5.8333334],[-60.5,1.25],[-60.5,12.8333333],[-60.2916666,12.8333333],[-60.2916666,22.1666666],[-60.2916666,37.5],[-60.2916666,46.8333333],[-59.7083333,46.8333333],[-59.7083333,37.5],[-59.7083333,22.1666666],[-59.7083333,12.8333333],[-59.5,12.8333333],[-59.5,1.25],[-59.21875,-5.8333334]],"sourceHandles":["1EC91","1EC96","1EC99","1EC9A","1EE9A","1EE9B","1EEA2","1EEA3","1EEBA","1EEBB","1EEC1","1EEC2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":348,"id":"upper-exterior-2-south-column-448","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":447,"columnIndex":12,"outlineFt":[[-57.4479166,-5.8333334],[-57.1666666,1.25],[-57.1666666,12.8333333],[-57.1666666,22.1666666],[-57.3541666,22.1666666],[-57.3541666,37.5],[-57.1666666,37.5],[-57.1666666,46.8333333],[-56.1666666,46.8333333],[-56.1666666,37.5],[-55.9791666,37.5],[-55.9791666,22.1666666],[-56.1666666,22.1666666],[-56.1666666,12.8333333],[-56.1666666,1.25],[-55.8854166,-5.8333334]],"sourceHandles":["1EC97","1EC9C","1EC9F","1ECA0","1EECE","1EECF","1EED4","1EED5","1EED6","1EED7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":347,"id":"upper-exterior-2-south-column-447","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":446,"columnIndex":13,"outlineFt":[[-54.1145833,-5.8333334],[-53.8333333,1.25],[-53.8333333,12.8333333],[-53.625,12.8333333],[-53.625,22.1666666],[-53.625,37.5],[-53.625,46.8333333],[-53.0416666,46.8333333],[-53.0416666,37.5],[-53.0416666,22.1666666],[-53.0416666,12.8333333],[-52.8333333,12.8333333],[-52.8333333,1.25],[-52.5520833,-5.8333334]],"sourceHandles":["1EC9D","1ECA2","1ECA5","1ECA6","1EECA","1EECB","1EED2","1EED3","1EEEA","1EEEB","1EEF1","1EEF2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":346,"id":"upper-exterior-2-south-column-446","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":445,"columnIndex":14,"outlineFt":[[-50.78125,-5.8333334],[-50.5,1.25],[-50.5,12.8333333],[-50.5,22.1666666],[-50.6875,22.1666666],[-50.6875,37.5],[-50.5,37.5],[-50.5,46.8333333],[-49.5,46.8333333],[-49.5,37.5],[-49.3125,37.5],[-49.3125,22.1666666],[-49.5,22.1666666],[-49.5,12.8333333],[-49.5,1.25],[-49.21875,-5.8333334]],"sourceHandles":["1ECA3","1ECA8","1ECAB","1ECAC","1EEFE","1EEFF","1EF04","1EF05","1EF06","1EF07"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":345,"id":"upper-exterior-2-south-column-445","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":444,"columnIndex":15,"outlineFt":[[-47.4479166,-5.8333334],[-47.1666666,1.25],[-47.1666666,12.8333333],[-46.9583333,12.8333333],[-46.9583333,22.1666666],[-46.9583333,37.5],[-46.9583333,46.8333333],[-46.375,46.8333333],[-46.375,37.5],[-46.375,22.1666666],[-46.375,12.8333333],[-46.1666666,12.8333333],[-46.1666666,1.25],[-45.8854166,-5.8333334]],"sourceHandles":["1ECA9","1ECAE","1ECB1","1ECB2","1EEFA","1EEFB","1EF02","1EF03","1EF1A","1EF1B","1EF21","1EF22"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":344,"id":"upper-exterior-2-south-column-444","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":443,"columnIndex":16,"outlineFt":[[-44.1145833,-5.8333334],[-43.8333333,1.25],[-43.8333333,12.8333333],[-43.8333333,22.1666666],[-44.0208333,22.1666666],[-44.0208333,37.5],[-43.8333333,37.5],[-43.8333333,46.8333333],[-42.8333333,46.8333333],[-42.8333333,37.5],[-42.6458333,37.5],[-42.6458333,22.1666666],[-42.8333333,22.1666666],[-42.8333333,12.8333333],[-42.8333333,1.25],[-42.5520833,-5.8333334]],"sourceHandles":["1ECAF","1ECB4","1ECB7","1ECB8","1EF2E","1EF2F","1EF34","1EF35","1EF36","1EF37"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":343,"id":"upper-exterior-2-south-column-443","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":442,"columnIndex":17,"outlineFt":[[-40.78125,-5.8333334],[-40.5,1.25],[-40.5,12.8333333],[-40.2916666,12.8333333],[-40.2916666,22.1666666],[-40.2916666,37.5],[-40.2916666,46.8333333],[-39.7083333,46.8333333],[-39.7083333,37.5],[-39.7083333,22.1666666],[-39.7083333,12.8333333],[-39.5,12.8333333],[-39.5,1.25],[-39.21875,-5.8333334]],"sourceHandles":["1ECB5","1ECBA","1ECBD","1ECBE","1EF2A","1EF2B","1EF32","1EF33","1EF4A","1EF4B","1EF51","1EF52"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":342,"id":"upper-exterior-2-south-column-442","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":441,"columnIndex":18,"outlineFt":[[-37.4479166,-5.8333334],[-37.1666666,1.25],[-37.1666666,12.8333333],[-37.1666666,22.1666666],[-37.3541666,22.1666666],[-37.3541666,37.5],[-37.1666666,37.5],[-37.1666666,46.8333333],[-36.1666666,46.8333333],[-36.1666666,37.5],[-35.9791666,37.5],[-35.9791666,22.1666666],[-36.1666666,22.1666666],[-36.1666666,12.8333333],[-36.1666666,1.25],[-35.8854166,-5.8333334]],"sourceHandles":["1ECBB","1ECC0","1ECC3","1ECC4","1EF5E","1EF5F","1EF64","1EF65","1EF66","1EF67"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":341,"id":"upper-exterior-2-south-column-441","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":440,"columnIndex":19,"outlineFt":[[-34.1145833,-5.8333334],[-33.8333333,1.25],[-33.8333333,12.8333333],[-33.625,12.8333333],[-33.625,22.1666666],[-33.625,37.5],[-33.625,46.8333333],[-33.0416666,46.8333333],[-33.0416666,37.5],[-33.0416666,22.1666666],[-33.0416666,12.8333333],[-32.8333333,12.8333333],[-32.8333333,1.25],[-32.5520833,-5.8333334]],"sourceHandles":["1ECC1","1ECC6","1ECC9","1ECCA","1EF5A","1EF5B","1EF62","1EF63","1EF7A","1EF7B","1EF81","1EF82"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":340,"id":"upper-exterior-2-south-column-440","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":439,"columnIndex":20,"outlineFt":[[-30.78125,-5.8333334],[-30.5,1.25],[-30.5,12.8333333],[-30.5,22.1666666],[-30.6875,22.1666666],[-30.6875,37.5],[-30.5,37.5],[-30.5,46.8333333],[-29.5,46.8333333],[-29.5,37.5],[-29.3125,37.5],[-29.3125,22.1666666],[-29.5,22.1666666],[-29.5,12.8333333],[-29.5,1.25],[-29.21875,-5.8333334]],"sourceHandles":["1ECC7","1ECCC","1ECCF","1ECD0","1EF8E","1EF8F","1EF94","1EF95","1EF96","1EF97"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":339,"id":"upper-exterior-2-south-column-439","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":438,"columnIndex":21,"outlineFt":[[-27.4479166,-5.8333334],[-27.1666666,1.25],[-27.1666666,12.8333333],[-26.9583333,12.8333333],[-26.9583333,22.1666666],[-26.9583333,37.5],[-26.9583333,46.8333333],[-26.375,46.8333333],[-26.375,37.5],[-26.375,22.1666666],[-26.375,12.8333333],[-26.1666666,12.8333333],[-26.1666666,1.25],[-25.8854166,-5.8333334]],"sourceHandles":["1ECCD","1ECD2","1ECD5","1ECD6","1EF8A","1EF8B","1EF92","1EF93","1EFAA","1EFAB","1EFB1","1EFB2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":338,"id":"upper-exterior-2-south-column-438","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":437,"columnIndex":22,"outlineFt":[[-24.1145833,-5.8333334],[-23.8333333,1.25],[-23.8333333,12.8333333],[-23.8333333,22.1666666],[-24.0208333,22.1666666],[-24.0208333,37.5],[-23.8333333,37.5],[-23.8333333,46.8333333],[-22.8333333,46.8333333],[-22.8333333,37.5],[-22.6458333,37.5],[-22.6458333,22.1666666],[-22.8333333,22.1666666],[-22.8333333,12.8333333],[-22.8333333,1.25],[-22.5520833,-5.8333334]],"sourceHandles":["1ECD3","1ECD8","1ECDB","1ECDC","1EFBE","1EFBF","1EFC4","1EFC5","1EFC6","1EFC7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":337,"id":"upper-exterior-2-south-column-437","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":436,"columnIndex":23,"outlineFt":[[-20.78125,-5.8333334],[-20.5,1.25],[-20.5,12.8333333],[-20.2916666,12.8333333],[-20.2916666,22.1666666],[-20.2916666,37.5],[-20.2916666,46.8333333],[-19.7083333,46.8333333],[-19.7083333,37.5],[-19.7083333,22.1666666],[-19.7083333,12.8333333],[-19.5,12.8333333],[-19.5,1.25],[-19.21875,-5.8333334]],"sourceHandles":["1ECD9","1ECDE","1ECE1","1ECE2","1EFBA","1EFBB","1EFC2","1EFC3","1EFDA","1EFDB","1EFE1","1EFE2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":336,"id":"upper-exterior-2-south-column-436","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":435,"columnIndex":24,"outlineFt":[[-17.4479166,-5.8333334],[-17.1666666,1.25],[-17.1666666,12.8333333],[-17.1666666,22.1666666],[-17.3541666,22.1666666],[-17.3541666,37.5],[-17.1666666,37.5],[-17.1666666,46.8333333],[-16.1666666,46.8333333],[-16.1666666,37.5],[-15.9791666,37.5],[-15.9791666,22.1666666],[-16.1666666,22.1666666],[-16.1666666,12.8333333],[-16.1666666,1.25],[-15.8854166,-5.8333334]],"sourceHandles":["1ECDF","1ECE4","1ECE7","1ECE8","1EFEE","1EFEF","1EFF4","1EFF5","1EFF6","1EFF7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":335,"id":"upper-exterior-2-south-column-435","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":434,"columnIndex":25,"outlineFt":[[-14.1145833,-5.8333334],[-13.8333333,1.25],[-13.8333333,12.8333333],[-13.625,12.8333333],[-13.625,22.1666666],[-13.625,37.5],[-13.625,46.8333333],[-13.0416666,46.8333333],[-13.0416666,37.5],[-13.0416666,22.1666666],[-13.0416666,12.8333333],[-12.8333333,12.8333333],[-12.8333333,1.25],[-12.5520833,-5.8333334]],"sourceHandles":["1ECE5","1ECEA","1ECED","1ECEE","1EFEA","1EFEB","1EFF2","1EFF3","1F00A","1F00B","1F011","1F012"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":334,"id":"upper-exterior-2-south-column-434","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":433,"columnIndex":26,"outlineFt":[[-10.78125,-5.8333334],[-10.5,1.25],[-10.5,12.8333333],[-10.5,22.1666666],[-10.6875,22.1666666],[-10.6875,37.5],[-10.5,37.5],[-10.5,46.8333333],[-9.5,46.8333333],[-9.5,37.5],[-9.3125,37.5],[-9.3125,22.1666666],[-9.5,22.1666666],[-9.5,12.8333333],[-9.5,1.25],[-9.21875,-5.8333334]],"sourceHandles":["1ECEB","1ECF0","1ECF3","1ECF4","1F01E","1F01F","1F024","1F025","1F026","1F027"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":333,"id":"upper-exterior-2-south-column-433","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":432,"columnIndex":27,"outlineFt":[[-7.4479166,-5.8333334],[-7.1666666,1.25],[-7.1666666,12.8333333],[-6.9583333,12.8333333],[-6.9583333,22.1666666],[-6.9583333,37.5],[-6.9583333,46.8333333],[-6.375,46.8333333],[-6.375,37.5],[-6.375,22.1666666],[-6.375,12.8333333],[-6.1666666,12.8333333],[-6.1666666,1.25],[-5.8854166,-5.8333334]],"sourceHandles":["1ECF1","1ECF6","1ECF9","1ECFA","1F01A","1F01B","1F022","1F023","1F03A","1F03B","1F041","1F042"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":332,"id":"upper-exterior-2-south-column-432","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":431,"columnIndex":28,"outlineFt":[[-4.1145833,-5.8333334],[-3.8333333,1.25],[-3.8333333,12.8333333],[-3.8333333,22.1666666],[-4.0208333,22.1666666],[-4.0208333,37.5],[-3.8333333,37.5],[-3.8333333,46.8333333],[-2.8333333,46.8333333],[-2.8333333,37.5],[-2.6458333,37.5],[-2.6458333,22.1666666],[-2.8333333,22.1666666],[-2.8333333,12.8333333],[-2.8333333,1.25],[-2.5520833,-5.8333334]],"sourceHandles":["1ECF7","1ECFC","1ECFF","1ED00","1F04E","1F04F","1F054","1F055","1F056","1F057"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":331,"id":"upper-exterior-2-south-column-431","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":430,"columnIndex":29,"outlineFt":[[-0.78125,-5.8333334],[-0.5,1.25],[-0.5,12.8333333],[-0.2916666,12.8333333],[-0.2916666,22.1666666],[-0.2916666,37.5],[-0.2916666,46.8333333],[0.2916667,46.8333333],[0.2916667,37.5],[0.2916667,22.1666666],[0.2916667,12.8333333],[0.5,12.8333333],[0.5,1.25],[0.78125,-5.8333334]],"sourceHandles":["1ECFD","1ED02","1ED05","1ED06","1F04A","1F04B","1F052","1F053","1F06A","1F06B","1F071","1F072"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":330,"id":"upper-exterior-2-south-column-430","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":429,"columnIndex":30,"outlineFt":[[2.5520834,-5.8333334],[2.8333334,1.25],[2.8333334,12.8333333],[2.8333334,22.1666666],[2.6458334,22.1666666],[2.6458334,37.5],[2.8333334,37.5],[2.8333334,46.8333333],[3.8333334,46.8333333],[3.8333334,37.5],[4.0208334,37.5],[4.0208334,22.1666666],[3.8333334,22.1666666],[3.8333334,12.8333333],[3.8333334,1.25],[4.1145834,-5.8333334]],"sourceHandles":["1ED03","1ED08","1ED0B","1ED0C","1F07E","1F07F","1F084","1F085","1F086","1F087"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":329,"id":"upper-exterior-2-south-column-429","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":428,"columnIndex":31,"outlineFt":[[5.8854167,-5.8333334],[6.1666667,1.25],[6.1666667,12.8333333],[6.375,12.8333333],[6.375,22.1666666],[6.375,37.5],[6.375,46.8333333],[6.9583334,46.8333333],[6.9583334,37.5],[6.9583334,22.1666666],[6.9583334,12.8333333],[7.1666667,12.8333333],[7.1666667,1.25],[7.4479167,-5.8333334]],"sourceHandles":["1ED09","1ED0E","1ED11","1ED12","1F07A","1F07B","1F082","1F083","1F09A","1F09B","1F0A1","1F0A2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":328,"id":"upper-exterior-2-south-column-428","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":427,"columnIndex":32,"outlineFt":[[9.21875,-5.8333334],[9.5,1.25],[9.5,12.8333333],[9.5,22.1666666],[9.3125,22.1666666],[9.3125,37.5],[9.5,37.5],[9.5,46.8333333],[10.5,46.8333333],[10.5,37.5],[10.6875,37.5],[10.6875,22.1666666],[10.5,22.1666666],[10.5,12.8333333],[10.5,1.25],[10.78125,-5.8333334]],"sourceHandles":["1ED0F","1ED14","1ED17","1ED18","1F0AE","1F0AF","1F0B4","1F0B5","1F0B6","1F0B7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":327,"id":"upper-exterior-2-south-column-427","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":426,"columnIndex":33,"outlineFt":[[12.5520834,-5.8333334],[12.8333334,1.25],[12.8333334,12.8333333],[13.0416667,12.8333333],[13.0416667,22.1666666],[13.0416667,37.5],[13.0416667,46.8333333],[13.625,46.8333333],[13.625,37.5],[13.625,22.1666666],[13.625,12.8333333],[13.8333334,12.8333333],[13.8333334,1.25],[14.1145834,-5.8333334]],"sourceHandles":["1ED15","1ED1A","1ED1D","1ED1E","1F0AA","1F0AB","1F0B2","1F0B3","1F0CA","1F0CB","1F0D1","1F0D2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":326,"id":"upper-exterior-2-south-column-426","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":425,"columnIndex":34,"outlineFt":[[15.8854167,-5.8333334],[16.1666667,1.25],[16.1666667,12.8333333],[16.1666667,22.1666666],[15.9791667,22.1666666],[15.9791667,37.5],[16.1666667,37.5],[16.1666667,46.8333333],[17.1666667,46.8333333],[17.1666667,37.5],[17.3541667,37.5],[17.3541667,22.1666666],[17.1666667,22.1666666],[17.1666667,12.8333333],[17.1666667,1.25],[17.4479167,-5.8333334]],"sourceHandles":["1ED1B","1ED20","1ED23","1ED24","1F0DE","1F0DF","1F0E4","1F0E5","1F0E6","1F0E7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":325,"id":"upper-exterior-2-south-column-425","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":424,"columnIndex":35,"outlineFt":[[19.21875,-5.8333334],[19.5,1.25],[19.5,12.8333333],[19.7083334,12.8333333],[19.7083334,22.1666666],[19.7083334,37.5],[19.7083334,46.8333333],[20.2916667,46.8333333],[20.2916667,37.5],[20.2916667,22.1666666],[20.2916667,12.8333333],[20.5,12.8333333],[20.5,1.25],[20.78125,-5.8333334]],"sourceHandles":["1ED21","1ED26","1ED29","1ED2A","1F0DA","1F0DB","1F0E2","1F0E3","1F0FA","1F0FB","1F101","1F102"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":324,"id":"upper-exterior-2-south-column-424","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":423,"columnIndex":36,"outlineFt":[[22.5520834,-5.8333334],[22.8333334,1.25],[22.8333334,12.8333333],[22.8333334,22.1666666],[22.6458334,22.1666666],[22.6458334,37.5],[22.8333334,37.5],[22.8333334,46.8333333],[23.8333334,46.8333333],[23.8333334,37.5],[24.0208334,37.5],[24.0208334,22.1666666],[23.8333334,22.1666666],[23.8333334,12.8333333],[23.8333334,1.25],[24.1145834,-5.8333334]],"sourceHandles":["1ED27","1ED2C","1ED2F","1ED30","1F10E","1F10F","1F114","1F115","1F116","1F117"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":323,"id":"upper-exterior-2-south-column-423","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":422,"columnIndex":37,"outlineFt":[[25.8854167,-5.8333334],[26.1666667,1.25],[26.1666667,12.8333333],[26.375,12.8333333],[26.375,22.1666666],[26.375,37.5],[26.375,46.8333333],[26.9583334,46.8333333],[26.9583334,37.5],[26.9583334,22.1666666],[26.9583334,12.8333333],[27.1666667,12.8333333],[27.1666667,1.25],[27.4479167,-5.8333334]],"sourceHandles":["1ED2D","1ED32","1ED35","1ED36","1F10A","1F10B","1F112","1F113","1F12A","1F12B","1F131","1F132"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":322,"id":"upper-exterior-2-south-column-422","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":421,"columnIndex":38,"outlineFt":[[29.21875,-5.8333334],[29.5,1.25],[29.5,12.8333333],[29.5,22.1666666],[29.3125,22.1666666],[29.3125,37.5],[29.5,37.5],[29.5,46.8333333],[30.5,46.8333333],[30.5,37.5],[30.6875,37.5],[30.6875,22.1666666],[30.5,22.1666666],[30.5,12.8333333],[30.5,1.25],[30.78125,-5.8333334]],"sourceHandles":["1ED33","1ED38","1ED3B","1ED3C","1F13E","1F13F","1F144","1F145","1F146","1F147"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":321,"id":"upper-exterior-2-south-column-421","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":420,"columnIndex":39,"outlineFt":[[32.5520834,-5.8333334],[32.8333334,1.25],[32.8333334,12.8333333],[33.0416667,12.8333333],[33.0416667,22.1666666],[33.0416667,37.5],[33.0416667,46.8333333],[33.625,46.8333333],[33.625,37.5],[33.625,22.1666666],[33.625,12.8333333],[33.8333334,12.8333333],[33.8333334,1.25],[34.1145834,-5.8333334]],"sourceHandles":["1ED39","1ED3E","1ED41","1ED42","1F13A","1F13B","1F142","1F143","1F15A","1F15B","1F161","1F162"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":320,"id":"upper-exterior-2-south-column-420","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":419,"columnIndex":40,"outlineFt":[[35.8854167,-5.8333334],[36.1666667,1.25],[36.1666667,12.8333333],[36.1666667,22.1666666],[35.9791667,22.1666666],[35.9791667,37.5],[36.1666667,37.5],[36.1666667,46.8333333],[37.1666667,46.8333333],[37.1666667,37.5],[37.3541667,37.5],[37.3541667,22.1666666],[37.1666667,22.1666666],[37.1666667,12.8333333],[37.1666667,1.25],[37.4479167,-5.8333334]],"sourceHandles":["1ED3F","1ED44","1ED47","1ED48","1F16E","1F16F","1F174","1F175","1F176","1F177"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":319,"id":"upper-exterior-2-south-column-419","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":418,"columnIndex":41,"outlineFt":[[39.21875,-5.8333334],[39.5,1.25],[39.5,12.8333333],[39.7083334,12.8333333],[39.7083334,22.1666666],[39.7083334,37.5],[39.7083334,46.8333333],[40.2916667,46.8333333],[40.2916667,37.5],[40.2916667,22.1666666],[40.2916667,12.8333333],[40.5,12.8333333],[40.5,1.25],[40.78125,-5.8333334]],"sourceHandles":["1ED45","1ED4A","1ED4D","1ED4E","1F16A","1F16B","1F172","1F173","1F18A","1F18B","1F191","1F192"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":318,"id":"upper-exterior-2-south-column-418","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":417,"columnIndex":42,"outlineFt":[[42.5520834,-5.8333334],[42.8333334,1.25],[42.8333334,12.8333333],[42.8333334,22.1666666],[42.6458334,22.1666666],[42.6458334,37.5],[42.8333334,37.5],[42.8333334,46.8333333],[43.8333334,46.8333333],[43.8333334,37.5],[44.0208334,37.5],[44.0208334,22.1666666],[43.8333334,22.1666666],[43.8333334,12.8333333],[43.8333334,1.25],[44.1145834,-5.8333334]],"sourceHandles":["1ED4B","1ED50","1ED53","1ED54","1F19E","1F19F","1F1A4","1F1A5","1F1A6","1F1A7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":317,"id":"upper-exterior-2-south-column-417","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":416,"columnIndex":43,"outlineFt":[[45.8854167,-5.8333334],[46.1666667,1.25],[46.1666667,12.8333333],[46.375,12.8333333],[46.375,22.1666666],[46.375,37.5],[46.375,46.8333333],[46.9583334,46.8333333],[46.9583334,37.5],[46.9583334,22.1666666],[46.9583334,12.8333333],[47.1666667,12.8333333],[47.1666667,1.25],[47.4479167,-5.8333334]],"sourceHandles":["1ED51","1ED56","1ED59","1ED5A","1F19A","1F19B","1F1A2","1F1A3","1F1BA","1F1BB","1F1C1","1F1C2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":316,"id":"upper-exterior-2-south-column-416","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":415,"columnIndex":44,"outlineFt":[[49.21875,-5.8333334],[49.5,1.25],[49.5,12.8333333],[49.5,22.1666666],[49.3125,22.1666666],[49.3125,37.5],[49.5,37.5],[49.5,46.8333333],[50.5,46.8333333],[50.5,37.5],[50.6875,37.5],[50.6875,22.1666666],[50.5,22.1666666],[50.5,12.8333333],[50.5,1.25],[50.78125,-5.8333334]],"sourceHandles":["1ED57","1ED5C","1ED5F","1ED60","1F1CE","1F1CF","1F1D4","1F1D5","1F1D6","1F1D7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":315,"id":"upper-exterior-2-south-column-415","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":414,"columnIndex":45,"outlineFt":[[52.5520834,-5.8333334],[52.8333334,1.25],[52.8333334,12.8333333],[53.0416667,12.8333333],[53.0416667,22.1666666],[53.0416667,37.5],[53.0416667,46.8333333],[53.625,46.8333333],[53.625,37.5],[53.625,22.1666666],[53.625,12.8333333],[53.8333334,12.8333333],[53.8333334,1.25],[54.1145834,-5.8333334]],"sourceHandles":["1ED5D","1ED62","1ED65","1ED66","1F1CA","1F1CB","1F1D2","1F1D3","1F1EA","1F1EB","1F1F1","1F1F2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":314,"id":"upper-exterior-2-south-column-414","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":413,"columnIndex":46,"outlineFt":[[55.8854167,-5.8333334],[56.1666667,1.25],[56.1666667,12.8333333],[56.1666667,22.1666666],[55.9791667,22.1666666],[55.9791667,37.5],[56.1666667,37.5],[56.1666667,46.8333333],[57.1666667,46.8333333],[57.1666667,37.5],[57.3541667,37.5],[57.3541667,22.1666666],[57.1666667,22.1666666],[57.1666667,12.8333333],[57.1666667,1.25],[57.4479167,-5.8333334]],"sourceHandles":["1ED63","1ED68","1ED6B","1ED6C","1F1FE","1F1FF","1F204","1F205","1F206","1F207"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":313,"id":"upper-exterior-2-south-column-413","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":412,"columnIndex":47,"outlineFt":[[59.21875,-5.8333334],[59.5,1.25],[59.5,12.8333333],[59.7083334,12.8333333],[59.7083334,22.1666666],[59.7083334,37.5],[59.7083334,46.8333333],[60.2916667,46.8333333],[60.2916667,37.5],[60.2916667,22.1666666],[60.2916667,12.8333333],[60.5,12.8333333],[60.5,1.25],[60.78125,-5.8333334]],"sourceHandles":["1ED69","1ED6E","1ED71","1ED72","1F1FA","1F1FB","1F202","1F203","1F21A","1F21B","1F221","1F222"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":312,"id":"upper-exterior-2-south-column-412","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":411,"columnIndex":48,"outlineFt":[[62.5520834,-5.8333334],[62.8333334,1.25],[62.8333334,12.8333333],[62.8333334,22.1666666],[62.6458334,22.1666666],[62.6458334,37.5],[62.8333334,37.5],[62.8333334,46.8333333],[63.8333334,46.8333333],[63.8333334,37.5],[64.0208334,37.5],[64.0208334,22.1666666],[63.8333334,22.1666666],[63.8333334,12.8333333],[63.8333334,1.25],[64.1145834,-5.8333334]],"sourceHandles":["1ED6F","1ED74","1ED77","1ED78","1F22E","1F22F","1F234","1F235","1F236","1F237"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":311,"id":"upper-exterior-2-south-column-411","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":410,"columnIndex":49,"outlineFt":[[65.8854167,-5.8333334],[66.1666667,1.25],[66.1666667,12.8333333],[66.375,12.8333333],[66.375,22.1666666],[66.375,37.5],[66.375,46.8333333],[66.9583334,46.8333333],[66.9583334,37.5],[66.9583334,22.1666666],[66.9583334,12.8333333],[67.1666667,12.8333333],[67.1666667,1.25],[67.4479167,-5.8333334]],"sourceHandles":["1ED75","1ED7A","1ED7D","1ED7E","1F22A","1F22B","1F232","1F233","1F24A","1F24B","1F251","1F252"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":310,"id":"upper-exterior-2-south-column-410","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":409,"columnIndex":50,"outlineFt":[[69.21875,-5.8333334],[69.5,1.25],[69.5,12.8333333],[69.5,22.1666666],[69.3125,22.1666666],[69.3125,37.5],[69.5,37.5],[69.5,46.8333333],[70.5,46.8333333],[70.5,37.5],[70.6875,37.5],[70.6875,22.1666666],[70.5,22.1666666],[70.5,12.8333333],[70.5,1.25],[70.78125,-5.8333334]],"sourceHandles":["1ED7B","1ED80","1ED83","1ED84","1F25E","1F25F","1F264","1F265","1F266","1F267"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":309,"id":"upper-exterior-2-south-column-409","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":408,"columnIndex":51,"outlineFt":[[72.5520834,-5.8333334],[72.8333334,1.25],[72.8333334,12.8333333],[73.0416667,12.8333333],[73.0416667,22.1666666],[73.0416667,37.5],[73.0416667,46.8333333],[73.625,46.8333333],[73.625,37.5],[73.625,22.1666666],[73.625,12.8333333],[73.8333334,12.8333333],[73.8333334,1.25],[74.1145834,-5.8333334]],"sourceHandles":["1ED81","1ED86","1ED89","1ED8A","1F25A","1F25B","1F262","1F263","1F27A","1F27B","1F281","1F282"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":308,"id":"upper-exterior-2-south-column-408","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":407,"columnIndex":52,"outlineFt":[[75.8854167,-5.8333334],[76.1666667,1.25],[76.1666667,12.8333333],[76.1666667,22.1666666],[75.9791667,22.1666666],[75.9791667,37.5],[76.1666667,37.5],[76.1666667,46.8333333],[77.1666667,46.8333333],[77.1666667,37.5],[77.3541667,37.5],[77.3541667,22.1666666],[77.1666667,22.1666666],[77.1666667,12.8333333],[77.1666667,1.25],[77.4479167,-5.8333334]],"sourceHandles":["1ED87","1ED8C","1ED8F","1ED90","1F28E","1F28F","1F294","1F295","1F296","1F297"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":307,"id":"upper-exterior-2-south-column-407","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":406,"columnIndex":53,"outlineFt":[[79.21875,-5.8333334],[79.5,1.25],[79.5,12.8333333],[79.7083334,12.8333333],[79.7083334,22.1666666],[79.7083334,37.5],[79.7083334,46.8333333],[80.2916667,46.8333333],[80.2916667,37.5],[80.2916667,22.1666666],[80.2916667,12.8333333],[80.5,12.8333333],[80.5,1.25],[80.78125,-5.8333334]],"sourceHandles":["1ED8D","1ED92","1ED95","1ED96","1F28A","1F28B","1F292","1F293","1F2AA","1F2AB","1F2B1","1F2B2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":306,"id":"upper-exterior-2-south-column-406","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":405,"columnIndex":54,"outlineFt":[[82.5520834,-5.8333334],[82.8333334,1.25],[82.8333334,12.8333333],[82.8333334,22.1666666],[82.6458334,22.1666666],[82.6458334,37.5],[82.8333334,37.5],[82.8333334,46.8333333],[83.8333334,46.8333333],[83.8333334,37.5],[84.0208334,37.5],[84.0208334,22.1666666],[83.8333334,22.1666666],[83.8333334,12.8333333],[83.8333334,1.25],[84.1145834,-5.8333334]],"sourceHandles":["1ED93","1ED98","1ED9B","1ED9C","1F2BE","1F2BF","1F2C4","1F2C5","1F2C6","1F2C7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":305,"id":"upper-exterior-2-south-column-405","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":404,"columnIndex":55,"outlineFt":[[85.8854167,-5.8333334],[86.1666667,1.25],[86.1666667,12.8333333],[86.375,12.8333333],[86.375,22.1666666],[86.375,37.5],[86.375,46.8333333],[86.9583334,46.8333333],[86.9583334,37.5],[86.9583334,22.1666666],[86.9583334,12.8333333],[87.1666667,12.8333333],[87.1666667,1.25],[87.4479167,-5.8333334]],"sourceHandles":["1ED99","1ED9E","1EDA1","1EDA2","1F2BA","1F2BB","1F2C2","1F2C3","1F2DA","1F2DB","1F2E1","1F2E2"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":304,"id":"upper-exterior-2-south-column-404","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":403,"columnIndex":56,"outlineFt":[[89.21875,-5.8333334],[89.5,1.25],[89.5,12.8333333],[89.5,22.1666666],[89.3125,22.1666666],[89.3125,37.5],[89.5,37.5],[89.5,46.8333333],[90.5,46.8333333],[90.5,37.5],[90.6875,37.5],[90.6875,22.1666666],[90.5,22.1666666],[90.5,12.8333333],[90.5,1.25],[90.78125,-5.8333334]],"sourceHandles":["1ED9F","1EDA4","1EDA7","1EDA8","1F2EE","1F2EF","1F2F4","1F2F5","1F2F6","1F2F7"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":303,"id":"upper-exterior-2-south-column-403","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":402,"columnIndex":57,"outlineFt":[[92.5520834,-5.8333334],[92.8333334,1.25],[92.8333334,12.8333333],[93.0416667,12.8333333],[93.0416667,22.1666666],[93.0416667,37.5],[93.0416667,46.8333333],[93.625,46.8333333],[93.625,37.5],[93.625,22.1666666],[93.625,12.8333333],[93.8333334,12.8333333],[93.8333334,1.25],[94.1145834,-5.8333334]],"sourceHandles":["1EDA5","1EDAA","1EDAC","1EDAD","1F2EA","1F2EB","1F2F2","1F2F3","1F30A","1F30B","1F311","1F312"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":302,"id":"upper-exterior-2-south-column-402","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":401,"columnIndex":58,"outlineFt":[[95.8854167,-5.8333334],[96.1170343,-0.0],[96.1666667,1.25],[96.1668614,1.25],[96.1668614,17.5],[96.1668614,17.5049035],[96.1668614,22.1666666],[95.9791667,22.1666666],[95.9791667,37.5],[96.1668614,37.5],[96.1668614,49.0833333],[98.375,49.0833333],[98.375,37.5],[98.375,22.1666666],[98.375,17.5049035],[98.375,17.5],[98.375,1.25],[98.375,-0.0],[98.375,-5.8333334]],"sourceHandles":["1EDAE","1EDAF","1EDB0","1EDB2","1EDB4","1EDB5","1EDB6","1F320","1F322"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":301,"id":"upper-exterior-2-south-column-401","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[-93.8333333,1.25],[-94.1145833,-5.8333334],[-95.8854166,-5.8333334],[-96.1170343,-0.0],[-96.1666666,1.25]],"sourceHandles":["1EC49","1EC4A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-0","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[-90.5,1.25],[-90.78125,-5.8333334],[-92.5520833,-5.8333334],[-92.8333333,1.25]],"sourceHandles":["1EC48","1EC4E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-1","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[-87.1666666,1.25],[-87.4479166,-5.8333334],[-89.21875,-5.8333334],[-89.5,1.25]],"sourceHandles":["1EC5F","1EC62"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-2","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[-83.8333333,1.25],[-84.1145833,-5.8333334],[-85.8854166,-5.8333334],[-86.1666666,1.25]],"sourceHandles":["1EC65","1EC68"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-3","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[-80.5,1.25],[-80.78125,-5.8333334],[-82.5520833,-5.8333334],[-82.8333333,1.25]],"sourceHandles":["1EC6B","1EC6E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-4","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[-77.1666666,1.25],[-77.4479166,-5.8333334],[-79.21875,-5.8333334],[-79.5,1.25]],"sourceHandles":["1EC71","1EC74"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-5","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[-73.8333333,1.25],[-74.1145833,-5.8333334],[-75.8854166,-5.8333334],[-76.1666666,1.25]],"sourceHandles":["1EC77","1EC7A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-6","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[-70.5,1.25],[-70.78125,-5.8333334],[-72.5520833,-5.8333334],[-72.8333333,1.25]],"sourceHandles":["1EC7D","1EC80"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-7","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[-67.1666666,1.25],[-67.4479166,-5.8333334],[-69.21875,-5.8333334],[-69.5,1.25]],"sourceHandles":["1EC83","1EC86"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-8","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[-63.8333333,1.25],[-64.1145833,-5.8333334],[-65.8854166,-5.8333334],[-66.1666666,1.25]],"sourceHandles":["1EC89","1EC8C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-9","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[-60.5,1.25],[-60.78125,-5.8333334],[-62.5520833,-5.8333334],[-62.8333333,1.25]],"sourceHandles":["1EC8F","1EC92"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-10","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[-57.1666666,1.25],[-57.4479166,-5.8333334],[-59.21875,-5.8333334],[-59.5,1.25]],"sourceHandles":["1EC95","1EC98"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-11","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[-53.8333333,1.25],[-54.1145833,-5.8333334],[-55.8854166,-5.8333334],[-56.1666666,1.25]],"sourceHandles":["1EC9B","1EC9E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-12","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[-50.5,1.25],[-50.78125,-5.8333334],[-52.5520833,-5.8333334],[-52.8333333,1.25]],"sourceHandles":["1ECA1","1ECA4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-13","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[-47.1666666,1.25],[-47.4479166,-5.8333334],[-49.21875,-5.8333334],[-49.5,1.25]],"sourceHandles":["1ECA7","1ECAA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-14","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[-43.8333333,1.25],[-44.1145833,-5.8333334],[-45.8854166,-5.8333334],[-46.1666666,1.25]],"sourceHandles":["1ECAD","1ECB0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-15","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[-40.5,1.25],[-40.78125,-5.8333334],[-42.5520833,-5.8333334],[-42.8333333,1.25]],"sourceHandles":["1ECB3","1ECB6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-16","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[-37.1666666,1.25],[-37.4479166,-5.8333334],[-39.21875,-5.8333334],[-39.5,1.25]],"sourceHandles":["1ECB9","1ECBC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-17","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[-33.8333333,1.25],[-34.1145833,-5.8333334],[-35.8854166,-5.8333334],[-36.1666666,1.25]],"sourceHandles":["1ECBF","1ECC2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-18","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[-30.5,1.25],[-30.78125,-5.8333334],[-32.5520833,-5.8333334],[-32.8333333,1.25]],"sourceHandles":["1ECC5","1ECC8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-19","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[-27.1666666,1.25],[-27.4479166,-5.8333334],[-29.21875,-5.8333334],[-29.5,1.25]],"sourceHandles":["1ECCB","1ECCE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-20","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[-23.8333333,1.25],[-24.1145833,-5.8333334],[-25.8854166,-5.8333334],[-26.1666666,1.25]],"sourceHandles":["1ECD1","1ECD4"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-21","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[-20.5,1.25],[-20.78125,-5.8333334],[-22.5520833,-5.8333334],[-22.8333333,1.25]],"sourceHandles":["1ECD7","1ECDA"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-22","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[-17.1666666,1.25],[-17.4479166,-5.8333334],[-19.21875,-5.8333334],[-19.5,1.25]],"sourceHandles":["1ECDD","1ECE0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-23","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[-13.8333333,1.25],[-14.1145833,-5.8333334],[-15.8854166,-5.8333334],[-16.1666666,1.25]],"sourceHandles":["1ECE3","1ECE6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-24","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[-10.5,1.25],[-10.78125,-5.8333334],[-12.5520833,-5.8333334],[-12.8333333,1.25]],"sourceHandles":["1ECE9","1ECEC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-25","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[-7.1666666,1.25],[-7.4479166,-5.8333334],[-9.21875,-5.8333334],[-9.5,1.25]],"sourceHandles":["1ECEF","1ECF2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-26","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[-3.8333333,1.25],[-4.1145833,-5.8333334],[-5.8854166,-5.8333334],[-6.1666666,1.25]],"sourceHandles":["1ECF5","1ECF8"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-27","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[-0.5,1.25],[-0.78125,-5.8333334],[-2.5520833,-5.8333334],[-2.8333333,1.25]],"sourceHandles":["1ECFB","1ECFE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-28","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[2.8333334,1.25],[2.5520834,-5.8333334],[0.78125,-5.8333334],[0.5,1.25]],"sourceHandles":["1ED01","1ED04"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-29","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[6.1666667,1.25],[5.8854167,-5.8333334],[4.1145834,-5.8333334],[3.8333334,1.25]],"sourceHandles":["1ED07","1ED0A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-30","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[9.5,1.25],[9.21875,-5.8333334],[7.4479167,-5.8333334],[7.1666667,1.25]],"sourceHandles":["1ED0D","1ED10"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-31","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[12.8333334,1.25],[12.5520834,-5.8333334],[10.78125,-5.8333334],[10.5,1.25]],"sourceHandles":["1ED13","1ED16"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-32","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[16.1666667,1.25],[15.8854167,-5.8333334],[14.1145834,-5.8333334],[13.8333334,1.25]],"sourceHandles":["1ED19","1ED1C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-33","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[19.5,1.25],[19.21875,-5.8333334],[17.4479167,-5.8333334],[17.1666667,1.25]],"sourceHandles":["1ED1F","1ED22"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-34","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[22.8333334,1.25],[22.5520834,-5.8333334],[20.78125,-5.8333334],[20.5,1.25]],"sourceHandles":["1ED25","1ED28"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-35","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[26.1666667,1.25],[25.8854167,-5.8333334],[24.1145834,-5.8333334],[23.8333334,1.25]],"sourceHandles":["1ED2B","1ED2E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-36","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[29.5,1.25],[29.21875,-5.8333334],[27.4479167,-5.8333334],[27.1666667,1.25]],"sourceHandles":["1ED31","1ED34"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-37","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[32.8333334,1.25],[32.5520834,-5.8333334],[30.78125,-5.8333334],[30.5,1.25]],"sourceHandles":["1ED37","1ED3A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-38","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[36.1666667,1.25],[35.8854167,-5.8333334],[34.1145834,-5.8333334],[33.8333334,1.25]],"sourceHandles":["1ED3D","1ED40"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-39","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[39.5,1.25],[39.21875,-5.8333334],[37.4479167,-5.8333334],[37.1666667,1.25]],"sourceHandles":["1ED43","1ED46"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-40","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[42.8333334,1.25],[42.5520834,-5.8333334],[40.78125,-5.8333334],[40.5,1.25]],"sourceHandles":["1ED49","1ED4C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-41","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[46.1666667,1.25],[45.8854167,-5.8333334],[44.1145834,-5.8333334],[43.8333334,1.25]],"sourceHandles":["1ED4F","1ED52"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-42","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[49.5,1.25],[49.21875,-5.8333334],[47.4479167,-5.8333334],[47.1666667,1.25]],"sourceHandles":["1ED55","1ED58"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-43","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[52.8333334,1.25],[52.5520834,-5.8333334],[50.78125,-5.8333334],[50.5,1.25]],"sourceHandles":["1ED5B","1ED5E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-44","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[56.1666667,1.25],[55.8854167,-5.8333334],[54.1145834,-5.8333334],[53.8333334,1.25]],"sourceHandles":["1ED61","1ED64"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-45","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[59.5,1.25],[59.21875,-5.8333334],[57.4479167,-5.8333334],[57.1666667,1.25]],"sourceHandles":["1ED67","1ED6A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-46","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[62.8333334,1.25],[62.5520834,-5.8333334],[60.78125,-5.8333334],[60.5,1.25]],"sourceHandles":["1ED6D","1ED70"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-47","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[66.1666667,1.25],[65.8854167,-5.8333334],[64.1145834,-5.8333334],[63.8333334,1.25]],"sourceHandles":["1ED73","1ED76"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-48","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[69.5,1.25],[69.21875,-5.8333334],[67.4479167,-5.8333334],[67.1666667,1.25]],"sourceHandles":["1ED79","1ED7C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-49","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[72.8333334,1.25],[72.5520834,-5.8333334],[70.78125,-5.8333334],[70.5,1.25]],"sourceHandles":["1ED7F","1ED82"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-50","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[76.1666667,1.25],[75.8854167,-5.8333334],[74.1145834,-5.8333334],[73.8333334,1.25]],"sourceHandles":["1ED85","1ED88"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-51","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[79.5,1.25],[79.21875,-5.8333334],[77.4479167,-5.8333334],[77.1666667,1.25]],"sourceHandles":["1ED8B","1ED8E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-52","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[82.8333334,1.25],[82.5520834,-5.8333334],[80.78125,-5.8333334],[80.5,1.25]],"sourceHandles":["1ED91","1ED94"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-53","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[86.1666667,1.25],[85.8854167,-5.8333334],[84.1145834,-5.8333334],[83.8333334,1.25]],"sourceHandles":["1ED97","1ED9A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-54","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[89.5,1.25],[89.21875,-5.8333334],[87.4479167,-5.8333334],[87.1666667,1.25]],"sourceHandles":["1ED9D","1EDA0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-55","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[92.8333334,1.25],[92.5520834,-5.8333334],[90.78125,-5.8333334],[90.5,1.25]],"sourceHandles":["1EDA3","1EDA6"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-56","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[96.1666667,1.25],[96.1170343,-0.0],[95.8854167,-5.8333334],[94.1145834,-5.8333334],[93.8333334,1.25]],"sourceHandles":["1EDA9","1EDAB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-107-57","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[-93.625,18.8333333],[-93.625,12.8333333],[-93.8333333,12.8333333],[-96.1666666,12.8333333],[-96.1666666,17.5],[-96.1666666,18.8333333]],"sourceHandles":["1EDBF","1EDC0","1EDDD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-0","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[-90.5,18.8333333],[-90.5,12.8333333],[-92.8333333,12.8333333],[-93.0416666,12.8333333],[-93.0416666,18.8333333]],"sourceHandles":["1EDDB","1EDDC","1EDDF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-1","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[-86.9583333,18.8333333],[-86.9583333,12.8333333],[-87.1666666,12.8333333],[-89.5,12.8333333],[-89.5,18.8333333]],"sourceHandles":["1EDD9","1EDDA","1EDE0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-2","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[-83.8333333,18.8333333],[-83.8333333,12.8333333],[-86.1666666,12.8333333],[-86.375,12.8333333],[-86.375,18.8333333]],"sourceHandles":["1EE20","1EE21","1EE22"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-3","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[-80.2916666,18.8333333],[-80.2916666,12.8333333],[-80.5,12.8333333],[-82.8333333,12.8333333],[-82.8333333,18.8333333]],"sourceHandles":["1EE1E","1EE1F","1EE23"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-4","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[-77.1666666,18.8333333],[-77.1666666,12.8333333],[-79.5,12.8333333],[-79.7083333,12.8333333],[-79.7083333,18.8333333]],"sourceHandles":["1EE50","1EE51","1EE52"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-5","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[-73.625,18.8333333],[-73.625,12.8333333],[-73.8333333,12.8333333],[-76.1666666,12.8333333],[-76.1666666,18.8333333]],"sourceHandles":["1EE4E","1EE4F","1EE53"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-6","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[-70.5,18.8333333],[-70.5,12.8333333],[-72.8333333,12.8333333],[-73.0416666,12.8333333],[-73.0416666,18.8333333]],"sourceHandles":["1EE80","1EE81","1EE82"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-7","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[-66.9583333,18.8333333],[-66.9583333,12.8333333],[-67.1666666,12.8333333],[-69.5,12.8333333],[-69.5,18.8333333]],"sourceHandles":["1EE7E","1EE7F","1EE83"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-8","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[-63.8333333,18.8333333],[-63.8333333,12.8333333],[-66.1666666,12.8333333],[-66.375,12.8333333],[-66.375,18.8333333]],"sourceHandles":["1EEB0","1EEB1","1EEB2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-9","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[-60.2916666,18.8333333],[-60.2916666,12.8333333],[-60.5,12.8333333],[-62.8333333,12.8333333],[-62.8333333,18.8333333]],"sourceHandles":["1EEAE","1EEAF","1EEB3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-10","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[-57.1666666,18.8333333],[-57.1666666,12.8333333],[-59.5,12.8333333],[-59.7083333,12.8333333],[-59.7083333,18.8333333]],"sourceHandles":["1EEE0","1EEE1","1EEE2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-11","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[-53.625,18.8333333],[-53.625,12.8333333],[-53.8333333,12.8333333],[-56.1666666,12.8333333],[-56.1666666,18.8333333]],"sourceHandles":["1EEDE","1EEDF","1EEE3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-12","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[-50.5,18.8333333],[-50.5,12.8333333],[-52.8333333,12.8333333],[-53.0416666,12.8333333],[-53.0416666,18.8333333]],"sourceHandles":["1EF10","1EF11","1EF12"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-13","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[-46.9583333,18.8333333],[-46.9583333,12.8333333],[-47.1666666,12.8333333],[-49.5,12.8333333],[-49.5,18.8333333]],"sourceHandles":["1EF0E","1EF0F","1EF13"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-14","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[-43.8333333,18.8333333],[-43.8333333,12.8333333],[-46.1666666,12.8333333],[-46.375,12.8333333],[-46.375,18.8333333]],"sourceHandles":["1EF40","1EF41","1EF42"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-15","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[-40.2916666,18.8333333],[-40.2916666,12.8333333],[-40.5,12.8333333],[-42.8333333,12.8333333],[-42.8333333,18.8333333]],"sourceHandles":["1EF3E","1EF3F","1EF43"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-16","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[-37.1666666,18.8333333],[-37.1666666,12.8333333],[-39.5,12.8333333],[-39.7083333,12.8333333],[-39.7083333,18.8333333]],"sourceHandles":["1EF70","1EF71","1EF72"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-17","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[-33.625,18.8333333],[-33.625,12.8333333],[-33.8333333,12.8333333],[-36.1666666,12.8333333],[-36.1666666,18.8333333]],"sourceHandles":["1EF6E","1EF6F","1EF73"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-18","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[-30.5,18.8333333],[-30.5,12.8333333],[-32.8333333,12.8333333],[-33.0416666,12.8333333],[-33.0416666,18.8333333]],"sourceHandles":["1EFA0","1EFA1","1EFA2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-19","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[-26.9583333,18.8333333],[-26.9583333,12.8333333],[-27.1666666,12.8333333],[-29.5,12.8333333],[-29.5,18.8333333]],"sourceHandles":["1EF9E","1EF9F","1EFA3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-20","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[-23.8333333,18.8333333],[-23.8333333,12.8333333],[-26.1666666,12.8333333],[-26.375,12.8333333],[-26.375,18.8333333]],"sourceHandles":["1EFD0","1EFD1","1EFD2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-21","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[-20.2916666,18.8333333],[-20.2916666,12.8333333],[-20.5,12.8333333],[-22.8333333,12.8333333],[-22.8333333,18.8333333]],"sourceHandles":["1EFCE","1EFCF","1EFD3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-22","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[-17.1666666,18.8333333],[-17.1666666,12.8333333],[-19.5,12.8333333],[-19.7083333,12.8333333],[-19.7083333,18.8333333]],"sourceHandles":["1F000","1F001","1F002"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-23","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[-13.625,18.8333333],[-13.625,12.8333333],[-13.8333333,12.8333333],[-16.1666666,12.8333333],[-16.1666666,18.8333333]],"sourceHandles":["1EFFE","1EFFF","1F003"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-24","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[-10.5,18.8333333],[-10.5,12.8333333],[-12.8333333,12.8333333],[-13.0416666,12.8333333],[-13.0416666,18.8333333]],"sourceHandles":["1F030","1F031","1F032"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-25","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[-6.9583333,18.8333333],[-6.9583333,12.8333333],[-7.1666666,12.8333333],[-9.5,12.8333333],[-9.5,18.8333333]],"sourceHandles":["1F02E","1F02F","1F033"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-26","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[-3.8333333,18.8333333],[-3.8333333,12.8333333],[-6.1666666,12.8333333],[-6.375,12.8333333],[-6.375,18.8333333]],"sourceHandles":["1F060","1F061","1F062"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-27","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[-0.2916666,18.8333333],[-0.2916666,12.8333333],[-0.5,12.8333333],[-2.8333333,12.8333333],[-2.8333333,18.8333333]],"sourceHandles":["1F05E","1F05F","1F063"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-28","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[2.8333334,18.8333333],[2.8333334,12.8333333],[0.5,12.8333333],[0.2916667,12.8333333],[0.2916667,18.8333333]],"sourceHandles":["1F090","1F091","1F092"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-29","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[6.375,18.8333333],[6.375,12.8333333],[6.1666667,12.8333333],[3.8333334,12.8333333],[3.8333334,18.8333333]],"sourceHandles":["1F08E","1F08F","1F093"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-30","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[9.5,18.8333333],[9.5,12.8333333],[7.1666667,12.8333333],[6.9583334,12.8333333],[6.9583334,18.8333333]],"sourceHandles":["1F0C0","1F0C1","1F0C2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-31","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[13.0416667,18.8333333],[13.0416667,12.8333333],[12.8333334,12.8333333],[10.5,12.8333333],[10.5,18.8333333]],"sourceHandles":["1F0BE","1F0BF","1F0C3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-32","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[16.1666667,18.8333333],[16.1666667,12.8333333],[13.8333334,12.8333333],[13.625,12.8333333],[13.625,18.8333333]],"sourceHandles":["1F0F0","1F0F1","1F0F2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-33","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[19.7083334,18.8333333],[19.7083334,12.8333333],[19.5,12.8333333],[17.1666667,12.8333333],[17.1666667,18.8333333]],"sourceHandles":["1F0EE","1F0EF","1F0F3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-34","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[22.8333334,18.8333333],[22.8333334,12.8333333],[20.5,12.8333333],[20.2916667,12.8333333],[20.2916667,18.8333333]],"sourceHandles":["1F120","1F121","1F122"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-35","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[26.375,18.8333333],[26.375,12.8333333],[26.1666667,12.8333333],[23.8333334,12.8333333],[23.8333334,18.8333333]],"sourceHandles":["1F11E","1F11F","1F123"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-36","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[29.5,18.8333333],[29.5,12.8333333],[27.1666667,12.8333333],[26.9583334,12.8333333],[26.9583334,18.8333333]],"sourceHandles":["1F150","1F151","1F152"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-37","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[33.0416667,18.8333333],[33.0416667,12.8333333],[32.8333334,12.8333333],[30.5,12.8333333],[30.5,18.8333333]],"sourceHandles":["1F14E","1F14F","1F153"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-38","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[36.1666667,18.8333333],[36.1666667,12.8333333],[33.8333334,12.8333333],[33.625,12.8333333],[33.625,18.8333333]],"sourceHandles":["1F180","1F181","1F182"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-39","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[39.7083334,18.8333333],[39.7083334,12.8333333],[39.5,12.8333333],[37.1666667,12.8333333],[37.1666667,18.8333333]],"sourceHandles":["1F17E","1F17F","1F183"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-40","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[42.8333334,18.8333333],[42.8333334,12.8333333],[40.5,12.8333333],[40.2916667,12.8333333],[40.2916667,18.8333333]],"sourceHandles":["1F1B0","1F1B1","1F1B2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-41","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[46.375,18.8333333],[46.375,12.8333333],[46.1666667,12.8333333],[43.8333334,12.8333333],[43.8333334,18.8333333]],"sourceHandles":["1F1AE","1F1AF","1F1B3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-42","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[49.5,18.8333333],[49.5,12.8333333],[47.1666667,12.8333333],[46.9583334,12.8333333],[46.9583334,18.8333333]],"sourceHandles":["1F1E0","1F1E1","1F1E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-43","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[53.0416667,18.8333333],[53.0416667,12.8333333],[52.8333334,12.8333333],[50.5,12.8333333],[50.5,18.8333333]],"sourceHandles":["1F1DE","1F1DF","1F1E3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-44","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[56.1666667,18.8333333],[56.1666667,12.8333333],[53.8333334,12.8333333],[53.625,12.8333333],[53.625,18.8333333]],"sourceHandles":["1F210","1F211","1F212"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-45","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[59.7083334,18.8333333],[59.7083334,12.8333333],[59.5,12.8333333],[57.1666667,12.8333333],[57.1666667,18.8333333]],"sourceHandles":["1F20E","1F20F","1F213"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-46","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[62.8333334,18.8333333],[62.8333334,12.8333333],[60.5,12.8333333],[60.2916667,12.8333333],[60.2916667,18.8333333]],"sourceHandles":["1F240","1F241","1F242"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-47","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[66.375,18.8333333],[66.375,12.8333333],[66.1666667,12.8333333],[63.8333334,12.8333333],[63.8333334,18.8333333]],"sourceHandles":["1F23E","1F23F","1F243"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-48","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[69.5,18.8333333],[69.5,12.8333333],[67.1666667,12.8333333],[66.9583334,12.8333333],[66.9583334,18.8333333]],"sourceHandles":["1F270","1F271","1F272"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-49","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[73.0416667,18.8333333],[73.0416667,12.8333333],[72.8333334,12.8333333],[70.5,12.8333333],[70.5,18.8333333]],"sourceHandles":["1F26E","1F26F","1F273"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-50","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[76.1666667,18.8333333],[76.1666667,12.8333333],[73.8333334,12.8333333],[73.625,12.8333333],[73.625,18.8333333]],"sourceHandles":["1F2A0","1F2A1","1F2A2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-51","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[79.7083334,18.8333333],[79.7083334,12.8333333],[79.5,12.8333333],[77.1666667,12.8333333],[77.1666667,18.8333333]],"sourceHandles":["1F29E","1F29F","1F2A3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-52","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[82.8333334,18.8333333],[82.8333334,12.8333333],[80.5,12.8333333],[80.2916667,12.8333333],[80.2916667,18.8333333]],"sourceHandles":["1F2D0","1F2D1","1F2D2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-53","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[86.375,18.8333333],[86.375,12.8333333],[86.1666667,12.8333333],[83.8333334,12.8333333],[83.8333334,18.8333333]],"sourceHandles":["1F2CE","1F2CF","1F2D3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-54","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[89.5,18.8333333],[89.5,12.8333333],[87.1666667,12.8333333],[86.9583334,12.8333333],[86.9583334,18.8333333]],"sourceHandles":["1F300","1F301","1F302"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-55","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[93.0416667,18.8333333],[93.0416667,12.8333333],[92.8333334,12.8333333],[90.5,12.8333333],[90.5,18.8333333]],"sourceHandles":["1F2FE","1F2FF","1F303"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-56","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[96.1668614,18.8333333],[96.1668614,17.5049035],[96.1668614,17.5],[96.1668614,12.8333333],[93.8333334,12.8333333],[93.625,12.8333333],[93.625,18.8333333]],"sourceHandles":["1F325","1F326","1F327"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-108-57","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[-93.625,46.8333333],[-93.625,39.5833333],[-96.1666666,39.5833333],[-96.1666666,46.8333333]],"sourceHandles":["1EDE1","1EDEF","1F399"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-0","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[-90.5,46.8333333],[-90.5,39.5833333],[-93.0416666,39.5833333],[-93.0416666,46.8333333]],"sourceHandles":["1EDE9","1EDF0","1EDF1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-1","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[-86.9583333,46.8333333],[-86.9583333,39.5833333],[-89.5,39.5833333],[-89.5,46.8333333]],"sourceHandles":["1EDEA","1EDF2","1EDF3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-2","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[-83.8333333,46.8333333],[-83.8333333,39.5833333],[-86.375,39.5833333],[-86.375,46.8333333]],"sourceHandles":["1EDF4","1EE28","1F32C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-3","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[-80.2916666,46.8333333],[-80.2916666,39.5833333],[-82.8333333,39.5833333],[-82.8333333,46.8333333]],"sourceHandles":["1EE29","1F32D","1F32E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-4","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[-77.1666666,46.8333333],[-77.1666666,39.5833333],[-79.7083333,39.5833333],[-79.7083333,46.8333333]],"sourceHandles":["1EE58","1F32F","1F330"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-5","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[-73.625,46.8333333],[-73.625,39.5833333],[-76.1666666,39.5833333],[-76.1666666,46.8333333]],"sourceHandles":["1EE59","1F331","1F332"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-6","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[-70.5,46.8333333],[-70.5,39.5833333],[-73.0416666,39.5833333],[-73.0416666,46.8333333]],"sourceHandles":["1EE88","1F333","1F334"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-7","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[-66.9583333,46.8333333],[-66.9583333,39.5833333],[-69.5,39.5833333],[-69.5,46.8333333]],"sourceHandles":["1EE89","1F335","1F336"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-8","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[-63.8333333,46.8333333],[-63.8333333,39.5833333],[-66.375,39.5833333],[-66.375,46.8333333]],"sourceHandles":["1EEB8","1F337","1F338"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-9","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[-60.2916666,46.8333333],[-60.2916666,39.5833333],[-62.8333333,39.5833333],[-62.8333333,46.8333333]],"sourceHandles":["1EEB9","1F339","1F33A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-10","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[-57.1666666,46.8333333],[-57.1666666,39.5833333],[-59.7083333,39.5833333],[-59.7083333,46.8333333]],"sourceHandles":["1EEE8","1F33B","1F33C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-11","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[-53.625,46.8333333],[-53.625,39.5833333],[-56.1666666,39.5833333],[-56.1666666,46.8333333]],"sourceHandles":["1EEE9","1F33D","1F33E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-12","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[-50.5,46.8333333],[-50.5,39.5833333],[-53.0416666,39.5833333],[-53.0416666,46.8333333]],"sourceHandles":["1EF18","1F33F","1F340"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-13","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[-46.9583333,46.8333333],[-46.9583333,39.5833333],[-49.5,39.5833333],[-49.5,46.8333333]],"sourceHandles":["1EF19","1F341","1F342"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-14","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[-43.8333333,46.8333333],[-43.8333333,39.5833333],[-46.375,39.5833333],[-46.375,46.8333333]],"sourceHandles":["1EF48","1F343","1F344"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-15","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[-40.2916666,46.8333333],[-40.2916666,39.5833333],[-42.8333333,39.5833333],[-42.8333333,46.8333333]],"sourceHandles":["1EF49","1F345","1F346"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-16","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[-37.1666666,46.8333333],[-37.1666666,39.5833333],[-39.7083333,39.5833333],[-39.7083333,46.8333333]],"sourceHandles":["1EF78","1F347","1F348"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-17","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[-33.625,46.8333333],[-33.625,39.5833333],[-36.1666666,39.5833333],[-36.1666666,46.8333333]],"sourceHandles":["1EF79","1F349","1F34A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-18","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[-30.5,46.8333333],[-30.5,39.5833333],[-33.0416666,39.5833333],[-33.0416666,46.8333333]],"sourceHandles":["1EFA8","1F34B","1F34C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-19","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[-26.9583333,46.8333333],[-26.9583333,39.5833333],[-29.5,39.5833333],[-29.5,46.8333333]],"sourceHandles":["1EFA9","1F34D","1F34E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-20","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[-23.8333333,46.8333333],[-23.8333333,39.5833333],[-26.375,39.5833333],[-26.375,46.8333333]],"sourceHandles":["1EFD8","1F34F","1F350"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-21","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[-20.2916666,46.8333333],[-20.2916666,39.5833333],[-22.8333333,39.5833333],[-22.8333333,46.8333333]],"sourceHandles":["1EFD9","1F351","1F352"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-22","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[-17.1666666,46.8333333],[-17.1666666,39.5833333],[-19.7083333,39.5833333],[-19.7083333,46.8333333]],"sourceHandles":["1F008","1F353","1F354"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-23","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[-13.625,46.8333333],[-13.625,39.5833333],[-16.1666666,39.5833333],[-16.1666666,46.8333333]],"sourceHandles":["1F009","1F355","1F356"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-24","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[-10.5,46.8333333],[-10.5,39.5833333],[-13.0416666,39.5833333],[-13.0416666,46.8333333]],"sourceHandles":["1F038","1F357","1F358"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-25","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[-6.9583333,46.8333333],[-6.9583333,39.5833333],[-9.5,39.5833333],[-9.5,46.8333333]],"sourceHandles":["1F039","1F359","1F35A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-26","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[-3.8333333,46.8333333],[-3.8333333,39.5833333],[-6.375,39.5833333],[-6.375,46.8333333]],"sourceHandles":["1F068","1F35B","1F35C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-27","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[-0.2916666,46.8333333],[-0.2916666,39.5833333],[-2.8333333,39.5833333],[-2.8333333,46.8333333]],"sourceHandles":["1F069","1F35D","1F35E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-28","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[2.8333334,46.8333333],[2.8333334,39.5833333],[0.2916667,39.5833333],[0.2916667,46.8333333]],"sourceHandles":["1F098","1F35F","1F360"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-29","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[6.375,46.8333333],[6.375,39.5833333],[3.8333334,39.5833333],[3.8333334,46.8333333]],"sourceHandles":["1F099","1F361","1F362"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-30","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[9.5,46.8333333],[9.5,39.5833333],[6.9583334,39.5833333],[6.9583334,46.8333333]],"sourceHandles":["1F0C8","1F363","1F364"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-31","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[13.0416667,46.8333333],[13.0416667,39.5833333],[10.5,39.5833333],[10.5,46.8333333]],"sourceHandles":["1F0C9","1F365","1F366"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-32","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[16.1666667,46.8333333],[16.1666667,39.5833333],[13.625,39.5833333],[13.625,46.8333333]],"sourceHandles":["1F0F8","1F367","1F368"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-33","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[19.7083334,46.8333333],[19.7083334,39.5833333],[17.1666667,39.5833333],[17.1666667,46.8333333]],"sourceHandles":["1F0F9","1F369","1F36A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-34","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[22.8333334,46.8333333],[22.8333334,39.5833333],[20.2916667,39.5833333],[20.2916667,46.8333333]],"sourceHandles":["1F128","1F36B","1F36C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-35","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[26.375,46.8333333],[26.375,39.5833333],[23.8333334,39.5833333],[23.8333334,46.8333333]],"sourceHandles":["1F129","1F36D","1F36E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-36","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[29.5,46.8333333],[29.5,39.5833333],[26.9583334,39.5833333],[26.9583334,46.8333333]],"sourceHandles":["1F158","1F36F","1F370"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-37","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[33.0416667,46.8333333],[33.0416667,39.5833333],[30.5,39.5833333],[30.5,46.8333333]],"sourceHandles":["1F159","1F371","1F372"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-38","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[36.1666667,46.8333333],[36.1666667,39.5833333],[33.625,39.5833333],[33.625,46.8333333]],"sourceHandles":["1F188","1F373","1F374"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-39","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[39.7083334,46.8333333],[39.7083334,39.5833333],[37.1666667,39.5833333],[37.1666667,46.8333333]],"sourceHandles":["1F189","1F375","1F376"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-40","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[42.8333334,46.8333333],[42.8333334,39.5833333],[40.2916667,39.5833333],[40.2916667,46.8333333]],"sourceHandles":["1F1B8","1F377","1F378"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-41","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[46.375,46.8333333],[46.375,39.5833333],[43.8333334,39.5833333],[43.8333334,46.8333333]],"sourceHandles":["1F1B9","1F379","1F37A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-42","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[49.5,46.8333333],[49.5,39.5833333],[46.9583334,39.5833333],[46.9583334,46.8333333]],"sourceHandles":["1F1E8","1F37B","1F37C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-43","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[53.0416667,46.8333333],[53.0416667,39.5833333],[50.5,39.5833333],[50.5,46.8333333]],"sourceHandles":["1F1E9","1F37D","1F37E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-44","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[56.1666667,46.8333333],[56.1666667,39.5833333],[53.625,39.5833333],[53.625,46.8333333]],"sourceHandles":["1F218","1F37F","1F380"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-45","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[59.7083334,46.8333333],[59.7083334,39.5833333],[57.1666667,39.5833333],[57.1666667,46.8333333]],"sourceHandles":["1F219","1F381","1F382"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-46","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[62.8333334,46.8333333],[62.8333334,39.5833333],[60.2916667,39.5833333],[60.2916667,46.8333333]],"sourceHandles":["1F248","1F383","1F384"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-47","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[66.375,46.8333333],[66.375,39.5833333],[63.8333334,39.5833333],[63.8333334,46.8333333]],"sourceHandles":["1F249","1F385","1F386"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-48","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[69.5,46.8333333],[69.5,39.5833333],[66.9583334,39.5833333],[66.9583334,46.8333333]],"sourceHandles":["1F278","1F387","1F388"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-49","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[73.0416667,46.8333333],[73.0416667,39.5833333],[70.5,39.5833333],[70.5,46.8333333]],"sourceHandles":["1F279","1F389","1F38A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-50","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[76.1666667,46.8333333],[76.1666667,39.5833333],[73.625,39.5833333],[73.625,46.8333333]],"sourceHandles":["1F2A8","1F38B","1F38C"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-51","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[79.7083334,46.8333333],[79.7083334,39.5833333],[77.1666667,39.5833333],[77.1666667,46.8333333]],"sourceHandles":["1F2A9","1F38D","1F38E"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-52","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[82.8333334,46.8333333],[82.8333334,39.5833333],[80.2916667,39.5833333],[80.2916667,46.8333333]],"sourceHandles":["1F2D8","1F38F","1F390"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-53","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[86.375,46.8333333],[86.375,39.5833333],[83.8333334,39.5833333],[83.8333334,46.8333333]],"sourceHandles":["1F2D9","1F391","1F392"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-54","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[89.5,46.8333333],[89.5,39.5833333],[86.9583334,39.5833333],[86.9583334,46.8333333]],"sourceHandles":["1F308","1F393","1F394"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-55","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[93.0416667,46.8333333],[93.0416667,39.5833333],[90.5,39.5833333],[90.5,46.8333333]],"sourceHandles":["1F309","1F395","1F396"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-56","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[96.1668614,46.8333333],[96.1668614,39.5833333],[93.625,39.5833333],[93.625,46.8333333]],"sourceHandles":["1F397","1F398"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-south-spandrel-110-57","tower":2,"face":"south","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":459,"columnIndex":0,"outlineFt":[[-98.375,-5.8333334],[-98.375,-0.0],[-98.375,1.25],[-98.375,17.5],[-98.375,22.1666666],[-98.375,37.5],[-98.375,49.0833333],[-96.1666666,49.0833333],[-96.1666666,37.5],[-95.9791666,37.5],[-95.9791666,22.1666666],[-96.1666666,22.1666666],[-96.1666666,17.5],[-96.1666666,1.25],[-96.1170343,-0.0],[-95.8854166,-5.8333334]],"sourceHandles":["15230","15232","15239","1523A","1523D","158F9","158FA","158FE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":459,"id":"upper-exterior-1-west-column-459","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":458,"columnIndex":1,"outlineFt":[[-94.1145833,-5.8333334],[-93.8333333,1.25],[-93.8333333,12.8333333],[-93.625,12.8333333],[-93.625,22.1666666],[-93.625,37.5],[-93.625,46.8333333],[-93.0416666,46.8333333],[-93.0416666,37.5],[-93.0416666,22.1666666],[-93.0416666,12.8333333],[-92.8333333,12.8333333],[-92.8333333,1.25],[-92.5520833,-5.8333334]],"sourceHandles":["1522A","1522B","1522E","1522F","153B2","153B3","153B6","153B7","153CA","153CB","153E3","153E4"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":458,"id":"upper-exterior-1-west-column-458","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":457,"columnIndex":2,"outlineFt":[[-90.78125,-5.8333334],[-90.5,1.25],[-90.5,12.8333333],[-90.5,22.1666666],[-90.6875,22.1666666],[-90.6875,37.5],[-90.5,37.5],[-90.5,46.8333333],[-89.5,46.8333333],[-89.5,37.5],[-89.3125,37.5],[-89.3125,22.1666666],[-89.5,22.1666666],[-89.5,12.8333333],[-89.5,1.25],[-89.21875,-5.8333334]],"sourceHandles":["1522C","1523F","15242","15243","153A2","153A3","153A8","153A9","153AA","153AB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":457,"id":"upper-exterior-1-west-column-457","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":456,"columnIndex":3,"outlineFt":[[-87.4479166,-5.8333334],[-87.1666666,1.25],[-87.1666666,12.8333333],[-86.9583333,12.8333333],[-86.9583333,22.1666666],[-86.9583333,37.5],[-86.9583333,46.8333333],[-86.375,46.8333333],[-86.375,37.5],[-86.375,22.1666666],[-86.375,12.8333333],[-86.1666666,12.8333333],[-86.1666666,1.25],[-85.8854166,-5.8333334]],"sourceHandles":["15240","15245","15248","15249","1539C","1539D","153A6","153A7","153CC","153CD","153D9","153DA"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":456,"id":"upper-exterior-1-west-column-456","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":455,"columnIndex":4,"outlineFt":[[-84.1145833,-5.8333334],[-83.8333333,1.25],[-83.8333333,12.8333333],[-83.8333333,22.1666666],[-84.0208333,22.1666666],[-84.0208333,37.5],[-83.8333333,37.5],[-83.8333333,46.8333333],[-82.8333333,46.8333333],[-82.8333333,37.5],[-82.6458333,37.5],[-82.6458333,22.1666666],[-82.8333333,22.1666666],[-82.8333333,12.8333333],[-82.8333333,1.25],[-82.5520833,-5.8333334]],"sourceHandles":["15246","1524B","1524E","1524F","153ED","153EE","153F3","153F4","153F5","153F6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":455,"id":"upper-exterior-1-west-column-455","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":454,"columnIndex":5,"outlineFt":[[-80.78125,-5.8333334],[-80.5,1.25],[-80.5,12.8333333],[-80.2916666,12.8333333],[-80.2916666,22.1666666],[-80.2916666,37.5],[-80.2916666,46.8333333],[-79.7083333,46.8333333],[-79.7083333,37.5],[-79.7083333,22.1666666],[-79.7083333,12.8333333],[-79.5,12.8333333],[-79.5,1.25],[-79.21875,-5.8333334]],"sourceHandles":["1524C","15251","15254","15255","153E9","153EA","153F1","153F2","15409","1540A","15410","15411"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":454,"id":"upper-exterior-1-west-column-454","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":453,"columnIndex":6,"outlineFt":[[-77.4479166,-5.8333334],[-77.1666666,1.25],[-77.1666666,12.8333333],[-77.1666666,22.1666666],[-77.3541666,22.1666666],[-77.3541666,37.5],[-77.1666666,37.5],[-77.1666666,46.8333333],[-76.1666666,46.8333333],[-76.1666666,37.5],[-75.9791666,37.5],[-75.9791666,22.1666666],[-76.1666666,22.1666666],[-76.1666666,12.8333333],[-76.1666666,1.25],[-75.8854166,-5.8333334]],"sourceHandles":["15252","15257","1525A","1525B","1541D","1541E","15423","15424","15425","15426"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":453,"id":"upper-exterior-1-west-column-453","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":452,"columnIndex":7,"outlineFt":[[-74.1145833,-5.8333334],[-73.8333333,1.25],[-73.8333333,12.8333333],[-73.625,12.8333333],[-73.625,22.1666666],[-73.625,37.5],[-73.625,46.8333333],[-73.0416666,46.8333333],[-73.0416666,37.5],[-73.0416666,22.1666666],[-73.0416666,12.8333333],[-72.8333333,12.8333333],[-72.8333333,1.25],[-72.5520833,-5.8333334]],"sourceHandles":["15258","1525D","15260","15261","15419","1541A","15421","15422","15439","1543A","15440","15441"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":452,"id":"upper-exterior-1-west-column-452","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":451,"columnIndex":8,"outlineFt":[[-70.78125,-5.8333334],[-70.5,1.25],[-70.5,12.8333333],[-70.5,22.1666666],[-70.6875,22.1666666],[-70.6875,37.5],[-70.5,37.5],[-70.5,46.8333333],[-69.5,46.8333333],[-69.5,37.5],[-69.3125,37.5],[-69.3125,22.1666666],[-69.5,22.1666666],[-69.5,12.8333333],[-69.5,1.25],[-69.21875,-5.8333334]],"sourceHandles":["1525E","15263","15266","15267","1544D","1544E","15453","15454","15455","15456"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":451,"id":"upper-exterior-1-west-column-451","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":450,"columnIndex":9,"outlineFt":[[-67.4479166,-5.8333334],[-67.1666666,1.25],[-67.1666666,12.8333333],[-66.9583333,12.8333333],[-66.9583333,22.1666666],[-66.9583333,37.5],[-66.9583333,46.8333333],[-66.375,46.8333333],[-66.375,37.5],[-66.375,22.1666666],[-66.375,12.8333333],[-66.1666666,12.8333333],[-66.1666666,1.25],[-65.8854166,-5.8333334]],"sourceHandles":["15264","15269","1526C","1526D","15449","1544A","15451","15452","15469","1546A","15470","15471"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":450,"id":"upper-exterior-1-west-column-450","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":449,"columnIndex":10,"outlineFt":[[-64.1145833,-5.8333334],[-63.8333333,1.25],[-63.8333333,12.8333333],[-63.8333333,22.1666666],[-64.0208333,22.1666666],[-64.0208333,37.5],[-63.8333333,37.5],[-63.8333333,46.8333333],[-62.8333333,46.8333333],[-62.8333333,37.5],[-62.6458333,37.5],[-62.6458333,22.1666666],[-62.8333333,22.1666666],[-62.8333333,12.8333333],[-62.8333333,1.25],[-62.5520833,-5.8333334]],"sourceHandles":["1526A","1526F","15272","15273","1547D","1547E","15483","15484","15485","15486"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":449,"id":"upper-exterior-1-west-column-449","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":448,"columnIndex":11,"outlineFt":[[-60.78125,-5.8333334],[-60.5,1.25],[-60.5,12.8333333],[-60.2916666,12.8333333],[-60.2916666,22.1666666],[-60.2916666,37.5],[-60.2916666,46.8333333],[-59.7083333,46.8333333],[-59.7083333,37.5],[-59.7083333,22.1666666],[-59.7083333,12.8333333],[-59.5,12.8333333],[-59.5,1.25],[-59.21875,-5.8333334]],"sourceHandles":["15270","15275","15278","15279","15479","1547A","15481","15482","15499","1549A","154A0","154A1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":448,"id":"upper-exterior-1-west-column-448","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":447,"columnIndex":12,"outlineFt":[[-57.4479166,-5.8333334],[-57.1666666,1.25],[-57.1666666,12.8333333],[-57.1666666,22.1666666],[-57.3541666,22.1666666],[-57.3541666,37.5],[-57.1666666,37.5],[-57.1666666,46.8333333],[-56.1666666,46.8333333],[-56.1666666,37.5],[-55.9791666,37.5],[-55.9791666,22.1666666],[-56.1666666,22.1666666],[-56.1666666,12.8333333],[-56.1666666,1.25],[-55.8854166,-5.8333334]],"sourceHandles":["15276","1527B","1527E","1527F","154AD","154AE","154B3","154B4","154B5","154B6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":447,"id":"upper-exterior-1-west-column-447","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":446,"columnIndex":13,"outlineFt":[[-54.1145833,-5.8333334],[-53.8333333,1.25],[-53.8333333,12.8333333],[-53.625,12.8333333],[-53.625,22.1666666],[-53.625,37.5],[-53.625,46.8333333],[-53.0416666,46.8333333],[-53.0416666,37.5],[-53.0416666,22.1666666],[-53.0416666,12.8333333],[-52.8333333,12.8333333],[-52.8333333,1.25],[-52.5520833,-5.8333334]],"sourceHandles":["1527C","15281","15284","15285","154A9","154AA","154B1","154B2","154C9","154CA","154D0","154D1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":446,"id":"upper-exterior-1-west-column-446","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":445,"columnIndex":14,"outlineFt":[[-50.78125,-5.8333334],[-50.5,1.25],[-50.5,12.8333333],[-50.5,22.1666666],[-50.6875,22.1666666],[-50.6875,37.5],[-50.5,37.5],[-50.5,46.8333333],[-49.5,46.8333333],[-49.5,37.5],[-49.3125,37.5],[-49.3125,22.1666666],[-49.5,22.1666666],[-49.5,12.8333333],[-49.5,1.25],[-49.21875,-5.8333334]],"sourceHandles":["15282","15287","1528A","1528B","154DD","154DE","154E3","154E4","154E5","154E6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":445,"id":"upper-exterior-1-west-column-445","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":444,"columnIndex":15,"outlineFt":[[-47.4479166,-5.8333334],[-47.1666666,1.25],[-47.1666666,12.8333333],[-46.9583333,12.8333333],[-46.9583333,22.1666666],[-46.9583333,37.5],[-46.9583333,46.8333333],[-46.375,46.8333333],[-46.375,37.5],[-46.375,22.1666666],[-46.375,12.8333333],[-46.1666666,12.8333333],[-46.1666666,1.25],[-45.8854166,-5.8333334]],"sourceHandles":["15288","1528D","15290","15291","154D9","154DA","154E1","154E2","154F9","154FA","15500","15501"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":444,"id":"upper-exterior-1-west-column-444","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":443,"columnIndex":16,"outlineFt":[[-44.1145833,-5.8333334],[-43.8333333,1.25],[-43.8333333,12.8333333],[-43.8333333,22.1666666],[-44.0208333,22.1666666],[-44.0208333,37.5],[-43.8333333,37.5],[-43.8333333,46.8333333],[-42.8333333,46.8333333],[-42.8333333,37.5],[-42.6458333,37.5],[-42.6458333,22.1666666],[-42.8333333,22.1666666],[-42.8333333,12.8333333],[-42.8333333,1.25],[-42.5520833,-5.8333334]],"sourceHandles":["1528E","15293","15296","15297","1550D","1550E","15513","15514","15515","15516"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":443,"id":"upper-exterior-1-west-column-443","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":442,"columnIndex":17,"outlineFt":[[-40.78125,-5.8333334],[-40.5,1.25],[-40.5,12.8333333],[-40.2916666,12.8333333],[-40.2916666,22.1666666],[-40.2916666,37.5],[-40.2916666,46.8333333],[-39.7083333,46.8333333],[-39.7083333,37.5],[-39.7083333,22.1666666],[-39.7083333,12.8333333],[-39.5,12.8333333],[-39.5,1.25],[-39.21875,-5.8333334]],"sourceHandles":["15294","15299","1529C","1529D","15509","1550A","15511","15512","15529","1552A","15530","15531"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":442,"id":"upper-exterior-1-west-column-442","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":441,"columnIndex":18,"outlineFt":[[-37.4479166,-5.8333334],[-37.1666666,1.25],[-37.1666666,12.8333333],[-37.1666666,22.1666666],[-37.3541666,22.1666666],[-37.3541666,37.5],[-37.1666666,37.5],[-37.1666666,46.8333333],[-36.1666666,46.8333333],[-36.1666666,37.5],[-35.9791666,37.5],[-35.9791666,22.1666666],[-36.1666666,22.1666666],[-36.1666666,12.8333333],[-36.1666666,1.25],[-35.8854166,-5.8333334]],"sourceHandles":["1529A","1529F","152A2","152A3","1553D","1553E","15543","15544","15545","15546"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":441,"id":"upper-exterior-1-west-column-441","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":440,"columnIndex":19,"outlineFt":[[-34.1145833,-5.8333334],[-33.8333333,1.25],[-33.8333333,12.8333333],[-33.625,12.8333333],[-33.625,22.1666666],[-33.625,37.5],[-33.625,46.8333333],[-33.0416666,46.8333333],[-33.0416666,37.5],[-33.0416666,22.1666666],[-33.0416666,12.8333333],[-32.8333333,12.8333333],[-32.8333333,1.25],[-32.5520833,-5.8333334]],"sourceHandles":["152A0","152A5","152A8","152A9","15539","1553A","15541","15542","15559","1555A","15560","15561"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":440,"id":"upper-exterior-1-west-column-440","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":439,"columnIndex":20,"outlineFt":[[-30.78125,-5.8333334],[-30.5,1.25],[-30.5,12.8333333],[-30.5,22.1666666],[-30.6875,22.1666666],[-30.6875,37.5],[-30.5,37.5],[-30.5,46.8333333],[-29.5,46.8333333],[-29.5,37.5],[-29.3125,37.5],[-29.3125,22.1666666],[-29.5,22.1666666],[-29.5,12.8333333],[-29.5,1.25],[-29.21875,-5.8333334]],"sourceHandles":["152A6","152AB","152AE","152AF","1556D","1556E","15573","15574","15575","15576"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":439,"id":"upper-exterior-1-west-column-439","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":438,"columnIndex":21,"outlineFt":[[-27.4479166,-5.8333334],[-27.1666666,1.25],[-27.1666666,12.8333333],[-26.9583333,12.8333333],[-26.9583333,22.1666666],[-26.9583333,37.5],[-26.9583333,46.8333333],[-26.375,46.8333333],[-26.375,37.5],[-26.375,22.1666666],[-26.375,12.8333333],[-26.1666666,12.8333333],[-26.1666666,1.25],[-25.8854166,-5.8333334]],"sourceHandles":["152AC","152B1","152B4","152B5","15569","1556A","15571","15572","15589","1558A","15590","15591"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":438,"id":"upper-exterior-1-west-column-438","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":437,"columnIndex":22,"outlineFt":[[-24.1145833,-5.8333334],[-23.8333333,1.25],[-23.8333333,12.8333333],[-23.8333333,22.1666666],[-24.0208333,22.1666666],[-24.0208333,37.5],[-23.8333333,37.5],[-23.8333333,46.8333333],[-22.8333333,46.8333333],[-22.8333333,37.5],[-22.6458333,37.5],[-22.6458333,22.1666666],[-22.8333333,22.1666666],[-22.8333333,12.8333333],[-22.8333333,1.25],[-22.5520833,-5.8333334]],"sourceHandles":["152B2","152B7","152BA","152BB","1559D","1559E","155A3","155A4","155A5","155A6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":437,"id":"upper-exterior-1-west-column-437","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":436,"columnIndex":23,"outlineFt":[[-20.78125,-5.8333334],[-20.5,1.25],[-20.5,12.8333333],[-20.2916666,12.8333333],[-20.2916666,22.1666666],[-20.2916666,37.5],[-20.2916666,46.8333333],[-19.7083333,46.8333333],[-19.7083333,37.5],[-19.7083333,22.1666666],[-19.7083333,12.8333333],[-19.5,12.8333333],[-19.5,1.25],[-19.21875,-5.8333334]],"sourceHandles":["152B8","152BD","152C0","152C1","15599","1559A","155A1","155A2","155B9","155BA","155C0","155C1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":436,"id":"upper-exterior-1-west-column-436","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":435,"columnIndex":24,"outlineFt":[[-17.4479166,-5.8333334],[-17.1666666,1.25],[-17.1666666,12.8333333],[-17.1666666,22.1666666],[-17.3541666,22.1666666],[-17.3541666,37.5],[-17.1666666,37.5],[-17.1666666,46.8333333],[-16.1666666,46.8333333],[-16.1666666,37.5],[-15.9791666,37.5],[-15.9791666,22.1666666],[-16.1666666,22.1666666],[-16.1666666,12.8333333],[-16.1666666,1.25],[-15.8854166,-5.8333334]],"sourceHandles":["152BE","152C3","152C6","152C7","155CD","155CE","155D3","155D4","155D5","155D6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":435,"id":"upper-exterior-1-west-column-435","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":434,"columnIndex":25,"outlineFt":[[-14.1145833,-5.8333334],[-13.8333333,1.25],[-13.8333333,12.8333333],[-13.625,12.8333333],[-13.625,22.1666666],[-13.625,37.5],[-13.625,46.8333333],[-13.0416666,46.8333333],[-13.0416666,37.5],[-13.0416666,22.1666666],[-13.0416666,12.8333333],[-12.8333333,12.8333333],[-12.8333333,1.25],[-12.5520833,-5.8333334]],"sourceHandles":["152C4","152C9","152CC","152CD","155C9","155CA","155D1","155D2","155E9","155EA","155F0","155F1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":434,"id":"upper-exterior-1-west-column-434","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":433,"columnIndex":26,"outlineFt":[[-10.78125,-5.8333334],[-10.5,1.25],[-10.5,12.8333333],[-10.5,22.1666666],[-10.6875,22.1666666],[-10.6875,37.5],[-10.5,37.5],[-10.5,46.8333333],[-9.5,46.8333333],[-9.5,37.5],[-9.3125,37.5],[-9.3125,22.1666666],[-9.5,22.1666666],[-9.5,12.8333333],[-9.5,1.25],[-9.21875,-5.8333334]],"sourceHandles":["152CA","152CF","152D2","152D3","155FD","155FE","15603","15604","15605","15606"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":433,"id":"upper-exterior-1-west-column-433","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":432,"columnIndex":27,"outlineFt":[[-7.4479166,-5.8333334],[-7.1666666,1.25],[-7.1666666,12.8333333],[-6.9583333,12.8333333],[-6.9583333,22.1666666],[-6.9583333,37.5],[-6.9583333,46.8333333],[-6.375,46.8333333],[-6.375,37.5],[-6.375,22.1666666],[-6.375,12.8333333],[-6.1666666,12.8333333],[-6.1666666,1.25],[-5.8854166,-5.8333334]],"sourceHandles":["152D0","152D5","152D8","152D9","155F9","155FA","15601","15602","15619","1561A","15620","15621"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":432,"id":"upper-exterior-1-west-column-432","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":431,"columnIndex":28,"outlineFt":[[-4.1145833,-5.8333334],[-3.8333333,1.25],[-3.8333333,12.8333333],[-3.8333333,22.1666666],[-4.0208333,22.1666666],[-4.0208333,37.5],[-3.8333333,37.5],[-3.8333333,46.8333333],[-2.8333333,46.8333333],[-2.8333333,37.5],[-2.6458333,37.5],[-2.6458333,22.1666666],[-2.8333333,22.1666666],[-2.8333333,12.8333333],[-2.8333333,1.25],[-2.5520833,-5.8333334]],"sourceHandles":["152D6","152DB","152DE","152DF","1562D","1562E","15633","15634","15635","15636"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":431,"id":"upper-exterior-1-west-column-431","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":430,"columnIndex":29,"outlineFt":[[-0.78125,-5.8333334],[-0.5,1.25],[-0.5,12.8333333],[-0.2916666,12.8333333],[-0.2916666,22.1666666],[-0.2916666,37.5],[-0.2916666,46.8333333],[0.2916667,46.8333333],[0.2916667,37.5],[0.2916667,22.1666666],[0.2916667,12.8333333],[0.5,12.8333333],[0.5,1.25],[0.78125,-5.8333334]],"sourceHandles":["152DC","152E1","152E4","152E5","15629","1562A","15631","15632","15649","1564A","15650","15651"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":430,"id":"upper-exterior-1-west-column-430","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":429,"columnIndex":30,"outlineFt":[[2.5520834,-5.8333334],[2.8333334,1.25],[2.8333334,12.8333333],[2.8333334,22.1666666],[2.6458334,22.1666666],[2.6458334,37.5],[2.8333334,37.5],[2.8333334,46.8333333],[3.8333334,46.8333333],[3.8333334,37.5],[4.0208334,37.5],[4.0208334,22.1666666],[3.8333334,22.1666666],[3.8333334,12.8333333],[3.8333334,1.25],[4.1145834,-5.8333334]],"sourceHandles":["152E2","152E7","152EA","152EB","1565D","1565E","15663","15664","15665","15666"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":429,"id":"upper-exterior-1-west-column-429","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":428,"columnIndex":31,"outlineFt":[[5.8854167,-5.8333334],[6.1666667,1.25],[6.1666667,12.8333333],[6.375,12.8333333],[6.375,22.1666666],[6.375,37.5],[6.375,46.8333333],[6.9583334,46.8333333],[6.9583334,37.5],[6.9583334,22.1666666],[6.9583334,12.8333333],[7.1666667,12.8333333],[7.1666667,1.25],[7.4479167,-5.8333334]],"sourceHandles":["152E8","152ED","152F0","152F1","15659","1565A","15661","15662","15679","1567A","15680","15681"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":428,"id":"upper-exterior-1-west-column-428","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":427,"columnIndex":32,"outlineFt":[[9.21875,-5.8333334],[9.5,1.25],[9.5,12.8333333],[9.5,22.1666666],[9.3125,22.1666666],[9.3125,37.5],[9.5,37.5],[9.5,46.8333333],[10.5,46.8333333],[10.5,37.5],[10.6875,37.5],[10.6875,22.1666666],[10.5,22.1666666],[10.5,12.8333333],[10.5,1.25],[10.78125,-5.8333334]],"sourceHandles":["152EE","152F3","152F6","152F7","1568D","1568E","15693","15694","15695","15696"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":427,"id":"upper-exterior-1-west-column-427","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":426,"columnIndex":33,"outlineFt":[[12.5520834,-5.8333334],[12.8333334,1.25],[12.8333334,12.8333333],[13.0416667,12.8333333],[13.0416667,22.1666666],[13.0416667,37.5],[13.0416667,46.8333333],[13.625,46.8333333],[13.625,37.5],[13.625,22.1666666],[13.625,12.8333333],[13.8333334,12.8333333],[13.8333334,1.25],[14.1145834,-5.8333334]],"sourceHandles":["152F4","152F9","152FC","152FD","15689","1568A","15691","15692","156A9","156AA","156B0","156B1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":426,"id":"upper-exterior-1-west-column-426","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":425,"columnIndex":34,"outlineFt":[[15.8854167,-5.8333334],[16.1666667,1.25],[16.1666667,12.8333333],[16.1666667,22.1666666],[15.9791667,22.1666666],[15.9791667,37.5],[16.1666667,37.5],[16.1666667,46.8333333],[17.1666667,46.8333333],[17.1666667,37.5],[17.3541667,37.5],[17.3541667,22.1666666],[17.1666667,22.1666666],[17.1666667,12.8333333],[17.1666667,1.25],[17.4479167,-5.8333334]],"sourceHandles":["152FA","152FF","15302","15303","156BD","156BE","156C3","156C4","156C5","156C6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":425,"id":"upper-exterior-1-west-column-425","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":424,"columnIndex":35,"outlineFt":[[19.21875,-5.8333334],[19.5,1.25],[19.5,12.8333333],[19.7083334,12.8333333],[19.7083334,22.1666666],[19.7083334,37.5],[19.7083334,46.8333333],[20.2916667,46.8333333],[20.2916667,37.5],[20.2916667,22.1666666],[20.2916667,12.8333333],[20.5,12.8333333],[20.5,1.25],[20.78125,-5.8333334]],"sourceHandles":["15300","15305","15308","15309","156B9","156BA","156C1","156C2","156D9","156DA","156E0","156E1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":424,"id":"upper-exterior-1-west-column-424","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":423,"columnIndex":36,"outlineFt":[[22.5520834,-5.8333334],[22.8333334,1.25],[22.8333334,12.8333333],[22.8333334,22.1666666],[22.6458334,22.1666666],[22.6458334,37.5],[22.8333334,37.5],[22.8333334,46.8333333],[23.8333334,46.8333333],[23.8333334,37.5],[24.0208334,37.5],[24.0208334,22.1666666],[23.8333334,22.1666666],[23.8333334,12.8333333],[23.8333334,1.25],[24.1145834,-5.8333334]],"sourceHandles":["15306","1530B","1530E","1530F","156ED","156EE","156F3","156F4","156F5","156F6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":423,"id":"upper-exterior-1-west-column-423","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":422,"columnIndex":37,"outlineFt":[[25.8854167,-5.8333334],[26.1666667,1.25],[26.1666667,12.8333333],[26.375,12.8333333],[26.375,22.1666666],[26.375,37.5],[26.375,46.8333333],[26.9583334,46.8333333],[26.9583334,37.5],[26.9583334,22.1666666],[26.9583334,12.8333333],[27.1666667,12.8333333],[27.1666667,1.25],[27.4479167,-5.8333334]],"sourceHandles":["1530C","15311","15314","15315","156E9","156EA","156F1","156F2","15709","1570A","15710","15711"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":422,"id":"upper-exterior-1-west-column-422","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":421,"columnIndex":38,"outlineFt":[[29.21875,-5.8333334],[29.5,1.25],[29.5,12.8333333],[29.5,22.1666666],[29.3125,22.1666666],[29.3125,37.5],[29.5,37.5],[29.5,46.8333333],[30.5,46.8333333],[30.5,37.5],[30.6875,37.5],[30.6875,22.1666666],[30.5,22.1666666],[30.5,12.8333333],[30.5,1.25],[30.78125,-5.8333334]],"sourceHandles":["15312","15317","1531A","1531B","1571D","1571E","15723","15724","15725","15726"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":421,"id":"upper-exterior-1-west-column-421","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":420,"columnIndex":39,"outlineFt":[[32.5520834,-5.8333334],[32.8333334,1.25],[32.8333334,12.8333333],[33.0416667,12.8333333],[33.0416667,22.1666666],[33.0416667,37.5],[33.0416667,46.8333333],[33.625,46.8333333],[33.625,37.5],[33.625,22.1666666],[33.625,12.8333333],[33.8333334,12.8333333],[33.8333334,1.25],[34.1145834,-5.8333334]],"sourceHandles":["15318","1531D","15320","15321","15719","1571A","15721","15722","15739","1573A","15740","15741"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":420,"id":"upper-exterior-1-west-column-420","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":419,"columnIndex":40,"outlineFt":[[35.8854167,-5.8333334],[36.1666667,1.25],[36.1666667,12.8333333],[36.1666667,22.1666666],[35.9791667,22.1666666],[35.9791667,37.5],[36.1666667,37.5],[36.1666667,46.8333333],[37.1666667,46.8333333],[37.1666667,37.5],[37.3541667,37.5],[37.3541667,22.1666666],[37.1666667,22.1666666],[37.1666667,12.8333333],[37.1666667,1.25],[37.4479167,-5.8333334]],"sourceHandles":["1531E","15323","15326","15327","1574D","1574E","15753","15754","15755","15756"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":419,"id":"upper-exterior-1-west-column-419","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":418,"columnIndex":41,"outlineFt":[[39.21875,-5.8333334],[39.5,1.25],[39.5,12.8333333],[39.7083334,12.8333333],[39.7083334,22.1666666],[39.7083334,37.5],[39.7083334,46.8333333],[40.2916667,46.8333333],[40.2916667,37.5],[40.2916667,22.1666666],[40.2916667,12.8333333],[40.5,12.8333333],[40.5,1.25],[40.78125,-5.8333334]],"sourceHandles":["15324","15329","1532C","1532D","15749","1574A","15751","15752","15769","1576A","15770","15771"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":418,"id":"upper-exterior-1-west-column-418","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":417,"columnIndex":42,"outlineFt":[[42.5520834,-5.8333334],[42.8333334,1.25],[42.8333334,12.8333333],[42.8333334,22.1666666],[42.6458334,22.1666666],[42.6458334,37.5],[42.8333334,37.5],[42.8333334,46.8333333],[43.8333334,46.8333333],[43.8333334,37.5],[44.0208334,37.5],[44.0208334,22.1666666],[43.8333334,22.1666666],[43.8333334,12.8333333],[43.8333334,1.25],[44.1145834,-5.8333334]],"sourceHandles":["1532A","1532F","15332","15333","1577D","1577E","15783","15784","15785","15786"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":417,"id":"upper-exterior-1-west-column-417","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":416,"columnIndex":43,"outlineFt":[[45.8854167,-5.8333334],[46.1666667,1.25],[46.1666667,12.8333333],[46.375,12.8333333],[46.375,22.1666666],[46.375,37.5],[46.375,46.8333333],[46.9583334,46.8333333],[46.9583334,37.5],[46.9583334,22.1666666],[46.9583334,12.8333333],[47.1666667,12.8333333],[47.1666667,1.25],[47.4479167,-5.8333334]],"sourceHandles":["15330","15335","15338","15339","15779","1577A","15781","15782","15799","1579A","157A0","157A1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":416,"id":"upper-exterior-1-west-column-416","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":415,"columnIndex":44,"outlineFt":[[49.21875,-5.8333334],[49.5,1.25],[49.5,12.8333333],[49.5,22.1666666],[49.3125,22.1666666],[49.3125,37.5],[49.5,37.5],[49.5,46.8333333],[50.5,46.8333333],[50.5,37.5],[50.6875,37.5],[50.6875,22.1666666],[50.5,22.1666666],[50.5,12.8333333],[50.5,1.25],[50.78125,-5.8333334]],"sourceHandles":["15336","1533B","1533E","1533F","157AD","157AE","157B3","157B4","157B5","157B6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":415,"id":"upper-exterior-1-west-column-415","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":414,"columnIndex":45,"outlineFt":[[52.5520834,-5.8333334],[52.8333334,1.25],[52.8333334,12.8333333],[53.0416667,12.8333333],[53.0416667,22.1666666],[53.0416667,37.5],[53.0416667,46.8333333],[53.625,46.8333333],[53.625,37.5],[53.625,22.1666666],[53.625,12.8333333],[53.8333334,12.8333333],[53.8333334,1.25],[54.1145834,-5.8333334]],"sourceHandles":["1533C","15341","15344","15345","157A9","157AA","157B1","157B2","157C9","157CA","157D0","157D1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":414,"id":"upper-exterior-1-west-column-414","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":413,"columnIndex":46,"outlineFt":[[55.8854167,-5.8333334],[56.1666667,1.25],[56.1666667,12.8333333],[56.1666667,22.1666666],[55.9791667,22.1666666],[55.9791667,37.5],[56.1666667,37.5],[56.1666667,46.8333333],[57.1666667,46.8333333],[57.1666667,37.5],[57.3541667,37.5],[57.3541667,22.1666666],[57.1666667,22.1666666],[57.1666667,12.8333333],[57.1666667,1.25],[57.4479167,-5.8333334]],"sourceHandles":["15342","15347","1534A","1534B","157DD","157DE","157E3","157E4","157E5","157E6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":413,"id":"upper-exterior-1-west-column-413","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":412,"columnIndex":47,"outlineFt":[[59.21875,-5.8333334],[59.5,1.25],[59.5,12.8333333],[59.7083334,12.8333333],[59.7083334,22.1666666],[59.7083334,37.5],[59.7083334,46.8333333],[60.2916667,46.8333333],[60.2916667,37.5],[60.2916667,22.1666666],[60.2916667,12.8333333],[60.5,12.8333333],[60.5,1.25],[60.78125,-5.8333334]],"sourceHandles":["15348","1534D","15350","15351","157D9","157DA","157E1","157E2","157F9","157FA","15800","15801"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":412,"id":"upper-exterior-1-west-column-412","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":411,"columnIndex":48,"outlineFt":[[62.5520834,-5.8333334],[62.8333334,1.25],[62.8333334,12.8333333],[62.8333334,22.1666666],[62.6458334,22.1666666],[62.6458334,37.5],[62.8333334,37.5],[62.8333334,46.8333333],[63.8333334,46.8333333],[63.8333334,37.5],[64.0208334,37.5],[64.0208334,22.1666666],[63.8333334,22.1666666],[63.8333334,12.8333333],[63.8333334,1.25],[64.1145834,-5.8333334]],"sourceHandles":["1534E","15353","15356","15357","1580D","1580E","15813","15814","15815","15816"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":411,"id":"upper-exterior-1-west-column-411","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":410,"columnIndex":49,"outlineFt":[[65.8854167,-5.8333334],[66.1666667,1.25],[66.1666667,12.8333333],[66.375,12.8333333],[66.375,22.1666666],[66.375,37.5],[66.375,46.8333333],[66.9583334,46.8333333],[66.9583334,37.5],[66.9583334,22.1666666],[66.9583334,12.8333333],[67.1666667,12.8333333],[67.1666667,1.25],[67.4479167,-5.8333334]],"sourceHandles":["15354","15359","1535C","1535D","15809","1580A","15811","15812","15829","1582A","15830","15831"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":410,"id":"upper-exterior-1-west-column-410","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":409,"columnIndex":50,"outlineFt":[[69.21875,-5.8333334],[69.5,1.25],[69.5,12.8333333],[69.5,22.1666666],[69.3125,22.1666666],[69.3125,37.5],[69.5,37.5],[69.5,46.8333333],[70.5,46.8333333],[70.5,37.5],[70.6875,37.5],[70.6875,22.1666666],[70.5,22.1666666],[70.5,12.8333333],[70.5,1.25],[70.78125,-5.8333334]],"sourceHandles":["1535A","1535F","15362","15363","1583D","1583E","15843","15844","15845","15846"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":409,"id":"upper-exterior-1-west-column-409","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":408,"columnIndex":51,"outlineFt":[[72.5520834,-5.8333334],[72.8333334,1.25],[72.8333334,12.8333333],[73.0416667,12.8333333],[73.0416667,22.1666666],[73.0416667,37.5],[73.0416667,46.8333333],[73.625,46.8333333],[73.625,37.5],[73.625,22.1666666],[73.625,12.8333333],[73.8333334,12.8333333],[73.8333334,1.25],[74.1145834,-5.8333334]],"sourceHandles":["15360","15365","15368","15369","15839","1583A","15841","15842","15859","1585A","15860","15861"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":408,"id":"upper-exterior-1-west-column-408","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":407,"columnIndex":52,"outlineFt":[[75.8854167,-5.8333334],[76.1666667,1.25],[76.1666667,12.8333333],[76.1666667,22.1666666],[75.9791667,22.1666666],[75.9791667,37.5],[76.1666667,37.5],[76.1666667,46.8333333],[77.1666667,46.8333333],[77.1666667,37.5],[77.3541667,37.5],[77.3541667,22.1666666],[77.1666667,22.1666666],[77.1666667,12.8333333],[77.1666667,1.25],[77.4479167,-5.8333334]],"sourceHandles":["15366","1536B","1536E","1536F","1586D","1586E","15873","15874","15875","15876"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":407,"id":"upper-exterior-1-west-column-407","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":406,"columnIndex":53,"outlineFt":[[79.21875,-5.8333334],[79.5,1.25],[79.5,12.8333333],[79.7083334,12.8333333],[79.7083334,22.1666666],[79.7083334,37.5],[79.7083334,46.8333333],[80.2916667,46.8333333],[80.2916667,37.5],[80.2916667,22.1666666],[80.2916667,12.8333333],[80.5,12.8333333],[80.5,1.25],[80.78125,-5.8333334]],"sourceHandles":["1536C","15371","15374","15375","15869","1586A","15871","15872","15889","1588A","15890","15891"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":406,"id":"upper-exterior-1-west-column-406","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":405,"columnIndex":54,"outlineFt":[[82.5520834,-5.8333334],[82.8333334,1.25],[82.8333334,12.8333333],[82.8333334,22.1666666],[82.6458334,22.1666666],[82.6458334,37.5],[82.8333334,37.5],[82.8333334,46.8333333],[83.8333334,46.8333333],[83.8333334,37.5],[84.0208334,37.5],[84.0208334,22.1666666],[83.8333334,22.1666666],[83.8333334,12.8333333],[83.8333334,1.25],[84.1145834,-5.8333334]],"sourceHandles":["15372","15377","1537A","1537B","1589D","1589E","158A3","158A4","158A5","158A6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":405,"id":"upper-exterior-1-west-column-405","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":404,"columnIndex":55,"outlineFt":[[85.8854167,-5.8333334],[86.1666667,1.25],[86.1666667,12.8333333],[86.375,12.8333333],[86.375,22.1666666],[86.375,37.5],[86.375,46.8333333],[86.9583334,46.8333333],[86.9583334,37.5],[86.9583334,22.1666666],[86.9583334,12.8333333],[87.1666667,12.8333333],[87.1666667,1.25],[87.4479167,-5.8333334]],"sourceHandles":["15378","1537D","15380","15381","15899","1589A","158A1","158A2","158B9","158BA","158C0","158C1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":404,"id":"upper-exterior-1-west-column-404","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":403,"columnIndex":56,"outlineFt":[[89.21875,-5.8333334],[89.5,1.25],[89.5,12.8333333],[89.5,22.1666666],[89.3125,22.1666666],[89.3125,37.5],[89.5,37.5],[89.5,46.8333333],[90.5,46.8333333],[90.5,37.5],[90.6875,37.5],[90.6875,22.1666666],[90.5,22.1666666],[90.5,12.8333333],[90.5,1.25],[90.78125,-5.8333334]],"sourceHandles":["1537E","15383","15386","15387","158CD","158CE","158D3","158D4","158D5","158D6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":403,"id":"upper-exterior-1-west-column-403","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":402,"columnIndex":57,"outlineFt":[[92.5520834,-5.8333334],[92.8333334,1.25],[92.8333334,12.8333333],[93.0416667,12.8333333],[93.0416667,22.1666666],[93.0416667,37.5],[93.0416667,46.8333333],[93.625,46.8333333],[93.625,37.5],[93.625,22.1666666],[93.625,12.8333333],[93.8333334,12.8333333],[93.8333334,1.25],[94.1145834,-5.8333334]],"sourceHandles":["15384","15389","1538B","1538C","158C9","158CA","158D1","158D2","158E9","158EA","158F0","158F1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":402,"id":"upper-exterior-1-west-column-402","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":401,"columnIndex":58,"outlineFt":[[95.8854167,-5.8333334],[96.1170343,-0.0],[96.1666667,1.25],[96.1668614,1.25],[96.1668614,17.5],[96.1668614,17.5049035],[96.1668614,22.1666666],[95.9791667,22.1666666],[95.9791667,37.5],[96.1668614,37.5],[96.1668614,49.0833333],[98.375,49.0833333],[98.375,37.5],[98.375,22.1666666],[98.375,17.5049035],[98.375,17.5],[98.375,1.25],[98.375,-0.0],[98.375,-5.8333334]],"sourceHandles":["1538D","1538E","1538F","15391","15393","15394","15395","158FF","15901"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":401,"id":"upper-exterior-1-west-column-401","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[-93.8333333,1.25],[-94.1145833,-5.8333334],[-95.8854166,-5.8333334],[-96.1170343,-0.0],[-96.1666666,1.25]],"sourceHandles":["15228","15229"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-0","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[-90.5,1.25],[-90.78125,-5.8333334],[-92.5520833,-5.8333334],[-92.8333333,1.25]],"sourceHandles":["15227","1522D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-1","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[-87.1666666,1.25],[-87.4479166,-5.8333334],[-89.21875,-5.8333334],[-89.5,1.25]],"sourceHandles":["1523E","15241"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-2","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[-83.8333333,1.25],[-84.1145833,-5.8333334],[-85.8854166,-5.8333334],[-86.1666666,1.25]],"sourceHandles":["15244","15247"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-3","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[-80.5,1.25],[-80.78125,-5.8333334],[-82.5520833,-5.8333334],[-82.8333333,1.25]],"sourceHandles":["1524A","1524D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-4","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[-77.1666666,1.25],[-77.4479166,-5.8333334],[-79.21875,-5.8333334],[-79.5,1.25]],"sourceHandles":["15250","15253"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-5","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[-73.8333333,1.25],[-74.1145833,-5.8333334],[-75.8854166,-5.8333334],[-76.1666666,1.25]],"sourceHandles":["15256","15259"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-6","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[-70.5,1.25],[-70.78125,-5.8333334],[-72.5520833,-5.8333334],[-72.8333333,1.25]],"sourceHandles":["1525C","1525F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-7","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[-67.1666666,1.25],[-67.4479166,-5.8333334],[-69.21875,-5.8333334],[-69.5,1.25]],"sourceHandles":["15262","15265"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-8","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[-63.8333333,1.25],[-64.1145833,-5.8333334],[-65.8854166,-5.8333334],[-66.1666666,1.25]],"sourceHandles":["15268","1526B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-9","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[-60.5,1.25],[-60.78125,-5.8333334],[-62.5520833,-5.8333334],[-62.8333333,1.25]],"sourceHandles":["1526E","15271"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-10","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[-57.1666666,1.25],[-57.4479166,-5.8333334],[-59.21875,-5.8333334],[-59.5,1.25]],"sourceHandles":["15274","15277"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-11","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[-53.8333333,1.25],[-54.1145833,-5.8333334],[-55.8854166,-5.8333334],[-56.1666666,1.25]],"sourceHandles":["1527A","1527D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-12","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[-50.5,1.25],[-50.78125,-5.8333334],[-52.5520833,-5.8333334],[-52.8333333,1.25]],"sourceHandles":["15280","15283"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-13","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[-47.1666666,1.25],[-47.4479166,-5.8333334],[-49.21875,-5.8333334],[-49.5,1.25]],"sourceHandles":["15286","15289"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-14","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[-43.8333333,1.25],[-44.1145833,-5.8333334],[-45.8854166,-5.8333334],[-46.1666666,1.25]],"sourceHandles":["1528C","1528F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-15","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[-40.5,1.25],[-40.78125,-5.8333334],[-42.5520833,-5.8333334],[-42.8333333,1.25]],"sourceHandles":["15292","15295"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-16","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[-37.1666666,1.25],[-37.4479166,-5.8333334],[-39.21875,-5.8333334],[-39.5,1.25]],"sourceHandles":["15298","1529B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-17","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[-33.8333333,1.25],[-34.1145833,-5.8333334],[-35.8854166,-5.8333334],[-36.1666666,1.25]],"sourceHandles":["1529E","152A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-18","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[-30.5,1.25],[-30.78125,-5.8333334],[-32.5520833,-5.8333334],[-32.8333333,1.25]],"sourceHandles":["152A4","152A7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-19","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[-27.1666666,1.25],[-27.4479166,-5.8333334],[-29.21875,-5.8333334],[-29.5,1.25]],"sourceHandles":["152AA","152AD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-20","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[-23.8333333,1.25],[-24.1145833,-5.8333334],[-25.8854166,-5.8333334],[-26.1666666,1.25]],"sourceHandles":["152B0","152B3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-21","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[-20.5,1.25],[-20.78125,-5.8333334],[-22.5520833,-5.8333334],[-22.8333333,1.25]],"sourceHandles":["152B6","152B9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-22","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[-17.1666666,1.25],[-17.4479166,-5.8333334],[-19.21875,-5.8333334],[-19.5,1.25]],"sourceHandles":["152BC","152BF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-23","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[-13.8333333,1.25],[-14.1145833,-5.8333334],[-15.8854166,-5.8333334],[-16.1666666,1.25]],"sourceHandles":["152C2","152C5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-24","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[-10.5,1.25],[-10.78125,-5.8333334],[-12.5520833,-5.8333334],[-12.8333333,1.25]],"sourceHandles":["152C8","152CB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-25","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[-7.1666666,1.25],[-7.4479166,-5.8333334],[-9.21875,-5.8333334],[-9.5,1.25]],"sourceHandles":["152CE","152D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-26","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[-3.8333333,1.25],[-4.1145833,-5.8333334],[-5.8854166,-5.8333334],[-6.1666666,1.25]],"sourceHandles":["152D4","152D7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-27","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[-0.5,1.25],[-0.78125,-5.8333334],[-2.5520833,-5.8333334],[-2.8333333,1.25]],"sourceHandles":["152DA","152DD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-28","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[2.8333334,1.25],[2.5520834,-5.8333334],[0.78125,-5.8333334],[0.5,1.25]],"sourceHandles":["152E0","152E3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-29","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[6.1666667,1.25],[5.8854167,-5.8333334],[4.1145834,-5.8333334],[3.8333334,1.25]],"sourceHandles":["152E6","152E9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-30","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[9.5,1.25],[9.21875,-5.8333334],[7.4479167,-5.8333334],[7.1666667,1.25]],"sourceHandles":["152EC","152EF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-31","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[12.8333334,1.25],[12.5520834,-5.8333334],[10.78125,-5.8333334],[10.5,1.25]],"sourceHandles":["152F2","152F5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-32","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[16.1666667,1.25],[15.8854167,-5.8333334],[14.1145834,-5.8333334],[13.8333334,1.25]],"sourceHandles":["152F8","152FB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-33","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[19.5,1.25],[19.21875,-5.8333334],[17.4479167,-5.8333334],[17.1666667,1.25]],"sourceHandles":["152FE","15301"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-34","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[22.8333334,1.25],[22.5520834,-5.8333334],[20.78125,-5.8333334],[20.5,1.25]],"sourceHandles":["15304","15307"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-35","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[26.1666667,1.25],[25.8854167,-5.8333334],[24.1145834,-5.8333334],[23.8333334,1.25]],"sourceHandles":["1530A","1530D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-36","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[29.5,1.25],[29.21875,-5.8333334],[27.4479167,-5.8333334],[27.1666667,1.25]],"sourceHandles":["15310","15313"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-37","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[32.8333334,1.25],[32.5520834,-5.8333334],[30.78125,-5.8333334],[30.5,1.25]],"sourceHandles":["15316","15319"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-38","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[36.1666667,1.25],[35.8854167,-5.8333334],[34.1145834,-5.8333334],[33.8333334,1.25]],"sourceHandles":["1531C","1531F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-39","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[39.5,1.25],[39.21875,-5.8333334],[37.4479167,-5.8333334],[37.1666667,1.25]],"sourceHandles":["15322","15325"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-40","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[42.8333334,1.25],[42.5520834,-5.8333334],[40.78125,-5.8333334],[40.5,1.25]],"sourceHandles":["15328","1532B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-41","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[46.1666667,1.25],[45.8854167,-5.8333334],[44.1145834,-5.8333334],[43.8333334,1.25]],"sourceHandles":["1532E","15331"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-42","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[49.5,1.25],[49.21875,-5.8333334],[47.4479167,-5.8333334],[47.1666667,1.25]],"sourceHandles":["15334","15337"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-43","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[52.8333334,1.25],[52.5520834,-5.8333334],[50.78125,-5.8333334],[50.5,1.25]],"sourceHandles":["1533A","1533D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-44","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[56.1666667,1.25],[55.8854167,-5.8333334],[54.1145834,-5.8333334],[53.8333334,1.25]],"sourceHandles":["15340","15343"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-45","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[59.5,1.25],[59.21875,-5.8333334],[57.4479167,-5.8333334],[57.1666667,1.25]],"sourceHandles":["15346","15349"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-46","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[62.8333334,1.25],[62.5520834,-5.8333334],[60.78125,-5.8333334],[60.5,1.25]],"sourceHandles":["1534C","1534F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-47","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[66.1666667,1.25],[65.8854167,-5.8333334],[64.1145834,-5.8333334],[63.8333334,1.25]],"sourceHandles":["15352","15355"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-48","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[69.5,1.25],[69.21875,-5.8333334],[67.4479167,-5.8333334],[67.1666667,1.25]],"sourceHandles":["15358","1535B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-49","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[72.8333334,1.25],[72.5520834,-5.8333334],[70.78125,-5.8333334],[70.5,1.25]],"sourceHandles":["1535E","15361"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-50","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[76.1666667,1.25],[75.8854167,-5.8333334],[74.1145834,-5.8333334],[73.8333334,1.25]],"sourceHandles":["15364","15367"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-51","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[79.5,1.25],[79.21875,-5.8333334],[77.4479167,-5.8333334],[77.1666667,1.25]],"sourceHandles":["1536A","1536D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-52","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[82.8333334,1.25],[82.5520834,-5.8333334],[80.78125,-5.8333334],[80.5,1.25]],"sourceHandles":["15370","15373"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-53","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[86.1666667,1.25],[85.8854167,-5.8333334],[84.1145834,-5.8333334],[83.8333334,1.25]],"sourceHandles":["15376","15379"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-54","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[89.5,1.25],[89.21875,-5.8333334],[87.4479167,-5.8333334],[87.1666667,1.25]],"sourceHandles":["1537C","1537F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-55","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[92.8333334,1.25],[92.5520834,-5.8333334],[90.78125,-5.8333334],[90.5,1.25]],"sourceHandles":["15382","15385"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-56","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[96.1666667,1.25],[96.1170343,-0.0],[95.8854167,-5.8333334],[94.1145834,-5.8333334],[93.8333334,1.25]],"sourceHandles":["15388","1538A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-107-57","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[-93.625,18.8333333],[-93.625,12.8333333],[-93.8333333,12.8333333],[-96.1666666,12.8333333],[-96.1666666,17.5],[-96.1666666,18.8333333]],"sourceHandles":["1539E","1539F","153BC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-0","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[-90.5,18.8333333],[-90.5,12.8333333],[-92.8333333,12.8333333],[-93.0416666,12.8333333],[-93.0416666,18.8333333]],"sourceHandles":["153BA","153BB","153BE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-1","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[-86.9583333,18.8333333],[-86.9583333,12.8333333],[-87.1666666,12.8333333],[-89.5,12.8333333],[-89.5,18.8333333]],"sourceHandles":["153B8","153B9","153BF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-2","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[-83.8333333,18.8333333],[-83.8333333,12.8333333],[-86.1666666,12.8333333],[-86.375,12.8333333],[-86.375,18.8333333]],"sourceHandles":["153FF","15400","15401"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-3","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[-80.2916666,18.8333333],[-80.2916666,12.8333333],[-80.5,12.8333333],[-82.8333333,12.8333333],[-82.8333333,18.8333333]],"sourceHandles":["153FD","153FE","15402"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-4","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[-77.1666666,18.8333333],[-77.1666666,12.8333333],[-79.5,12.8333333],[-79.7083333,12.8333333],[-79.7083333,18.8333333]],"sourceHandles":["1542F","15430","15431"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-5","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[-73.625,18.8333333],[-73.625,12.8333333],[-73.8333333,12.8333333],[-76.1666666,12.8333333],[-76.1666666,18.8333333]],"sourceHandles":["1542D","1542E","15432"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-6","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[-70.5,18.8333333],[-70.5,12.8333333],[-72.8333333,12.8333333],[-73.0416666,12.8333333],[-73.0416666,18.8333333]],"sourceHandles":["1545F","15460","15461"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-7","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[-66.9583333,18.8333333],[-66.9583333,12.8333333],[-67.1666666,12.8333333],[-69.5,12.8333333],[-69.5,18.8333333]],"sourceHandles":["1545D","1545E","15462"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-8","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[-63.8333333,18.8333333],[-63.8333333,12.8333333],[-66.1666666,12.8333333],[-66.375,12.8333333],[-66.375,18.8333333]],"sourceHandles":["1548F","15490","15491"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-9","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[-60.2916666,18.8333333],[-60.2916666,12.8333333],[-60.5,12.8333333],[-62.8333333,12.8333333],[-62.8333333,18.8333333]],"sourceHandles":["1548D","1548E","15492"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-10","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[-57.1666666,18.8333333],[-57.1666666,12.8333333],[-59.5,12.8333333],[-59.7083333,12.8333333],[-59.7083333,18.8333333]],"sourceHandles":["154BF","154C0","154C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-11","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[-53.625,18.8333333],[-53.625,12.8333333],[-53.8333333,12.8333333],[-56.1666666,12.8333333],[-56.1666666,18.8333333]],"sourceHandles":["154BD","154BE","154C2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-12","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[-50.5,18.8333333],[-50.5,12.8333333],[-52.8333333,12.8333333],[-53.0416666,12.8333333],[-53.0416666,18.8333333]],"sourceHandles":["154EF","154F0","154F1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-13","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[-46.9583333,18.8333333],[-46.9583333,12.8333333],[-47.1666666,12.8333333],[-49.5,12.8333333],[-49.5,18.8333333]],"sourceHandles":["154ED","154EE","154F2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-14","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[-43.8333333,18.8333333],[-43.8333333,12.8333333],[-46.1666666,12.8333333],[-46.375,12.8333333],[-46.375,18.8333333]],"sourceHandles":["1551F","15520","15521"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-15","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[-40.2916666,18.8333333],[-40.2916666,12.8333333],[-40.5,12.8333333],[-42.8333333,12.8333333],[-42.8333333,18.8333333]],"sourceHandles":["1551D","1551E","15522"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-16","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[-37.1666666,18.8333333],[-37.1666666,12.8333333],[-39.5,12.8333333],[-39.7083333,12.8333333],[-39.7083333,18.8333333]],"sourceHandles":["1554F","15550","15551"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-17","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[-33.625,18.8333333],[-33.625,12.8333333],[-33.8333333,12.8333333],[-36.1666666,12.8333333],[-36.1666666,18.8333333]],"sourceHandles":["1554D","1554E","15552"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-18","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[-30.5,18.8333333],[-30.5,12.8333333],[-32.8333333,12.8333333],[-33.0416666,12.8333333],[-33.0416666,18.8333333]],"sourceHandles":["1557F","15580","15581"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-19","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[-26.9583333,18.8333333],[-26.9583333,12.8333333],[-27.1666666,12.8333333],[-29.5,12.8333333],[-29.5,18.8333333]],"sourceHandles":["1557D","1557E","15582"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-20","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[-23.8333333,18.8333333],[-23.8333333,12.8333333],[-26.1666666,12.8333333],[-26.375,12.8333333],[-26.375,18.8333333]],"sourceHandles":["155AF","155B0","155B1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-21","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[-20.2916666,18.8333333],[-20.2916666,12.8333333],[-20.5,12.8333333],[-22.8333333,12.8333333],[-22.8333333,18.8333333]],"sourceHandles":["155AD","155AE","155B2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-22","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[-17.1666666,18.8333333],[-17.1666666,12.8333333],[-19.5,12.8333333],[-19.7083333,12.8333333],[-19.7083333,18.8333333]],"sourceHandles":["155DF","155E0","155E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-23","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[-13.625,18.8333333],[-13.625,12.8333333],[-13.8333333,12.8333333],[-16.1666666,12.8333333],[-16.1666666,18.8333333]],"sourceHandles":["155DD","155DE","155E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-24","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[-10.5,18.8333333],[-10.5,12.8333333],[-12.8333333,12.8333333],[-13.0416666,12.8333333],[-13.0416666,18.8333333]],"sourceHandles":["1560F","15610","15611"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-25","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[-6.9583333,18.8333333],[-6.9583333,12.8333333],[-7.1666666,12.8333333],[-9.5,12.8333333],[-9.5,18.8333333]],"sourceHandles":["1560D","1560E","15612"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-26","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[-3.8333333,18.8333333],[-3.8333333,12.8333333],[-6.1666666,12.8333333],[-6.375,12.8333333],[-6.375,18.8333333]],"sourceHandles":["1563F","15640","15641"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-27","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[-0.2916666,18.8333333],[-0.2916666,12.8333333],[-0.5,12.8333333],[-2.8333333,12.8333333],[-2.8333333,18.8333333]],"sourceHandles":["1563D","1563E","15642"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-28","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[2.8333334,18.8333333],[2.8333334,12.8333333],[0.5,12.8333333],[0.2916667,12.8333333],[0.2916667,18.8333333]],"sourceHandles":["1566F","15670","15671"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-29","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[6.375,18.8333333],[6.375,12.8333333],[6.1666667,12.8333333],[3.8333334,12.8333333],[3.8333334,18.8333333]],"sourceHandles":["1566D","1566E","15672"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-30","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[9.5,18.8333333],[9.5,12.8333333],[7.1666667,12.8333333],[6.9583334,12.8333333],[6.9583334,18.8333333]],"sourceHandles":["1569F","156A0","156A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-31","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[13.0416667,18.8333333],[13.0416667,12.8333333],[12.8333334,12.8333333],[10.5,12.8333333],[10.5,18.8333333]],"sourceHandles":["1569D","1569E","156A2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-32","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[16.1666667,18.8333333],[16.1666667,12.8333333],[13.8333334,12.8333333],[13.625,12.8333333],[13.625,18.8333333]],"sourceHandles":["156CF","156D0","156D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-33","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[19.7083334,18.8333333],[19.7083334,12.8333333],[19.5,12.8333333],[17.1666667,12.8333333],[17.1666667,18.8333333]],"sourceHandles":["156CD","156CE","156D2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-34","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[22.8333334,18.8333333],[22.8333334,12.8333333],[20.5,12.8333333],[20.2916667,12.8333333],[20.2916667,18.8333333]],"sourceHandles":["156FF","15700","15701"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-35","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[26.375,18.8333333],[26.375,12.8333333],[26.1666667,12.8333333],[23.8333334,12.8333333],[23.8333334,18.8333333]],"sourceHandles":["156FD","156FE","15702"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-36","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[29.5,18.8333333],[29.5,12.8333333],[27.1666667,12.8333333],[26.9583334,12.8333333],[26.9583334,18.8333333]],"sourceHandles":["1572F","15730","15731"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-37","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[33.0416667,18.8333333],[33.0416667,12.8333333],[32.8333334,12.8333333],[30.5,12.8333333],[30.5,18.8333333]],"sourceHandles":["1572D","1572E","15732"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-38","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[36.1666667,18.8333333],[36.1666667,12.8333333],[33.8333334,12.8333333],[33.625,12.8333333],[33.625,18.8333333]],"sourceHandles":["1575F","15760","15761"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-39","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[39.7083334,18.8333333],[39.7083334,12.8333333],[39.5,12.8333333],[37.1666667,12.8333333],[37.1666667,18.8333333]],"sourceHandles":["1575D","1575E","15762"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-40","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[42.8333334,18.8333333],[42.8333334,12.8333333],[40.5,12.8333333],[40.2916667,12.8333333],[40.2916667,18.8333333]],"sourceHandles":["1578F","15790","15791"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-41","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[46.375,18.8333333],[46.375,12.8333333],[46.1666667,12.8333333],[43.8333334,12.8333333],[43.8333334,18.8333333]],"sourceHandles":["1578D","1578E","15792"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-42","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[49.5,18.8333333],[49.5,12.8333333],[47.1666667,12.8333333],[46.9583334,12.8333333],[46.9583334,18.8333333]],"sourceHandles":["157BF","157C0","157C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-43","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[53.0416667,18.8333333],[53.0416667,12.8333333],[52.8333334,12.8333333],[50.5,12.8333333],[50.5,18.8333333]],"sourceHandles":["157BD","157BE","157C2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-44","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[56.1666667,18.8333333],[56.1666667,12.8333333],[53.8333334,12.8333333],[53.625,12.8333333],[53.625,18.8333333]],"sourceHandles":["157EF","157F0","157F1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-45","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[59.7083334,18.8333333],[59.7083334,12.8333333],[59.5,12.8333333],[57.1666667,12.8333333],[57.1666667,18.8333333]],"sourceHandles":["157ED","157EE","157F2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-46","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[62.8333334,18.8333333],[62.8333334,12.8333333],[60.5,12.8333333],[60.2916667,12.8333333],[60.2916667,18.8333333]],"sourceHandles":["1581F","15820","15821"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-47","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[66.375,18.8333333],[66.375,12.8333333],[66.1666667,12.8333333],[63.8333334,12.8333333],[63.8333334,18.8333333]],"sourceHandles":["1581D","1581E","15822"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-48","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[69.5,18.8333333],[69.5,12.8333333],[67.1666667,12.8333333],[66.9583334,12.8333333],[66.9583334,18.8333333]],"sourceHandles":["1584F","15850","15851"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-49","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[73.0416667,18.8333333],[73.0416667,12.8333333],[72.8333334,12.8333333],[70.5,12.8333333],[70.5,18.8333333]],"sourceHandles":["1584D","1584E","15852"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-50","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[76.1666667,18.8333333],[76.1666667,12.8333333],[73.8333334,12.8333333],[73.625,12.8333333],[73.625,18.8333333]],"sourceHandles":["1587F","15880","15881"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-51","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[79.7083334,18.8333333],[79.7083334,12.8333333],[79.5,12.8333333],[77.1666667,12.8333333],[77.1666667,18.8333333]],"sourceHandles":["1587D","1587E","15882"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-52","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[82.8333334,18.8333333],[82.8333334,12.8333333],[80.5,12.8333333],[80.2916667,12.8333333],[80.2916667,18.8333333]],"sourceHandles":["158AF","158B0","158B1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-53","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[86.375,18.8333333],[86.375,12.8333333],[86.1666667,12.8333333],[83.8333334,12.8333333],[83.8333334,18.8333333]],"sourceHandles":["158AD","158AE","158B2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-54","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[89.5,18.8333333],[89.5,12.8333333],[87.1666667,12.8333333],[86.9583334,12.8333333],[86.9583334,18.8333333]],"sourceHandles":["158DF","158E0","158E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-55","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[93.0416667,18.8333333],[93.0416667,12.8333333],[92.8333334,12.8333333],[90.5,12.8333333],[90.5,18.8333333]],"sourceHandles":["158DD","158DE","158E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-56","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[96.1668614,18.8333333],[96.1668614,17.5049035],[96.1668614,17.5],[96.1668614,12.8333333],[93.8333334,12.8333333],[93.625,12.8333333],[93.625,18.8333333]],"sourceHandles":["15904","15905","15906"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-108-57","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[-93.625,46.8333333],[-93.625,39.5833333],[-96.1666666,39.5833333],[-96.1666666,46.8333333]],"sourceHandles":["153C0","153CE","15978"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-0","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[-90.5,46.8333333],[-90.5,39.5833333],[-93.0416666,39.5833333],[-93.0416666,46.8333333]],"sourceHandles":["153C8","153CF","153D0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-1","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[-86.9583333,46.8333333],[-86.9583333,39.5833333],[-89.5,39.5833333],[-89.5,46.8333333]],"sourceHandles":["153C9","153D1","153D2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-2","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[-83.8333333,46.8333333],[-83.8333333,39.5833333],[-86.375,39.5833333],[-86.375,46.8333333]],"sourceHandles":["153D3","15407","1590B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-3","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[-80.2916666,46.8333333],[-80.2916666,39.5833333],[-82.8333333,39.5833333],[-82.8333333,46.8333333]],"sourceHandles":["15408","1590C","1590D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-4","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[-77.1666666,46.8333333],[-77.1666666,39.5833333],[-79.7083333,39.5833333],[-79.7083333,46.8333333]],"sourceHandles":["15437","1590E","1590F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-5","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[-73.625,46.8333333],[-73.625,39.5833333],[-76.1666666,39.5833333],[-76.1666666,46.8333333]],"sourceHandles":["15438","15910","15911"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-6","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[-70.5,46.8333333],[-70.5,39.5833333],[-73.0416666,39.5833333],[-73.0416666,46.8333333]],"sourceHandles":["15467","15912","15913"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-7","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[-66.9583333,46.8333333],[-66.9583333,39.5833333],[-69.5,39.5833333],[-69.5,46.8333333]],"sourceHandles":["15468","15914","15915"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-8","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[-63.8333333,46.8333333],[-63.8333333,39.5833333],[-66.375,39.5833333],[-66.375,46.8333333]],"sourceHandles":["15497","15916","15917"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-9","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[-60.2916666,46.8333333],[-60.2916666,39.5833333],[-62.8333333,39.5833333],[-62.8333333,46.8333333]],"sourceHandles":["15498","15918","15919"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-10","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[-57.1666666,46.8333333],[-57.1666666,39.5833333],[-59.7083333,39.5833333],[-59.7083333,46.8333333]],"sourceHandles":["154C7","1591A","1591B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-11","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[-53.625,46.8333333],[-53.625,39.5833333],[-56.1666666,39.5833333],[-56.1666666,46.8333333]],"sourceHandles":["154C8","1591C","1591D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-12","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[-50.5,46.8333333],[-50.5,39.5833333],[-53.0416666,39.5833333],[-53.0416666,46.8333333]],"sourceHandles":["154F7","1591E","1591F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-13","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[-46.9583333,46.8333333],[-46.9583333,39.5833333],[-49.5,39.5833333],[-49.5,46.8333333]],"sourceHandles":["154F8","15920","15921"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-14","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[-43.8333333,46.8333333],[-43.8333333,39.5833333],[-46.375,39.5833333],[-46.375,46.8333333]],"sourceHandles":["15527","15922","15923"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-15","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[-40.2916666,46.8333333],[-40.2916666,39.5833333],[-42.8333333,39.5833333],[-42.8333333,46.8333333]],"sourceHandles":["15528","15924","15925"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-16","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[-37.1666666,46.8333333],[-37.1666666,39.5833333],[-39.7083333,39.5833333],[-39.7083333,46.8333333]],"sourceHandles":["15557","15926","15927"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-17","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[-33.625,46.8333333],[-33.625,39.5833333],[-36.1666666,39.5833333],[-36.1666666,46.8333333]],"sourceHandles":["15558","15928","15929"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-18","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[-30.5,46.8333333],[-30.5,39.5833333],[-33.0416666,39.5833333],[-33.0416666,46.8333333]],"sourceHandles":["15587","1592A","1592B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-19","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[-26.9583333,46.8333333],[-26.9583333,39.5833333],[-29.5,39.5833333],[-29.5,46.8333333]],"sourceHandles":["15588","1592C","1592D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-20","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[-23.8333333,46.8333333],[-23.8333333,39.5833333],[-26.375,39.5833333],[-26.375,46.8333333]],"sourceHandles":["155B7","1592E","1592F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-21","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[-20.2916666,46.8333333],[-20.2916666,39.5833333],[-22.8333333,39.5833333],[-22.8333333,46.8333333]],"sourceHandles":["155B8","15930","15931"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-22","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[-17.1666666,46.8333333],[-17.1666666,39.5833333],[-19.7083333,39.5833333],[-19.7083333,46.8333333]],"sourceHandles":["155E7","15932","15933"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-23","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[-13.625,46.8333333],[-13.625,39.5833333],[-16.1666666,39.5833333],[-16.1666666,46.8333333]],"sourceHandles":["155E8","15934","15935"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-24","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[-10.5,46.8333333],[-10.5,39.5833333],[-13.0416666,39.5833333],[-13.0416666,46.8333333]],"sourceHandles":["15617","15936","15937"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-25","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[-6.9583333,46.8333333],[-6.9583333,39.5833333],[-9.5,39.5833333],[-9.5,46.8333333]],"sourceHandles":["15618","15938","15939"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-26","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[-3.8333333,46.8333333],[-3.8333333,39.5833333],[-6.375,39.5833333],[-6.375,46.8333333]],"sourceHandles":["15647","1593A","1593B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-27","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[-0.2916666,46.8333333],[-0.2916666,39.5833333],[-2.8333333,39.5833333],[-2.8333333,46.8333333]],"sourceHandles":["15648","1593C","1593D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-28","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[2.8333334,46.8333333],[2.8333334,39.5833333],[0.2916667,39.5833333],[0.2916667,46.8333333]],"sourceHandles":["15677","1593E","1593F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-29","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[6.375,46.8333333],[6.375,39.5833333],[3.8333334,39.5833333],[3.8333334,46.8333333]],"sourceHandles":["15678","15940","15941"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-30","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[9.5,46.8333333],[9.5,39.5833333],[6.9583334,39.5833333],[6.9583334,46.8333333]],"sourceHandles":["156A7","15942","15943"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-31","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[13.0416667,46.8333333],[13.0416667,39.5833333],[10.5,39.5833333],[10.5,46.8333333]],"sourceHandles":["156A8","15944","15945"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-32","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[16.1666667,46.8333333],[16.1666667,39.5833333],[13.625,39.5833333],[13.625,46.8333333]],"sourceHandles":["156D7","15946","15947"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-33","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[19.7083334,46.8333333],[19.7083334,39.5833333],[17.1666667,39.5833333],[17.1666667,46.8333333]],"sourceHandles":["156D8","15948","15949"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-34","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[22.8333334,46.8333333],[22.8333334,39.5833333],[20.2916667,39.5833333],[20.2916667,46.8333333]],"sourceHandles":["15707","1594A","1594B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-35","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[26.375,46.8333333],[26.375,39.5833333],[23.8333334,39.5833333],[23.8333334,46.8333333]],"sourceHandles":["15708","1594C","1594D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-36","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[29.5,46.8333333],[29.5,39.5833333],[26.9583334,39.5833333],[26.9583334,46.8333333]],"sourceHandles":["15737","1594E","1594F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-37","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[33.0416667,46.8333333],[33.0416667,39.5833333],[30.5,39.5833333],[30.5,46.8333333]],"sourceHandles":["15738","15950","15951"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-38","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[36.1666667,46.8333333],[36.1666667,39.5833333],[33.625,39.5833333],[33.625,46.8333333]],"sourceHandles":["15767","15952","15953"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-39","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[39.7083334,46.8333333],[39.7083334,39.5833333],[37.1666667,39.5833333],[37.1666667,46.8333333]],"sourceHandles":["15768","15954","15955"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-40","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[42.8333334,46.8333333],[42.8333334,39.5833333],[40.2916667,39.5833333],[40.2916667,46.8333333]],"sourceHandles":["15797","15956","15957"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-41","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[46.375,46.8333333],[46.375,39.5833333],[43.8333334,39.5833333],[43.8333334,46.8333333]],"sourceHandles":["15798","15958","15959"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-42","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[49.5,46.8333333],[49.5,39.5833333],[46.9583334,39.5833333],[46.9583334,46.8333333]],"sourceHandles":["157C7","1595A","1595B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-43","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[53.0416667,46.8333333],[53.0416667,39.5833333],[50.5,39.5833333],[50.5,46.8333333]],"sourceHandles":["157C8","1595C","1595D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-44","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[56.1666667,46.8333333],[56.1666667,39.5833333],[53.625,39.5833333],[53.625,46.8333333]],"sourceHandles":["157F7","1595E","1595F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-45","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[59.7083334,46.8333333],[59.7083334,39.5833333],[57.1666667,39.5833333],[57.1666667,46.8333333]],"sourceHandles":["157F8","15960","15961"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-46","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[62.8333334,46.8333333],[62.8333334,39.5833333],[60.2916667,39.5833333],[60.2916667,46.8333333]],"sourceHandles":["15827","15962","15963"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-47","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[66.375,46.8333333],[66.375,39.5833333],[63.8333334,39.5833333],[63.8333334,46.8333333]],"sourceHandles":["15828","15964","15965"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-48","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[69.5,46.8333333],[69.5,39.5833333],[66.9583334,39.5833333],[66.9583334,46.8333333]],"sourceHandles":["15857","15966","15967"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-49","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[73.0416667,46.8333333],[73.0416667,39.5833333],[70.5,39.5833333],[70.5,46.8333333]],"sourceHandles":["15858","15968","15969"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-50","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[76.1666667,46.8333333],[76.1666667,39.5833333],[73.625,39.5833333],[73.625,46.8333333]],"sourceHandles":["15887","1596A","1596B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-51","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[79.7083334,46.8333333],[79.7083334,39.5833333],[77.1666667,39.5833333],[77.1666667,46.8333333]],"sourceHandles":["15888","1596C","1596D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-52","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[82.8333334,46.8333333],[82.8333334,39.5833333],[80.2916667,39.5833333],[80.2916667,46.8333333]],"sourceHandles":["158B7","1596E","1596F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-53","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[86.375,46.8333333],[86.375,39.5833333],[83.8333334,39.5833333],[83.8333334,46.8333333]],"sourceHandles":["158B8","15970","15971"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-54","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[89.5,46.8333333],[89.5,39.5833333],[86.9583334,39.5833333],[86.9583334,46.8333333]],"sourceHandles":["158E7","15972","15973"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-55","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[93.0416667,46.8333333],[93.0416667,39.5833333],[90.5,39.5833333],[90.5,46.8333333]],"sourceHandles":["158E8","15974","15975"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-56","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[96.1668614,46.8333333],[96.1668614,39.5833333],[93.625,39.5833333],[93.625,46.8333333]],"sourceHandles":["15976","15977"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-1-west-spandrel-110-57","tower":1,"face":"west","depthFt":null,"render":true,"scope":"WTC1 CAD elevation trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"direct WTC1 forensic elevation drawing"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":159,"columnIndex":0,"outlineFt":[[-98.375,-5.8333334],[-98.375,-0.0],[-98.375,1.25],[-98.375,17.5],[-98.375,22.1666666],[-98.375,37.5],[-98.375,49.0833333],[-96.1666666,49.0833333],[-96.1666666,37.5],[-95.9791666,37.5],[-95.9791666,22.1666666],[-96.1666666,22.1666666],[-96.1666666,17.5],[-96.1666666,1.25],[-96.1170343,-0.0],[-95.8854166,-5.8333334]],"sourceHandles":["15230","15232","15239","1523A","1523D","158F9","158FA","158FE"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":459,"id":"upper-exterior-2-west-column-159","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":158,"columnIndex":1,"outlineFt":[[-94.1145833,-5.8333334],[-93.8333333,1.25],[-93.8333333,12.8333333],[-93.625,12.8333333],[-93.625,22.1666666],[-93.625,37.5],[-93.625,46.8333333],[-93.0416666,46.8333333],[-93.0416666,37.5],[-93.0416666,22.1666666],[-93.0416666,12.8333333],[-92.8333333,12.8333333],[-92.8333333,1.25],[-92.5520833,-5.8333334]],"sourceHandles":["1522A","1522B","1522E","1522F","153B2","153B3","153B6","153B7","153CA","153CB","153E3","153E4"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":458,"id":"upper-exterior-2-west-column-158","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":157,"columnIndex":2,"outlineFt":[[-90.78125,-5.8333334],[-90.5,1.25],[-90.5,12.8333333],[-90.5,22.1666666],[-90.6875,22.1666666],[-90.6875,37.5],[-90.5,37.5],[-90.5,46.8333333],[-89.5,46.8333333],[-89.5,37.5],[-89.3125,37.5],[-89.3125,22.1666666],[-89.5,22.1666666],[-89.5,12.8333333],[-89.5,1.25],[-89.21875,-5.8333334]],"sourceHandles":["1522C","1523F","15242","15243","153A2","153A3","153A8","153A9","153AA","153AB"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":457,"id":"upper-exterior-2-west-column-157","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":156,"columnIndex":3,"outlineFt":[[-87.4479166,-5.8333334],[-87.1666666,1.25],[-87.1666666,12.8333333],[-86.9583333,12.8333333],[-86.9583333,22.1666666],[-86.9583333,37.5],[-86.9583333,46.8333333],[-86.375,46.8333333],[-86.375,37.5],[-86.375,22.1666666],[-86.375,12.8333333],[-86.1666666,12.8333333],[-86.1666666,1.25],[-85.8854166,-5.8333334]],"sourceHandles":["15240","15245","15248","15249","1539C","1539D","153A6","153A7","153CC","153CD","153D9","153DA"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":456,"id":"upper-exterior-2-west-column-156","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":155,"columnIndex":4,"outlineFt":[[-84.1145833,-5.8333334],[-83.8333333,1.25],[-83.8333333,12.8333333],[-83.8333333,22.1666666],[-84.0208333,22.1666666],[-84.0208333,37.5],[-83.8333333,37.5],[-83.8333333,46.8333333],[-82.8333333,46.8333333],[-82.8333333,37.5],[-82.6458333,37.5],[-82.6458333,22.1666666],[-82.8333333,22.1666666],[-82.8333333,12.8333333],[-82.8333333,1.25],[-82.5520833,-5.8333334]],"sourceHandles":["15246","1524B","1524E","1524F","153ED","153EE","153F3","153F4","153F5","153F6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":455,"id":"upper-exterior-2-west-column-155","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":154,"columnIndex":5,"outlineFt":[[-80.78125,-5.8333334],[-80.5,1.25],[-80.5,12.8333333],[-80.2916666,12.8333333],[-80.2916666,22.1666666],[-80.2916666,37.5],[-80.2916666,46.8333333],[-79.7083333,46.8333333],[-79.7083333,37.5],[-79.7083333,22.1666666],[-79.7083333,12.8333333],[-79.5,12.8333333],[-79.5,1.25],[-79.21875,-5.8333334]],"sourceHandles":["1524C","15251","15254","15255","153E9","153EA","153F1","153F2","15409","1540A","15410","15411"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":454,"id":"upper-exterior-2-west-column-154","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":153,"columnIndex":6,"outlineFt":[[-77.4479166,-5.8333334],[-77.1666666,1.25],[-77.1666666,12.8333333],[-77.1666666,22.1666666],[-77.3541666,22.1666666],[-77.3541666,37.5],[-77.1666666,37.5],[-77.1666666,46.8333333],[-76.1666666,46.8333333],[-76.1666666,37.5],[-75.9791666,37.5],[-75.9791666,22.1666666],[-76.1666666,22.1666666],[-76.1666666,12.8333333],[-76.1666666,1.25],[-75.8854166,-5.8333334]],"sourceHandles":["15252","15257","1525A","1525B","1541D","1541E","15423","15424","15425","15426"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":453,"id":"upper-exterior-2-west-column-153","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":152,"columnIndex":7,"outlineFt":[[-74.1145833,-5.8333334],[-73.8333333,1.25],[-73.8333333,12.8333333],[-73.625,12.8333333],[-73.625,22.1666666],[-73.625,37.5],[-73.625,46.8333333],[-73.0416666,46.8333333],[-73.0416666,37.5],[-73.0416666,22.1666666],[-73.0416666,12.8333333],[-72.8333333,12.8333333],[-72.8333333,1.25],[-72.5520833,-5.8333334]],"sourceHandles":["15258","1525D","15260","15261","15419","1541A","15421","15422","15439","1543A","15440","15441"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":452,"id":"upper-exterior-2-west-column-152","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":151,"columnIndex":8,"outlineFt":[[-70.78125,-5.8333334],[-70.5,1.25],[-70.5,12.8333333],[-70.5,22.1666666],[-70.6875,22.1666666],[-70.6875,37.5],[-70.5,37.5],[-70.5,46.8333333],[-69.5,46.8333333],[-69.5,37.5],[-69.3125,37.5],[-69.3125,22.1666666],[-69.5,22.1666666],[-69.5,12.8333333],[-69.5,1.25],[-69.21875,-5.8333334]],"sourceHandles":["1525E","15263","15266","15267","1544D","1544E","15453","15454","15455","15456"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":451,"id":"upper-exterior-2-west-column-151","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":150,"columnIndex":9,"outlineFt":[[-67.4479166,-5.8333334],[-67.1666666,1.25],[-67.1666666,12.8333333],[-66.9583333,12.8333333],[-66.9583333,22.1666666],[-66.9583333,37.5],[-66.9583333,46.8333333],[-66.375,46.8333333],[-66.375,37.5],[-66.375,22.1666666],[-66.375,12.8333333],[-66.1666666,12.8333333],[-66.1666666,1.25],[-65.8854166,-5.8333334]],"sourceHandles":["15264","15269","1526C","1526D","15449","1544A","15451","15452","15469","1546A","15470","15471"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":450,"id":"upper-exterior-2-west-column-150","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":149,"columnIndex":10,"outlineFt":[[-64.1145833,-5.8333334],[-63.8333333,1.25],[-63.8333333,12.8333333],[-63.8333333,22.1666666],[-64.0208333,22.1666666],[-64.0208333,37.5],[-63.8333333,37.5],[-63.8333333,46.8333333],[-62.8333333,46.8333333],[-62.8333333,37.5],[-62.6458333,37.5],[-62.6458333,22.1666666],[-62.8333333,22.1666666],[-62.8333333,12.8333333],[-62.8333333,1.25],[-62.5520833,-5.8333334]],"sourceHandles":["1526A","1526F","15272","15273","1547D","1547E","15483","15484","15485","15486"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":449,"id":"upper-exterior-2-west-column-149","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":148,"columnIndex":11,"outlineFt":[[-60.78125,-5.8333334],[-60.5,1.25],[-60.5,12.8333333],[-60.2916666,12.8333333],[-60.2916666,22.1666666],[-60.2916666,37.5],[-60.2916666,46.8333333],[-59.7083333,46.8333333],[-59.7083333,37.5],[-59.7083333,22.1666666],[-59.7083333,12.8333333],[-59.5,12.8333333],[-59.5,1.25],[-59.21875,-5.8333334]],"sourceHandles":["15270","15275","15278","15279","15479","1547A","15481","15482","15499","1549A","154A0","154A1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":448,"id":"upper-exterior-2-west-column-148","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":147,"columnIndex":12,"outlineFt":[[-57.4479166,-5.8333334],[-57.1666666,1.25],[-57.1666666,12.8333333],[-57.1666666,22.1666666],[-57.3541666,22.1666666],[-57.3541666,37.5],[-57.1666666,37.5],[-57.1666666,46.8333333],[-56.1666666,46.8333333],[-56.1666666,37.5],[-55.9791666,37.5],[-55.9791666,22.1666666],[-56.1666666,22.1666666],[-56.1666666,12.8333333],[-56.1666666,1.25],[-55.8854166,-5.8333334]],"sourceHandles":["15276","1527B","1527E","1527F","154AD","154AE","154B3","154B4","154B5","154B6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":447,"id":"upper-exterior-2-west-column-147","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":146,"columnIndex":13,"outlineFt":[[-54.1145833,-5.8333334],[-53.8333333,1.25],[-53.8333333,12.8333333],[-53.625,12.8333333],[-53.625,22.1666666],[-53.625,37.5],[-53.625,46.8333333],[-53.0416666,46.8333333],[-53.0416666,37.5],[-53.0416666,22.1666666],[-53.0416666,12.8333333],[-52.8333333,12.8333333],[-52.8333333,1.25],[-52.5520833,-5.8333334]],"sourceHandles":["1527C","15281","15284","15285","154A9","154AA","154B1","154B2","154C9","154CA","154D0","154D1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":446,"id":"upper-exterior-2-west-column-146","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":145,"columnIndex":14,"outlineFt":[[-50.78125,-5.8333334],[-50.5,1.25],[-50.5,12.8333333],[-50.5,22.1666666],[-50.6875,22.1666666],[-50.6875,37.5],[-50.5,37.5],[-50.5,46.8333333],[-49.5,46.8333333],[-49.5,37.5],[-49.3125,37.5],[-49.3125,22.1666666],[-49.5,22.1666666],[-49.5,12.8333333],[-49.5,1.25],[-49.21875,-5.8333334]],"sourceHandles":["15282","15287","1528A","1528B","154DD","154DE","154E3","154E4","154E5","154E6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":445,"id":"upper-exterior-2-west-column-145","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":144,"columnIndex":15,"outlineFt":[[-47.4479166,-5.8333334],[-47.1666666,1.25],[-47.1666666,12.8333333],[-46.9583333,12.8333333],[-46.9583333,22.1666666],[-46.9583333,37.5],[-46.9583333,46.8333333],[-46.375,46.8333333],[-46.375,37.5],[-46.375,22.1666666],[-46.375,12.8333333],[-46.1666666,12.8333333],[-46.1666666,1.25],[-45.8854166,-5.8333334]],"sourceHandles":["15288","1528D","15290","15291","154D9","154DA","154E1","154E2","154F9","154FA","15500","15501"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":444,"id":"upper-exterior-2-west-column-144","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":143,"columnIndex":16,"outlineFt":[[-44.1145833,-5.8333334],[-43.8333333,1.25],[-43.8333333,12.8333333],[-43.8333333,22.1666666],[-44.0208333,22.1666666],[-44.0208333,37.5],[-43.8333333,37.5],[-43.8333333,46.8333333],[-42.8333333,46.8333333],[-42.8333333,37.5],[-42.6458333,37.5],[-42.6458333,22.1666666],[-42.8333333,22.1666666],[-42.8333333,12.8333333],[-42.8333333,1.25],[-42.5520833,-5.8333334]],"sourceHandles":["1528E","15293","15296","15297","1550D","1550E","15513","15514","15515","15516"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":443,"id":"upper-exterior-2-west-column-143","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":142,"columnIndex":17,"outlineFt":[[-40.78125,-5.8333334],[-40.5,1.25],[-40.5,12.8333333],[-40.2916666,12.8333333],[-40.2916666,22.1666666],[-40.2916666,37.5],[-40.2916666,46.8333333],[-39.7083333,46.8333333],[-39.7083333,37.5],[-39.7083333,22.1666666],[-39.7083333,12.8333333],[-39.5,12.8333333],[-39.5,1.25],[-39.21875,-5.8333334]],"sourceHandles":["15294","15299","1529C","1529D","15509","1550A","15511","15512","15529","1552A","15530","15531"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":442,"id":"upper-exterior-2-west-column-142","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":141,"columnIndex":18,"outlineFt":[[-37.4479166,-5.8333334],[-37.1666666,1.25],[-37.1666666,12.8333333],[-37.1666666,22.1666666],[-37.3541666,22.1666666],[-37.3541666,37.5],[-37.1666666,37.5],[-37.1666666,46.8333333],[-36.1666666,46.8333333],[-36.1666666,37.5],[-35.9791666,37.5],[-35.9791666,22.1666666],[-36.1666666,22.1666666],[-36.1666666,12.8333333],[-36.1666666,1.25],[-35.8854166,-5.8333334]],"sourceHandles":["1529A","1529F","152A2","152A3","1553D","1553E","15543","15544","15545","15546"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":441,"id":"upper-exterior-2-west-column-141","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":140,"columnIndex":19,"outlineFt":[[-34.1145833,-5.8333334],[-33.8333333,1.25],[-33.8333333,12.8333333],[-33.625,12.8333333],[-33.625,22.1666666],[-33.625,37.5],[-33.625,46.8333333],[-33.0416666,46.8333333],[-33.0416666,37.5],[-33.0416666,22.1666666],[-33.0416666,12.8333333],[-32.8333333,12.8333333],[-32.8333333,1.25],[-32.5520833,-5.8333334]],"sourceHandles":["152A0","152A5","152A8","152A9","15539","1553A","15541","15542","15559","1555A","15560","15561"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":440,"id":"upper-exterior-2-west-column-140","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":139,"columnIndex":20,"outlineFt":[[-30.78125,-5.8333334],[-30.5,1.25],[-30.5,12.8333333],[-30.5,22.1666666],[-30.6875,22.1666666],[-30.6875,37.5],[-30.5,37.5],[-30.5,46.8333333],[-29.5,46.8333333],[-29.5,37.5],[-29.3125,37.5],[-29.3125,22.1666666],[-29.5,22.1666666],[-29.5,12.8333333],[-29.5,1.25],[-29.21875,-5.8333334]],"sourceHandles":["152A6","152AB","152AE","152AF","1556D","1556E","15573","15574","15575","15576"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":439,"id":"upper-exterior-2-west-column-139","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":138,"columnIndex":21,"outlineFt":[[-27.4479166,-5.8333334],[-27.1666666,1.25],[-27.1666666,12.8333333],[-26.9583333,12.8333333],[-26.9583333,22.1666666],[-26.9583333,37.5],[-26.9583333,46.8333333],[-26.375,46.8333333],[-26.375,37.5],[-26.375,22.1666666],[-26.375,12.8333333],[-26.1666666,12.8333333],[-26.1666666,1.25],[-25.8854166,-5.8333334]],"sourceHandles":["152AC","152B1","152B4","152B5","15569","1556A","15571","15572","15589","1558A","15590","15591"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":438,"id":"upper-exterior-2-west-column-138","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":137,"columnIndex":22,"outlineFt":[[-24.1145833,-5.8333334],[-23.8333333,1.25],[-23.8333333,12.8333333],[-23.8333333,22.1666666],[-24.0208333,22.1666666],[-24.0208333,37.5],[-23.8333333,37.5],[-23.8333333,46.8333333],[-22.8333333,46.8333333],[-22.8333333,37.5],[-22.6458333,37.5],[-22.6458333,22.1666666],[-22.8333333,22.1666666],[-22.8333333,12.8333333],[-22.8333333,1.25],[-22.5520833,-5.8333334]],"sourceHandles":["152B2","152B7","152BA","152BB","1559D","1559E","155A3","155A4","155A5","155A6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":437,"id":"upper-exterior-2-west-column-137","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":136,"columnIndex":23,"outlineFt":[[-20.78125,-5.8333334],[-20.5,1.25],[-20.5,12.8333333],[-20.2916666,12.8333333],[-20.2916666,22.1666666],[-20.2916666,37.5],[-20.2916666,46.8333333],[-19.7083333,46.8333333],[-19.7083333,37.5],[-19.7083333,22.1666666],[-19.7083333,12.8333333],[-19.5,12.8333333],[-19.5,1.25],[-19.21875,-5.8333334]],"sourceHandles":["152B8","152BD","152C0","152C1","15599","1559A","155A1","155A2","155B9","155BA","155C0","155C1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":436,"id":"upper-exterior-2-west-column-136","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":135,"columnIndex":24,"outlineFt":[[-17.4479166,-5.8333334],[-17.1666666,1.25],[-17.1666666,12.8333333],[-17.1666666,22.1666666],[-17.3541666,22.1666666],[-17.3541666,37.5],[-17.1666666,37.5],[-17.1666666,46.8333333],[-16.1666666,46.8333333],[-16.1666666,37.5],[-15.9791666,37.5],[-15.9791666,22.1666666],[-16.1666666,22.1666666],[-16.1666666,12.8333333],[-16.1666666,1.25],[-15.8854166,-5.8333334]],"sourceHandles":["152BE","152C3","152C6","152C7","155CD","155CE","155D3","155D4","155D5","155D6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":435,"id":"upper-exterior-2-west-column-135","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":134,"columnIndex":25,"outlineFt":[[-14.1145833,-5.8333334],[-13.8333333,1.25],[-13.8333333,12.8333333],[-13.625,12.8333333],[-13.625,22.1666666],[-13.625,37.5],[-13.625,46.8333333],[-13.0416666,46.8333333],[-13.0416666,37.5],[-13.0416666,22.1666666],[-13.0416666,12.8333333],[-12.8333333,12.8333333],[-12.8333333,1.25],[-12.5520833,-5.8333334]],"sourceHandles":["152C4","152C9","152CC","152CD","155C9","155CA","155D1","155D2","155E9","155EA","155F0","155F1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":434,"id":"upper-exterior-2-west-column-134","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":133,"columnIndex":26,"outlineFt":[[-10.78125,-5.8333334],[-10.5,1.25],[-10.5,12.8333333],[-10.5,22.1666666],[-10.6875,22.1666666],[-10.6875,37.5],[-10.5,37.5],[-10.5,46.8333333],[-9.5,46.8333333],[-9.5,37.5],[-9.3125,37.5],[-9.3125,22.1666666],[-9.5,22.1666666],[-9.5,12.8333333],[-9.5,1.25],[-9.21875,-5.8333334]],"sourceHandles":["152CA","152CF","152D2","152D3","155FD","155FE","15603","15604","15605","15606"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":433,"id":"upper-exterior-2-west-column-133","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":132,"columnIndex":27,"outlineFt":[[-7.4479166,-5.8333334],[-7.1666666,1.25],[-7.1666666,12.8333333],[-6.9583333,12.8333333],[-6.9583333,22.1666666],[-6.9583333,37.5],[-6.9583333,46.8333333],[-6.375,46.8333333],[-6.375,37.5],[-6.375,22.1666666],[-6.375,12.8333333],[-6.1666666,12.8333333],[-6.1666666,1.25],[-5.8854166,-5.8333334]],"sourceHandles":["152D0","152D5","152D8","152D9","155F9","155FA","15601","15602","15619","1561A","15620","15621"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":432,"id":"upper-exterior-2-west-column-132","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":131,"columnIndex":28,"outlineFt":[[-4.1145833,-5.8333334],[-3.8333333,1.25],[-3.8333333,12.8333333],[-3.8333333,22.1666666],[-4.0208333,22.1666666],[-4.0208333,37.5],[-3.8333333,37.5],[-3.8333333,46.8333333],[-2.8333333,46.8333333],[-2.8333333,37.5],[-2.6458333,37.5],[-2.6458333,22.1666666],[-2.8333333,22.1666666],[-2.8333333,12.8333333],[-2.8333333,1.25],[-2.5520833,-5.8333334]],"sourceHandles":["152D6","152DB","152DE","152DF","1562D","1562E","15633","15634","15635","15636"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":431,"id":"upper-exterior-2-west-column-131","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":130,"columnIndex":29,"outlineFt":[[-0.78125,-5.8333334],[-0.5,1.25],[-0.5,12.8333333],[-0.2916666,12.8333333],[-0.2916666,22.1666666],[-0.2916666,37.5],[-0.2916666,46.8333333],[0.2916667,46.8333333],[0.2916667,37.5],[0.2916667,22.1666666],[0.2916667,12.8333333],[0.5,12.8333333],[0.5,1.25],[0.78125,-5.8333334]],"sourceHandles":["152DC","152E1","152E4","152E5","15629","1562A","15631","15632","15649","1564A","15650","15651"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":430,"id":"upper-exterior-2-west-column-130","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":129,"columnIndex":30,"outlineFt":[[2.5520834,-5.8333334],[2.8333334,1.25],[2.8333334,12.8333333],[2.8333334,22.1666666],[2.6458334,22.1666666],[2.6458334,37.5],[2.8333334,37.5],[2.8333334,46.8333333],[3.8333334,46.8333333],[3.8333334,37.5],[4.0208334,37.5],[4.0208334,22.1666666],[3.8333334,22.1666666],[3.8333334,12.8333333],[3.8333334,1.25],[4.1145834,-5.8333334]],"sourceHandles":["152E2","152E7","152EA","152EB","1565D","1565E","15663","15664","15665","15666"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":429,"id":"upper-exterior-2-west-column-129","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":128,"columnIndex":31,"outlineFt":[[5.8854167,-5.8333334],[6.1666667,1.25],[6.1666667,12.8333333],[6.375,12.8333333],[6.375,22.1666666],[6.375,37.5],[6.375,46.8333333],[6.9583334,46.8333333],[6.9583334,37.5],[6.9583334,22.1666666],[6.9583334,12.8333333],[7.1666667,12.8333333],[7.1666667,1.25],[7.4479167,-5.8333334]],"sourceHandles":["152E8","152ED","152F0","152F1","15659","1565A","15661","15662","15679","1567A","15680","15681"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":428,"id":"upper-exterior-2-west-column-128","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":127,"columnIndex":32,"outlineFt":[[9.21875,-5.8333334],[9.5,1.25],[9.5,12.8333333],[9.5,22.1666666],[9.3125,22.1666666],[9.3125,37.5],[9.5,37.5],[9.5,46.8333333],[10.5,46.8333333],[10.5,37.5],[10.6875,37.5],[10.6875,22.1666666],[10.5,22.1666666],[10.5,12.8333333],[10.5,1.25],[10.78125,-5.8333334]],"sourceHandles":["152EE","152F3","152F6","152F7","1568D","1568E","15693","15694","15695","15696"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":427,"id":"upper-exterior-2-west-column-127","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":126,"columnIndex":33,"outlineFt":[[12.5520834,-5.8333334],[12.8333334,1.25],[12.8333334,12.8333333],[13.0416667,12.8333333],[13.0416667,22.1666666],[13.0416667,37.5],[13.0416667,46.8333333],[13.625,46.8333333],[13.625,37.5],[13.625,22.1666666],[13.625,12.8333333],[13.8333334,12.8333333],[13.8333334,1.25],[14.1145834,-5.8333334]],"sourceHandles":["152F4","152F9","152FC","152FD","15689","1568A","15691","15692","156A9","156AA","156B0","156B1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":426,"id":"upper-exterior-2-west-column-126","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":125,"columnIndex":34,"outlineFt":[[15.8854167,-5.8333334],[16.1666667,1.25],[16.1666667,12.8333333],[16.1666667,22.1666666],[15.9791667,22.1666666],[15.9791667,37.5],[16.1666667,37.5],[16.1666667,46.8333333],[17.1666667,46.8333333],[17.1666667,37.5],[17.3541667,37.5],[17.3541667,22.1666666],[17.1666667,22.1666666],[17.1666667,12.8333333],[17.1666667,1.25],[17.4479167,-5.8333334]],"sourceHandles":["152FA","152FF","15302","15303","156BD","156BE","156C3","156C4","156C5","156C6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":425,"id":"upper-exterior-2-west-column-125","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":124,"columnIndex":35,"outlineFt":[[19.21875,-5.8333334],[19.5,1.25],[19.5,12.8333333],[19.7083334,12.8333333],[19.7083334,22.1666666],[19.7083334,37.5],[19.7083334,46.8333333],[20.2916667,46.8333333],[20.2916667,37.5],[20.2916667,22.1666666],[20.2916667,12.8333333],[20.5,12.8333333],[20.5,1.25],[20.78125,-5.8333334]],"sourceHandles":["15300","15305","15308","15309","156B9","156BA","156C1","156C2","156D9","156DA","156E0","156E1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":424,"id":"upper-exterior-2-west-column-124","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":123,"columnIndex":36,"outlineFt":[[22.5520834,-5.8333334],[22.8333334,1.25],[22.8333334,12.8333333],[22.8333334,22.1666666],[22.6458334,22.1666666],[22.6458334,37.5],[22.8333334,37.5],[22.8333334,46.8333333],[23.8333334,46.8333333],[23.8333334,37.5],[24.0208334,37.5],[24.0208334,22.1666666],[23.8333334,22.1666666],[23.8333334,12.8333333],[23.8333334,1.25],[24.1145834,-5.8333334]],"sourceHandles":["15306","1530B","1530E","1530F","156ED","156EE","156F3","156F4","156F5","156F6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":423,"id":"upper-exterior-2-west-column-123","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":122,"columnIndex":37,"outlineFt":[[25.8854167,-5.8333334],[26.1666667,1.25],[26.1666667,12.8333333],[26.375,12.8333333],[26.375,22.1666666],[26.375,37.5],[26.375,46.8333333],[26.9583334,46.8333333],[26.9583334,37.5],[26.9583334,22.1666666],[26.9583334,12.8333333],[27.1666667,12.8333333],[27.1666667,1.25],[27.4479167,-5.8333334]],"sourceHandles":["1530C","15311","15314","15315","156E9","156EA","156F1","156F2","15709","1570A","15710","15711"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":422,"id":"upper-exterior-2-west-column-122","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":121,"columnIndex":38,"outlineFt":[[29.21875,-5.8333334],[29.5,1.25],[29.5,12.8333333],[29.5,22.1666666],[29.3125,22.1666666],[29.3125,37.5],[29.5,37.5],[29.5,46.8333333],[30.5,46.8333333],[30.5,37.5],[30.6875,37.5],[30.6875,22.1666666],[30.5,22.1666666],[30.5,12.8333333],[30.5,1.25],[30.78125,-5.8333334]],"sourceHandles":["15312","15317","1531A","1531B","1571D","1571E","15723","15724","15725","15726"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":421,"id":"upper-exterior-2-west-column-121","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":120,"columnIndex":39,"outlineFt":[[32.5520834,-5.8333334],[32.8333334,1.25],[32.8333334,12.8333333],[33.0416667,12.8333333],[33.0416667,22.1666666],[33.0416667,37.5],[33.0416667,46.8333333],[33.625,46.8333333],[33.625,37.5],[33.625,22.1666666],[33.625,12.8333333],[33.8333334,12.8333333],[33.8333334,1.25],[34.1145834,-5.8333334]],"sourceHandles":["15318","1531D","15320","15321","15719","1571A","15721","15722","15739","1573A","15740","15741"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":420,"id":"upper-exterior-2-west-column-120","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":119,"columnIndex":40,"outlineFt":[[35.8854167,-5.8333334],[36.1666667,1.25],[36.1666667,12.8333333],[36.1666667,22.1666666],[35.9791667,22.1666666],[35.9791667,37.5],[36.1666667,37.5],[36.1666667,46.8333333],[37.1666667,46.8333333],[37.1666667,37.5],[37.3541667,37.5],[37.3541667,22.1666666],[37.1666667,22.1666666],[37.1666667,12.8333333],[37.1666667,1.25],[37.4479167,-5.8333334]],"sourceHandles":["1531E","15323","15326","15327","1574D","1574E","15753","15754","15755","15756"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":419,"id":"upper-exterior-2-west-column-119","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":118,"columnIndex":41,"outlineFt":[[39.21875,-5.8333334],[39.5,1.25],[39.5,12.8333333],[39.7083334,12.8333333],[39.7083334,22.1666666],[39.7083334,37.5],[39.7083334,46.8333333],[40.2916667,46.8333333],[40.2916667,37.5],[40.2916667,22.1666666],[40.2916667,12.8333333],[40.5,12.8333333],[40.5,1.25],[40.78125,-5.8333334]],"sourceHandles":["15324","15329","1532C","1532D","15749","1574A","15751","15752","15769","1576A","15770","15771"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":418,"id":"upper-exterior-2-west-column-118","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":117,"columnIndex":42,"outlineFt":[[42.5520834,-5.8333334],[42.8333334,1.25],[42.8333334,12.8333333],[42.8333334,22.1666666],[42.6458334,22.1666666],[42.6458334,37.5],[42.8333334,37.5],[42.8333334,46.8333333],[43.8333334,46.8333333],[43.8333334,37.5],[44.0208334,37.5],[44.0208334,22.1666666],[43.8333334,22.1666666],[43.8333334,12.8333333],[43.8333334,1.25],[44.1145834,-5.8333334]],"sourceHandles":["1532A","1532F","15332","15333","1577D","1577E","15783","15784","15785","15786"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":417,"id":"upper-exterior-2-west-column-117","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":116,"columnIndex":43,"outlineFt":[[45.8854167,-5.8333334],[46.1666667,1.25],[46.1666667,12.8333333],[46.375,12.8333333],[46.375,22.1666666],[46.375,37.5],[46.375,46.8333333],[46.9583334,46.8333333],[46.9583334,37.5],[46.9583334,22.1666666],[46.9583334,12.8333333],[47.1666667,12.8333333],[47.1666667,1.25],[47.4479167,-5.8333334]],"sourceHandles":["15330","15335","15338","15339","15779","1577A","15781","15782","15799","1579A","157A0","157A1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":416,"id":"upper-exterior-2-west-column-116","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":115,"columnIndex":44,"outlineFt":[[49.21875,-5.8333334],[49.5,1.25],[49.5,12.8333333],[49.5,22.1666666],[49.3125,22.1666666],[49.3125,37.5],[49.5,37.5],[49.5,46.8333333],[50.5,46.8333333],[50.5,37.5],[50.6875,37.5],[50.6875,22.1666666],[50.5,22.1666666],[50.5,12.8333333],[50.5,1.25],[50.78125,-5.8333334]],"sourceHandles":["15336","1533B","1533E","1533F","157AD","157AE","157B3","157B4","157B5","157B6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":415,"id":"upper-exterior-2-west-column-115","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":114,"columnIndex":45,"outlineFt":[[52.5520834,-5.8333334],[52.8333334,1.25],[52.8333334,12.8333333],[53.0416667,12.8333333],[53.0416667,22.1666666],[53.0416667,37.5],[53.0416667,46.8333333],[53.625,46.8333333],[53.625,37.5],[53.625,22.1666666],[53.625,12.8333333],[53.8333334,12.8333333],[53.8333334,1.25],[54.1145834,-5.8333334]],"sourceHandles":["1533C","15341","15344","15345","157A9","157AA","157B1","157B2","157C9","157CA","157D0","157D1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":414,"id":"upper-exterior-2-west-column-114","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":113,"columnIndex":46,"outlineFt":[[55.8854167,-5.8333334],[56.1666667,1.25],[56.1666667,12.8333333],[56.1666667,22.1666666],[55.9791667,22.1666666],[55.9791667,37.5],[56.1666667,37.5],[56.1666667,46.8333333],[57.1666667,46.8333333],[57.1666667,37.5],[57.3541667,37.5],[57.3541667,22.1666666],[57.1666667,22.1666666],[57.1666667,12.8333333],[57.1666667,1.25],[57.4479167,-5.8333334]],"sourceHandles":["15342","15347","1534A","1534B","157DD","157DE","157E3","157E4","157E5","157E6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":413,"id":"upper-exterior-2-west-column-113","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":112,"columnIndex":47,"outlineFt":[[59.21875,-5.8333334],[59.5,1.25],[59.5,12.8333333],[59.7083334,12.8333333],[59.7083334,22.1666666],[59.7083334,37.5],[59.7083334,46.8333333],[60.2916667,46.8333333],[60.2916667,37.5],[60.2916667,22.1666666],[60.2916667,12.8333333],[60.5,12.8333333],[60.5,1.25],[60.78125,-5.8333334]],"sourceHandles":["15348","1534D","15350","15351","157D9","157DA","157E1","157E2","157F9","157FA","15800","15801"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":412,"id":"upper-exterior-2-west-column-112","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":111,"columnIndex":48,"outlineFt":[[62.5520834,-5.8333334],[62.8333334,1.25],[62.8333334,12.8333333],[62.8333334,22.1666666],[62.6458334,22.1666666],[62.6458334,37.5],[62.8333334,37.5],[62.8333334,46.8333333],[63.8333334,46.8333333],[63.8333334,37.5],[64.0208334,37.5],[64.0208334,22.1666666],[63.8333334,22.1666666],[63.8333334,12.8333333],[63.8333334,1.25],[64.1145834,-5.8333334]],"sourceHandles":["1534E","15353","15356","15357","1580D","1580E","15813","15814","15815","15816"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":411,"id":"upper-exterior-2-west-column-111","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":110,"columnIndex":49,"outlineFt":[[65.8854167,-5.8333334],[66.1666667,1.25],[66.1666667,12.8333333],[66.375,12.8333333],[66.375,22.1666666],[66.375,37.5],[66.375,46.8333333],[66.9583334,46.8333333],[66.9583334,37.5],[66.9583334,22.1666666],[66.9583334,12.8333333],[67.1666667,12.8333333],[67.1666667,1.25],[67.4479167,-5.8333334]],"sourceHandles":["15354","15359","1535C","1535D","15809","1580A","15811","15812","15829","1582A","15830","15831"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":410,"id":"upper-exterior-2-west-column-110","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":109,"columnIndex":50,"outlineFt":[[69.21875,-5.8333334],[69.5,1.25],[69.5,12.8333333],[69.5,22.1666666],[69.3125,22.1666666],[69.3125,37.5],[69.5,37.5],[69.5,46.8333333],[70.5,46.8333333],[70.5,37.5],[70.6875,37.5],[70.6875,22.1666666],[70.5,22.1666666],[70.5,12.8333333],[70.5,1.25],[70.78125,-5.8333334]],"sourceHandles":["1535A","1535F","15362","15363","1583D","1583E","15843","15844","15845","15846"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":409,"id":"upper-exterior-2-west-column-109","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":108,"columnIndex":51,"outlineFt":[[72.5520834,-5.8333334],[72.8333334,1.25],[72.8333334,12.8333333],[73.0416667,12.8333333],[73.0416667,22.1666666],[73.0416667,37.5],[73.0416667,46.8333333],[73.625,46.8333333],[73.625,37.5],[73.625,22.1666666],[73.625,12.8333333],[73.8333334,12.8333333],[73.8333334,1.25],[74.1145834,-5.8333334]],"sourceHandles":["15360","15365","15368","15369","15839","1583A","15841","15842","15859","1585A","15860","15861"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":408,"id":"upper-exterior-2-west-column-108","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":107,"columnIndex":52,"outlineFt":[[75.8854167,-5.8333334],[76.1666667,1.25],[76.1666667,12.8333333],[76.1666667,22.1666666],[75.9791667,22.1666666],[75.9791667,37.5],[76.1666667,37.5],[76.1666667,46.8333333],[77.1666667,46.8333333],[77.1666667,37.5],[77.3541667,37.5],[77.3541667,22.1666666],[77.1666667,22.1666666],[77.1666667,12.8333333],[77.1666667,1.25],[77.4479167,-5.8333334]],"sourceHandles":["15366","1536B","1536E","1536F","1586D","1586E","15873","15874","15875","15876"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":407,"id":"upper-exterior-2-west-column-107","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":106,"columnIndex":53,"outlineFt":[[79.21875,-5.8333334],[79.5,1.25],[79.5,12.8333333],[79.7083334,12.8333333],[79.7083334,22.1666666],[79.7083334,37.5],[79.7083334,46.8333333],[80.2916667,46.8333333],[80.2916667,37.5],[80.2916667,22.1666666],[80.2916667,12.8333333],[80.5,12.8333333],[80.5,1.25],[80.78125,-5.8333334]],"sourceHandles":["1536C","15371","15374","15375","15869","1586A","15871","15872","15889","1588A","15890","15891"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":406,"id":"upper-exterior-2-west-column-106","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":105,"columnIndex":54,"outlineFt":[[82.5520834,-5.8333334],[82.8333334,1.25],[82.8333334,12.8333333],[82.8333334,22.1666666],[82.6458334,22.1666666],[82.6458334,37.5],[82.8333334,37.5],[82.8333334,46.8333333],[83.8333334,46.8333333],[83.8333334,37.5],[84.0208334,37.5],[84.0208334,22.1666666],[83.8333334,22.1666666],[83.8333334,12.8333333],[83.8333334,1.25],[84.1145834,-5.8333334]],"sourceHandles":["15372","15377","1537A","1537B","1589D","1589E","158A3","158A4","158A5","158A6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":405,"id":"upper-exterior-2-west-column-105","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":104,"columnIndex":55,"outlineFt":[[85.8854167,-5.8333334],[86.1666667,1.25],[86.1666667,12.8333333],[86.375,12.8333333],[86.375,22.1666666],[86.375,37.5],[86.375,46.8333333],[86.9583334,46.8333333],[86.9583334,37.5],[86.9583334,22.1666666],[86.9583334,12.8333333],[87.1666667,12.8333333],[87.1666667,1.25],[87.4479167,-5.8333334]],"sourceHandles":["15378","1537D","15380","15381","15899","1589A","158A1","158A2","158B9","158BA","158C0","158C1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":404,"id":"upper-exterior-2-west-column-104","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":103,"columnIndex":56,"outlineFt":[[89.21875,-5.8333334],[89.5,1.25],[89.5,12.8333333],[89.5,22.1666666],[89.3125,22.1666666],[89.3125,37.5],[89.5,37.5],[89.5,46.8333333],[90.5,46.8333333],[90.5,37.5],[90.6875,37.5],[90.6875,22.1666666],[90.5,22.1666666],[90.5,12.8333333],[90.5,1.25],[90.78125,-5.8333334]],"sourceHandles":["1537E","15383","15386","15387","158CD","158CE","158D3","158D4","158D5","158D6"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":403,"id":"upper-exterior-2-west-column-103","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":102,"columnIndex":57,"outlineFt":[[92.5520834,-5.8333334],[92.8333334,1.25],[92.8333334,12.8333333],[93.0416667,12.8333333],[93.0416667,22.1666666],[93.0416667,37.5],[93.0416667,46.8333333],[93.625,46.8333333],[93.625,37.5],[93.625,22.1666666],[93.625,12.8333333],[93.8333334,12.8333333],[93.8333334,1.25],[94.1145834,-5.8333334]],"sourceHandles":["15384","15389","1538B","1538C","158C9","158CA","158D1","158D2","158E9","158EA","158F0","158F1"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":402,"id":"upper-exterior-2-west-column-102","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"column","column":101,"columnIndex":58,"outlineFt":[[95.8854167,-5.8333334],[96.1170343,-0.0],[96.1666667,1.25],[96.1668614,1.25],[96.1668614,17.5],[96.1668614,17.5049035],[96.1668614,22.1666666],[95.9791667,22.1666666],[95.9791667,37.5],[96.1668614,37.5],[96.1668614,49.0833333],[98.375,49.0833333],[98.375,37.5],[98.375,22.1666666],[98.375,17.5049035],[98.375,17.5],[98.375,1.25],[98.375,-0.0],[98.375,-5.8333334]],"sourceHandles":["1538D","1538E","1538F","15391","15393","15394","15395","158FF","15901"],"floor":107,"profileDescription":"Traced elevation envelope; alternating narrow upper profiles retained. Normal section depth and gauges unresolved.","sourceColumn":401,"id":"upper-exterior-2-west-column-101","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":0,"outlineFt":[[-93.8333333,1.25],[-94.1145833,-5.8333334],[-95.8854166,-5.8333334],[-96.1170343,-0.0],[-96.1666666,1.25]],"sourceHandles":["15228","15229"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-0","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":1,"outlineFt":[[-90.5,1.25],[-90.78125,-5.8333334],[-92.5520833,-5.8333334],[-92.8333333,1.25]],"sourceHandles":["15227","1522D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-1","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":2,"outlineFt":[[-87.1666666,1.25],[-87.4479166,-5.8333334],[-89.21875,-5.8333334],[-89.5,1.25]],"sourceHandles":["1523E","15241"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-2","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":3,"outlineFt":[[-83.8333333,1.25],[-84.1145833,-5.8333334],[-85.8854166,-5.8333334],[-86.1666666,1.25]],"sourceHandles":["15244","15247"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-3","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":4,"outlineFt":[[-80.5,1.25],[-80.78125,-5.8333334],[-82.5520833,-5.8333334],[-82.8333333,1.25]],"sourceHandles":["1524A","1524D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-4","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":5,"outlineFt":[[-77.1666666,1.25],[-77.4479166,-5.8333334],[-79.21875,-5.8333334],[-79.5,1.25]],"sourceHandles":["15250","15253"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-5","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":6,"outlineFt":[[-73.8333333,1.25],[-74.1145833,-5.8333334],[-75.8854166,-5.8333334],[-76.1666666,1.25]],"sourceHandles":["15256","15259"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-6","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":7,"outlineFt":[[-70.5,1.25],[-70.78125,-5.8333334],[-72.5520833,-5.8333334],[-72.8333333,1.25]],"sourceHandles":["1525C","1525F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-7","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":8,"outlineFt":[[-67.1666666,1.25],[-67.4479166,-5.8333334],[-69.21875,-5.8333334],[-69.5,1.25]],"sourceHandles":["15262","15265"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-8","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":9,"outlineFt":[[-63.8333333,1.25],[-64.1145833,-5.8333334],[-65.8854166,-5.8333334],[-66.1666666,1.25]],"sourceHandles":["15268","1526B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-9","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":10,"outlineFt":[[-60.5,1.25],[-60.78125,-5.8333334],[-62.5520833,-5.8333334],[-62.8333333,1.25]],"sourceHandles":["1526E","15271"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-10","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":11,"outlineFt":[[-57.1666666,1.25],[-57.4479166,-5.8333334],[-59.21875,-5.8333334],[-59.5,1.25]],"sourceHandles":["15274","15277"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-11","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":12,"outlineFt":[[-53.8333333,1.25],[-54.1145833,-5.8333334],[-55.8854166,-5.8333334],[-56.1666666,1.25]],"sourceHandles":["1527A","1527D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-12","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":13,"outlineFt":[[-50.5,1.25],[-50.78125,-5.8333334],[-52.5520833,-5.8333334],[-52.8333333,1.25]],"sourceHandles":["15280","15283"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-13","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":14,"outlineFt":[[-47.1666666,1.25],[-47.4479166,-5.8333334],[-49.21875,-5.8333334],[-49.5,1.25]],"sourceHandles":["15286","15289"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-14","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":15,"outlineFt":[[-43.8333333,1.25],[-44.1145833,-5.8333334],[-45.8854166,-5.8333334],[-46.1666666,1.25]],"sourceHandles":["1528C","1528F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-15","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":16,"outlineFt":[[-40.5,1.25],[-40.78125,-5.8333334],[-42.5520833,-5.8333334],[-42.8333333,1.25]],"sourceHandles":["15292","15295"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-16","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":17,"outlineFt":[[-37.1666666,1.25],[-37.4479166,-5.8333334],[-39.21875,-5.8333334],[-39.5,1.25]],"sourceHandles":["15298","1529B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-17","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":18,"outlineFt":[[-33.8333333,1.25],[-34.1145833,-5.8333334],[-35.8854166,-5.8333334],[-36.1666666,1.25]],"sourceHandles":["1529E","152A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-18","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":19,"outlineFt":[[-30.5,1.25],[-30.78125,-5.8333334],[-32.5520833,-5.8333334],[-32.8333333,1.25]],"sourceHandles":["152A4","152A7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-19","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":20,"outlineFt":[[-27.1666666,1.25],[-27.4479166,-5.8333334],[-29.21875,-5.8333334],[-29.5,1.25]],"sourceHandles":["152AA","152AD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-20","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":21,"outlineFt":[[-23.8333333,1.25],[-24.1145833,-5.8333334],[-25.8854166,-5.8333334],[-26.1666666,1.25]],"sourceHandles":["152B0","152B3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-21","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":22,"outlineFt":[[-20.5,1.25],[-20.78125,-5.8333334],[-22.5520833,-5.8333334],[-22.8333333,1.25]],"sourceHandles":["152B6","152B9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-22","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":23,"outlineFt":[[-17.1666666,1.25],[-17.4479166,-5.8333334],[-19.21875,-5.8333334],[-19.5,1.25]],"sourceHandles":["152BC","152BF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-23","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":24,"outlineFt":[[-13.8333333,1.25],[-14.1145833,-5.8333334],[-15.8854166,-5.8333334],[-16.1666666,1.25]],"sourceHandles":["152C2","152C5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-24","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":25,"outlineFt":[[-10.5,1.25],[-10.78125,-5.8333334],[-12.5520833,-5.8333334],[-12.8333333,1.25]],"sourceHandles":["152C8","152CB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-25","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":26,"outlineFt":[[-7.1666666,1.25],[-7.4479166,-5.8333334],[-9.21875,-5.8333334],[-9.5,1.25]],"sourceHandles":["152CE","152D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-26","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":27,"outlineFt":[[-3.8333333,1.25],[-4.1145833,-5.8333334],[-5.8854166,-5.8333334],[-6.1666666,1.25]],"sourceHandles":["152D4","152D7"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-27","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":28,"outlineFt":[[-0.5,1.25],[-0.78125,-5.8333334],[-2.5520833,-5.8333334],[-2.8333333,1.25]],"sourceHandles":["152DA","152DD"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-28","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":29,"outlineFt":[[2.8333334,1.25],[2.5520834,-5.8333334],[0.78125,-5.8333334],[0.5,1.25]],"sourceHandles":["152E0","152E3"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-29","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":30,"outlineFt":[[6.1666667,1.25],[5.8854167,-5.8333334],[4.1145834,-5.8333334],[3.8333334,1.25]],"sourceHandles":["152E6","152E9"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-30","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":31,"outlineFt":[[9.5,1.25],[9.21875,-5.8333334],[7.4479167,-5.8333334],[7.1666667,1.25]],"sourceHandles":["152EC","152EF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-31","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":32,"outlineFt":[[12.8333334,1.25],[12.5520834,-5.8333334],[10.78125,-5.8333334],[10.5,1.25]],"sourceHandles":["152F2","152F5"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-32","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":33,"outlineFt":[[16.1666667,1.25],[15.8854167,-5.8333334],[14.1145834,-5.8333334],[13.8333334,1.25]],"sourceHandles":["152F8","152FB"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-33","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":34,"outlineFt":[[19.5,1.25],[19.21875,-5.8333334],[17.4479167,-5.8333334],[17.1666667,1.25]],"sourceHandles":["152FE","15301"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-34","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":35,"outlineFt":[[22.8333334,1.25],[22.5520834,-5.8333334],[20.78125,-5.8333334],[20.5,1.25]],"sourceHandles":["15304","15307"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-35","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":36,"outlineFt":[[26.1666667,1.25],[25.8854167,-5.8333334],[24.1145834,-5.8333334],[23.8333334,1.25]],"sourceHandles":["1530A","1530D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-36","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":37,"outlineFt":[[29.5,1.25],[29.21875,-5.8333334],[27.4479167,-5.8333334],[27.1666667,1.25]],"sourceHandles":["15310","15313"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-37","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":38,"outlineFt":[[32.8333334,1.25],[32.5520834,-5.8333334],[30.78125,-5.8333334],[30.5,1.25]],"sourceHandles":["15316","15319"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-38","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":39,"outlineFt":[[36.1666667,1.25],[35.8854167,-5.8333334],[34.1145834,-5.8333334],[33.8333334,1.25]],"sourceHandles":["1531C","1531F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-39","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":40,"outlineFt":[[39.5,1.25],[39.21875,-5.8333334],[37.4479167,-5.8333334],[37.1666667,1.25]],"sourceHandles":["15322","15325"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-40","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":41,"outlineFt":[[42.8333334,1.25],[42.5520834,-5.8333334],[40.78125,-5.8333334],[40.5,1.25]],"sourceHandles":["15328","1532B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-41","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":42,"outlineFt":[[46.1666667,1.25],[45.8854167,-5.8333334],[44.1145834,-5.8333334],[43.8333334,1.25]],"sourceHandles":["1532E","15331"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-42","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":43,"outlineFt":[[49.5,1.25],[49.21875,-5.8333334],[47.4479167,-5.8333334],[47.1666667,1.25]],"sourceHandles":["15334","15337"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-43","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":44,"outlineFt":[[52.8333334,1.25],[52.5520834,-5.8333334],[50.78125,-5.8333334],[50.5,1.25]],"sourceHandles":["1533A","1533D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-44","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":45,"outlineFt":[[56.1666667,1.25],[55.8854167,-5.8333334],[54.1145834,-5.8333334],[53.8333334,1.25]],"sourceHandles":["15340","15343"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-45","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":46,"outlineFt":[[59.5,1.25],[59.21875,-5.8333334],[57.4479167,-5.8333334],[57.1666667,1.25]],"sourceHandles":["15346","15349"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-46","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":47,"outlineFt":[[62.8333334,1.25],[62.5520834,-5.8333334],[60.78125,-5.8333334],[60.5,1.25]],"sourceHandles":["1534C","1534F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-47","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":48,"outlineFt":[[66.1666667,1.25],[65.8854167,-5.8333334],[64.1145834,-5.8333334],[63.8333334,1.25]],"sourceHandles":["15352","15355"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-48","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":49,"outlineFt":[[69.5,1.25],[69.21875,-5.8333334],[67.4479167,-5.8333334],[67.1666667,1.25]],"sourceHandles":["15358","1535B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-49","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":50,"outlineFt":[[72.8333334,1.25],[72.5520834,-5.8333334],[70.78125,-5.8333334],[70.5,1.25]],"sourceHandles":["1535E","15361"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-50","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":51,"outlineFt":[[76.1666667,1.25],[75.8854167,-5.8333334],[74.1145834,-5.8333334],[73.8333334,1.25]],"sourceHandles":["15364","15367"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-51","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":52,"outlineFt":[[79.5,1.25],[79.21875,-5.8333334],[77.4479167,-5.8333334],[77.1666667,1.25]],"sourceHandles":["1536A","1536D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-52","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":53,"outlineFt":[[82.8333334,1.25],[82.5520834,-5.8333334],[80.78125,-5.8333334],[80.5,1.25]],"sourceHandles":["15370","15373"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-53","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":54,"outlineFt":[[86.1666667,1.25],[85.8854167,-5.8333334],[84.1145834,-5.8333334],[83.8333334,1.25]],"sourceHandles":["15376","15379"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-54","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":55,"outlineFt":[[89.5,1.25],[89.21875,-5.8333334],[87.4479167,-5.8333334],[87.1666667,1.25]],"sourceHandles":["1537C","1537F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-55","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":56,"outlineFt":[[92.8333334,1.25],[92.5520834,-5.8333334],[90.78125,-5.8333334],[90.5,1.25]],"sourceHandles":["15382","15385"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-56","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":107,"bay":57,"outlineFt":[[96.1666667,1.25],[96.1170343,-0.0],[95.8854167,-5.8333334],[94.1145834,-5.8333334],[93.8333334,1.25]],"sourceHandles":["15388","1538A"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-107-57","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":0,"outlineFt":[[-93.625,18.8333333],[-93.625,12.8333333],[-93.8333333,12.8333333],[-96.1666666,12.8333333],[-96.1666666,17.5],[-96.1666666,18.8333333]],"sourceHandles":["1539E","1539F","153BC"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-0","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":1,"outlineFt":[[-90.5,18.8333333],[-90.5,12.8333333],[-92.8333333,12.8333333],[-93.0416666,12.8333333],[-93.0416666,18.8333333]],"sourceHandles":["153BA","153BB","153BE"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-1","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":2,"outlineFt":[[-86.9583333,18.8333333],[-86.9583333,12.8333333],[-87.1666666,12.8333333],[-89.5,12.8333333],[-89.5,18.8333333]],"sourceHandles":["153B8","153B9","153BF"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-2","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":3,"outlineFt":[[-83.8333333,18.8333333],[-83.8333333,12.8333333],[-86.1666666,12.8333333],[-86.375,12.8333333],[-86.375,18.8333333]],"sourceHandles":["153FF","15400","15401"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-3","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":4,"outlineFt":[[-80.2916666,18.8333333],[-80.2916666,12.8333333],[-80.5,12.8333333],[-82.8333333,12.8333333],[-82.8333333,18.8333333]],"sourceHandles":["153FD","153FE","15402"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-4","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":5,"outlineFt":[[-77.1666666,18.8333333],[-77.1666666,12.8333333],[-79.5,12.8333333],[-79.7083333,12.8333333],[-79.7083333,18.8333333]],"sourceHandles":["1542F","15430","15431"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-5","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":6,"outlineFt":[[-73.625,18.8333333],[-73.625,12.8333333],[-73.8333333,12.8333333],[-76.1666666,12.8333333],[-76.1666666,18.8333333]],"sourceHandles":["1542D","1542E","15432"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-6","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":7,"outlineFt":[[-70.5,18.8333333],[-70.5,12.8333333],[-72.8333333,12.8333333],[-73.0416666,12.8333333],[-73.0416666,18.8333333]],"sourceHandles":["1545F","15460","15461"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-7","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":8,"outlineFt":[[-66.9583333,18.8333333],[-66.9583333,12.8333333],[-67.1666666,12.8333333],[-69.5,12.8333333],[-69.5,18.8333333]],"sourceHandles":["1545D","1545E","15462"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-8","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":9,"outlineFt":[[-63.8333333,18.8333333],[-63.8333333,12.8333333],[-66.1666666,12.8333333],[-66.375,12.8333333],[-66.375,18.8333333]],"sourceHandles":["1548F","15490","15491"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-9","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":10,"outlineFt":[[-60.2916666,18.8333333],[-60.2916666,12.8333333],[-60.5,12.8333333],[-62.8333333,12.8333333],[-62.8333333,18.8333333]],"sourceHandles":["1548D","1548E","15492"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-10","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":11,"outlineFt":[[-57.1666666,18.8333333],[-57.1666666,12.8333333],[-59.5,12.8333333],[-59.7083333,12.8333333],[-59.7083333,18.8333333]],"sourceHandles":["154BF","154C0","154C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-11","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":12,"outlineFt":[[-53.625,18.8333333],[-53.625,12.8333333],[-53.8333333,12.8333333],[-56.1666666,12.8333333],[-56.1666666,18.8333333]],"sourceHandles":["154BD","154BE","154C2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-12","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":13,"outlineFt":[[-50.5,18.8333333],[-50.5,12.8333333],[-52.8333333,12.8333333],[-53.0416666,12.8333333],[-53.0416666,18.8333333]],"sourceHandles":["154EF","154F0","154F1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-13","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":14,"outlineFt":[[-46.9583333,18.8333333],[-46.9583333,12.8333333],[-47.1666666,12.8333333],[-49.5,12.8333333],[-49.5,18.8333333]],"sourceHandles":["154ED","154EE","154F2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-14","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":15,"outlineFt":[[-43.8333333,18.8333333],[-43.8333333,12.8333333],[-46.1666666,12.8333333],[-46.375,12.8333333],[-46.375,18.8333333]],"sourceHandles":["1551F","15520","15521"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-15","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":16,"outlineFt":[[-40.2916666,18.8333333],[-40.2916666,12.8333333],[-40.5,12.8333333],[-42.8333333,12.8333333],[-42.8333333,18.8333333]],"sourceHandles":["1551D","1551E","15522"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-16","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":17,"outlineFt":[[-37.1666666,18.8333333],[-37.1666666,12.8333333],[-39.5,12.8333333],[-39.7083333,12.8333333],[-39.7083333,18.8333333]],"sourceHandles":["1554F","15550","15551"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-17","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":18,"outlineFt":[[-33.625,18.8333333],[-33.625,12.8333333],[-33.8333333,12.8333333],[-36.1666666,12.8333333],[-36.1666666,18.8333333]],"sourceHandles":["1554D","1554E","15552"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-18","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":19,"outlineFt":[[-30.5,18.8333333],[-30.5,12.8333333],[-32.8333333,12.8333333],[-33.0416666,12.8333333],[-33.0416666,18.8333333]],"sourceHandles":["1557F","15580","15581"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-19","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":20,"outlineFt":[[-26.9583333,18.8333333],[-26.9583333,12.8333333],[-27.1666666,12.8333333],[-29.5,12.8333333],[-29.5,18.8333333]],"sourceHandles":["1557D","1557E","15582"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-20","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":21,"outlineFt":[[-23.8333333,18.8333333],[-23.8333333,12.8333333],[-26.1666666,12.8333333],[-26.375,12.8333333],[-26.375,18.8333333]],"sourceHandles":["155AF","155B0","155B1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-21","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":22,"outlineFt":[[-20.2916666,18.8333333],[-20.2916666,12.8333333],[-20.5,12.8333333],[-22.8333333,12.8333333],[-22.8333333,18.8333333]],"sourceHandles":["155AD","155AE","155B2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-22","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":23,"outlineFt":[[-17.1666666,18.8333333],[-17.1666666,12.8333333],[-19.5,12.8333333],[-19.7083333,12.8333333],[-19.7083333,18.8333333]],"sourceHandles":["155DF","155E0","155E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-23","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":24,"outlineFt":[[-13.625,18.8333333],[-13.625,12.8333333],[-13.8333333,12.8333333],[-16.1666666,12.8333333],[-16.1666666,18.8333333]],"sourceHandles":["155DD","155DE","155E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-24","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":25,"outlineFt":[[-10.5,18.8333333],[-10.5,12.8333333],[-12.8333333,12.8333333],[-13.0416666,12.8333333],[-13.0416666,18.8333333]],"sourceHandles":["1560F","15610","15611"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-25","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":26,"outlineFt":[[-6.9583333,18.8333333],[-6.9583333,12.8333333],[-7.1666666,12.8333333],[-9.5,12.8333333],[-9.5,18.8333333]],"sourceHandles":["1560D","1560E","15612"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-26","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":27,"outlineFt":[[-3.8333333,18.8333333],[-3.8333333,12.8333333],[-6.1666666,12.8333333],[-6.375,12.8333333],[-6.375,18.8333333]],"sourceHandles":["1563F","15640","15641"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-27","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":28,"outlineFt":[[-0.2916666,18.8333333],[-0.2916666,12.8333333],[-0.5,12.8333333],[-2.8333333,12.8333333],[-2.8333333,18.8333333]],"sourceHandles":["1563D","1563E","15642"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-28","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":29,"outlineFt":[[2.8333334,18.8333333],[2.8333334,12.8333333],[0.5,12.8333333],[0.2916667,12.8333333],[0.2916667,18.8333333]],"sourceHandles":["1566F","15670","15671"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-29","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":30,"outlineFt":[[6.375,18.8333333],[6.375,12.8333333],[6.1666667,12.8333333],[3.8333334,12.8333333],[3.8333334,18.8333333]],"sourceHandles":["1566D","1566E","15672"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-30","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":31,"outlineFt":[[9.5,18.8333333],[9.5,12.8333333],[7.1666667,12.8333333],[6.9583334,12.8333333],[6.9583334,18.8333333]],"sourceHandles":["1569F","156A0","156A1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-31","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":32,"outlineFt":[[13.0416667,18.8333333],[13.0416667,12.8333333],[12.8333334,12.8333333],[10.5,12.8333333],[10.5,18.8333333]],"sourceHandles":["1569D","1569E","156A2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-32","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":33,"outlineFt":[[16.1666667,18.8333333],[16.1666667,12.8333333],[13.8333334,12.8333333],[13.625,12.8333333],[13.625,18.8333333]],"sourceHandles":["156CF","156D0","156D1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-33","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":34,"outlineFt":[[19.7083334,18.8333333],[19.7083334,12.8333333],[19.5,12.8333333],[17.1666667,12.8333333],[17.1666667,18.8333333]],"sourceHandles":["156CD","156CE","156D2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-34","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":35,"outlineFt":[[22.8333334,18.8333333],[22.8333334,12.8333333],[20.5,12.8333333],[20.2916667,12.8333333],[20.2916667,18.8333333]],"sourceHandles":["156FF","15700","15701"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-35","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":36,"outlineFt":[[26.375,18.8333333],[26.375,12.8333333],[26.1666667,12.8333333],[23.8333334,12.8333333],[23.8333334,18.8333333]],"sourceHandles":["156FD","156FE","15702"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-36","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":37,"outlineFt":[[29.5,18.8333333],[29.5,12.8333333],[27.1666667,12.8333333],[26.9583334,12.8333333],[26.9583334,18.8333333]],"sourceHandles":["1572F","15730","15731"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-37","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":38,"outlineFt":[[33.0416667,18.8333333],[33.0416667,12.8333333],[32.8333334,12.8333333],[30.5,12.8333333],[30.5,18.8333333]],"sourceHandles":["1572D","1572E","15732"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-38","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":39,"outlineFt":[[36.1666667,18.8333333],[36.1666667,12.8333333],[33.8333334,12.8333333],[33.625,12.8333333],[33.625,18.8333333]],"sourceHandles":["1575F","15760","15761"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-39","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":40,"outlineFt":[[39.7083334,18.8333333],[39.7083334,12.8333333],[39.5,12.8333333],[37.1666667,12.8333333],[37.1666667,18.8333333]],"sourceHandles":["1575D","1575E","15762"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-40","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":41,"outlineFt":[[42.8333334,18.8333333],[42.8333334,12.8333333],[40.5,12.8333333],[40.2916667,12.8333333],[40.2916667,18.8333333]],"sourceHandles":["1578F","15790","15791"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-41","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":42,"outlineFt":[[46.375,18.8333333],[46.375,12.8333333],[46.1666667,12.8333333],[43.8333334,12.8333333],[43.8333334,18.8333333]],"sourceHandles":["1578D","1578E","15792"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-42","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":43,"outlineFt":[[49.5,18.8333333],[49.5,12.8333333],[47.1666667,12.8333333],[46.9583334,12.8333333],[46.9583334,18.8333333]],"sourceHandles":["157BF","157C0","157C1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-43","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":44,"outlineFt":[[53.0416667,18.8333333],[53.0416667,12.8333333],[52.8333334,12.8333333],[50.5,12.8333333],[50.5,18.8333333]],"sourceHandles":["157BD","157BE","157C2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-44","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":45,"outlineFt":[[56.1666667,18.8333333],[56.1666667,12.8333333],[53.8333334,12.8333333],[53.625,12.8333333],[53.625,18.8333333]],"sourceHandles":["157EF","157F0","157F1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-45","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":46,"outlineFt":[[59.7083334,18.8333333],[59.7083334,12.8333333],[59.5,12.8333333],[57.1666667,12.8333333],[57.1666667,18.8333333]],"sourceHandles":["157ED","157EE","157F2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-46","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":47,"outlineFt":[[62.8333334,18.8333333],[62.8333334,12.8333333],[60.5,12.8333333],[60.2916667,12.8333333],[60.2916667,18.8333333]],"sourceHandles":["1581F","15820","15821"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-47","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":48,"outlineFt":[[66.375,18.8333333],[66.375,12.8333333],[66.1666667,12.8333333],[63.8333334,12.8333333],[63.8333334,18.8333333]],"sourceHandles":["1581D","1581E","15822"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-48","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":49,"outlineFt":[[69.5,18.8333333],[69.5,12.8333333],[67.1666667,12.8333333],[66.9583334,12.8333333],[66.9583334,18.8333333]],"sourceHandles":["1584F","15850","15851"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-49","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":50,"outlineFt":[[73.0416667,18.8333333],[73.0416667,12.8333333],[72.8333334,12.8333333],[70.5,12.8333333],[70.5,18.8333333]],"sourceHandles":["1584D","1584E","15852"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-50","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":51,"outlineFt":[[76.1666667,18.8333333],[76.1666667,12.8333333],[73.8333334,12.8333333],[73.625,12.8333333],[73.625,18.8333333]],"sourceHandles":["1587F","15880","15881"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-51","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":52,"outlineFt":[[79.7083334,18.8333333],[79.7083334,12.8333333],[79.5,12.8333333],[77.1666667,12.8333333],[77.1666667,18.8333333]],"sourceHandles":["1587D","1587E","15882"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-52","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":53,"outlineFt":[[82.8333334,18.8333333],[82.8333334,12.8333333],[80.5,12.8333333],[80.2916667,12.8333333],[80.2916667,18.8333333]],"sourceHandles":["158AF","158B0","158B1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-53","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":54,"outlineFt":[[86.375,18.8333333],[86.375,12.8333333],[86.1666667,12.8333333],[83.8333334,12.8333333],[83.8333334,18.8333333]],"sourceHandles":["158AD","158AE","158B2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-54","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":55,"outlineFt":[[89.5,18.8333333],[89.5,12.8333333],[87.1666667,12.8333333],[86.9583334,12.8333333],[86.9583334,18.8333333]],"sourceHandles":["158DF","158E0","158E1"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-55","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":56,"outlineFt":[[93.0416667,18.8333333],[93.0416667,12.8333333],[92.8333334,12.8333333],[90.5,12.8333333],[90.5,18.8333333]],"sourceHandles":["158DD","158DE","158E2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-56","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":108,"bay":57,"outlineFt":[[96.1668614,18.8333333],[96.1668614,17.5049035],[96.1668614,17.5],[96.1668614,12.8333333],[93.8333334,12.8333333],[93.625,12.8333333],[93.625,18.8333333]],"sourceHandles":["15904","15905","15906"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-108-57","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":0,"outlineFt":[[-93.625,46.8333333],[-93.625,39.5833333],[-96.1666666,39.5833333],[-96.1666666,46.8333333]],"sourceHandles":["153C0","153CE","15978"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-0","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":1,"outlineFt":[[-90.5,46.8333333],[-90.5,39.5833333],[-93.0416666,39.5833333],[-93.0416666,46.8333333]],"sourceHandles":["153C8","153CF","153D0"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-1","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":2,"outlineFt":[[-86.9583333,46.8333333],[-86.9583333,39.5833333],[-89.5,39.5833333],[-89.5,46.8333333]],"sourceHandles":["153C9","153D1","153D2"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-2","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":3,"outlineFt":[[-83.8333333,46.8333333],[-83.8333333,39.5833333],[-86.375,39.5833333],[-86.375,46.8333333]],"sourceHandles":["153D3","15407","1590B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-3","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":4,"outlineFt":[[-80.2916666,46.8333333],[-80.2916666,39.5833333],[-82.8333333,39.5833333],[-82.8333333,46.8333333]],"sourceHandles":["15408","1590C","1590D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-4","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":5,"outlineFt":[[-77.1666666,46.8333333],[-77.1666666,39.5833333],[-79.7083333,39.5833333],[-79.7083333,46.8333333]],"sourceHandles":["15437","1590E","1590F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-5","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":6,"outlineFt":[[-73.625,46.8333333],[-73.625,39.5833333],[-76.1666666,39.5833333],[-76.1666666,46.8333333]],"sourceHandles":["15438","15910","15911"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-6","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":7,"outlineFt":[[-70.5,46.8333333],[-70.5,39.5833333],[-73.0416666,39.5833333],[-73.0416666,46.8333333]],"sourceHandles":["15467","15912","15913"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-7","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":8,"outlineFt":[[-66.9583333,46.8333333],[-66.9583333,39.5833333],[-69.5,39.5833333],[-69.5,46.8333333]],"sourceHandles":["15468","15914","15915"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-8","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":9,"outlineFt":[[-63.8333333,46.8333333],[-63.8333333,39.5833333],[-66.375,39.5833333],[-66.375,46.8333333]],"sourceHandles":["15497","15916","15917"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-9","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":10,"outlineFt":[[-60.2916666,46.8333333],[-60.2916666,39.5833333],[-62.8333333,39.5833333],[-62.8333333,46.8333333]],"sourceHandles":["15498","15918","15919"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-10","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":11,"outlineFt":[[-57.1666666,46.8333333],[-57.1666666,39.5833333],[-59.7083333,39.5833333],[-59.7083333,46.8333333]],"sourceHandles":["154C7","1591A","1591B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-11","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":12,"outlineFt":[[-53.625,46.8333333],[-53.625,39.5833333],[-56.1666666,39.5833333],[-56.1666666,46.8333333]],"sourceHandles":["154C8","1591C","1591D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-12","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":13,"outlineFt":[[-50.5,46.8333333],[-50.5,39.5833333],[-53.0416666,39.5833333],[-53.0416666,46.8333333]],"sourceHandles":["154F7","1591E","1591F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-13","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":14,"outlineFt":[[-46.9583333,46.8333333],[-46.9583333,39.5833333],[-49.5,39.5833333],[-49.5,46.8333333]],"sourceHandles":["154F8","15920","15921"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-14","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":15,"outlineFt":[[-43.8333333,46.8333333],[-43.8333333,39.5833333],[-46.375,39.5833333],[-46.375,46.8333333]],"sourceHandles":["15527","15922","15923"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-15","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":16,"outlineFt":[[-40.2916666,46.8333333],[-40.2916666,39.5833333],[-42.8333333,39.5833333],[-42.8333333,46.8333333]],"sourceHandles":["15528","15924","15925"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-16","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":17,"outlineFt":[[-37.1666666,46.8333333],[-37.1666666,39.5833333],[-39.7083333,39.5833333],[-39.7083333,46.8333333]],"sourceHandles":["15557","15926","15927"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-17","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":18,"outlineFt":[[-33.625,46.8333333],[-33.625,39.5833333],[-36.1666666,39.5833333],[-36.1666666,46.8333333]],"sourceHandles":["15558","15928","15929"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-18","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":19,"outlineFt":[[-30.5,46.8333333],[-30.5,39.5833333],[-33.0416666,39.5833333],[-33.0416666,46.8333333]],"sourceHandles":["15587","1592A","1592B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-19","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":20,"outlineFt":[[-26.9583333,46.8333333],[-26.9583333,39.5833333],[-29.5,39.5833333],[-29.5,46.8333333]],"sourceHandles":["15588","1592C","1592D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-20","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":21,"outlineFt":[[-23.8333333,46.8333333],[-23.8333333,39.5833333],[-26.375,39.5833333],[-26.375,46.8333333]],"sourceHandles":["155B7","1592E","1592F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-21","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":22,"outlineFt":[[-20.2916666,46.8333333],[-20.2916666,39.5833333],[-22.8333333,39.5833333],[-22.8333333,46.8333333]],"sourceHandles":["155B8","15930","15931"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-22","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":23,"outlineFt":[[-17.1666666,46.8333333],[-17.1666666,39.5833333],[-19.7083333,39.5833333],[-19.7083333,46.8333333]],"sourceHandles":["155E7","15932","15933"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-23","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":24,"outlineFt":[[-13.625,46.8333333],[-13.625,39.5833333],[-16.1666666,39.5833333],[-16.1666666,46.8333333]],"sourceHandles":["155E8","15934","15935"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-24","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":25,"outlineFt":[[-10.5,46.8333333],[-10.5,39.5833333],[-13.0416666,39.5833333],[-13.0416666,46.8333333]],"sourceHandles":["15617","15936","15937"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-25","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":26,"outlineFt":[[-6.9583333,46.8333333],[-6.9583333,39.5833333],[-9.5,39.5833333],[-9.5,46.8333333]],"sourceHandles":["15618","15938","15939"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-26","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":27,"outlineFt":[[-3.8333333,46.8333333],[-3.8333333,39.5833333],[-6.375,39.5833333],[-6.375,46.8333333]],"sourceHandles":["15647","1593A","1593B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-27","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":28,"outlineFt":[[-0.2916666,46.8333333],[-0.2916666,39.5833333],[-2.8333333,39.5833333],[-2.8333333,46.8333333]],"sourceHandles":["15648","1593C","1593D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-28","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":29,"outlineFt":[[2.8333334,46.8333333],[2.8333334,39.5833333],[0.2916667,39.5833333],[0.2916667,46.8333333]],"sourceHandles":["15677","1593E","1593F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-29","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":30,"outlineFt":[[6.375,46.8333333],[6.375,39.5833333],[3.8333334,39.5833333],[3.8333334,46.8333333]],"sourceHandles":["15678","15940","15941"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-30","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":31,"outlineFt":[[9.5,46.8333333],[9.5,39.5833333],[6.9583334,39.5833333],[6.9583334,46.8333333]],"sourceHandles":["156A7","15942","15943"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-31","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":32,"outlineFt":[[13.0416667,46.8333333],[13.0416667,39.5833333],[10.5,39.5833333],[10.5,46.8333333]],"sourceHandles":["156A8","15944","15945"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-32","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":33,"outlineFt":[[16.1666667,46.8333333],[16.1666667,39.5833333],[13.625,39.5833333],[13.625,46.8333333]],"sourceHandles":["156D7","15946","15947"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-33","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":34,"outlineFt":[[19.7083334,46.8333333],[19.7083334,39.5833333],[17.1666667,39.5833333],[17.1666667,46.8333333]],"sourceHandles":["156D8","15948","15949"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-34","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":35,"outlineFt":[[22.8333334,46.8333333],[22.8333334,39.5833333],[20.2916667,39.5833333],[20.2916667,46.8333333]],"sourceHandles":["15707","1594A","1594B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-35","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":36,"outlineFt":[[26.375,46.8333333],[26.375,39.5833333],[23.8333334,39.5833333],[23.8333334,46.8333333]],"sourceHandles":["15708","1594C","1594D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-36","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":37,"outlineFt":[[29.5,46.8333333],[29.5,39.5833333],[26.9583334,39.5833333],[26.9583334,46.8333333]],"sourceHandles":["15737","1594E","1594F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-37","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":38,"outlineFt":[[33.0416667,46.8333333],[33.0416667,39.5833333],[30.5,39.5833333],[30.5,46.8333333]],"sourceHandles":["15738","15950","15951"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-38","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":39,"outlineFt":[[36.1666667,46.8333333],[36.1666667,39.5833333],[33.625,39.5833333],[33.625,46.8333333]],"sourceHandles":["15767","15952","15953"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-39","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":40,"outlineFt":[[39.7083334,46.8333333],[39.7083334,39.5833333],[37.1666667,39.5833333],[37.1666667,46.8333333]],"sourceHandles":["15768","15954","15955"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-40","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":41,"outlineFt":[[42.8333334,46.8333333],[42.8333334,39.5833333],[40.2916667,39.5833333],[40.2916667,46.8333333]],"sourceHandles":["15797","15956","15957"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-41","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":42,"outlineFt":[[46.375,46.8333333],[46.375,39.5833333],[43.8333334,39.5833333],[43.8333334,46.8333333]],"sourceHandles":["15798","15958","15959"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-42","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":43,"outlineFt":[[49.5,46.8333333],[49.5,39.5833333],[46.9583334,39.5833333],[46.9583334,46.8333333]],"sourceHandles":["157C7","1595A","1595B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-43","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":44,"outlineFt":[[53.0416667,46.8333333],[53.0416667,39.5833333],[50.5,39.5833333],[50.5,46.8333333]],"sourceHandles":["157C8","1595C","1595D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-44","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":45,"outlineFt":[[56.1666667,46.8333333],[56.1666667,39.5833333],[53.625,39.5833333],[53.625,46.8333333]],"sourceHandles":["157F7","1595E","1595F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-45","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":46,"outlineFt":[[59.7083334,46.8333333],[59.7083334,39.5833333],[57.1666667,39.5833333],[57.1666667,46.8333333]],"sourceHandles":["157F8","15960","15961"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-46","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":47,"outlineFt":[[62.8333334,46.8333333],[62.8333334,39.5833333],[60.2916667,39.5833333],[60.2916667,46.8333333]],"sourceHandles":["15827","15962","15963"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-47","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":48,"outlineFt":[[66.375,46.8333333],[66.375,39.5833333],[63.8333334,39.5833333],[63.8333334,46.8333333]],"sourceHandles":["15828","15964","15965"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-48","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":49,"outlineFt":[[69.5,46.8333333],[69.5,39.5833333],[66.9583334,39.5833333],[66.9583334,46.8333333]],"sourceHandles":["15857","15966","15967"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-49","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":50,"outlineFt":[[73.0416667,46.8333333],[73.0416667,39.5833333],[70.5,39.5833333],[70.5,46.8333333]],"sourceHandles":["15858","15968","15969"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-50","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":51,"outlineFt":[[76.1666667,46.8333333],[76.1666667,39.5833333],[73.625,39.5833333],[73.625,46.8333333]],"sourceHandles":["15887","1596A","1596B"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-51","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":52,"outlineFt":[[79.7083334,46.8333333],[79.7083334,39.5833333],[77.1666667,39.5833333],[77.1666667,46.8333333]],"sourceHandles":["15888","1596C","1596D"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-52","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":53,"outlineFt":[[82.8333334,46.8333333],[82.8333334,39.5833333],[80.2916667,39.5833333],[80.2916667,46.8333333]],"sourceHandles":["158B7","1596E","1596F"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-53","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":54,"outlineFt":[[86.375,46.8333333],[86.375,39.5833333],[83.8333334,39.5833333],[83.8333334,46.8333333]],"sourceHandles":["158B8","15970","15971"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-54","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":55,"outlineFt":[[89.5,46.8333333],[89.5,39.5833333],[86.9583334,39.5833333],[86.9583334,46.8333333]],"sourceHandles":["158E7","15972","15973"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-55","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":56,"outlineFt":[[93.0416667,46.8333333],[93.0416667,39.5833333],[90.5,39.5833333],[90.5,46.8333333]],"sourceHandles":["158E8","15974","15975"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-56","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]},{"kind":"spandrel","floor":110,"bay":57,"outlineFt":[[96.1668614,46.8333333],[96.1668614,39.5833333],[93.625,39.5833333],[93.625,46.8333333]],"sourceHandles":["15976","15977"],"profileDescription":"Elevation band bounded by source S-Spandrels horizontal edges and adjacent column envelopes. Small drawing splice-line breaks closed; joint geometry not asserted.","id":"upper-exterior-2-west-spandrel-110-57","tower":2,"face":"west","depthFt":null,"render":true,"scope":"WTC2 shared-system reference from WTC1 trace","source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layers":["S-Spandrels","S-Columns"],"applicability":"WTC1 profile reused as a qualified WTC2 reference; NIST confirms the common system, not every WTC2 dimension"},"limitations":["Two-dimensional envelope only; fabrication section, normal depth, plate gauge and connection detail are not resolved."]}],"references":[{"id":"upper-exterior-1-north-roof-cap-reference","tower":1,"face":"north","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[104.4166667,49.0833333],[-104.4166667,49.0833333]],[[96.1666667,58.5833333],[-96.1666667,58.5833333]],[[93.3229167,46.8333333],[93.3229167,49.0833333]],[[89.9895833,46.8333333],[89.9895833,49.0833333]],[[86.65625,46.8333333],[86.65625,49.0833333]],[[83.3229167,46.8333333],[83.3229167,49.0833333]],[[79.9895833,46.8333333],[79.9895833,49.0833333]],[[76.65625,46.8333333],[76.65625,49.0833333]],[[73.3229167,46.8333333],[73.3229167,49.0833333]],[[69.9895833,46.8333333],[69.9895833,49.0833333]],[[66.65625,46.8333333],[66.65625,49.0833333]],[[63.3229167,46.8333333],[63.3229167,49.0833333]],[[59.9895833,46.8333333],[59.9895833,49.0833333]],[[56.65625,46.8333333],[56.65625,49.0833333]],[[53.3229167,46.8333333],[53.3229167,49.0833333]],[[49.9895833,46.8333333],[49.9895833,49.0833333]],[[46.65625,46.8333333],[46.65625,49.0833333]],[[43.3229167,46.8333333],[43.3229167,49.0833333]],[[39.9895833,46.8333333],[39.9895833,49.0833333]],[[36.65625,46.8333333],[36.65625,49.0833333]],[[33.3229167,46.8333333],[33.3229167,49.0833333]],[[29.9895833,46.8333333],[29.9895833,49.0833333]],[[26.65625,46.8333333],[26.65625,49.0833333]],[[23.3229167,46.8333333],[23.3229167,49.0833333]],[[19.9895833,46.8333333],[19.9895833,49.0833333]],[[16.65625,46.8333333],[16.65625,49.0833333]],[[13.3229167,46.8333333],[13.3229167,49.0833333]],[[9.9895833,46.8333333],[9.9895833,49.0833333]],[[6.65625,46.8333333],[6.65625,49.0833333]],[[3.3229167,46.8333333],[3.3229167,49.0833333]],[[-0.0104167,46.8333333],[-0.0104167,49.0833333]],[[-3.34375,46.8333333],[-3.34375,49.0833333]],[[-6.6770833,46.8333333],[-6.6770833,49.0833333]],[[-10.0104167,46.8333333],[-10.0104167,49.0833333]],[[-13.34375,46.8333333],[-13.34375,49.0833333]],[[-16.6770833,46.8333333],[-16.6770833,49.0833333]],[[-20.0104167,46.8333333],[-20.0104167,49.0833333]],[[-23.34375,46.8333333],[-23.34375,49.0833333]],[[-26.6770833,46.8333333],[-26.6770833,49.0833333]],[[-30.0104167,46.8333333],[-30.0104167,49.0833333]],[[-33.34375,46.8333333],[-33.34375,49.0833333]],[[-36.6770833,46.8333333],[-36.6770833,49.0833333]],[[-40.0104167,46.8333333],[-40.0104167,49.0833333]],[[-43.34375,46.8333333],[-43.34375,49.0833333]],[[-46.6770833,46.8333333],[-46.6770833,49.0833333]],[[-50.0104167,46.8333333],[-50.0104167,49.0833333]],[[-53.34375,46.8333333],[-53.34375,49.0833333]],[[-56.6770833,46.8333333],[-56.6770833,49.0833333]],[[-60.0104167,46.8333333],[-60.0104167,49.0833333]],[[-63.34375,46.8333333],[-63.34375,49.0833333]],[[-66.6770833,46.8333333],[-66.6770833,49.0833333]],[[-70.0104167,46.8333333],[-70.0104167,49.0833333]],[[-73.34375,46.8333333],[-73.34375,49.0833333]],[[-76.6770833,46.8333333],[-76.6770833,49.0833333]],[[-80.0104167,46.8333333],[-80.0104167,49.0833333]],[[-83.34375,46.8333333],[-83.34375,49.0833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[103.4583333,49.0833333],[96.1666667,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[93.3229167,49.0833333],[93.3229167,58.5833333]],[[89.9895833,49.0833333],[89.9895833,58.5833333]],[[86.65625,49.0833333],[86.65625,58.5833333]],[[83.3229167,49.0833333],[83.3229167,58.5833333]],[[79.9895833,49.0833333],[79.9895833,58.5833333]],[[76.65625,49.0833333],[76.65625,58.5833333]],[[73.3229167,49.0833333],[73.3229167,58.5833333]],[[69.9895833,49.0833333],[69.9895833,58.5833333]],[[66.65625,49.0833333],[66.65625,58.5833333]],[[63.3229167,49.0833333],[63.3229167,58.5833333]],[[59.9895833,49.0833333],[59.9895833,58.5833333]],[[56.65625,49.0833333],[56.65625,58.5833333]],[[53.3229167,49.0833333],[53.3229167,58.5833333]],[[49.9895833,49.0833333],[49.9895833,58.5833333]],[[46.65625,49.0833333],[46.65625,58.5833333]],[[43.3229167,49.0833333],[43.3229167,58.5833333]],[[39.9895833,49.0833333],[39.9895833,58.5833333]],[[36.65625,49.0833333],[36.65625,58.5833333]],[[33.3229167,49.0833333],[33.3229167,58.5833333]],[[29.9895833,49.0833333],[29.9895833,58.5833333]],[[26.65625,49.0833333],[26.65625,58.5833333]],[[23.3229167,49.0833333],[23.3229167,58.5833333]],[[19.9895833,49.0833333],[19.9895833,58.5833333]],[[16.65625,49.0833333],[16.65625,58.5833333]],[[13.3229167,49.0833333],[13.3229167,58.5833333]],[[9.9895833,49.0833333],[9.9895833,58.5833333]],[[6.65625,49.0833333],[6.65625,58.5833333]],[[3.3229167,49.0833333],[3.3229167,58.5833333]],[[-0.0104167,49.0833333],[-0.0104167,58.5833333]],[[-3.34375,49.0833333],[-3.34375,58.5833333]],[[-6.6770833,49.0833333],[-6.6770833,58.5833333]],[[-10.0104167,49.0833333],[-10.0104167,58.5833333]],[[-13.34375,49.0833333],[-13.34375,58.5833333]],[[-16.6770833,49.0833333],[-16.6770833,58.5833333]],[[-20.0104167,49.0833333],[-20.0104167,58.5833333]],[[-23.34375,49.0833333],[-23.34375,58.5833333]],[[-26.6770833,49.0833333],[-26.6770833,58.5833333]],[[-30.0104167,49.0833333],[-30.0104167,58.5833333]],[[-33.34375,49.0833333],[-33.34375,58.5833333]],[[-36.6770833,49.0833333],[-36.6770833,58.5833333]],[[-40.0104167,49.0833333],[-40.0104167,58.5833333]],[[-43.34375,49.0833333],[-43.34375,58.5833333]],[[-46.6770833,49.0833333],[-46.6770833,58.5833333]],[[-50.0104167,49.0833333],[-50.0104167,58.5833333]],[[-53.34375,49.0833333],[-53.34375,58.5833333]],[[-56.6770833,49.0833333],[-56.6770833,58.5833333]],[[-60.0104167,49.0833333],[-60.0104167,58.5833333]],[[-63.34375,49.0833333],[-63.34375,58.5833333]],[[-66.6770833,49.0833333],[-66.6770833,58.5833333]],[[-70.0104167,49.0833333],[-70.0104167,58.5833333]],[[-73.34375,49.0833333],[-73.34375,58.5833333]],[[-76.6770833,49.0833333],[-76.6770833,58.5833333]],[[-80.0104167,49.0833333],[-80.0104167,58.5833333]],[[-83.34375,49.0833333],[-83.34375,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-86.6770833,46.8333333],[-86.6770833,49.0833333]],[[-90.0104167,46.8333333],[-90.0104167,49.0833333]],[[-93.34375,46.8333333],[-93.34375,49.0833333]],[[-86.6770833,49.0833333],[-86.6770833,58.5833333]],[[-90.0104167,49.0833333],[-90.0104167,58.5833333]],[[-93.34375,49.0833333],[-93.34375,58.5833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]]],"sourceHandles":["B29A","B2A0","B2A1","B2A2","B2A3","B2A4","B2A5","B2A6","B2A7","B2A8","B2A9","B2AA","B2AB","B2AC","B2AD","B2AE","B2AF","B2B0","B2B1","B2B2","B2B3","B2B4","B2B5","B2B6","B2B7","B2B8","B2B9","B2BA","B2BB","B2BC","B2BD","B2BE","B2BF","B2C0","B2C1","B2C2","B2C3","B2C4","B2C5","B2C6","B2C7","B2C8","B2C9","B2CA","B2CB","B2CC","B2CD","B2CE","B2CF","B2D0","B2D1","B2D2","B2D3","B2D4","B2D5","B2D6","B2D8","B2D9","B2DA","B2DB","B2DC","B2DD","B2DE","B2DF","B2E0","B2E1","B2E2","B2E3","B2E4","B2E5","B2E6","B2E7","B2E8","B2E9","B2EA","B2EB","B2EC","B2ED","B2EE","B2EF","B2F0","B2F1","B2F2","B2F3","B2F4","B2F5","B2F6","B2F7","B2F8","B2F9","B2FA","B2FB","B2FC","B2FD","B2FE","B2FF","B300","B301","B302","B303","B304","B305","B306","B307","B308","B309","B30A","B30B","B30C","B30D","B30E","B30F","B310","B311","B31E","B31F","B320","B321","B322","B323","B324","B325","B326"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC1 CAD roof-cap elevation reference","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]},{"id":"upper-exterior-2-north-roof-cap-reference","tower":2,"face":"north","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[104.4166667,49.0833333],[-104.4166667,49.0833333]],[[96.1666667,58.5833333],[-96.1666667,58.5833333]],[[93.3229167,46.8333333],[93.3229167,49.0833333]],[[89.9895833,46.8333333],[89.9895833,49.0833333]],[[86.65625,46.8333333],[86.65625,49.0833333]],[[83.3229167,46.8333333],[83.3229167,49.0833333]],[[79.9895833,46.8333333],[79.9895833,49.0833333]],[[76.65625,46.8333333],[76.65625,49.0833333]],[[73.3229167,46.8333333],[73.3229167,49.0833333]],[[69.9895833,46.8333333],[69.9895833,49.0833333]],[[66.65625,46.8333333],[66.65625,49.0833333]],[[63.3229167,46.8333333],[63.3229167,49.0833333]],[[59.9895833,46.8333333],[59.9895833,49.0833333]],[[56.65625,46.8333333],[56.65625,49.0833333]],[[53.3229167,46.8333333],[53.3229167,49.0833333]],[[49.9895833,46.8333333],[49.9895833,49.0833333]],[[46.65625,46.8333333],[46.65625,49.0833333]],[[43.3229167,46.8333333],[43.3229167,49.0833333]],[[39.9895833,46.8333333],[39.9895833,49.0833333]],[[36.65625,46.8333333],[36.65625,49.0833333]],[[33.3229167,46.8333333],[33.3229167,49.0833333]],[[29.9895833,46.8333333],[29.9895833,49.0833333]],[[26.65625,46.8333333],[26.65625,49.0833333]],[[23.3229167,46.8333333],[23.3229167,49.0833333]],[[19.9895833,46.8333333],[19.9895833,49.0833333]],[[16.65625,46.8333333],[16.65625,49.0833333]],[[13.3229167,46.8333333],[13.3229167,49.0833333]],[[9.9895833,46.8333333],[9.9895833,49.0833333]],[[6.65625,46.8333333],[6.65625,49.0833333]],[[3.3229167,46.8333333],[3.3229167,49.0833333]],[[-0.0104167,46.8333333],[-0.0104167,49.0833333]],[[-3.34375,46.8333333],[-3.34375,49.0833333]],[[-6.6770833,46.8333333],[-6.6770833,49.0833333]],[[-10.0104167,46.8333333],[-10.0104167,49.0833333]],[[-13.34375,46.8333333],[-13.34375,49.0833333]],[[-16.6770833,46.8333333],[-16.6770833,49.0833333]],[[-20.0104167,46.8333333],[-20.0104167,49.0833333]],[[-23.34375,46.8333333],[-23.34375,49.0833333]],[[-26.6770833,46.8333333],[-26.6770833,49.0833333]],[[-30.0104167,46.8333333],[-30.0104167,49.0833333]],[[-33.34375,46.8333333],[-33.34375,49.0833333]],[[-36.6770833,46.8333333],[-36.6770833,49.0833333]],[[-40.0104167,46.8333333],[-40.0104167,49.0833333]],[[-43.34375,46.8333333],[-43.34375,49.0833333]],[[-46.6770833,46.8333333],[-46.6770833,49.0833333]],[[-50.0104167,46.8333333],[-50.0104167,49.0833333]],[[-53.34375,46.8333333],[-53.34375,49.0833333]],[[-56.6770833,46.8333333],[-56.6770833,49.0833333]],[[-60.0104167,46.8333333],[-60.0104167,49.0833333]],[[-63.34375,46.8333333],[-63.34375,49.0833333]],[[-66.6770833,46.8333333],[-66.6770833,49.0833333]],[[-70.0104167,46.8333333],[-70.0104167,49.0833333]],[[-73.34375,46.8333333],[-73.34375,49.0833333]],[[-76.6770833,46.8333333],[-76.6770833,49.0833333]],[[-80.0104167,46.8333333],[-80.0104167,49.0833333]],[[-83.34375,46.8333333],[-83.34375,49.0833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[103.4583333,49.0833333],[96.1666667,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[93.3229167,49.0833333],[93.3229167,58.5833333]],[[89.9895833,49.0833333],[89.9895833,58.5833333]],[[86.65625,49.0833333],[86.65625,58.5833333]],[[83.3229167,49.0833333],[83.3229167,58.5833333]],[[79.9895833,49.0833333],[79.9895833,58.5833333]],[[76.65625,49.0833333],[76.65625,58.5833333]],[[73.3229167,49.0833333],[73.3229167,58.5833333]],[[69.9895833,49.0833333],[69.9895833,58.5833333]],[[66.65625,49.0833333],[66.65625,58.5833333]],[[63.3229167,49.0833333],[63.3229167,58.5833333]],[[59.9895833,49.0833333],[59.9895833,58.5833333]],[[56.65625,49.0833333],[56.65625,58.5833333]],[[53.3229167,49.0833333],[53.3229167,58.5833333]],[[49.9895833,49.0833333],[49.9895833,58.5833333]],[[46.65625,49.0833333],[46.65625,58.5833333]],[[43.3229167,49.0833333],[43.3229167,58.5833333]],[[39.9895833,49.0833333],[39.9895833,58.5833333]],[[36.65625,49.0833333],[36.65625,58.5833333]],[[33.3229167,49.0833333],[33.3229167,58.5833333]],[[29.9895833,49.0833333],[29.9895833,58.5833333]],[[26.65625,49.0833333],[26.65625,58.5833333]],[[23.3229167,49.0833333],[23.3229167,58.5833333]],[[19.9895833,49.0833333],[19.9895833,58.5833333]],[[16.65625,49.0833333],[16.65625,58.5833333]],[[13.3229167,49.0833333],[13.3229167,58.5833333]],[[9.9895833,49.0833333],[9.9895833,58.5833333]],[[6.65625,49.0833333],[6.65625,58.5833333]],[[3.3229167,49.0833333],[3.3229167,58.5833333]],[[-0.0104167,49.0833333],[-0.0104167,58.5833333]],[[-3.34375,49.0833333],[-3.34375,58.5833333]],[[-6.6770833,49.0833333],[-6.6770833,58.5833333]],[[-10.0104167,49.0833333],[-10.0104167,58.5833333]],[[-13.34375,49.0833333],[-13.34375,58.5833333]],[[-16.6770833,49.0833333],[-16.6770833,58.5833333]],[[-20.0104167,49.0833333],[-20.0104167,58.5833333]],[[-23.34375,49.0833333],[-23.34375,58.5833333]],[[-26.6770833,49.0833333],[-26.6770833,58.5833333]],[[-30.0104167,49.0833333],[-30.0104167,58.5833333]],[[-33.34375,49.0833333],[-33.34375,58.5833333]],[[-36.6770833,49.0833333],[-36.6770833,58.5833333]],[[-40.0104167,49.0833333],[-40.0104167,58.5833333]],[[-43.34375,49.0833333],[-43.34375,58.5833333]],[[-46.6770833,49.0833333],[-46.6770833,58.5833333]],[[-50.0104167,49.0833333],[-50.0104167,58.5833333]],[[-53.34375,49.0833333],[-53.34375,58.5833333]],[[-56.6770833,49.0833333],[-56.6770833,58.5833333]],[[-60.0104167,49.0833333],[-60.0104167,58.5833333]],[[-63.34375,49.0833333],[-63.34375,58.5833333]],[[-66.6770833,49.0833333],[-66.6770833,58.5833333]],[[-70.0104167,49.0833333],[-70.0104167,58.5833333]],[[-73.34375,49.0833333],[-73.34375,58.5833333]],[[-76.6770833,49.0833333],[-76.6770833,58.5833333]],[[-80.0104167,49.0833333],[-80.0104167,58.5833333]],[[-83.34375,49.0833333],[-83.34375,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-86.6770833,46.8333333],[-86.6770833,49.0833333]],[[-90.0104167,46.8333333],[-90.0104167,49.0833333]],[[-93.34375,46.8333333],[-93.34375,49.0833333]],[[-86.6770833,49.0833333],[-86.6770833,58.5833333]],[[-90.0104167,49.0833333],[-90.0104167,58.5833333]],[[-93.34375,49.0833333],[-93.34375,58.5833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]]],"sourceHandles":["B29A","B2A0","B2A1","B2A2","B2A3","B2A4","B2A5","B2A6","B2A7","B2A8","B2A9","B2AA","B2AB","B2AC","B2AD","B2AE","B2AF","B2B0","B2B1","B2B2","B2B3","B2B4","B2B5","B2B6","B2B7","B2B8","B2B9","B2BA","B2BB","B2BC","B2BD","B2BE","B2BF","B2C0","B2C1","B2C2","B2C3","B2C4","B2C5","B2C6","B2C7","B2C8","B2C9","B2CA","B2CB","B2CC","B2CD","B2CE","B2CF","B2D0","B2D1","B2D2","B2D3","B2D4","B2D5","B2D6","B2D8","B2D9","B2DA","B2DB","B2DC","B2DD","B2DE","B2DF","B2E0","B2E1","B2E2","B2E3","B2E4","B2E5","B2E6","B2E7","B2E8","B2E9","B2EA","B2EB","B2EC","B2ED","B2EE","B2EF","B2F0","B2F1","B2F2","B2F3","B2F4","B2F5","B2F6","B2F7","B2F8","B2F9","B2FA","B2FB","B2FC","B2FD","B2FE","B2FF","B300","B301","B302","B303","B304","B305","B306","B307","B308","B309","B30A","B30B","B30C","B30D","B30E","B30F","B310","B311","B31E","B31F","B320","B321","B322","B323","B324","B325","B326"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC2 roof-cap reference reused from WTC1; exact WTC2 geometry unverified","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]},{"id":"upper-exterior-1-east-roof-cap-reference","tower":1,"face":"east","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[104.4166667,49.0833333],[-104.4166667,49.0833333]],[[96.1666667,58.5833333],[-96.1666667,58.5833333]],[[93.3229167,46.8333333],[93.3229167,49.0833333]],[[89.9895833,46.8333333],[89.9895833,49.0833333]],[[86.65625,46.8333333],[86.65625,49.0833333]],[[83.3229167,46.8333333],[83.3229167,49.0833333]],[[79.9895833,46.8333333],[79.9895833,49.0833333]],[[76.65625,46.8333333],[76.65625,49.0833333]],[[73.3229167,46.8333333],[73.3229167,49.0833333]],[[69.9895833,46.8333333],[69.9895833,49.0833333]],[[66.65625,46.8333333],[66.65625,49.0833333]],[[63.3229167,46.8333333],[63.3229167,49.0833333]],[[59.9895833,46.8333333],[59.9895833,49.0833333]],[[56.65625,46.8333333],[56.65625,49.0833333]],[[53.3229167,46.8333333],[53.3229167,49.0833333]],[[49.9895833,46.8333333],[49.9895833,49.0833333]],[[46.65625,46.8333333],[46.65625,49.0833333]],[[43.3229167,46.8333333],[43.3229167,49.0833333]],[[39.9895833,46.8333333],[39.9895833,49.0833333]],[[36.65625,46.8333333],[36.65625,49.0833333]],[[33.3229167,46.8333333],[33.3229167,49.0833333]],[[29.9895833,46.8333333],[29.9895833,49.0833333]],[[26.65625,46.8333333],[26.65625,49.0833333]],[[23.3229167,46.8333333],[23.3229167,49.0833333]],[[19.9895833,46.8333333],[19.9895833,49.0833333]],[[16.65625,46.8333333],[16.65625,49.0833333]],[[13.3229167,46.8333333],[13.3229167,49.0833333]],[[9.9895833,46.8333333],[9.9895833,49.0833333]],[[6.65625,46.8333333],[6.65625,49.0833333]],[[3.3229167,46.8333333],[3.3229167,49.0833333]],[[-0.0104167,46.8333333],[-0.0104167,49.0833333]],[[-3.34375,46.8333333],[-3.34375,49.0833333]],[[-6.6770833,46.8333333],[-6.6770833,49.0833333]],[[-10.0104167,46.8333333],[-10.0104167,49.0833333]],[[-13.34375,46.8333333],[-13.34375,49.0833333]],[[-16.6770833,46.8333333],[-16.6770833,49.0833333]],[[-20.0104167,46.8333333],[-20.0104167,49.0833333]],[[-23.34375,46.8333333],[-23.34375,49.0833333]],[[-26.6770833,46.8333333],[-26.6770833,49.0833333]],[[-30.0104167,46.8333333],[-30.0104167,49.0833333]],[[-33.34375,46.8333333],[-33.34375,49.0833333]],[[-36.6770833,46.8333333],[-36.6770833,49.0833333]],[[-40.0104167,46.8333333],[-40.0104167,49.0833333]],[[-43.34375,46.8333333],[-43.34375,49.0833333]],[[-46.6770833,46.8333333],[-46.6770833,49.0833333]],[[-50.0104167,46.8333333],[-50.0104167,49.0833333]],[[-53.34375,46.8333333],[-53.34375,49.0833333]],[[-56.6770833,46.8333333],[-56.6770833,49.0833333]],[[-60.0104167,46.8333333],[-60.0104167,49.0833333]],[[-63.34375,46.8333333],[-63.34375,49.0833333]],[[-66.6770833,46.8333333],[-66.6770833,49.0833333]],[[-70.0104167,46.8333333],[-70.0104167,49.0833333]],[[-73.34375,46.8333333],[-73.34375,49.0833333]],[[-76.6770833,46.8333333],[-76.6770833,49.0833333]],[[-80.0104167,46.8333333],[-80.0104167,49.0833333]],[[-83.34375,46.8333333],[-83.34375,49.0833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[103.4583333,49.0833333],[96.1666667,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[93.3229167,49.0833333],[93.3229167,58.5833333]],[[89.9895833,49.0833333],[89.9895833,58.5833333]],[[86.65625,49.0833333],[86.65625,58.5833333]],[[83.3229167,49.0833333],[83.3229167,58.5833333]],[[79.9895833,49.0833333],[79.9895833,58.5833333]],[[76.65625,49.0833333],[76.65625,58.5833333]],[[73.3229167,49.0833333],[73.3229167,58.5833333]],[[69.9895833,49.0833333],[69.9895833,58.5833333]],[[66.65625,49.0833333],[66.65625,58.5833333]],[[63.3229167,49.0833333],[63.3229167,58.5833333]],[[59.9895833,49.0833333],[59.9895833,58.5833333]],[[56.65625,49.0833333],[56.65625,58.5833333]],[[53.3229167,49.0833333],[53.3229167,58.5833333]],[[49.9895833,49.0833333],[49.9895833,58.5833333]],[[46.65625,49.0833333],[46.65625,58.5833333]],[[43.3229167,49.0833333],[43.3229167,58.5833333]],[[39.9895833,49.0833333],[39.9895833,58.5833333]],[[36.65625,49.0833333],[36.65625,58.5833333]],[[33.3229167,49.0833333],[33.3229167,58.5833333]],[[29.9895833,49.0833333],[29.9895833,58.5833333]],[[26.65625,49.0833333],[26.65625,58.5833333]],[[23.3229167,49.0833333],[23.3229167,58.5833333]],[[19.9895833,49.0833333],[19.9895833,58.5833333]],[[16.65625,49.0833333],[16.65625,58.5833333]],[[13.3229167,49.0833333],[13.3229167,58.5833333]],[[9.9895833,49.0833333],[9.9895833,58.5833333]],[[6.65625,49.0833333],[6.65625,58.5833333]],[[3.3229167,49.0833333],[3.3229167,58.5833333]],[[-0.0104167,49.0833333],[-0.0104167,58.5833333]],[[-3.34375,49.0833333],[-3.34375,58.5833333]],[[-6.6770833,49.0833333],[-6.6770833,58.5833333]],[[-10.0104167,49.0833333],[-10.0104167,58.5833333]],[[-13.34375,49.0833333],[-13.34375,58.5833333]],[[-16.6770833,49.0833333],[-16.6770833,58.5833333]],[[-20.0104167,49.0833333],[-20.0104167,58.5833333]],[[-23.34375,49.0833333],[-23.34375,58.5833333]],[[-26.6770833,49.0833333],[-26.6770833,58.5833333]],[[-30.0104167,49.0833333],[-30.0104167,58.5833333]],[[-33.34375,49.0833333],[-33.34375,58.5833333]],[[-36.6770833,49.0833333],[-36.6770833,58.5833333]],[[-40.0104167,49.0833333],[-40.0104167,58.5833333]],[[-43.34375,49.0833333],[-43.34375,58.5833333]],[[-46.6770833,49.0833333],[-46.6770833,58.5833333]],[[-50.0104167,49.0833333],[-50.0104167,58.5833333]],[[-53.34375,49.0833333],[-53.34375,58.5833333]],[[-56.6770833,49.0833333],[-56.6770833,58.5833333]],[[-60.0104167,49.0833333],[-60.0104167,58.5833333]],[[-63.34375,49.0833333],[-63.34375,58.5833333]],[[-66.6770833,49.0833333],[-66.6770833,58.5833333]],[[-70.0104167,49.0833333],[-70.0104167,58.5833333]],[[-73.34375,49.0833333],[-73.34375,58.5833333]],[[-76.6770833,49.0833333],[-76.6770833,58.5833333]],[[-80.0104167,49.0833333],[-80.0104167,58.5833333]],[[-83.34375,49.0833333],[-83.34375,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-86.6770833,46.8333333],[-86.6770833,49.0833333]],[[-90.0104167,46.8333333],[-90.0104167,49.0833333]],[[-93.34375,46.8333333],[-93.34375,49.0833333]],[[-86.6770833,49.0833333],[-86.6770833,58.5833333]],[[-90.0104167,49.0833333],[-90.0104167,58.5833333]],[[-93.34375,49.0833333],[-93.34375,58.5833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]]],"sourceHandles":["28DBC","28DBD","28DBE","28DBF","28DC0","28DC1","28DC2","28DC3","28DC4","28DC5","28DC6","28DC7","28DC8","28DC9","28DCA","28DCB","28DCC","28DCD","28DCE","28DCF","28DD0","28DD1","28DD2","28DD3","28DD4","28DD5","28DD6","28DD7","28DD8","28DD9","28DDA","28DDB","28DDC","28DDD","28DDE","28DDF","28DE0","28DE1","28DE2","28DE3","28DE4","28DE5","28DE6","28DE7","28DE8","28DE9","28DEA","28DEB","28DEC","28DED","28DEE","28DEF","28DF0","28DF1","28DF2","28DF3","28DF4","28DF5","28DF6","28DF7","28DF8","28DF9","28DFA","28DFB","28DFC","28DFD","28DFE","28DFF","28E00","28E01","28E02","28E03","28E04","28E05","28E06","28E07","28E08","28E09","28E0A","28E0B","28E0C","28E0D","28E0E","28E0F","28E10","28E11","28E12","28E13","28E14","28E15","28E16","28E17","28E18","28E19","28E1A","28E1B","28E1C","28E1D","28E1E","28E1F","28E20","28E21","28E22","28E23","28E24","28E25","28E26","28E27","28E28","28E29","28E2A","28E2B","28E2C","28E2D","28E2E","28E2F","28E30","28E31","28E32","28E33","28E34","28E35","28E36"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC1 CAD roof-cap elevation reference","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]},{"id":"upper-exterior-2-east-roof-cap-reference","tower":2,"face":"east","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[104.4166667,49.0833333],[-104.4166667,49.0833333]],[[96.1666667,58.5833333],[-96.1666667,58.5833333]],[[93.3229167,46.8333333],[93.3229167,49.0833333]],[[89.9895833,46.8333333],[89.9895833,49.0833333]],[[86.65625,46.8333333],[86.65625,49.0833333]],[[83.3229167,46.8333333],[83.3229167,49.0833333]],[[79.9895833,46.8333333],[79.9895833,49.0833333]],[[76.65625,46.8333333],[76.65625,49.0833333]],[[73.3229167,46.8333333],[73.3229167,49.0833333]],[[69.9895833,46.8333333],[69.9895833,49.0833333]],[[66.65625,46.8333333],[66.65625,49.0833333]],[[63.3229167,46.8333333],[63.3229167,49.0833333]],[[59.9895833,46.8333333],[59.9895833,49.0833333]],[[56.65625,46.8333333],[56.65625,49.0833333]],[[53.3229167,46.8333333],[53.3229167,49.0833333]],[[49.9895833,46.8333333],[49.9895833,49.0833333]],[[46.65625,46.8333333],[46.65625,49.0833333]],[[43.3229167,46.8333333],[43.3229167,49.0833333]],[[39.9895833,46.8333333],[39.9895833,49.0833333]],[[36.65625,46.8333333],[36.65625,49.0833333]],[[33.3229167,46.8333333],[33.3229167,49.0833333]],[[29.9895833,46.8333333],[29.9895833,49.0833333]],[[26.65625,46.8333333],[26.65625,49.0833333]],[[23.3229167,46.8333333],[23.3229167,49.0833333]],[[19.9895833,46.8333333],[19.9895833,49.0833333]],[[16.65625,46.8333333],[16.65625,49.0833333]],[[13.3229167,46.8333333],[13.3229167,49.0833333]],[[9.9895833,46.8333333],[9.9895833,49.0833333]],[[6.65625,46.8333333],[6.65625,49.0833333]],[[3.3229167,46.8333333],[3.3229167,49.0833333]],[[-0.0104167,46.8333333],[-0.0104167,49.0833333]],[[-3.34375,46.8333333],[-3.34375,49.0833333]],[[-6.6770833,46.8333333],[-6.6770833,49.0833333]],[[-10.0104167,46.8333333],[-10.0104167,49.0833333]],[[-13.34375,46.8333333],[-13.34375,49.0833333]],[[-16.6770833,46.8333333],[-16.6770833,49.0833333]],[[-20.0104167,46.8333333],[-20.0104167,49.0833333]],[[-23.34375,46.8333333],[-23.34375,49.0833333]],[[-26.6770833,46.8333333],[-26.6770833,49.0833333]],[[-30.0104167,46.8333333],[-30.0104167,49.0833333]],[[-33.34375,46.8333333],[-33.34375,49.0833333]],[[-36.6770833,46.8333333],[-36.6770833,49.0833333]],[[-40.0104167,46.8333333],[-40.0104167,49.0833333]],[[-43.34375,46.8333333],[-43.34375,49.0833333]],[[-46.6770833,46.8333333],[-46.6770833,49.0833333]],[[-50.0104167,46.8333333],[-50.0104167,49.0833333]],[[-53.34375,46.8333333],[-53.34375,49.0833333]],[[-56.6770833,46.8333333],[-56.6770833,49.0833333]],[[-60.0104167,46.8333333],[-60.0104167,49.0833333]],[[-63.34375,46.8333333],[-63.34375,49.0833333]],[[-66.6770833,46.8333333],[-66.6770833,49.0833333]],[[-70.0104167,46.8333333],[-70.0104167,49.0833333]],[[-73.34375,46.8333333],[-73.34375,49.0833333]],[[-76.6770833,46.8333333],[-76.6770833,49.0833333]],[[-80.0104167,46.8333333],[-80.0104167,49.0833333]],[[-83.34375,46.8333333],[-83.34375,49.0833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[103.4583333,49.0833333],[96.1666667,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[93.3229167,49.0833333],[93.3229167,58.5833333]],[[89.9895833,49.0833333],[89.9895833,58.5833333]],[[86.65625,49.0833333],[86.65625,58.5833333]],[[83.3229167,49.0833333],[83.3229167,58.5833333]],[[79.9895833,49.0833333],[79.9895833,58.5833333]],[[76.65625,49.0833333],[76.65625,58.5833333]],[[73.3229167,49.0833333],[73.3229167,58.5833333]],[[69.9895833,49.0833333],[69.9895833,58.5833333]],[[66.65625,49.0833333],[66.65625,58.5833333]],[[63.3229167,49.0833333],[63.3229167,58.5833333]],[[59.9895833,49.0833333],[59.9895833,58.5833333]],[[56.65625,49.0833333],[56.65625,58.5833333]],[[53.3229167,49.0833333],[53.3229167,58.5833333]],[[49.9895833,49.0833333],[49.9895833,58.5833333]],[[46.65625,49.0833333],[46.65625,58.5833333]],[[43.3229167,49.0833333],[43.3229167,58.5833333]],[[39.9895833,49.0833333],[39.9895833,58.5833333]],[[36.65625,49.0833333],[36.65625,58.5833333]],[[33.3229167,49.0833333],[33.3229167,58.5833333]],[[29.9895833,49.0833333],[29.9895833,58.5833333]],[[26.65625,49.0833333],[26.65625,58.5833333]],[[23.3229167,49.0833333],[23.3229167,58.5833333]],[[19.9895833,49.0833333],[19.9895833,58.5833333]],[[16.65625,49.0833333],[16.65625,58.5833333]],[[13.3229167,49.0833333],[13.3229167,58.5833333]],[[9.9895833,49.0833333],[9.9895833,58.5833333]],[[6.65625,49.0833333],[6.65625,58.5833333]],[[3.3229167,49.0833333],[3.3229167,58.5833333]],[[-0.0104167,49.0833333],[-0.0104167,58.5833333]],[[-3.34375,49.0833333],[-3.34375,58.5833333]],[[-6.6770833,49.0833333],[-6.6770833,58.5833333]],[[-10.0104167,49.0833333],[-10.0104167,58.5833333]],[[-13.34375,49.0833333],[-13.34375,58.5833333]],[[-16.6770833,49.0833333],[-16.6770833,58.5833333]],[[-20.0104167,49.0833333],[-20.0104167,58.5833333]],[[-23.34375,49.0833333],[-23.34375,58.5833333]],[[-26.6770833,49.0833333],[-26.6770833,58.5833333]],[[-30.0104167,49.0833333],[-30.0104167,58.5833333]],[[-33.34375,49.0833333],[-33.34375,58.5833333]],[[-36.6770833,49.0833333],[-36.6770833,58.5833333]],[[-40.0104167,49.0833333],[-40.0104167,58.5833333]],[[-43.34375,49.0833333],[-43.34375,58.5833333]],[[-46.6770833,49.0833333],[-46.6770833,58.5833333]],[[-50.0104167,49.0833333],[-50.0104167,58.5833333]],[[-53.34375,49.0833333],[-53.34375,58.5833333]],[[-56.6770833,49.0833333],[-56.6770833,58.5833333]],[[-60.0104167,49.0833333],[-60.0104167,58.5833333]],[[-63.34375,49.0833333],[-63.34375,58.5833333]],[[-66.6770833,49.0833333],[-66.6770833,58.5833333]],[[-70.0104167,49.0833333],[-70.0104167,58.5833333]],[[-73.34375,49.0833333],[-73.34375,58.5833333]],[[-76.6770833,49.0833333],[-76.6770833,58.5833333]],[[-80.0104167,49.0833333],[-80.0104167,58.5833333]],[[-83.34375,49.0833333],[-83.34375,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-86.6770833,46.8333333],[-86.6770833,49.0833333]],[[-90.0104167,46.8333333],[-90.0104167,49.0833333]],[[-93.34375,46.8333333],[-93.34375,49.0833333]],[[-86.6770833,49.0833333],[-86.6770833,58.5833333]],[[-90.0104167,49.0833333],[-90.0104167,58.5833333]],[[-93.34375,49.0833333],[-93.34375,58.5833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]]],"sourceHandles":["28DBC","28DBD","28DBE","28DBF","28DC0","28DC1","28DC2","28DC3","28DC4","28DC5","28DC6","28DC7","28DC8","28DC9","28DCA","28DCB","28DCC","28DCD","28DCE","28DCF","28DD0","28DD1","28DD2","28DD3","28DD4","28DD5","28DD6","28DD7","28DD8","28DD9","28DDA","28DDB","28DDC","28DDD","28DDE","28DDF","28DE0","28DE1","28DE2","28DE3","28DE4","28DE5","28DE6","28DE7","28DE8","28DE9","28DEA","28DEB","28DEC","28DED","28DEE","28DEF","28DF0","28DF1","28DF2","28DF3","28DF4","28DF5","28DF6","28DF7","28DF8","28DF9","28DFA","28DFB","28DFC","28DFD","28DFE","28DFF","28E00","28E01","28E02","28E03","28E04","28E05","28E06","28E07","28E08","28E09","28E0A","28E0B","28E0C","28E0D","28E0E","28E0F","28E10","28E11","28E12","28E13","28E14","28E15","28E16","28E17","28E18","28E19","28E1A","28E1B","28E1C","28E1D","28E1E","28E1F","28E20","28E21","28E22","28E23","28E24","28E25","28E26","28E27","28E28","28E29","28E2A","28E2B","28E2C","28E2D","28E2E","28E2F","28E30","28E31","28E32","28E33","28E34","28E35","28E36"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC2 roof-cap reference reused from WTC1; exact WTC2 geometry unverified","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]},{"id":"upper-exterior-1-south-roof-cap-reference","tower":1,"face":"south","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[-104.4166667,49.0833333],[104.4166667,49.0833333]],[[-96.1666667,58.5833333],[96.1666667,58.5833333]],[[-93.3229167,46.8333333],[-93.3229167,49.0833333]],[[-89.9895833,46.8333333],[-89.9895833,49.0833333]],[[-86.65625,46.8333333],[-86.65625,49.0833333]],[[-83.3229167,46.8333333],[-83.3229167,49.0833333]],[[-79.9895833,46.8333333],[-79.9895833,49.0833333]],[[-76.65625,46.8333333],[-76.65625,49.0833333]],[[-73.3229167,46.8333333],[-73.3229167,49.0833333]],[[-69.9895833,46.8333333],[-69.9895833,49.0833333]],[[-66.65625,46.8333333],[-66.65625,49.0833333]],[[-63.3229167,46.8333333],[-63.3229167,49.0833333]],[[-59.9895833,46.8333333],[-59.9895833,49.0833333]],[[-56.65625,46.8333333],[-56.65625,49.0833333]],[[-53.3229167,46.8333333],[-53.3229167,49.0833333]],[[-49.9895833,46.8333333],[-49.9895833,49.0833333]],[[-46.65625,46.8333333],[-46.65625,49.0833333]],[[-43.3229167,46.8333333],[-43.3229167,49.0833333]],[[-39.9895833,46.8333333],[-39.9895833,49.0833333]],[[-36.65625,46.8333333],[-36.65625,49.0833333]],[[-33.3229167,46.8333333],[-33.3229167,49.0833333]],[[-29.9895833,46.8333333],[-29.9895833,49.0833333]],[[-26.65625,46.8333333],[-26.65625,49.0833333]],[[-23.3229167,46.8333333],[-23.3229167,49.0833333]],[[-19.9895833,46.8333333],[-19.9895833,49.0833333]],[[-16.65625,46.8333333],[-16.65625,49.0833333]],[[-13.3229167,46.8333333],[-13.3229167,49.0833333]],[[-9.9895833,46.8333333],[-9.9895833,49.0833333]],[[-6.65625,46.8333333],[-6.65625,49.0833333]],[[-3.3229167,46.8333333],[-3.3229167,49.0833333]],[[0.0104167,46.8333333],[0.0104167,49.0833333]],[[3.34375,46.8333333],[3.34375,49.0833333]],[[6.6770833,46.8333333],[6.6770833,49.0833333]],[[10.0104167,46.8333333],[10.0104167,49.0833333]],[[13.34375,46.8333333],[13.34375,49.0833333]],[[16.6770833,46.8333333],[16.6770833,49.0833333]],[[20.0104167,46.8333333],[20.0104167,49.0833333]],[[23.34375,46.8333333],[23.34375,49.0833333]],[[26.6770833,46.8333333],[26.6770833,49.0833333]],[[30.0104167,46.8333333],[30.0104167,49.0833333]],[[33.34375,46.8333333],[33.34375,49.0833333]],[[36.6770833,46.8333333],[36.6770833,49.0833333]],[[40.0104167,46.8333333],[40.0104167,49.0833333]],[[43.34375,46.8333333],[43.34375,49.0833333]],[[46.6770833,46.8333333],[46.6770833,49.0833333]],[[50.0104167,46.8333333],[50.0104167,49.0833333]],[[53.34375,46.8333333],[53.34375,49.0833333]],[[56.6770833,46.8333333],[56.6770833,49.0833333]],[[60.0104167,46.8333333],[60.0104167,49.0833333]],[[63.34375,46.8333333],[63.34375,49.0833333]],[[66.6770833,46.8333333],[66.6770833,49.0833333]],[[70.0104167,46.8333333],[70.0104167,49.0833333]],[[73.34375,46.8333333],[73.34375,49.0833333]],[[76.6770833,46.8333333],[76.6770833,49.0833333]],[[80.0104167,46.8333333],[80.0104167,49.0833333]],[[83.34375,46.8333333],[83.34375,49.0833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-103.4583333,49.0833333],[-96.1666667,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-93.3229167,49.0833333],[-93.3229167,58.5833333]],[[-89.9895833,49.0833333],[-89.9895833,58.5833333]],[[-86.65625,49.0833333],[-86.65625,58.5833333]],[[-83.3229167,49.0833333],[-83.3229167,58.5833333]],[[-79.9895833,49.0833333],[-79.9895833,58.5833333]],[[-76.65625,49.0833333],[-76.65625,58.5833333]],[[-73.3229167,49.0833333],[-73.3229167,58.5833333]],[[-69.9895833,49.0833333],[-69.9895833,58.5833333]],[[-66.65625,49.0833333],[-66.65625,58.5833333]],[[-63.3229167,49.0833333],[-63.3229167,58.5833333]],[[-59.9895833,49.0833333],[-59.9895833,58.5833333]],[[-56.65625,49.0833333],[-56.65625,58.5833333]],[[-53.3229167,49.0833333],[-53.3229167,58.5833333]],[[-49.9895833,49.0833333],[-49.9895833,58.5833333]],[[-46.65625,49.0833333],[-46.65625,58.5833333]],[[-43.3229167,49.0833333],[-43.3229167,58.5833333]],[[-39.9895833,49.0833333],[-39.9895833,58.5833333]],[[-36.65625,49.0833333],[-36.65625,58.5833333]],[[-33.3229167,49.0833333],[-33.3229167,58.5833333]],[[-29.9895833,49.0833333],[-29.9895833,58.5833333]],[[-26.65625,49.0833333],[-26.65625,58.5833333]],[[-23.3229167,49.0833333],[-23.3229167,58.5833333]],[[-19.9895833,49.0833333],[-19.9895833,58.5833333]],[[-16.65625,49.0833333],[-16.65625,58.5833333]],[[-13.3229167,49.0833333],[-13.3229167,58.5833333]],[[-9.9895833,49.0833333],[-9.9895833,58.5833333]],[[-6.65625,49.0833333],[-6.65625,58.5833333]],[[-3.3229167,49.0833333],[-3.3229167,58.5833333]],[[0.0104167,49.0833333],[0.0104167,58.5833333]],[[3.34375,49.0833333],[3.34375,58.5833333]],[[6.6770833,49.0833333],[6.6770833,58.5833333]],[[10.0104167,49.0833333],[10.0104167,58.5833333]],[[13.34375,49.0833333],[13.34375,58.5833333]],[[16.6770833,49.0833333],[16.6770833,58.5833333]],[[20.0104167,49.0833333],[20.0104167,58.5833333]],[[23.34375,49.0833333],[23.34375,58.5833333]],[[26.6770833,49.0833333],[26.6770833,58.5833333]],[[30.0104167,49.0833333],[30.0104167,58.5833333]],[[33.34375,49.0833333],[33.34375,58.5833333]],[[36.6770833,49.0833333],[36.6770833,58.5833333]],[[40.0104167,49.0833333],[40.0104167,58.5833333]],[[43.34375,49.0833333],[43.34375,58.5833333]],[[46.6770833,49.0833333],[46.6770833,58.5833333]],[[50.0104167,49.0833333],[50.0104167,58.5833333]],[[53.34375,49.0833333],[53.34375,58.5833333]],[[56.6770833,49.0833333],[56.6770833,58.5833333]],[[60.0104167,49.0833333],[60.0104167,58.5833333]],[[63.34375,49.0833333],[63.34375,58.5833333]],[[66.6770833,49.0833333],[66.6770833,58.5833333]],[[70.0104167,49.0833333],[70.0104167,58.5833333]],[[73.34375,49.0833333],[73.34375,58.5833333]],[[76.6770833,49.0833333],[76.6770833,58.5833333]],[[80.0104167,49.0833333],[80.0104167,58.5833333]],[[83.34375,49.0833333],[83.34375,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[86.6770833,46.8333333],[86.6770833,49.0833333]],[[90.0104167,46.8333333],[90.0104167,49.0833333]],[[93.34375,46.8333333],[93.34375,49.0833333]],[[86.6770833,49.0833333],[86.6770833,58.5833333]],[[90.0104167,49.0833333],[90.0104167,58.5833333]],[[93.34375,49.0833333],[93.34375,58.5833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]]],"sourceHandles":["1F39B","1F39C","1F39D","1F39E","1F39F","1F3A0","1F3A1","1F3A2","1F3A3","1F3A4","1F3A5","1F3A6","1F3A7","1F3A8","1F3A9","1F3AA","1F3AB","1F3AC","1F3AD","1F3AE","1F3AF","1F3B0","1F3B1","1F3B2","1F3B3","1F3B4","1F3B5","1F3B6","1F3B7","1F3B8","1F3B9","1F3BA","1F3BB","1F3BC","1F3BD","1F3BE","1F3BF","1F3C0","1F3C1","1F3C2","1F3C3","1F3C4","1F3C5","1F3C6","1F3C7","1F3C8","1F3C9","1F3CA","1F3CB","1F3CC","1F3CD","1F3CE","1F3CF","1F3D0","1F3D1","1F3D2","1F3D3","1F3D4","1F3D5","1F3D6","1F3D7","1F3D8","1F3D9","1F3DA","1F3DB","1F3DC","1F3DD","1F3DE","1F3DF","1F3E0","1F3E1","1F3E2","1F3E3","1F3E4","1F3E5","1F3E6","1F3E7","1F3E8","1F3E9","1F3EA","1F3EB","1F3EC","1F3ED","1F3EE","1F3EF","1F3F0","1F3F1","1F3F2","1F3F3","1F3F4","1F3F5","1F3F6","1F3F7","1F3F8","1F3F9","1F3FA","1F3FB","1F3FC","1F3FD","1F3FE","1F3FF","1F400","1F401","1F402","1F403","1F404","1F405","1F406","1F407","1F408","1F409","1F40A","1F40B","1F40C","1F40D","1F40E","1F40F","1F410","1F411","1F412","1F413","1F414","1F415"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC1 CAD roof-cap elevation reference","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]},{"id":"upper-exterior-2-south-roof-cap-reference","tower":2,"face":"south","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[-104.4166667,49.0833333],[104.4166667,49.0833333]],[[-96.1666667,58.5833333],[96.1666667,58.5833333]],[[-93.3229167,46.8333333],[-93.3229167,49.0833333]],[[-89.9895833,46.8333333],[-89.9895833,49.0833333]],[[-86.65625,46.8333333],[-86.65625,49.0833333]],[[-83.3229167,46.8333333],[-83.3229167,49.0833333]],[[-79.9895833,46.8333333],[-79.9895833,49.0833333]],[[-76.65625,46.8333333],[-76.65625,49.0833333]],[[-73.3229167,46.8333333],[-73.3229167,49.0833333]],[[-69.9895833,46.8333333],[-69.9895833,49.0833333]],[[-66.65625,46.8333333],[-66.65625,49.0833333]],[[-63.3229167,46.8333333],[-63.3229167,49.0833333]],[[-59.9895833,46.8333333],[-59.9895833,49.0833333]],[[-56.65625,46.8333333],[-56.65625,49.0833333]],[[-53.3229167,46.8333333],[-53.3229167,49.0833333]],[[-49.9895833,46.8333333],[-49.9895833,49.0833333]],[[-46.65625,46.8333333],[-46.65625,49.0833333]],[[-43.3229167,46.8333333],[-43.3229167,49.0833333]],[[-39.9895833,46.8333333],[-39.9895833,49.0833333]],[[-36.65625,46.8333333],[-36.65625,49.0833333]],[[-33.3229167,46.8333333],[-33.3229167,49.0833333]],[[-29.9895833,46.8333333],[-29.9895833,49.0833333]],[[-26.65625,46.8333333],[-26.65625,49.0833333]],[[-23.3229167,46.8333333],[-23.3229167,49.0833333]],[[-19.9895833,46.8333333],[-19.9895833,49.0833333]],[[-16.65625,46.8333333],[-16.65625,49.0833333]],[[-13.3229167,46.8333333],[-13.3229167,49.0833333]],[[-9.9895833,46.8333333],[-9.9895833,49.0833333]],[[-6.65625,46.8333333],[-6.65625,49.0833333]],[[-3.3229167,46.8333333],[-3.3229167,49.0833333]],[[0.0104167,46.8333333],[0.0104167,49.0833333]],[[3.34375,46.8333333],[3.34375,49.0833333]],[[6.6770833,46.8333333],[6.6770833,49.0833333]],[[10.0104167,46.8333333],[10.0104167,49.0833333]],[[13.34375,46.8333333],[13.34375,49.0833333]],[[16.6770833,46.8333333],[16.6770833,49.0833333]],[[20.0104167,46.8333333],[20.0104167,49.0833333]],[[23.34375,46.8333333],[23.34375,49.0833333]],[[26.6770833,46.8333333],[26.6770833,49.0833333]],[[30.0104167,46.8333333],[30.0104167,49.0833333]],[[33.34375,46.8333333],[33.34375,49.0833333]],[[36.6770833,46.8333333],[36.6770833,49.0833333]],[[40.0104167,46.8333333],[40.0104167,49.0833333]],[[43.34375,46.8333333],[43.34375,49.0833333]],[[46.6770833,46.8333333],[46.6770833,49.0833333]],[[50.0104167,46.8333333],[50.0104167,49.0833333]],[[53.34375,46.8333333],[53.34375,49.0833333]],[[56.6770833,46.8333333],[56.6770833,49.0833333]],[[60.0104167,46.8333333],[60.0104167,49.0833333]],[[63.34375,46.8333333],[63.34375,49.0833333]],[[66.6770833,46.8333333],[66.6770833,49.0833333]],[[70.0104167,46.8333333],[70.0104167,49.0833333]],[[73.34375,46.8333333],[73.34375,49.0833333]],[[76.6770833,46.8333333],[76.6770833,49.0833333]],[[80.0104167,46.8333333],[80.0104167,49.0833333]],[[83.34375,46.8333333],[83.34375,49.0833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-103.4583333,49.0833333],[-96.1666667,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-93.3229167,49.0833333],[-93.3229167,58.5833333]],[[-89.9895833,49.0833333],[-89.9895833,58.5833333]],[[-86.65625,49.0833333],[-86.65625,58.5833333]],[[-83.3229167,49.0833333],[-83.3229167,58.5833333]],[[-79.9895833,49.0833333],[-79.9895833,58.5833333]],[[-76.65625,49.0833333],[-76.65625,58.5833333]],[[-73.3229167,49.0833333],[-73.3229167,58.5833333]],[[-69.9895833,49.0833333],[-69.9895833,58.5833333]],[[-66.65625,49.0833333],[-66.65625,58.5833333]],[[-63.3229167,49.0833333],[-63.3229167,58.5833333]],[[-59.9895833,49.0833333],[-59.9895833,58.5833333]],[[-56.65625,49.0833333],[-56.65625,58.5833333]],[[-53.3229167,49.0833333],[-53.3229167,58.5833333]],[[-49.9895833,49.0833333],[-49.9895833,58.5833333]],[[-46.65625,49.0833333],[-46.65625,58.5833333]],[[-43.3229167,49.0833333],[-43.3229167,58.5833333]],[[-39.9895833,49.0833333],[-39.9895833,58.5833333]],[[-36.65625,49.0833333],[-36.65625,58.5833333]],[[-33.3229167,49.0833333],[-33.3229167,58.5833333]],[[-29.9895833,49.0833333],[-29.9895833,58.5833333]],[[-26.65625,49.0833333],[-26.65625,58.5833333]],[[-23.3229167,49.0833333],[-23.3229167,58.5833333]],[[-19.9895833,49.0833333],[-19.9895833,58.5833333]],[[-16.65625,49.0833333],[-16.65625,58.5833333]],[[-13.3229167,49.0833333],[-13.3229167,58.5833333]],[[-9.9895833,49.0833333],[-9.9895833,58.5833333]],[[-6.65625,49.0833333],[-6.65625,58.5833333]],[[-3.3229167,49.0833333],[-3.3229167,58.5833333]],[[0.0104167,49.0833333],[0.0104167,58.5833333]],[[3.34375,49.0833333],[3.34375,58.5833333]],[[6.6770833,49.0833333],[6.6770833,58.5833333]],[[10.0104167,49.0833333],[10.0104167,58.5833333]],[[13.34375,49.0833333],[13.34375,58.5833333]],[[16.6770833,49.0833333],[16.6770833,58.5833333]],[[20.0104167,49.0833333],[20.0104167,58.5833333]],[[23.34375,49.0833333],[23.34375,58.5833333]],[[26.6770833,49.0833333],[26.6770833,58.5833333]],[[30.0104167,49.0833333],[30.0104167,58.5833333]],[[33.34375,49.0833333],[33.34375,58.5833333]],[[36.6770833,49.0833333],[36.6770833,58.5833333]],[[40.0104167,49.0833333],[40.0104167,58.5833333]],[[43.34375,49.0833333],[43.34375,58.5833333]],[[46.6770833,49.0833333],[46.6770833,58.5833333]],[[50.0104167,49.0833333],[50.0104167,58.5833333]],[[53.34375,49.0833333],[53.34375,58.5833333]],[[56.6770833,49.0833333],[56.6770833,58.5833333]],[[60.0104167,49.0833333],[60.0104167,58.5833333]],[[63.34375,49.0833333],[63.34375,58.5833333]],[[66.6770833,49.0833333],[66.6770833,58.5833333]],[[70.0104167,49.0833333],[70.0104167,58.5833333]],[[73.34375,49.0833333],[73.34375,58.5833333]],[[76.6770833,49.0833333],[76.6770833,58.5833333]],[[80.0104167,49.0833333],[80.0104167,58.5833333]],[[83.34375,49.0833333],[83.34375,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[86.6770833,46.8333333],[86.6770833,49.0833333]],[[90.0104167,46.8333333],[90.0104167,49.0833333]],[[93.34375,46.8333333],[93.34375,49.0833333]],[[86.6770833,49.0833333],[86.6770833,58.5833333]],[[90.0104167,49.0833333],[90.0104167,58.5833333]],[[93.34375,49.0833333],[93.34375,58.5833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]]],"sourceHandles":["1F39B","1F39C","1F39D","1F39E","1F39F","1F3A0","1F3A1","1F3A2","1F3A3","1F3A4","1F3A5","1F3A6","1F3A7","1F3A8","1F3A9","1F3AA","1F3AB","1F3AC","1F3AD","1F3AE","1F3AF","1F3B0","1F3B1","1F3B2","1F3B3","1F3B4","1F3B5","1F3B6","1F3B7","1F3B8","1F3B9","1F3BA","1F3BB","1F3BC","1F3BD","1F3BE","1F3BF","1F3C0","1F3C1","1F3C2","1F3C3","1F3C4","1F3C5","1F3C6","1F3C7","1F3C8","1F3C9","1F3CA","1F3CB","1F3CC","1F3CD","1F3CE","1F3CF","1F3D0","1F3D1","1F3D2","1F3D3","1F3D4","1F3D5","1F3D6","1F3D7","1F3D8","1F3D9","1F3DA","1F3DB","1F3DC","1F3DD","1F3DE","1F3DF","1F3E0","1F3E1","1F3E2","1F3E3","1F3E4","1F3E5","1F3E6","1F3E7","1F3E8","1F3E9","1F3EA","1F3EB","1F3EC","1F3ED","1F3EE","1F3EF","1F3F0","1F3F1","1F3F2","1F3F3","1F3F4","1F3F5","1F3F6","1F3F7","1F3F8","1F3F9","1F3FA","1F3FB","1F3FC","1F3FD","1F3FE","1F3FF","1F400","1F401","1F402","1F403","1F404","1F405","1F406","1F407","1F408","1F409","1F40A","1F40B","1F40C","1F40D","1F40E","1F40F","1F410","1F411","1F412","1F413","1F414","1F415"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC2 roof-cap reference reused from WTC1; exact WTC2 geometry unverified","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]},{"id":"upper-exterior-1-west-roof-cap-reference","tower":1,"face":"west","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[-104.4166667,49.0833333],[104.4166667,49.0833333]],[[-96.1666667,58.5833333],[96.1666667,58.5833333]],[[-93.3229167,46.8333333],[-93.3229167,49.0833333]],[[-89.9895833,46.8333333],[-89.9895833,49.0833333]],[[-86.65625,46.8333333],[-86.65625,49.0833333]],[[-83.3229167,46.8333333],[-83.3229167,49.0833333]],[[-79.9895833,46.8333333],[-79.9895833,49.0833333]],[[-76.65625,46.8333333],[-76.65625,49.0833333]],[[-73.3229167,46.8333333],[-73.3229167,49.0833333]],[[-69.9895833,46.8333333],[-69.9895833,49.0833333]],[[-66.65625,46.8333333],[-66.65625,49.0833333]],[[-63.3229167,46.8333333],[-63.3229167,49.0833333]],[[-59.9895833,46.8333333],[-59.9895833,49.0833333]],[[-56.65625,46.8333333],[-56.65625,49.0833333]],[[-53.3229167,46.8333333],[-53.3229167,49.0833333]],[[-49.9895833,46.8333333],[-49.9895833,49.0833333]],[[-46.65625,46.8333333],[-46.65625,49.0833333]],[[-43.3229167,46.8333333],[-43.3229167,49.0833333]],[[-39.9895833,46.8333333],[-39.9895833,49.0833333]],[[-36.65625,46.8333333],[-36.65625,49.0833333]],[[-33.3229167,46.8333333],[-33.3229167,49.0833333]],[[-29.9895833,46.8333333],[-29.9895833,49.0833333]],[[-26.65625,46.8333333],[-26.65625,49.0833333]],[[-23.3229167,46.8333333],[-23.3229167,49.0833333]],[[-19.9895833,46.8333333],[-19.9895833,49.0833333]],[[-16.65625,46.8333333],[-16.65625,49.0833333]],[[-13.3229167,46.8333333],[-13.3229167,49.0833333]],[[-9.9895833,46.8333333],[-9.9895833,49.0833333]],[[-6.65625,46.8333333],[-6.65625,49.0833333]],[[-3.3229167,46.8333333],[-3.3229167,49.0833333]],[[0.0104167,46.8333333],[0.0104167,49.0833333]],[[3.34375,46.8333333],[3.34375,49.0833333]],[[6.6770833,46.8333333],[6.6770833,49.0833333]],[[10.0104167,46.8333333],[10.0104167,49.0833333]],[[13.34375,46.8333333],[13.34375,49.0833333]],[[16.6770833,46.8333333],[16.6770833,49.0833333]],[[20.0104167,46.8333333],[20.0104167,49.0833333]],[[23.34375,46.8333333],[23.34375,49.0833333]],[[26.6770833,46.8333333],[26.6770833,49.0833333]],[[30.0104167,46.8333333],[30.0104167,49.0833333]],[[33.34375,46.8333333],[33.34375,49.0833333]],[[36.6770833,46.8333333],[36.6770833,49.0833333]],[[40.0104167,46.8333333],[40.0104167,49.0833333]],[[43.34375,46.8333333],[43.34375,49.0833333]],[[46.6770833,46.8333333],[46.6770833,49.0833333]],[[50.0104167,46.8333333],[50.0104167,49.0833333]],[[53.34375,46.8333333],[53.34375,49.0833333]],[[56.6770833,46.8333333],[56.6770833,49.0833333]],[[60.0104167,46.8333333],[60.0104167,49.0833333]],[[63.34375,46.8333333],[63.34375,49.0833333]],[[66.6770833,46.8333333],[66.6770833,49.0833333]],[[70.0104167,46.8333333],[70.0104167,49.0833333]],[[73.34375,46.8333333],[73.34375,49.0833333]],[[76.6770833,46.8333333],[76.6770833,49.0833333]],[[80.0104167,46.8333333],[80.0104167,49.0833333]],[[83.34375,46.8333333],[83.34375,49.0833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-103.4583333,49.0833333],[-96.1666667,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-93.3229167,49.0833333],[-93.3229167,58.5833333]],[[-89.9895833,49.0833333],[-89.9895833,58.5833333]],[[-86.65625,49.0833333],[-86.65625,58.5833333]],[[-83.3229167,49.0833333],[-83.3229167,58.5833333]],[[-79.9895833,49.0833333],[-79.9895833,58.5833333]],[[-76.65625,49.0833333],[-76.65625,58.5833333]],[[-73.3229167,49.0833333],[-73.3229167,58.5833333]],[[-69.9895833,49.0833333],[-69.9895833,58.5833333]],[[-66.65625,49.0833333],[-66.65625,58.5833333]],[[-63.3229167,49.0833333],[-63.3229167,58.5833333]],[[-59.9895833,49.0833333],[-59.9895833,58.5833333]],[[-56.65625,49.0833333],[-56.65625,58.5833333]],[[-53.3229167,49.0833333],[-53.3229167,58.5833333]],[[-49.9895833,49.0833333],[-49.9895833,58.5833333]],[[-46.65625,49.0833333],[-46.65625,58.5833333]],[[-43.3229167,49.0833333],[-43.3229167,58.5833333]],[[-39.9895833,49.0833333],[-39.9895833,58.5833333]],[[-36.65625,49.0833333],[-36.65625,58.5833333]],[[-33.3229167,49.0833333],[-33.3229167,58.5833333]],[[-29.9895833,49.0833333],[-29.9895833,58.5833333]],[[-26.65625,49.0833333],[-26.65625,58.5833333]],[[-23.3229167,49.0833333],[-23.3229167,58.5833333]],[[-19.9895833,49.0833333],[-19.9895833,58.5833333]],[[-16.65625,49.0833333],[-16.65625,58.5833333]],[[-13.3229167,49.0833333],[-13.3229167,58.5833333]],[[-9.9895833,49.0833333],[-9.9895833,58.5833333]],[[-6.65625,49.0833333],[-6.65625,58.5833333]],[[-3.3229167,49.0833333],[-3.3229167,58.5833333]],[[0.0104167,49.0833333],[0.0104167,58.5833333]],[[3.34375,49.0833333],[3.34375,58.5833333]],[[6.6770833,49.0833333],[6.6770833,58.5833333]],[[10.0104167,49.0833333],[10.0104167,58.5833333]],[[13.34375,49.0833333],[13.34375,58.5833333]],[[16.6770833,49.0833333],[16.6770833,58.5833333]],[[20.0104167,49.0833333],[20.0104167,58.5833333]],[[23.34375,49.0833333],[23.34375,58.5833333]],[[26.6770833,49.0833333],[26.6770833,58.5833333]],[[30.0104167,49.0833333],[30.0104167,58.5833333]],[[33.34375,49.0833333],[33.34375,58.5833333]],[[36.6770833,49.0833333],[36.6770833,58.5833333]],[[40.0104167,49.0833333],[40.0104167,58.5833333]],[[43.34375,49.0833333],[43.34375,58.5833333]],[[46.6770833,49.0833333],[46.6770833,58.5833333]],[[50.0104167,49.0833333],[50.0104167,58.5833333]],[[53.34375,49.0833333],[53.34375,58.5833333]],[[56.6770833,49.0833333],[56.6770833,58.5833333]],[[60.0104167,49.0833333],[60.0104167,58.5833333]],[[63.34375,49.0833333],[63.34375,58.5833333]],[[66.6770833,49.0833333],[66.6770833,58.5833333]],[[70.0104167,49.0833333],[70.0104167,58.5833333]],[[73.34375,49.0833333],[73.34375,58.5833333]],[[76.6770833,49.0833333],[76.6770833,58.5833333]],[[80.0104167,49.0833333],[80.0104167,58.5833333]],[[83.34375,49.0833333],[83.34375,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[86.6770833,46.8333333],[86.6770833,49.0833333]],[[90.0104167,46.8333333],[90.0104167,49.0833333]],[[93.34375,46.8333333],[93.34375,49.0833333]],[[86.6770833,49.0833333],[86.6770833,58.5833333]],[[90.0104167,49.0833333],[90.0104167,58.5833333]],[[93.34375,49.0833333],[93.34375,58.5833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]]],"sourceHandles":["1597A","1597B","1597C","1597D","1597E","1597F","15980","15981","15982","15983","15984","15985","15986","15987","15988","15989","1598A","1598B","1598C","1598D","1598E","1598F","15990","15991","15992","15993","15994","15995","15996","15997","15998","15999","1599A","1599B","1599C","1599D","1599E","1599F","159A0","159A1","159A2","159A3","159A4","159A5","159A6","159A7","159A8","159A9","159AA","159AB","159AC","159AD","159AE","159AF","159B0","159B1","159B2","159B3","159B4","159B5","159B6","159B7","159B8","159B9","159BA","159BB","159BC","159BD","159BE","159BF","159C0","159C1","159C2","159C3","159C4","159C5","159C6","159C7","159C8","159C9","159CA","159CB","159CC","159CD","159CE","159CF","159D0","159D1","159D2","159D3","159D4","159D5","159D6","159D7","159D8","159D9","159DA","159DB","159DC","159DD","159DE","159DF","159E0","159E1","159E2","159E3","159E4","159E5","159E6","159E7","159E8","159E9","159EA","159EB","159EC","159ED","159EE","159EF","159F0","159F1","159F2","159F3","159F4"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC1 CAD roof-cap elevation reference","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]},{"id":"upper-exterior-2-west-roof-cap-reference","tower":2,"face":"west","kind":"roof-cap-reference","floor":110,"segmentsFt":[[[-104.4166667,49.0833333],[104.4166667,49.0833333]],[[-96.1666667,58.5833333],[96.1666667,58.5833333]],[[-93.3229167,46.8333333],[-93.3229167,49.0833333]],[[-89.9895833,46.8333333],[-89.9895833,49.0833333]],[[-86.65625,46.8333333],[-86.65625,49.0833333]],[[-83.3229167,46.8333333],[-83.3229167,49.0833333]],[[-79.9895833,46.8333333],[-79.9895833,49.0833333]],[[-76.65625,46.8333333],[-76.65625,49.0833333]],[[-73.3229167,46.8333333],[-73.3229167,49.0833333]],[[-69.9895833,46.8333333],[-69.9895833,49.0833333]],[[-66.65625,46.8333333],[-66.65625,49.0833333]],[[-63.3229167,46.8333333],[-63.3229167,49.0833333]],[[-59.9895833,46.8333333],[-59.9895833,49.0833333]],[[-56.65625,46.8333333],[-56.65625,49.0833333]],[[-53.3229167,46.8333333],[-53.3229167,49.0833333]],[[-49.9895833,46.8333333],[-49.9895833,49.0833333]],[[-46.65625,46.8333333],[-46.65625,49.0833333]],[[-43.3229167,46.8333333],[-43.3229167,49.0833333]],[[-39.9895833,46.8333333],[-39.9895833,49.0833333]],[[-36.65625,46.8333333],[-36.65625,49.0833333]],[[-33.3229167,46.8333333],[-33.3229167,49.0833333]],[[-29.9895833,46.8333333],[-29.9895833,49.0833333]],[[-26.65625,46.8333333],[-26.65625,49.0833333]],[[-23.3229167,46.8333333],[-23.3229167,49.0833333]],[[-19.9895833,46.8333333],[-19.9895833,49.0833333]],[[-16.65625,46.8333333],[-16.65625,49.0833333]],[[-13.3229167,46.8333333],[-13.3229167,49.0833333]],[[-9.9895833,46.8333333],[-9.9895833,49.0833333]],[[-6.65625,46.8333333],[-6.65625,49.0833333]],[[-3.3229167,46.8333333],[-3.3229167,49.0833333]],[[0.0104167,46.8333333],[0.0104167,49.0833333]],[[3.34375,46.8333333],[3.34375,49.0833333]],[[6.6770833,46.8333333],[6.6770833,49.0833333]],[[10.0104167,46.8333333],[10.0104167,49.0833333]],[[13.34375,46.8333333],[13.34375,49.0833333]],[[16.6770833,46.8333333],[16.6770833,49.0833333]],[[20.0104167,46.8333333],[20.0104167,49.0833333]],[[23.34375,46.8333333],[23.34375,49.0833333]],[[26.6770833,46.8333333],[26.6770833,49.0833333]],[[30.0104167,46.8333333],[30.0104167,49.0833333]],[[33.34375,46.8333333],[33.34375,49.0833333]],[[36.6770833,46.8333333],[36.6770833,49.0833333]],[[40.0104167,46.8333333],[40.0104167,49.0833333]],[[43.34375,46.8333333],[43.34375,49.0833333]],[[46.6770833,46.8333333],[46.6770833,49.0833333]],[[50.0104167,46.8333333],[50.0104167,49.0833333]],[[53.34375,46.8333333],[53.34375,49.0833333]],[[56.6770833,46.8333333],[56.6770833,49.0833333]],[[60.0104167,46.8333333],[60.0104167,49.0833333]],[[63.34375,46.8333333],[63.34375,49.0833333]],[[66.6770833,46.8333333],[66.6770833,49.0833333]],[[70.0104167,46.8333333],[70.0104167,49.0833333]],[[73.34375,46.8333333],[73.34375,49.0833333]],[[76.6770833,46.8333333],[76.6770833,49.0833333]],[[80.0104167,46.8333333],[80.0104167,49.0833333]],[[83.34375,46.8333333],[83.34375,49.0833333]],[[-96.1666667,49.0833333],[-96.1666667,58.5833333]],[[-96.1666667,58.5833333],[-103.4583333,49.0833333]],[[-103.4583333,49.0833333],[-96.1666667,49.0833333]],[[-99.8125,49.0833333],[-96.1666667,58.5833333]],[[-93.3229167,49.0833333],[-93.3229167,58.5833333]],[[-89.9895833,49.0833333],[-89.9895833,58.5833333]],[[-86.65625,49.0833333],[-86.65625,58.5833333]],[[-83.3229167,49.0833333],[-83.3229167,58.5833333]],[[-79.9895833,49.0833333],[-79.9895833,58.5833333]],[[-76.65625,49.0833333],[-76.65625,58.5833333]],[[-73.3229167,49.0833333],[-73.3229167,58.5833333]],[[-69.9895833,49.0833333],[-69.9895833,58.5833333]],[[-66.65625,49.0833333],[-66.65625,58.5833333]],[[-63.3229167,49.0833333],[-63.3229167,58.5833333]],[[-59.9895833,49.0833333],[-59.9895833,58.5833333]],[[-56.65625,49.0833333],[-56.65625,58.5833333]],[[-53.3229167,49.0833333],[-53.3229167,58.5833333]],[[-49.9895833,49.0833333],[-49.9895833,58.5833333]],[[-46.65625,49.0833333],[-46.65625,58.5833333]],[[-43.3229167,49.0833333],[-43.3229167,58.5833333]],[[-39.9895833,49.0833333],[-39.9895833,58.5833333]],[[-36.65625,49.0833333],[-36.65625,58.5833333]],[[-33.3229167,49.0833333],[-33.3229167,58.5833333]],[[-29.9895833,49.0833333],[-29.9895833,58.5833333]],[[-26.65625,49.0833333],[-26.65625,58.5833333]],[[-23.3229167,49.0833333],[-23.3229167,58.5833333]],[[-19.9895833,49.0833333],[-19.9895833,58.5833333]],[[-16.65625,49.0833333],[-16.65625,58.5833333]],[[-13.3229167,49.0833333],[-13.3229167,58.5833333]],[[-9.9895833,49.0833333],[-9.9895833,58.5833333]],[[-6.65625,49.0833333],[-6.65625,58.5833333]],[[-3.3229167,49.0833333],[-3.3229167,58.5833333]],[[0.0104167,49.0833333],[0.0104167,58.5833333]],[[3.34375,49.0833333],[3.34375,58.5833333]],[[6.6770833,49.0833333],[6.6770833,58.5833333]],[[10.0104167,49.0833333],[10.0104167,58.5833333]],[[13.34375,49.0833333],[13.34375,58.5833333]],[[16.6770833,49.0833333],[16.6770833,58.5833333]],[[20.0104167,49.0833333],[20.0104167,58.5833333]],[[23.34375,49.0833333],[23.34375,58.5833333]],[[26.6770833,49.0833333],[26.6770833,58.5833333]],[[30.0104167,49.0833333],[30.0104167,58.5833333]],[[33.34375,49.0833333],[33.34375,58.5833333]],[[36.6770833,49.0833333],[36.6770833,58.5833333]],[[40.0104167,49.0833333],[40.0104167,58.5833333]],[[43.34375,49.0833333],[43.34375,58.5833333]],[[46.6770833,49.0833333],[46.6770833,58.5833333]],[[50.0104167,49.0833333],[50.0104167,58.5833333]],[[53.34375,49.0833333],[53.34375,58.5833333]],[[56.6770833,49.0833333],[56.6770833,58.5833333]],[[60.0104167,49.0833333],[60.0104167,58.5833333]],[[63.34375,49.0833333],[63.34375,58.5833333]],[[66.6770833,49.0833333],[66.6770833,58.5833333]],[[70.0104167,49.0833333],[70.0104167,58.5833333]],[[73.34375,49.0833333],[73.34375,58.5833333]],[[76.6770833,49.0833333],[76.6770833,58.5833333]],[[80.0104167,49.0833333],[80.0104167,58.5833333]],[[83.34375,49.0833333],[83.34375,58.5833333]],[[96.1666667,58.5833333],[103.4583333,49.0833333]],[[99.8125,49.0833333],[96.1666667,58.5833333]],[[86.6770833,46.8333333],[86.6770833,49.0833333]],[[90.0104167,46.8333333],[90.0104167,49.0833333]],[[93.34375,46.8333333],[93.34375,49.0833333]],[[86.6770833,49.0833333],[86.6770833,58.5833333]],[[90.0104167,49.0833333],[90.0104167,58.5833333]],[[93.34375,49.0833333],[93.34375,58.5833333]],[[96.1666667,49.0833333],[96.1666667,58.5833333]]],"sourceHandles":["1597A","1597B","1597C","1597D","1597E","1597F","15980","15981","15982","15983","15984","15985","15986","15987","15988","15989","1598A","1598B","1598C","1598D","1598E","1598F","15990","15991","15992","15993","15994","15995","15996","15997","15998","15999","1599A","1599B","1599C","1599D","1599E","1599F","159A0","159A1","159A2","159A3","159A4","159A5","159A6","159A7","159A8","159A9","159AA","159AB","159AC","159AD","159AE","159AF","159B0","159B1","159B2","159B3","159B4","159B5","159B6","159B7","159B8","159B9","159BA","159BB","159BC","159BD","159BE","159BF","159C0","159C1","159C2","159C3","159C4","159C5","159C6","159C7","159C8","159C9","159CA","159CB","159CC","159CD","159CE","159CF","159D0","159D1","159D2","159D3","159D4","159D5","159D6","159D7","159D8","159D9","159DA","159DB","159DC","159DD","159DE","159DF","159E0","159E1","159E2","159E3","159E4","159E5","159E6","159E7","159E8","159E9","159EA","159EB","159EC","159ED","159EE","159EF","159F0","159F1","159F2","159F3","159F4"],"source":{"id":"lza_wtc1_cad","file":"sources/LERA - PLANS-022102/Dxf's/wtc1_2000.dxf","layer":"S-Spandrels"},"scope":"WTC2 roof-cap reference reused from WTC1; exact WTC2 geometry unverified","limitations":["Line-only source reference. Structural steel, cladding, parapet and coping identity not resolved; no thickness asserted.","CAD top is 58ft7in above Floor107, one inch above the supplied roof-panel schedule reference.","Outer corner lines are elevation projections, not reconstructed three-dimensional corner closures."]}]}