{"schemaVersion":1,"building":"Original 7 World Trade Center (1987\u20132001)","scope":"Original E122 four-face belt bracing at Floors22\u201324 and12 explicitly labeled moment-frame W36 chords. Other chords remain in the floor-framing reconstruction.","units":"feet","coordinateSystem":{"x":"east","y":"up","z":"south","groundDrawingDatumFt":311.3333333333333,"plan":"node.columnId resolves from dimensioned wtc7_blueprint_grid.json; E122 perimeter dimension chains agree with these positions"},"nodes":[{"id":"belt:north:1:22:workpoint","columnId":"1","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:57:23:workpoint","columnId":"57","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:56:22:workpoint","columnId":"56","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:55:23:workpoint","columnId":"55","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:54:22:workpoint","columnId":"54","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:53:23:workpoint","columnId":"53","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:52:22:workpoint","columnId":"52","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:51:23:workpoint","columnId":"51","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:50:22:workpoint","columnId":"50","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:49:23:workpoint","columnId":"49","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:48:22:workpoint","columnId":"48","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:47:23:workpoint","columnId":"47","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:46:22:workpoint","columnId":"46","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:45:23:workpoint","columnId":"45","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:44:22:workpoint","columnId":"44","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:43:23:workpoint","columnId":"43","face":"north","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:42:22:workpoint","columnId":"42","face":"north","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:1:24:workpoint","columnId":"1","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:56:24:workpoint","columnId":"56","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:54:24:workpoint","columnId":"54","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:52:24:workpoint","columnId":"52","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:50:24:workpoint","columnId":"50","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:48:24:workpoint","columnId":"48","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:46:24:workpoint","columnId":"46","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:44:24:workpoint","columnId":"44","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:42:24:workpoint","columnId":"42","face":"north","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:15:22:workpoint","columnId":"15","face":"south","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:16:23:workpoint","columnId":"16","face":"south","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:17:22:workpoint","columnId":"17","face":"south","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:18:23:workpoint","columnId":"18","face":"south","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:19:22:workpoint","columnId":"19","face":"south","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:20:23:workpoint","columnId":"20","face":"south","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:21:22:workpoint","columnId":"21","face":"south","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:22:23:workpoint","columnId":"22","face":"south","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:23:22:workpoint","columnId":"23","face":"south","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:24:23:workpoint","columnId":"24","face":"south","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:25:22:workpoint","columnId":"25","face":"south","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:26:23:workpoint","columnId":"26","face":"south","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:27:22:workpoint","columnId":"27","face":"south","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:28:23:workpoint","columnId":"28","face":"south","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:15:24:workpoint","columnId":"15","face":"south","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:17:24:workpoint","columnId":"17","face":"south","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:19:24:workpoint","columnId":"19","face":"south","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:21:24:workpoint","columnId":"21","face":"south","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:23:24:workpoint","columnId":"23","face":"south","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:25:24:workpoint","columnId":"25","face":"south","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:27:24:workpoint","columnId":"27","face":"south","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:1:22:workpoint","columnId":"1","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:2:23:workpoint","columnId":"2","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:3:22:workpoint","columnId":"3","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:4:23:workpoint","columnId":"4","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:5:22:workpoint","columnId":"5","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:6:23:workpoint","columnId":"6","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:7:22:workpoint","columnId":"7","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:8:23:workpoint","columnId":"8","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:9:22:workpoint","columnId":"9","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:10:23:workpoint","columnId":"10","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:11:22:workpoint","columnId":"11","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:12:23:workpoint","columnId":"12","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:13:22:workpoint","columnId":"13","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:14:23:workpoint","columnId":"14","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:14A:22:workpoint","columnId":"14A","face":"west","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:15:23:workpoint","columnId":"15","face":"west","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:1:24:workpoint","columnId":"1","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:3:24:workpoint","columnId":"3","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:5:24:workpoint","columnId":"5","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:7:24:workpoint","columnId":"7","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:9:24:workpoint","columnId":"9","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:11:24:workpoint","columnId":"11","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:13:24:workpoint","columnId":"13","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:14A:24:workpoint","columnId":"14A","face":"west","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:28:22:workpoint","columnId":"28","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:29:23:workpoint","columnId":"29","face":"east","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:30:22:workpoint","columnId":"30","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:31:23:workpoint","columnId":"31","face":"east","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:32:22:workpoint","columnId":"32","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:33:23:workpoint","columnId":"33","face":"east","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:34:22:workpoint","columnId":"34","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:35:23:workpoint","columnId":"35","face":"east","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:36:22:workpoint","columnId":"36","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:37:23:workpoint","columnId":"37","face":"east","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:38:22:workpoint","columnId":"38","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:39:23:workpoint","columnId":"39","face":"east","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:40:22:workpoint","columnId":"40","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:41:23:workpoint","columnId":"41","face":"east","level":"23","floor":23,"datumElevationFt":595.875,"yFt":284.541666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:42:22:workpoint","columnId":"42","face":"east","level":"22","floor":22,"datumElevationFt":581.125,"yFt":269.791666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:28:24:workpoint","columnId":"28","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:30:24:workpoint","columnId":"30","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:32:24:workpoint","columnId":"32","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:34:24:workpoint","columnId":"34","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:36:24:workpoint","columnId":"36","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:38:24:workpoint","columnId":"38","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:40:24:workpoint","columnId":"40","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:42:24:workpoint","columnId":"42","face":"east","level":"24","floor":24,"datumElevationFt":610.625,"yFt":299.291666667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E122 explicit workpoint13.5in below finished-floor line","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:57:22:moment-chord","columnId":"57","face":"north","level":"22","floor":22,"datumElevationFt":580.270833333,"yFt":268.9375,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:56:22:moment-chord","columnId":"56","face":"north","level":"22","floor":22,"datumElevationFt":580.270833333,"yFt":268.9375,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:57:23:moment-chord","columnId":"57","face":"north","level":"23","floor":23,"datumElevationFt":595.0375,"yFt":283.704166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:56:23:moment-chord","columnId":"56","face":"north","level":"23","floor":23,"datumElevationFt":595.0375,"yFt":283.704166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:north:57:24:moment-chord","columnId":"57","face":"north","level":"24","floor":24,"datumElevationFt":609.7875,"yFt":298.454166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:north:56:24:moment-chord","columnId":"56","face":"north","level":"24","floor":24,"datumElevationFt":609.7875,"yFt":298.454166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:18:22:moment-chord","columnId":"18","face":"south","level":"22","floor":22,"datumElevationFt":580.2625,"yFt":268.929166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:19:22:moment-chord","columnId":"19","face":"south","level":"22","floor":22,"datumElevationFt":580.2625,"yFt":268.929166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:18:23:moment-chord","columnId":"18","face":"south","level":"23","floor":23,"datumElevationFt":595.020833333,"yFt":283.6875,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:19:23:moment-chord","columnId":"19","face":"south","level":"23","floor":23,"datumElevationFt":595.020833333,"yFt":283.6875,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:south:18:24:moment-chord","columnId":"18","face":"south","level":"24","floor":24,"datumElevationFt":609.770833333,"yFt":298.4375,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:south:19:24:moment-chord","columnId":"19","face":"south","level":"24","floor":24,"datumElevationFt":609.770833333,"yFt":298.4375,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:1:22:moment-chord","columnId":"1","face":"west","level":"22","floor":22,"datumElevationFt":580.2875,"yFt":268.954166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:2:22:moment-chord","columnId":"2","face":"west","level":"22","floor":22,"datumElevationFt":580.2875,"yFt":268.954166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:1:23:moment-chord","columnId":"1","face":"west","level":"23","floor":23,"datumElevationFt":595.0125,"yFt":283.679166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:2:23:moment-chord","columnId":"2","face":"west","level":"23","floor":23,"datumElevationFt":595.0125,"yFt":283.679166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:west:1:24:moment-chord","columnId":"1","face":"west","level":"24","floor":24,"datumElevationFt":609.7625,"yFt":298.429166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:west:2:24:moment-chord","columnId":"2","face":"west","level":"24","floor":24,"datumElevationFt":609.7625,"yFt":298.429166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:28:22:moment-chord","columnId":"28","face":"east","level":"22","floor":22,"datumElevationFt":580.2875,"yFt":268.954166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:29:22:moment-chord","columnId":"29","face":"east","level":"22","floor":22,"datumElevationFt":580.2875,"yFt":268.954166667,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:28:23:moment-chord","columnId":"28","face":"east","level":"23","floor":23,"datumElevationFt":595.020833333,"yFt":283.6875,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:29:23:moment-chord","columnId":"29","face":"east","level":"23","floor":23,"datumElevationFt":595.020833333,"yFt":283.6875,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E22_23"]},{"id":"belt:east:28:24:moment-chord","columnId":"28","face":"east","level":"24","floor":24,"datumElevationFt":609.770833333,"yFt":298.4375,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]},{"id":"belt:east:29:24:moment-chord","columnId":"29","face":"east","level":"24","floor":24,"datumElevationFt":609.770833333,"yFt":298.4375,"positionStatus":"dimensioned-upper-grid;E122-bay-chain-cross-check","verticalBasis":"E1225.5in top-of-steel offset below finished floor, minus published W36 section half-depth","verticalUncertaintyFt":0,"sourceIds":["frankel-E122","frankel-E24"]}],"members":[{"id":"belt-north-brace-22-01","face":"north","kind":"brace","startNode":"belt:north:1:22:workpoint","endNode":"belt:north:57:23:workpoint","fromColumn":"1","toColumn":"57","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"A2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay1\u201357; Floors22\u201323; A2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-22-02","face":"north","kind":"brace","startNode":"belt:north:57:23:workpoint","endNode":"belt:north:56:22:workpoint","fromColumn":"57","toColumn":"56","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay57\u201356; Floors22\u201323; C2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-22-03","face":"north","kind":"brace","startNode":"belt:north:56:22:workpoint","endNode":"belt:north:55:23:workpoint","fromColumn":"56","toColumn":"55","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"D2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay56\u201355; Floors22\u201323; D2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-22-04","face":"north","kind":"brace","startNode":"belt:north:55:23:workpoint","endNode":"belt:north:54:22:workpoint","fromColumn":"55","toColumn":"54","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"S2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay55\u201354; Floors22\u201323; S2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-05","face":"north","kind":"brace","startNode":"belt:north:54:22:workpoint","endNode":"belt:north:53:23:workpoint","fromColumn":"54","toColumn":"53","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay54\u201353; Floors22\u201323; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-06","face":"north","kind":"brace","startNode":"belt:north:53:23:workpoint","endNode":"belt:north:52:22:workpoint","fromColumn":"53","toColumn":"52","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay53\u201352; Floors22\u201323; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-07","face":"north","kind":"brace","startNode":"belt:north:52:22:workpoint","endNode":"belt:north:51:23:workpoint","fromColumn":"52","toColumn":"51","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay52\u201351; Floors22\u201323; M2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-08","face":"north","kind":"brace","startNode":"belt:north:51:23:workpoint","endNode":"belt:north:50:22:workpoint","fromColumn":"51","toColumn":"50","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay51\u201350; Floors22\u201323; M2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-09","face":"north","kind":"brace","startNode":"belt:north:50:22:workpoint","endNode":"belt:north:49:23:workpoint","fromColumn":"50","toColumn":"49","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay50\u201349; Floors22\u201323; M2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-10","face":"north","kind":"brace","startNode":"belt:north:49:23:workpoint","endNode":"belt:north:48:22:workpoint","fromColumn":"49","toColumn":"48","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay49\u201348; Floors22\u201323; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-11","face":"north","kind":"brace","startNode":"belt:north:48:22:workpoint","endNode":"belt:north:47:23:workpoint","fromColumn":"48","toColumn":"47","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay48\u201347; Floors22\u201323; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-12","face":"north","kind":"brace","startNode":"belt:north:47:23:workpoint","endNode":"belt:north:46:22:workpoint","fromColumn":"47","toColumn":"46","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"P2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay47\u201346; Floors22\u201323; P2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-22-13","face":"north","kind":"brace","startNode":"belt:north:46:22:workpoint","endNode":"belt:north:45:23:workpoint","fromColumn":"46","toColumn":"45","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay46\u201345; Floors22\u201323; G2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-22-14","face":"north","kind":"brace","startNode":"belt:north:45:23:workpoint","endNode":"belt:north:44:22:workpoint","fromColumn":"45","toColumn":"44","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay45\u201344; Floors22\u201323; G2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-22-15","face":"north","kind":"brace","startNode":"belt:north:44:22:workpoint","endNode":"belt:north:43:23:workpoint","fromColumn":"44","toColumn":"43","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay44\u201343; Floors22\u201323; H2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-22-16","face":"north","kind":"brace","startNode":"belt:north:43:23:workpoint","endNode":"belt:north:42:22:workpoint","fromColumn":"43","toColumn":"42","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"B2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay43\u201342; Floors22\u201323; B2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-23-01","face":"north","kind":"brace","startNode":"belt:north:1:24:workpoint","endNode":"belt:north:57:23:workpoint","fromColumn":"1","toColumn":"57","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"A2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay1\u201357; Floors23\u201324; A2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-23-02","face":"north","kind":"brace","startNode":"belt:north:57:23:workpoint","endNode":"belt:north:56:24:workpoint","fromColumn":"57","toColumn":"56","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay57\u201356; Floors23\u201324; C2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-23-03","face":"north","kind":"brace","startNode":"belt:north:56:24:workpoint","endNode":"belt:north:55:23:workpoint","fromColumn":"56","toColumn":"55","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"D2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay56\u201355; Floors23\u201324; D2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-23-04","face":"north","kind":"brace","startNode":"belt:north:55:23:workpoint","endNode":"belt:north:54:24:workpoint","fromColumn":"55","toColumn":"54","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"S2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay55\u201354; Floors23\u201324; S2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-05","face":"north","kind":"brace","startNode":"belt:north:54:24:workpoint","endNode":"belt:north:53:23:workpoint","fromColumn":"54","toColumn":"53","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay54\u201353; Floors23\u201324; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-06","face":"north","kind":"brace","startNode":"belt:north:53:23:workpoint","endNode":"belt:north:52:24:workpoint","fromColumn":"53","toColumn":"52","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay53\u201352; Floors23\u201324; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-07","face":"north","kind":"brace","startNode":"belt:north:52:24:workpoint","endNode":"belt:north:51:23:workpoint","fromColumn":"52","toColumn":"51","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay52\u201351; Floors23\u201324; M2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-08","face":"north","kind":"brace","startNode":"belt:north:51:23:workpoint","endNode":"belt:north:50:24:workpoint","fromColumn":"51","toColumn":"50","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay51\u201350; Floors23\u201324; M2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-09","face":"north","kind":"brace","startNode":"belt:north:50:24:workpoint","endNode":"belt:north:49:23:workpoint","fromColumn":"50","toColumn":"49","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay50\u201349; Floors23\u201324; M2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-10","face":"north","kind":"brace","startNode":"belt:north:49:23:workpoint","endNode":"belt:north:48:24:workpoint","fromColumn":"49","toColumn":"48","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay49\u201348; Floors23\u201324; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-11","face":"north","kind":"brace","startNode":"belt:north:48:24:workpoint","endNode":"belt:north:47:23:workpoint","fromColumn":"48","toColumn":"47","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay48\u201347; Floors23\u201324; K2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-12","face":"north","kind":"brace","startNode":"belt:north:47:23:workpoint","endNode":"belt:north:46:24:workpoint","fromColumn":"47","toColumn":"46","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"P2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay47\u201346; Floors23\u201324; P2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-north-brace-23-13","face":"north","kind":"brace","startNode":"belt:north:46:24:workpoint","endNode":"belt:north:45:23:workpoint","fromColumn":"46","toColumn":"45","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay46\u201345; Floors23\u201324; G2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-23-14","face":"north","kind":"brace","startNode":"belt:north:45:23:workpoint","endNode":"belt:north:44:24:workpoint","fromColumn":"45","toColumn":"44","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay45\u201344; Floors23\u201324; G2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-23-15","face":"north","kind":"brace","startNode":"belt:north:44:24:workpoint","endNode":"belt:north:43:23:workpoint","fromColumn":"44","toColumn":"43","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay44\u201343; Floors23\u201324; H2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-brace-23-16","face":"north","kind":"brace","startNode":"belt:north:43:23:workpoint","endNode":"belt:north:42:24:workpoint","fromColumn":"43","toColumn":"42","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"B2287Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 north elevation; bay43\u201342; Floors23\u201324; B2287Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-north-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-22-01","face":"south","kind":"brace","startNode":"belt:south:15:22:workpoint","endNode":"belt:south:16:23:workpoint","fromColumn":"15","toColumn":"16","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"A2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay15\u201316; Floors22\u201323; A2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-22-02","face":"south","kind":"brace","startNode":"belt:south:16:23:workpoint","endNode":"belt:south:17:22:workpoint","fromColumn":"16","toColumn":"17","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay16\u201317; Floors22\u201323; M2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-03","face":"south","kind":"brace","startNode":"belt:south:17:22:workpoint","endNode":"belt:south:18:23:workpoint","fromColumn":"17","toColumn":"18","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay17\u201318; Floors22\u201323; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-04","face":"south","kind":"brace","startNode":"belt:south:18:23:workpoint","endNode":"belt:south:19:22:workpoint","fromColumn":"18","toColumn":"19","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay18\u201319; Floors22\u201323; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-05","face":"south","kind":"brace","startNode":"belt:south:19:22:workpoint","endNode":"belt:south:20:23:workpoint","fromColumn":"19","toColumn":"20","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay19\u201320; Floors22\u201323; H2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-06","face":"south","kind":"brace","startNode":"belt:south:20:23:workpoint","endNode":"belt:south:21:22:workpoint","fromColumn":"20","toColumn":"21","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay20\u201321; Floors22\u201323; K2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-07","face":"south","kind":"brace","startNode":"belt:south:21:22:workpoint","endNode":"belt:south:22:23:workpoint","fromColumn":"21","toColumn":"22","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay21\u201322; Floors22\u201323; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-08","face":"south","kind":"brace","startNode":"belt:south:22:23:workpoint","endNode":"belt:south:23:22:workpoint","fromColumn":"22","toColumn":"23","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay22\u201323; Floors22\u201323; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-09","face":"south","kind":"brace","startNode":"belt:south:23:22:workpoint","endNode":"belt:south:24:23:workpoint","fromColumn":"23","toColumn":"24","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay23\u201324; Floors22\u201323; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-22-10","face":"south","kind":"brace","startNode":"belt:south:24:23:workpoint","endNode":"belt:south:25:22:workpoint","fromColumn":"24","toColumn":"25","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"D2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay24\u201325; Floors22\u201323; D2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-22-11","face":"south","kind":"brace","startNode":"belt:south:25:22:workpoint","endNode":"belt:south:26:23:workpoint","fromColumn":"25","toColumn":"26","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay25\u201326; Floors22\u201323; C2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-22-12","face":"south","kind":"brace","startNode":"belt:south:26:23:workpoint","endNode":"belt:south:27:22:workpoint","fromColumn":"26","toColumn":"27","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay26\u201327; Floors22\u201323; C2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-22-13","face":"south","kind":"brace","startNode":"belt:south:27:22:workpoint","endNode":"belt:south:28:23:workpoint","fromColumn":"27","toColumn":"28","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"B2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay27\u201328; Floors22\u201323; B2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-23-01","face":"south","kind":"brace","startNode":"belt:south:15:24:workpoint","endNode":"belt:south:16:23:workpoint","fromColumn":"15","toColumn":"16","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"A2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay15\u201316; Floors23\u201324; A2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-23-02","face":"south","kind":"brace","startNode":"belt:south:16:23:workpoint","endNode":"belt:south:17:24:workpoint","fromColumn":"16","toColumn":"17","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay16\u201317; Floors23\u201324; M2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-03","face":"south","kind":"brace","startNode":"belt:south:17:24:workpoint","endNode":"belt:south:18:23:workpoint","fromColumn":"17","toColumn":"18","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay17\u201318; Floors23\u201324; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-04","face":"south","kind":"brace","startNode":"belt:south:18:23:workpoint","endNode":"belt:south:19:24:workpoint","fromColumn":"18","toColumn":"19","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay18\u201319; Floors23\u201324; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-05","face":"south","kind":"brace","startNode":"belt:south:19:24:workpoint","endNode":"belt:south:20:23:workpoint","fromColumn":"19","toColumn":"20","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay19\u201320; Floors23\u201324; H2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-06","face":"south","kind":"brace","startNode":"belt:south:20:23:workpoint","endNode":"belt:south:21:24:workpoint","fromColumn":"20","toColumn":"21","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay20\u201321; Floors23\u201324; K2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-07","face":"south","kind":"brace","startNode":"belt:south:21:24:workpoint","endNode":"belt:south:22:23:workpoint","fromColumn":"21","toColumn":"22","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay21\u201322; Floors23\u201324; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-08","face":"south","kind":"brace","startNode":"belt:south:22:23:workpoint","endNode":"belt:south:23:24:workpoint","fromColumn":"22","toColumn":"23","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay22\u201323; Floors23\u201324; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-09","face":"south","kind":"brace","startNode":"belt:south:23:24:workpoint","endNode":"belt:south:24:23:workpoint","fromColumn":"23","toColumn":"24","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 MC10x33.6","family":"paired-channel","count":2,"componentDesignation":"MC10x33.6","componentFamily":"channel","nominalDepthIn":10,"weightEachLbPerFt":33.6,"weightLbPerFt":67.2,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay23\u201324; Floors23\u201324; G2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 WT4x33.5","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-south-brace-23-10","face":"south","kind":"brace","startNode":"belt:south:24:23:workpoint","endNode":"belt:south:25:24:workpoint","fromColumn":"24","toColumn":"25","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"D2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay24\u201325; Floors23\u201324; D2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-23-11","face":"south","kind":"brace","startNode":"belt:south:25:24:workpoint","endNode":"belt:south:26:23:workpoint","fromColumn":"25","toColumn":"26","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay25\u201326; Floors23\u201324; C2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-23-12","face":"south","kind":"brace","startNode":"belt:south:26:23:workpoint","endNode":"belt:south:27:24:workpoint","fromColumn":"26","toColumn":"27","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay26\u201327; Floors23\u201324; C2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-south-brace-23-13","face":"south","kind":"brace","startNode":"belt:south:27:24:workpoint","endNode":"belt:south:28:23:workpoint","fromColumn":"27","toColumn":"28","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 WT5x56","family":"paired-tee","count":2,"componentDesignation":"WT5x56","componentFamily":"structural-tee","nominalDepthIn":5,"weightEachLbPerFt":56,"weightLbPerFt":112,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"P2286Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 south elevation; bay27\u201328; Floors23\u201324; P2286Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-south-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-22-01","face":"west","kind":"brace","startNode":"belt:west:1:22:workpoint","endNode":"belt:west:2:23:workpoint","fromColumn":"1","toColumn":"2","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"A2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay1\u20132; Floors22\u201323; A2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-22-02","face":"west","kind":"brace","startNode":"belt:west:2:23:workpoint","endNode":"belt:west:3:22:workpoint","fromColumn":"2","toColumn":"3","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"B2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay2\u20133; Floors22\u201323; B2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-22-03","face":"west","kind":"brace","startNode":"belt:west:3:22:workpoint","endNode":"belt:west:4:23:workpoint","fromColumn":"3","toColumn":"4","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay3\u20134; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-04","face":"west","kind":"brace","startNode":"belt:west:4:23:workpoint","endNode":"belt:west:5:22:workpoint","fromColumn":"4","toColumn":"5","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay4\u20135; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-05","face":"west","kind":"brace","startNode":"belt:west:5:22:workpoint","endNode":"belt:west:6:23:workpoint","fromColumn":"5","toColumn":"6","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay5\u20136; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-06","face":"west","kind":"brace","startNode":"belt:west:6:23:workpoint","endNode":"belt:west:7:22:workpoint","fromColumn":"6","toColumn":"7","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay6\u20137; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-07","face":"west","kind":"brace","startNode":"belt:west:7:22:workpoint","endNode":"belt:west:8:23:workpoint","fromColumn":"7","toColumn":"8","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay7\u20138; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-08","face":"west","kind":"brace","startNode":"belt:west:8:23:workpoint","endNode":"belt:west:9:22:workpoint","fromColumn":"8","toColumn":"9","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay8\u20139; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-09","face":"west","kind":"brace","startNode":"belt:west:9:22:workpoint","endNode":"belt:west:10:23:workpoint","fromColumn":"9","toColumn":"10","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay9\u201310; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-10","face":"west","kind":"brace","startNode":"belt:west:10:23:workpoint","endNode":"belt:west:11:22:workpoint","fromColumn":"10","toColumn":"11","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay10\u201311; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-11","face":"west","kind":"brace","startNode":"belt:west:11:22:workpoint","endNode":"belt:west:12:23:workpoint","fromColumn":"11","toColumn":"12","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay11\u201312; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-12","face":"west","kind":"brace","startNode":"belt:west:12:23:workpoint","endNode":"belt:west:13:22:workpoint","fromColumn":"12","toColumn":"13","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay12\u201313; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-22-13","face":"west","kind":"brace","startNode":"belt:west:13:22:workpoint","endNode":"belt:west:14:23:workpoint","fromColumn":"13","toColumn":"14","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay13\u201314; Floors22\u201323; C2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-22-14","face":"west","kind":"brace","startNode":"belt:west:14:23:workpoint","endNode":"belt:west:14A:22:workpoint","fromColumn":"14","toColumn":"14A","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay14\u201314A; Floors22\u201323; C2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-22-15","face":"west","kind":"brace","startNode":"belt:west:14A:22:workpoint","endNode":"belt:west:15:23:workpoint","fromColumn":"14A","toColumn":"15","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"D2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay14A\u201315; Floors22\u201323; D2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-23-01","face":"west","kind":"brace","startNode":"belt:west:1:24:workpoint","endNode":"belt:west:2:23:workpoint","fromColumn":"1","toColumn":"2","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"A2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay1\u20132; Floors23\u201324; A2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-23-02","face":"west","kind":"brace","startNode":"belt:west:2:23:workpoint","endNode":"belt:west:3:24:workpoint","fromColumn":"2","toColumn":"3","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"B2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay2\u20133; Floors23\u201324; B2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-23-03","face":"west","kind":"brace","startNode":"belt:west:3:24:workpoint","endNode":"belt:west:4:23:workpoint","fromColumn":"3","toColumn":"4","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay3\u20134; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-04","face":"west","kind":"brace","startNode":"belt:west:4:23:workpoint","endNode":"belt:west:5:24:workpoint","fromColumn":"4","toColumn":"5","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay4\u20135; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-05","face":"west","kind":"brace","startNode":"belt:west:5:24:workpoint","endNode":"belt:west:6:23:workpoint","fromColumn":"5","toColumn":"6","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay5\u20136; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-06","face":"west","kind":"brace","startNode":"belt:west:6:23:workpoint","endNode":"belt:west:7:24:workpoint","fromColumn":"6","toColumn":"7","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay6\u20137; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-07","face":"west","kind":"brace","startNode":"belt:west:7:24:workpoint","endNode":"belt:west:8:23:workpoint","fromColumn":"7","toColumn":"8","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay7\u20138; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-08","face":"west","kind":"brace","startNode":"belt:west:8:23:workpoint","endNode":"belt:west:9:24:workpoint","fromColumn":"8","toColumn":"9","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay8\u20139; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-09","face":"west","kind":"brace","startNode":"belt:west:9:24:workpoint","endNode":"belt:west:10:23:workpoint","fromColumn":"9","toColumn":"10","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay9\u201310; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-10","face":"west","kind":"brace","startNode":"belt:west:10:23:workpoint","endNode":"belt:west:11:24:workpoint","fromColumn":"10","toColumn":"11","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay10\u201311; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-11","face":"west","kind":"brace","startNode":"belt:west:11:24:workpoint","endNode":"belt:west:12:23:workpoint","fromColumn":"11","toColumn":"12","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay11\u201312; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-12","face":"west","kind":"brace","startNode":"belt:west:12:23:workpoint","endNode":"belt:west:13:24:workpoint","fromColumn":"12","toColumn":"13","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay12\u201313; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-west-brace-23-13","face":"west","kind":"brace","startNode":"belt:west:13:24:workpoint","endNode":"belt:west:14:23:workpoint","fromColumn":"13","toColumn":"14","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay13\u201314; Floors23\u201324; C2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-23-14","face":"west","kind":"brace","startNode":"belt:west:14:23:workpoint","endNode":"belt:west:14A:24:workpoint","fromColumn":"14","toColumn":"14A","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"C2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay14\u201314A; Floors23\u201324; C2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-west-brace-23-15","face":"west","kind":"brace","startNode":"belt:west:14A:24:workpoint","endNode":"belt:west:15:23:workpoint","fromColumn":"14A","toColumn":"15","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"D2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 west elevation; bay14A\u201315; Floors23\u201324; D2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-west-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-22-01","face":"east","kind":"brace","startNode":"belt:east:28:22:workpoint","endNode":"belt:east:29:23:workpoint","fromColumn":"28","toColumn":"29","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay28\u201329; Floors22\u201323; G2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-22-02","face":"east","kind":"brace","startNode":"belt:east:29:23:workpoint","endNode":"belt:east:30:22:workpoint","fromColumn":"29","toColumn":"30","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay29\u201330; Floors22\u201323; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-22-03","face":"east","kind":"brace","startNode":"belt:east:30:22:workpoint","endNode":"belt:east:31:23:workpoint","fromColumn":"30","toColumn":"31","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay30\u201331; Floors22\u201323; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-22-04","face":"east","kind":"brace","startNode":"belt:east:31:23:workpoint","endNode":"belt:east:32:22:workpoint","fromColumn":"31","toColumn":"32","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay31\u201332; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-05","face":"east","kind":"brace","startNode":"belt:east:32:22:workpoint","endNode":"belt:east:33:23:workpoint","fromColumn":"32","toColumn":"33","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay32\u201333; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-06","face":"east","kind":"brace","startNode":"belt:east:33:23:workpoint","endNode":"belt:east:34:22:workpoint","fromColumn":"33","toColumn":"34","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay33\u201334; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-07","face":"east","kind":"brace","startNode":"belt:east:34:22:workpoint","endNode":"belt:east:35:23:workpoint","fromColumn":"34","toColumn":"35","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay34\u201335; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-08","face":"east","kind":"brace","startNode":"belt:east:35:23:workpoint","endNode":"belt:east:36:22:workpoint","fromColumn":"35","toColumn":"36","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay35\u201336; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-09","face":"east","kind":"brace","startNode":"belt:east:36:22:workpoint","endNode":"belt:east:37:23:workpoint","fromColumn":"36","toColumn":"37","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay36\u201337; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-10","face":"east","kind":"brace","startNode":"belt:east:37:23:workpoint","endNode":"belt:east:38:22:workpoint","fromColumn":"37","toColumn":"38","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay37\u201338; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-11","face":"east","kind":"brace","startNode":"belt:east:38:22:workpoint","endNode":"belt:east:39:23:workpoint","fromColumn":"38","toColumn":"39","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay38\u201339; Floors22\u201323; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-22-12","face":"east","kind":"brace","startNode":"belt:east:39:23:workpoint","endNode":"belt:east:40:22:workpoint","fromColumn":"39","toColumn":"40","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay39\u201340; Floors22\u201323; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-22-13","face":"east","kind":"brace","startNode":"belt:east:40:22:workpoint","endNode":"belt:east:41:23:workpoint","fromColumn":"40","toColumn":"41","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay40\u201341; Floors22\u201323; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-22-14","face":"east","kind":"brace","startNode":"belt:east:41:23:workpoint","endNode":"belt:east:42:22:workpoint","fromColumn":"41","toColumn":"42","lowerFloor":22,"upperFloor":23,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay41\u201342; Floors22\u201323; K2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-23-01","face":"east","kind":"brace","startNode":"belt:east:28:24:workpoint","endNode":"belt:east:29:23:workpoint","fromColumn":"28","toColumn":"29","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"G2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay28\u201329; Floors23\u201324; G2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-23-02","face":"east","kind":"brace","startNode":"belt:east:29:23:workpoint","endNode":"belt:east:30:24:workpoint","fromColumn":"29","toColumn":"30","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay29\u201330; Floors23\u201324; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-23-03","face":"east","kind":"brace","startNode":"belt:east:30:24:workpoint","endNode":"belt:east:31:23:workpoint","fromColumn":"30","toColumn":"31","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay30\u201331; Floors23\u201324; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-23-04","face":"east","kind":"brace","startNode":"belt:east:31:23:workpoint","endNode":"belt:east:32:24:workpoint","fromColumn":"31","toColumn":"32","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay31\u201332; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-05","face":"east","kind":"brace","startNode":"belt:east:32:24:workpoint","endNode":"belt:east:33:23:workpoint","fromColumn":"32","toColumn":"33","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay32\u201333; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-06","face":"east","kind":"brace","startNode":"belt:east:33:23:workpoint","endNode":"belt:east:34:24:workpoint","fromColumn":"33","toColumn":"34","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay33\u201334; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-07","face":"east","kind":"brace","startNode":"belt:east:34:24:workpoint","endNode":"belt:east:35:23:workpoint","fromColumn":"34","toColumn":"35","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay34\u201335; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-08","face":"east","kind":"brace","startNode":"belt:east:35:23:workpoint","endNode":"belt:east:36:24:workpoint","fromColumn":"35","toColumn":"36","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay35\u201336; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-09","face":"east","kind":"brace","startNode":"belt:east:36:24:workpoint","endNode":"belt:east:37:23:workpoint","fromColumn":"36","toColumn":"37","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay36\u201337; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-10","face":"east","kind":"brace","startNode":"belt:east:37:23:workpoint","endNode":"belt:east:38:24:workpoint","fromColumn":"37","toColumn":"38","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay37\u201338; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-11","face":"east","kind":"brace","startNode":"belt:east:38:24:workpoint","endNode":"belt:east:39:23:workpoint","fromColumn":"38","toColumn":"39","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x50","family":"paired-channel","count":2,"componentDesignation":"C15x50","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":50,"weightLbPerFt":100,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"M2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay38\u201339; Floors23\u201324; M2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"},"designSection":{"designation":"2 C15x40","status":"superseded by E122 substitutions-to-suit-stock note; do not render as erected"}},{"id":"belt-east-brace-23-12","face":"east","kind":"brace","startNode":"belt:east:39:23:workpoint","endNode":"belt:east:40:24:workpoint","fromColumn":"39","toColumn":"40","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay39\u201340; Floors23\u201324; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-23-13","face":"east","kind":"brace","startNode":"belt:east:40:24:workpoint","endNode":"belt:east:41:23:workpoint","fromColumn":"40","toColumn":"41","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"H2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay40\u201341; Floors23\u201324; H2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-east-brace-23-14","face":"east","kind":"brace","startNode":"belt:east:41:23:workpoint","endNode":"belt:east:42:24:workpoint","fromColumn":"41","toColumn":"42","lowerFloor":23,"upperFloor":24,"section":{"designation":"2 C15x33.9","family":"paired-channel","count":2,"componentDesignation":"C15x33.9","componentFamily":"channel","nominalDepthIn":15,"weightEachLbPerFt":33.9,"weightLbPerFt":67.8,"status":"E122-readable-erection-designation","pairGapIn":null,"pairArrangementStatus":"pair separation and roll not transcribed from connection/shop details"},"erectionMark":"K2301Y","sourceIds":["frankel-E122"],"sourceRegion":"E122 east elevation; bay41\u201342; Floors23\u201324; K2301Y","sourceCrops":["analysis/wtc7-blueprint-reconstruction/belt-source-crops/E122-east-full.png"],"geometryBasis":"original elevation brace workpoints, explicit floor offsets and dimensioned perimeter column centers","profileStatus":"paired section family and weight transcribed; component catalog geometry and pair assembly status must be exposed","note":"Workpoint-to-workpoint structural line, not cut length. Gussets, end setbacks, bolts, welds, stitch plates, pair gap and member roll are not established by this elevation transcription.","material":{"specification":"ASTM A36","sourceId":"frankel-E122"}},{"id":"belt-north-moment-chord-22","face":"north","kind":"beam","floor":22,"startNode":"belt:north:57:22:moment-chord","endNode":"belt:north:56:22:moment-chord","fromColumn":"57","toColumn":"56","topOfSteelDatumFt":581.791666667,"section":{"designation":"W36x280","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":280,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 north moment-frame bay57\u201356, Floor22","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted.","erectionMark":"B2273"},{"id":"belt-north-moment-chord-23","face":"north","kind":"beam","floor":23,"startNode":"belt:north:57:23:moment-chord","endNode":"belt:north:56:23:moment-chord","fromColumn":"57","toColumn":"56","topOfSteelDatumFt":596.541666667,"section":{"designation":"W36x245","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":245,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 north moment-frame bay57\u201356, Floor23","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted.","erectionMark":"B2269"},{"id":"belt-north-moment-chord-24","face":"north","kind":"beam","floor":24,"startNode":"belt:north:57:24:moment-chord","endNode":"belt:north:56:24:moment-chord","fromColumn":"57","toColumn":"56","topOfSteelDatumFt":611.291666667,"section":{"designation":"W36x245","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":245,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E24"],"sourceRegion":"E122 north moment-frame bay57\u201356, Floor24","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted.","erectionMark":"A2344"},{"id":"belt-south-moment-chord-22","face":"south","kind":"beam","floor":22,"startNode":"belt:south:18:22:moment-chord","endNode":"belt:south:19:22:moment-chord","fromColumn":"18","toColumn":"19","topOfSteelDatumFt":581.791666667,"section":{"designation":"W36x210","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":210,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 south moment-frame bay18\u201319, Floor22","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted.","erectionMark":"B2261"},{"id":"belt-south-moment-chord-23","face":"south","kind":"beam","floor":23,"startNode":"belt:south:18:23:moment-chord","endNode":"belt:south:19:23:moment-chord","fromColumn":"18","toColumn":"19","topOfSteelDatumFt":596.541666667,"section":{"designation":"W36x194","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":194,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 south moment-frame bay18\u201319, Floor23","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted.","erectionMark":"B2294"},{"id":"belt-south-moment-chord-24","face":"south","kind":"beam","floor":24,"startNode":"belt:south:18:24:moment-chord","endNode":"belt:south:19:24:moment-chord","fromColumn":"18","toColumn":"19","topOfSteelDatumFt":611.291666667,"section":{"designation":"W36x194","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":194,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E24"],"sourceRegion":"E122 south moment-frame bay18\u201319, Floor24","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted.","erectionMark":"A2347"},{"id":"belt-west-moment-chord-22","face":"west","kind":"beam","floor":22,"startNode":"belt:west:1:22:moment-chord","endNode":"belt:west:2:22:moment-chord","fromColumn":"1","toColumn":"2","topOfSteelDatumFt":581.791666667,"section":{"designation":"W36x245","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":245,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 west moment-frame bay1\u20132, Floor22","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted."},{"id":"belt-west-moment-chord-23","face":"west","kind":"beam","floor":23,"startNode":"belt:west:1:23:moment-chord","endNode":"belt:west:2:23:moment-chord","fromColumn":"1","toColumn":"2","topOfSteelDatumFt":596.541666667,"section":{"designation":"W36x210","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":210,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 west moment-frame bay1\u20132, Floor23","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted."},{"id":"belt-west-moment-chord-24","face":"west","kind":"beam","floor":24,"startNode":"belt:west:1:24:moment-chord","endNode":"belt:west:2:24:moment-chord","fromColumn":"1","toColumn":"2","topOfSteelDatumFt":611.291666667,"section":{"designation":"W36x210","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":210,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E24"],"sourceRegion":"E122 west moment-frame bay1\u20132, Floor24","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted."},{"id":"belt-east-moment-chord-22","face":"east","kind":"beam","floor":22,"startNode":"belt:east:28:22:moment-chord","endNode":"belt:east:29:22:moment-chord","fromColumn":"28","toColumn":"29","topOfSteelDatumFt":581.791666667,"section":{"designation":"W36x245","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":245,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 east moment-frame bay28\u201329, Floor22","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted."},{"id":"belt-east-moment-chord-23","face":"east","kind":"beam","floor":23,"startNode":"belt:east:28:23:moment-chord","endNode":"belt:east:29:23:moment-chord","fromColumn":"28","toColumn":"29","topOfSteelDatumFt":596.541666667,"section":{"designation":"W36x194","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":194,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E22_23"],"sourceRegion":"E122 east moment-frame bay28\u201329, Floor23","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted."},{"id":"belt-east-moment-chord-24","face":"east","kind":"beam","floor":24,"startNode":"belt:east:28:24:moment-chord","endNode":"belt:east:29:24:moment-chord","fromColumn":"28","toColumn":"29","topOfSteelDatumFt":611.291666667,"section":{"designation":"W36x194","family":"wide-flange","nominalDepthIn":36,"weightLbPerFt":194,"status":"E122-readable-erection-designation"},"sourceIds":["frankel-E122","frankel-E24"],"sourceRegion":"E122 east moment-frame bay28\u201329, Floor24","geometryBasis":"E122 explicit moment-beam designation; floor-plan general top-of-steel datum; published section depth","profileStatus":"published section catalog; original connection and mill tolerances unresolved","note":"Explicitly labeled W36 moment chord. Brace workpoint is inside its web and has its own datum. End connections and shop setbacks are omitted."}],"sources":[{"id":"frankel-E122","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E122.tif","sheet":"E122","use":"All four elevation chains,116 diagonal assignments, substitutions, workpoint offsets and12 moment chord labels"},{"id":"frankel-E22_23","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E22_23.tif","use":"Finished-floor elevations and general steel offset for22/23"},{"id":"frankel-E24","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E24.tif","use":"Finished-floor elevation and general steel offset for24"}],"limitations":["Paired tees/channels must not be rendered as generic W sections.","Published component sections do not establish pair separation, orientation, stitch plates, gussets, bolts, end setbacks or welds. Those assembly properties remain provisional until shop/connection drawings are transcribed.","Brace lines join source workpoints, not cut ends or pin centers at individual connection plates.","Other horizontal belt chords have readable piece marks but their member sizes await E22/23/E24 or shop cross-reference; they are not duplicated with invented W36 sizes here.","Column sections belong to the perimeter column schedule and are not duplicated in this assembly."],"counts":{"nodes":118,"members":128,"byKind":{"brace":116,"beam":12},"braceSections":{"2 WT5x56":24,"2 MC10x33.6":34,"2 C15x33.9":22,"2 C15x50":36}}}