{"schemaVersion":1,"building":"WTC 7","scope":"Shop-bill-length-verified core-column web and side reinforcement and C55 perimeter web plates above Floor 7; one member represents a pair of physical plates.","units":"feet for model y; inches for section and shop finished lengths","coordinateSystem":"wtc7_blueprint_grid model x/z through columnId; wtc7_floor_datums model yFt","category":"reinforcement","sourceFile":"wtc7_column_reinforcement","nodes":[{"id":"CORE-C70-F7-F9-reinforcement-0-a","columnId":"70","yFt":81.166667},{"id":"CORE-C70-F7-F9-reinforcement-0-b","columnId":"70","yFt":106.666667},{"id":"CORE-C70-F9-F11-reinforcement-0-a","columnId":"70","yFt":106.666667},{"id":"CORE-C70-F9-F11-reinforcement-0-b","columnId":"70","yFt":132.166667},{"id":"CORE-C73-F7-F9-reinforcement-0-a","columnId":"73","yFt":81.166667},{"id":"CORE-C73-F7-F9-reinforcement-0-b","columnId":"73","yFt":106.666667},{"id":"CORE-C73-F9-F11-reinforcement-0-a","columnId":"73","yFt":106.666667},{"id":"CORE-C73-F9-F11-reinforcement-0-b","columnId":"73","yFt":132.166667},{"id":"CORE-C73-F11-F13-reinforcement-0-a","columnId":"73","yFt":132.166667},{"id":"CORE-C73-F11-F13-reinforcement-0-b","columnId":"73","yFt":157.666667},{"id":"CORE-C73-F13-F15-reinforcement-0-a","columnId":"73","yFt":157.666667},{"id":"CORE-C73-F13-F15-reinforcement-0-b","columnId":"73","yFt":183.166667},{"id":"CORE-C73-F15-F17-reinforcement-0-a","columnId":"73","yFt":183.166667},{"id":"CORE-C73-F15-F17-reinforcement-0-b","columnId":"73","yFt":208.666667},{"id":"CORE-C73-F17-F19-reinforcement-0-a","columnId":"73","yFt":208.666667},{"id":"CORE-C73-F17-F19-reinforcement-0-b","columnId":"73","yFt":234.166667},{"id":"CORE-C73-F19-F21-reinforcement-0-a","columnId":"73","yFt":234.166667},{"id":"CORE-C73-F19-F21-reinforcement-0-b","columnId":"73","yFt":259.666667},{"id":"CORE-TRANSFER-START-C76-reinforcement-0-a","columnId":"76","yFt":77.208334},{"id":"CORE-TRANSFER-START-C76-reinforcement-0-b","columnId":"76","yFt":106.666667},{"id":"CORE-C76-F9-F11-reinforcement-0-a","columnId":"76","yFt":106.666667},{"id":"CORE-C76-F9-F11-reinforcement-0-b","columnId":"76","yFt":132.166667},{"id":"CORE-C76-F11-F13-reinforcement-0-a","columnId":"76","yFt":132.166667},{"id":"CORE-C76-F11-F13-reinforcement-0-b","columnId":"76","yFt":157.666667},{"id":"CORE-C76-F13-F15-reinforcement-0-a","columnId":"76","yFt":157.666667},{"id":"CORE-C76-F13-F15-reinforcement-0-b","columnId":"76","yFt":183.166667},{"id":"CORE-C76-F15-F17-reinforcement-0-a","columnId":"76","yFt":183.166667},{"id":"CORE-C76-F15-F17-reinforcement-0-b","columnId":"76","yFt":208.666667},{"id":"CORE-C76-F17-F19-reinforcement-0-a","columnId":"76","yFt":208.666667},{"id":"CORE-C76-F17-F19-reinforcement-0-b","columnId":"76","yFt":234.166667},{"id":"CORE-C76-F19-F21-reinforcement-0-a","columnId":"76","yFt":234.166667},{"id":"CORE-C76-F19-F21-reinforcement-0-b","columnId":"76","yFt":259.666667},{"id":"CORE-C80-F7-F9-reinforcement-0-a","columnId":"80","yFt":81.166667},{"id":"CORE-C80-F7-F9-reinforcement-0-b","columnId":"80","yFt":106.666667},{"id":"CORE-C80-F9-F11-reinforcement-0-a","columnId":"80","yFt":106.666667},{"id":"CORE-C80-F9-F11-reinforcement-0-b","columnId":"80","yFt":132.166667},{"id":"CORE-C80-F11-F13-reinforcement-0-a","columnId":"80","yFt":132.166667},{"id":"CORE-C80-F11-F13-reinforcement-0-b","columnId":"80","yFt":157.666667},{"id":"CORE-C80-F13-F15-reinforcement-0-a","columnId":"80","yFt":157.666667},{"id":"CORE-C80-F13-F15-reinforcement-0-b","columnId":"80","yFt":183.166667},{"id":"CORE-C80-F15-F17-reinforcement-0-a","columnId":"80","yFt":183.166667},{"id":"CORE-C80-F15-F17-reinforcement-0-b","columnId":"80","yFt":208.666667},{"id":"CORE-C80-F17-F19-reinforcement-0-a","columnId":"80","yFt":208.666667},{"id":"CORE-C80-F17-F19-reinforcement-0-b","columnId":"80","yFt":234.166667},{"id":"CORE-C80-F19-F21-reinforcement-0-a","columnId":"80","yFt":234.166667},{"id":"CORE-C80-F19-F21-reinforcement-0-b","columnId":"80","yFt":259.666667},{"id":"CORE-C81-F7-F9-reinforcement-0-a","columnId":"81","yFt":81.166667},{"id":"CORE-C81-F7-F9-reinforcement-0-b","columnId":"81","yFt":106.666667},{"id":"CORE-C81-F9-F11-reinforcement-0-a","columnId":"81","yFt":106.666667},{"id":"CORE-C81-F9-F11-reinforcement-0-b","columnId":"81","yFt":132.166667},{"id":"CORE-C81-F11-F13-reinforcement-0-a","columnId":"81","yFt":132.166667},{"id":"CORE-C81-F11-F13-reinforcement-0-b","columnId":"81","yFt":157.666667},{"id":"CORE-C81-F13-F15-reinforcement-0-a","columnId":"81","yFt":157.666667},{"id":"CORE-C81-F13-F15-reinforcement-0-b","columnId":"81","yFt":183.166667},{"id":"CORE-C79-F7-F9-reinforcement-0-a","columnId":"79","yFt":81.166667},{"id":"CORE-C79-F7-F9-reinforcement-0-b","columnId":"79","yFt":106.666667},{"id":"CORE-C79-F9-F11-reinforcement-0-a","columnId":"79","yFt":106.666667},{"id":"CORE-C79-F9-F11-reinforcement-0-b","columnId":"79","yFt":132.166667},{"id":"CORE-C79-F11-F13-reinforcement-0-a","columnId":"79","yFt":132.166667},{"id":"CORE-C79-F11-F13-reinforcement-0-b","columnId":"79","yFt":157.666667},{"id":"CORE-C79-F13-F15-reinforcement-0-a","columnId":"79","yFt":157.666667},{"id":"CORE-C79-F13-F15-reinforcement-0-b","columnId":"79","yFt":183.166667},{"id":"CORE-C79-F15-F17-reinforcement-0-a","columnId":"79","yFt":183.166667},{"id":"CORE-C79-F15-F17-reinforcement-0-b","columnId":"79","yFt":208.666667},{"id":"CORE-C79-F17-F19-reinforcement-0-a","columnId":"79","yFt":208.666667},{"id":"CORE-C79-F17-F19-reinforcement-0-b","columnId":"79","yFt":234.166667},{"id":"CORE-C79-F19-F21-reinforcement-0-a","columnId":"79","yFt":234.166667},{"id":"CORE-C79-F19-F21-reinforcement-0-b","columnId":"79","yFt":259.666667},{"id":"CORE-C79-F21-F23-reinforcement-0-a","columnId":"79","yFt":259.666667},{"id":"CORE-C79-F21-F23-reinforcement-0-b","columnId":"79","yFt":289.166667},{"id":"PERIMETER-C55-F9-F11-reinforcement-0-a","columnId":"55","yFt":107.333334},{"id":"PERIMETER-C55-F9-F11-reinforcement-0-b","columnId":"55","yFt":132.166667}],"members":[{"id":"CORE-C70-F7-F9-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"70","startNode":"CORE-C70-F7-F9-reinforcement-0-a","endNode":"CORE-C70-F7-F9-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.035,"centerZ":0,"width":1,"depth":12.5},{"centerX":2.035,"centerZ":0,"width":1,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1078","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C70-F7-F9"],"sourceIds":["frankel-E117A","frankel-shop-1078"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1078.TIF"],"sourceRegion":"Grid 70, Floors 7-9, Frankel shop 1078 plate bill","longitudinalBounds":{"lowerYFt":81.166667,"upperYFt":106.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C70-F9-F11-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"70","startNode":"CORE-C70-F9-F11-reinforcement-0-a","endNode":"CORE-C70-F9-F11-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.035,"centerZ":0,"width":1,"depth":12.5},{"centerX":2.035,"centerZ":0,"width":1,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"B1078","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C70-F9-F11"],"sourceIds":["frankel-E117A","frankel-shop-1078"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1078.TIF"],"sourceRegion":"Grid 70, Floors 9-11, Frankel shop 1078 plate bill","longitudinalBounds":{"lowerYFt":106.666667,"upperYFt":132.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C73-F7-F9-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"73","startNode":"CORE-C73-F7-F9-reinforcement-0-a","endNode":"CORE-C73-F7-F9-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d76.5 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-4.785,"centerZ":0,"width":6.5,"depth":12.5},{"centerX":4.785,"centerZ":0,"width":6.5,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":6.5,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1040","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C73-F7-F9"],"sourceIds":["frankel-E117A","frankel-shop-1040"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1040.TIF"],"sourceRegion":"Grid 73, Floors 7-9, Frankel shop 1040 plate bill","longitudinalBounds":{"lowerYFt":81.166667,"upperYFt":106.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C73-F9-F11-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"73","startNode":"CORE-C73-F9-F11-reinforcement-0-a","endNode":"CORE-C73-F9-F11-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d76 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-4.535,"centerZ":0,"width":6,"depth":12.5},{"centerX":4.535,"centerZ":0,"width":6,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":6.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1041","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C73-F9-F11"],"sourceIds":["frankel-E117A","frankel-shop-1041"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1041.TIF"],"sourceRegion":"Grid 73, Floors 9-11, Frankel shop 1041 plate bill","longitudinalBounds":{"lowerYFt":106.666667,"upperYFt":132.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C73-F11-F13-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"73","startNode":"CORE-C73-F11-F13-reinforcement-0-a","endNode":"CORE-C73-F11-F13-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d75 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-4.035,"centerZ":0,"width":5,"depth":12.5},{"centerX":4.035,"centerZ":0,"width":5,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":5.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1042","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C73-F11-F13"],"sourceIds":["frankel-E117A","frankel-shop-1042"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1042.TIF"],"sourceRegion":"Grid 73, Floors 11-13, Frankel shop 1042 plate bill","longitudinalBounds":{"lowerYFt":132.166667,"upperYFt":157.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C73-F13-F15-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"73","startNode":"CORE-C73-F13-F15-reinforcement-0-a","endNode":"CORE-C73-F13-F15-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d74 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-3.535,"centerZ":0,"width":4,"depth":12.5},{"centerX":3.535,"centerZ":0,"width":4,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":4.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1043","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C73-F13-F15"],"sourceIds":["frankel-E117A","frankel-shop-1043"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1043.TIF"],"sourceRegion":"Grid 73, Floors 13-15, Frankel shop 1043 plate bill","longitudinalBounds":{"lowerYFt":157.666667,"upperYFt":183.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C73-F15-F17-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"73","startNode":"CORE-C73-F15-F17-reinforcement-0-a","endNode":"CORE-C73-F15-F17-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d73 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-3.035,"centerZ":0,"width":3,"depth":12.5},{"centerX":3.035,"centerZ":0,"width":3,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":3.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1121","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C73-F15-F17"],"sourceIds":["frankel-E117A","frankel-shop-1121"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1121.TIF"],"sourceRegion":"Grid 73, Floors 15-17, Frankel shop 1121 plate bill","longitudinalBounds":{"lowerYFt":183.166667,"upperYFt":208.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C73-F17-F19-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"73","startNode":"CORE-C73-F17-F19-reinforcement-0-a","endNode":"CORE-C73-F17-F19-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d72 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.535,"centerZ":0,"width":2,"depth":12.5},{"centerX":2.535,"centerZ":0,"width":2,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":2.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1122","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C73-F17-F19"],"sourceIds":["frankel-E117A","frankel-shop-1122"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1122.TIF"],"sourceRegion":"Grid 73, Floors 17-19, Frankel shop 1122 plate bill","longitudinalBounds":{"lowerYFt":208.666667,"upperYFt":234.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C73-F19-F21-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"73","startNode":"CORE-C73-F19-F21-reinforcement-0-a","endNode":"CORE-C73-F19-F21-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.035,"centerZ":0,"width":1,"depth":12.5},{"centerX":2.035,"centerZ":0,"width":1,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1137","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C73-F19-F21"],"sourceIds":["frankel-E117A","frankel-shop-1137"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1137.TIF"],"sourceRegion":"Grid 73, Floors 19-21, Frankel shop 1137 plate bill","longitudinalBounds":{"lowerYFt":234.166667,"upperYFt":259.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-TRANSFER-START-C76-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"76","startNode":"CORE-TRANSFER-START-C76-reinforcement-0-a","endNode":"CORE-TRANSFER-START-C76-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d78 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-5.535,"centerZ":0,"width":8,"depth":12.5},{"centerX":5.535,"centerZ":0,"width":8,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":8.0,"shopFinishedLengthIn":353.5,"shopPieceMark":"A1044","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C76-SHOPSTART-SPLICE7","COLUMN-CORE-C76-F7-F9"],"sourceIds":["frankel-E117A","frankel-shop-1044"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1044.TIF"],"sourceRegion":"Grid 76, Floors 7-9, Frankel shop 1044 plate bill","longitudinalBounds":{"lowerYFt":77.208334,"upperYFt":106.666667,"lengthFt":29.458333333333332,"status":"shop1044 milled both ends with column; E117A splice 9 upper datum"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C76-F9-F11-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"76","startNode":"CORE-C76-F9-F11-reinforcement-0-a","endNode":"CORE-C76-F9-F11-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d76 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-4.535,"centerZ":0,"width":6,"depth":12.5},{"centerX":4.535,"centerZ":0,"width":6,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":6.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1045","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C76-F9-F11"],"sourceIds":["frankel-E117A","frankel-shop-1045"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1045.TIF"],"sourceRegion":"Grid 76, Floors 9-11, Frankel shop 1045 plate bill","longitudinalBounds":{"lowerYFt":106.666667,"upperYFt":132.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C76-F11-F13-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"76","startNode":"CORE-C76-F11-F13-reinforcement-0-a","endNode":"CORE-C76-F11-F13-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d75 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-4.035,"centerZ":0,"width":5,"depth":12.5},{"centerX":4.035,"centerZ":0,"width":5,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":5.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1076","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C76-F11-F13"],"sourceIds":["frankel-E117A","frankel-shop-1076"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1076.TIF"],"sourceRegion":"Grid 76, Floors 11-13, Frankel shop 1076 plate bill","longitudinalBounds":{"lowerYFt":132.166667,"upperYFt":157.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C76-F13-F15-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"76","startNode":"CORE-C76-F13-F15-reinforcement-0-a","endNode":"CORE-C76-F13-F15-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d74 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-3.535,"centerZ":0,"width":4,"depth":12.5},{"centerX":3.535,"centerZ":0,"width":4,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":4.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1077","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C76-F13-F15"],"sourceIds":["frankel-E117A","frankel-shop-1077"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1077.TIF"],"sourceRegion":"Grid 76, Floors 13-15, Frankel shop 1077 plate bill","longitudinalBounds":{"lowerYFt":157.666667,"upperYFt":183.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C76-F15-F17-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"76","startNode":"CORE-C76-F15-F17-reinforcement-0-a","endNode":"CORE-C76-F15-F17-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d73 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-3.035,"centerZ":0,"width":3,"depth":12.5},{"centerX":3.035,"centerZ":0,"width":3,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":3.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1123","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C76-F15-F17"],"sourceIds":["frankel-E117A","frankel-shop-1123"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1123.TIF"],"sourceRegion":"Grid 76, Floors 15-17, Frankel shop 1123 plate bill","longitudinalBounds":{"lowerYFt":183.166667,"upperYFt":208.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C76-F17-F19-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"76","startNode":"CORE-C76-F17-F19-reinforcement-0-a","endNode":"CORE-C76-F17-F19-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d72 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.535,"centerZ":0,"width":2,"depth":12.5},{"centerX":2.535,"centerZ":0,"width":2,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":2.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1124","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C76-F17-F19"],"sourceIds":["frankel-E117A","frankel-shop-1124"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1124.TIF"],"sourceRegion":"Grid 76, Floors 17-19, Frankel shop 1124 plate bill","longitudinalBounds":{"lowerYFt":208.666667,"upperYFt":234.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C76-F19-F21-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"76","startNode":"CORE-C76-F19-F21-reinforcement-0-a","endNode":"CORE-C76-F19-F21-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.035,"centerZ":0,"width":1,"depth":12.5},{"centerX":2.035,"centerZ":0,"width":1,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1140","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C76-F19-F21"],"sourceIds":["frankel-E117A","frankel-shop-1140"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1140.TIF"],"sourceRegion":"Grid 76, Floors 19-21, Frankel shop 1140 plate bill","longitudinalBounds":{"lowerYFt":234.166667,"upperYFt":259.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C80-F7-F9-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"80","startNode":"CORE-C80-F7-F9-reinforcement-0-a","endNode":"CORE-C80-F7-F9-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d78 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-5.535,"centerZ":0,"width":8,"depth":12.5},{"centerX":5.535,"centerZ":0,"width":8,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":8.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1084","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C80-F7-F9"],"sourceIds":["frankel-E117A","frankel-shop-1084"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1084.TIF"],"sourceRegion":"Grid 80, Floors 7-9, Frankel shop 1084 plate bill","longitudinalBounds":{"lowerYFt":81.166667,"upperYFt":106.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C80-F9-F11-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"80","startNode":"CORE-C80-F9-F11-reinforcement-0-a","endNode":"CORE-C80-F9-F11-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d76 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-4.535,"centerZ":0,"width":6,"depth":12.5},{"centerX":4.535,"centerZ":0,"width":6,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":6.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1085","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C80-F9-F11"],"sourceIds":["frankel-E117A","frankel-shop-1085"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1085.TIF"],"sourceRegion":"Grid 80, Floors 9-11, Frankel shop 1085 plate bill","longitudinalBounds":{"lowerYFt":106.666667,"upperYFt":132.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C80-F11-F13-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"80","startNode":"CORE-C80-F11-F13-reinforcement-0-a","endNode":"CORE-C80-F11-F13-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d75 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-4.035,"centerZ":0,"width":5,"depth":12.5},{"centerX":4.035,"centerZ":0,"width":5,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":5.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1086","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C80-F11-F13"],"sourceIds":["frankel-E117A","frankel-shop-1086"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1086.TIF"],"sourceRegion":"Grid 80, Floors 11-13, Frankel shop 1086 plate bill","longitudinalBounds":{"lowerYFt":132.166667,"upperYFt":157.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C80-F13-F15-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"80","startNode":"CORE-C80-F13-F15-reinforcement-0-a","endNode":"CORE-C80-F13-F15-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d74 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-3.535,"centerZ":0,"width":4,"depth":12.5},{"centerX":3.535,"centerZ":0,"width":4,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":4.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1087","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C80-F13-F15"],"sourceIds":["frankel-E117A","frankel-shop-1087"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1087.TIF"],"sourceRegion":"Grid 80, Floors 13-15, Frankel shop 1087 plate bill","longitudinalBounds":{"lowerYFt":157.666667,"upperYFt":183.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C80-F15-F17-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"80","startNode":"CORE-C80-F15-F17-reinforcement-0-a","endNode":"CORE-C80-F15-F17-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d73 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-3.035,"centerZ":0,"width":3,"depth":12.5},{"centerX":3.035,"centerZ":0,"width":3,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":3.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1106","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C80-F15-F17"],"sourceIds":["frankel-E117A","frankel-shop-1106"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1106.TIF"],"sourceRegion":"Grid 80, Floors 15-17, Frankel shop 1106 plate bill","longitudinalBounds":{"lowerYFt":183.166667,"upperYFt":208.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C80-F17-F19-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"80","startNode":"CORE-C80-F17-F19-reinforcement-0-a","endNode":"CORE-C80-F17-F19-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d72 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.535,"centerZ":0,"width":2,"depth":12.5},{"centerX":2.535,"centerZ":0,"width":2,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":2.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1120","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C80-F17-F19"],"sourceIds":["frankel-E117A","frankel-shop-1120"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1120.TIF"],"sourceRegion":"Grid 80, Floors 17-19, Frankel shop 1120 plate bill","longitudinalBounds":{"lowerYFt":208.666667,"upperYFt":234.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C80-F19-F21-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"80","startNode":"CORE-C80-F19-F21-reinforcement-0-a","endNode":"CORE-C80-F19-F21-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.035,"centerZ":0,"width":1,"depth":12.5},{"centerX":2.035,"centerZ":0,"width":1,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1142","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C80-F19-F21"],"sourceIds":["frankel-E117A","frankel-shop-1142"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1142.TIF"],"sourceRegion":"Grid 80, Floors 19-21, Frankel shop 1142 plate bill","longitudinalBounds":{"lowerYFt":234.166667,"upperYFt":259.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C81-F7-F9-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"81","startNode":"CORE-C81-F7-F9-reinforcement-0-a","endNode":"CORE-C81-F7-F9-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d73 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-3.035,"centerZ":0,"width":3,"depth":12.5},{"centerX":3.035,"centerZ":0,"width":3,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":3.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1081","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C81-F7-F9"],"sourceIds":["frankel-E117A","frankel-shop-1081"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1081.TIF"],"sourceRegion":"Grid 81, Floors 7-9, Frankel shop 1081 plate bill","longitudinalBounds":{"lowerYFt":81.166667,"upperYFt":106.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C81-F9-F11-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"81","startNode":"CORE-C81-F9-F11-reinforcement-0-a","endNode":"CORE-C81-F9-F11-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d72 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.535,"centerZ":0,"width":2,"depth":12.5},{"centerX":2.535,"centerZ":0,"width":2,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":2.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1082","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C81-F9-F11"],"sourceIds":["frankel-E117A","frankel-shop-1082"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1082.TIF"],"sourceRegion":"Grid 81, Floors 9-11, Frankel shop 1082 plate bill","longitudinalBounds":{"lowerYFt":106.666667,"upperYFt":132.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C81-F11-F13-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"81","startNode":"CORE-C81-F11-F13-reinforcement-0-a","endNode":"CORE-C81-F11-F13-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.035,"centerZ":0,"width":1,"depth":12.5},{"centerX":2.035,"centerZ":0,"width":1,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1083","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C81-F11-F13"],"sourceIds":["frankel-E117A","frankel-shop-1083"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1083.TIF"],"sourceRegion":"Grid 81, Floors 11-13, Frankel shop 1083 plate bill","longitudinalBounds":{"lowerYFt":132.166667,"upperYFt":157.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C81-F13-F15-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"81","startNode":"CORE-C81-F13-F15-reinforcement-0-a","endNode":"CORE-C81-F13-F15-reinforcement-0-b","section":{"designation":"2 web plates 12.5\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-2.035,"centerZ":0,"width":1,"depth":12.5},{"centerX":2.035,"centerZ":0,"width":1,"depth":12.5}]},"physicalPlateCount":2,"plateWidthIn":12.5,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1083","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C81-F13-F15"],"sourceIds":["frankel-E117A","frankel-shop-1083"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1083.TIF"],"sourceRegion":"Grid 81, Floors 13-15, Frankel shop 1083 plate bill","longitudinalBounds":{"lowerYFt":157.666667,"upperYFt":183.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F7-F9-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F7-F9-reinforcement-0-a","endNode":"CORE-C79-F7-F9-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d73 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-10.45,"centerZ":0,"width":3,"depth":26},{"centerX":10.45,"centerZ":0,"width":3,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":3.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1090","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C79-F7-F9"],"sourceIds":["frankel-E117A","frankel-shop-1090"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1090.TIF"],"sourceRegion":"Grid 79, Floors 7-9, Frankel shop 1090 plate bill","longitudinalBounds":{"lowerYFt":81.166667,"upperYFt":106.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F9-F11-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F9-F11-reinforcement-0-a","endNode":"CORE-C79-F9-F11-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d73 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-10.45,"centerZ":0,"width":3,"depth":26},{"centerX":10.45,"centerZ":0,"width":3,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":3.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1090","shopBillPlateMarks":"PA","coveredSegmentIds":["COLUMN-CORE-C79-F9-F11"],"sourceIds":["frankel-E117A","frankel-shop-1090"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1090.TIF"],"sourceRegion":"Grid 79, Floors 9-11, Frankel shop 1090 plate bill","longitudinalBounds":{"lowerYFt":106.666667,"upperYFt":132.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F11-F13-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F11-F13-reinforcement-0-a","endNode":"CORE-C79-F11-F13-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d72 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-9.95,"centerZ":0,"width":2,"depth":26},{"centerX":9.95,"centerZ":0,"width":2,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":2.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1091","shopBillPlateMarks":"PAA/PA","coveredSegmentIds":["COLUMN-CORE-C79-F11-F13"],"sourceIds":["frankel-E117A","frankel-shop-1091"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1091.TIF"],"sourceRegion":"Grid 79, Floors 11-13, Frankel shop 1091 plate bill","longitudinalBounds":{"lowerYFt":132.166667,"upperYFt":157.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F13-F15-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F13-F15-reinforcement-0-a","endNode":"CORE-C79-F13-F15-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d72 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-9.95,"centerZ":0,"width":2,"depth":26},{"centerX":9.95,"centerZ":0,"width":2,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":2.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"B1091","shopBillPlateMarks":"PAA/PA","coveredSegmentIds":["COLUMN-CORE-C79-F13-F15"],"sourceIds":["frankel-E117A","frankel-shop-1091"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1091.TIF"],"sourceRegion":"Grid 79, Floors 13-15, Frankel shop 1091 plate bill","longitudinalBounds":{"lowerYFt":157.666667,"upperYFt":183.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F15-F17-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F15-F17-reinforcement-0-a","endNode":"CORE-C79-F15-F17-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d72 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-9.95,"centerZ":0,"width":2,"depth":26},{"centerX":9.95,"centerZ":0,"width":2,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":2.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"B1091","shopBillPlateMarks":"PAA/PA","coveredSegmentIds":["COLUMN-CORE-C79-F15-F17"],"sourceIds":["frankel-E117A","frankel-shop-1091"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1091.TIF"],"sourceRegion":"Grid 79, Floors 15-17, Frankel shop 1091 plate bill","longitudinalBounds":{"lowerYFt":183.166667,"upperYFt":208.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F17-F19-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F17-F19-reinforcement-0-a","endNode":"CORE-C79-F17-F19-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-9.45,"centerZ":0,"width":1,"depth":26},{"centerX":9.45,"centerZ":0,"width":1,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"A1092","shopBillPlateMarks":"PAA/PA","coveredSegmentIds":["COLUMN-CORE-C79-F17-F19"],"sourceIds":["frankel-E117A","frankel-shop-1092"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1092.TIF"],"sourceRegion":"Grid 79, Floors 17-19, Frankel shop 1092 plate bill","longitudinalBounds":{"lowerYFt":208.666667,"upperYFt":234.166667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F19-F21-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F19-F21-reinforcement-0-a","endNode":"CORE-C79-F19-F21-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-9.45,"centerZ":0,"width":1,"depth":26},{"centerX":9.45,"centerZ":0,"width":1,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":1.0,"shopFinishedLengthIn":306.0,"shopPieceMark":"B1092","shopBillPlateMarks":"PAA/PA","coveredSegmentIds":["COLUMN-CORE-C79-F19-F21"],"sourceIds":["frankel-E117A","frankel-shop-1092"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1092.TIF"],"sourceRegion":"Grid 79, Floors 19-21, Frankel shop 1092 plate bill","longitudinalBounds":{"lowerYFt":234.166667,"upperYFt":259.666667,"lengthFt":25.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"CORE-C79-F21-F23-reinforcement-0","kind":"column plate assembly","role":"interior","layer":"columns","columnId":"79","startNode":"CORE-C79-F21-F23-reinforcement-0-a","endNode":"CORE-C79-F21-F23-reinforcement-0-b","section":{"designation":"2 side plates 26\u00d71 in","componentDesignation":"W14X730","family":"cover-plate-assembly","plateRectangles":[{"centerX":-9.45,"centerZ":0,"width":1,"depth":26},{"centerX":9.45,"centerZ":0,"width":1,"depth":26}]},"physicalPlateCount":2,"plateWidthIn":26.0,"plateThicknessIn":1.0,"shopFinishedLengthIn":354.0,"shopPieceMark":"A1165","shopBillPlateMarks":"PC","coveredSegmentIds":["COLUMN-CORE-C79-F21-F23"],"sourceIds":["frankel-E117A","frankel-shop-1165"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1165.TIF"],"sourceRegion":"Grid 79, Floors 21-23, Frankel shop 1165 plate bill","longitudinalBounds":{"lowerYFt":259.666667,"upperYFt":289.166667,"lengthFt":29.5,"status":"E117A shop tier plus E117 core splice datums; shop BOM finished length matches"},"note":"Original shop bill establishes plate pair and finished length; cross-section placement follows S17. Welds, end cuts and column roll remain unresolved."},{"id":"PERIMETER-C55-F9-F11-reinforcement-0","kind":"column plate assembly","role":"perimeter","layer":"columns","columnId":"55","startNode":"PERIMETER-C55-F9-F11-reinforcement-0-a","endNode":"PERIMETER-C55-F9-F11-reinforcement-0-b","section":{"designation":"2 web plates 12\u00d71 in","componentDesignation":"W14X550","family":"cover-plate-assembly","plateRectangles":[{"centerX":-1.69,"centerZ":0,"width":1,"depth":12},{"centerX":1.69,"centerZ":0,"width":1,"depth":12}]},"physicalPlateCount":2,"plateWidthIn":12,"plateThicknessIn":1,"shopFinishedLengthIn":298,"shopPieceMark":"A1502","shopBillPlateMarks":"PAB","coveredSegmentIds":["COLUMN-C55-F9-F11"],"sourceIds":["frankel-E117","frankel-shop-1502"],"sourcePaths":["sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117.tif","sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1502.TIF"],"sourceRegion":"Grid 55, Floor 9\u201311, A1502 revised PAB bill, upper mill line and section B\u2013B","longitudinalBounds":{"lowerYFt":107.333334,"upperYFt":132.166667,"lengthFt":24.833333333333332,"status":"A1502 upper mill marked COL. & PL-PAB; revised 24 ft 10 in finished cut sets lower end 8 in above splice 9"},"note":"A1502 revised 12 \u00d7 1 in PAB pair matches the S17/E117 section; section B\u2013B confirms two web faces. Actual welds, edge preparation and column roll remain unresolved."}],"counts":{"shopVerifiedAssemblies":36,"physicalPlates":72,"coveredReinforcedScheduleRecords":37,"reinforcedScheduleRecords":62,"unresolvedReinforcedScheduleRecords":25,"shopVerifiedAssembliesByColumn":{"55":1,"70":2,"73":7,"76":7,"79":8,"80":7,"81":4}},"coveredSegmentIds":["COLUMN-C55-F9-F11","COLUMN-CORE-C70-F7-F9","COLUMN-CORE-C70-F9-F11","COLUMN-CORE-C73-F11-F13","COLUMN-CORE-C73-F13-F15","COLUMN-CORE-C73-F15-F17","COLUMN-CORE-C73-F17-F19","COLUMN-CORE-C73-F19-F21","COLUMN-CORE-C73-F7-F9","COLUMN-CORE-C73-F9-F11","COLUMN-CORE-C76-F11-F13","COLUMN-CORE-C76-F13-F15","COLUMN-CORE-C76-F15-F17","COLUMN-CORE-C76-F17-F19","COLUMN-CORE-C76-F19-F21","COLUMN-CORE-C76-F7-F9","COLUMN-CORE-C76-F9-F11","COLUMN-CORE-C76-SHOPSTART-SPLICE7","COLUMN-CORE-C79-F11-F13","COLUMN-CORE-C79-F13-F15","COLUMN-CORE-C79-F15-F17","COLUMN-CORE-C79-F17-F19","COLUMN-CORE-C79-F19-F21","COLUMN-CORE-C79-F21-F23","COLUMN-CORE-C79-F7-F9","COLUMN-CORE-C79-F9-F11","COLUMN-CORE-C80-F11-F13","COLUMN-CORE-C80-F13-F15","COLUMN-CORE-C80-F15-F17","COLUMN-CORE-C80-F17-F19","COLUMN-CORE-C80-F19-F21","COLUMN-CORE-C80-F7-F9","COLUMN-CORE-C80-F9-F11","COLUMN-CORE-C81-F11-F13","COLUMN-CORE-C81-F13-F15","COLUMN-CORE-C81-F7-F9","COLUMN-CORE-C81-F9-F11"],"unresolvedScheduleRecords":[{"segmentId":"COLUMN-C1-F7-SPLICE7","columnId":"1","sourceFile":"wtc7_lower_column_schedule","reason":"The Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate. Its E117 predecessor shop drawing is absent from the checked FOIA 12-009 release; the plate cut and end registration are unverified.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A106","reviewStatus":"predecessor-sheet-missing"},{"segmentId":"COLUMN-C1-F7-F9","columnId":"1","sourceFile":"wtc7_lower_column_schedule","reason":"E117 assigns the fifth-tier shop piece, but the checked hand-drawn sheet does not yet establish a transcribed finished plate length and both end datums.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1324","reviewStatus":"hand-drawn-bounds-unverified","reviewedShopSourceId":"frankel-shop-1324"},{"segmentId":"COLUMN-C5-F7-F9","columnId":"5","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists multiple short flange-plate cuts rather than one continuous pair; their individual longitudinal positions remain unregistered.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1340","reviewStatus":"multiple-short-plate-cuts","reviewedShopSourceId":"frankel-shop-1340"},{"segmentId":"COLUMN-C5-F9-F11","columnId":"5","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists multiple short flange-plate cuts rather than one continuous pair; their individual longitudinal positions remain unregistered.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1478","reviewStatus":"multiple-short-plate-cuts","reviewedShopSourceId":"frankel-shop-1478"},{"segmentId":"COLUMN-C5-F11-F13","columnId":"5","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists multiple short flange-plate cuts rather than one continuous pair; their individual longitudinal positions remain unregistered.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1635","reviewStatus":"multiple-short-plate-cuts","reviewedShopSourceId":"frankel-shop-1635"},{"segmentId":"COLUMN-C5-F13-F15","columnId":"5","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists multiple short flange-plate cuts rather than one continuous pair; their individual longitudinal positions remain unregistered.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1636","reviewStatus":"multiple-short-plate-cuts","reviewedShopSourceId":"frankel-shop-1636"},{"segmentId":"COLUMN-C5-F15-F17","columnId":"5","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists multiple short flange-plate cuts rather than one continuous pair; their individual longitudinal positions remain unregistered.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1637","reviewStatus":"multiple-short-plate-cuts","reviewedShopSourceId":"frankel-shop-1637"},{"segmentId":"COLUMN-C5-F17-F19","columnId":"5","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists multiple short flange-plate cuts rather than one continuous pair; their individual longitudinal positions remain unregistered.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1648","reviewStatus":"multiple-short-plate-cuts","reviewedShopSourceId":"frankel-shop-1648"},{"segmentId":"COLUMN-C8-F7-SPLICE7","columnId":"8","sourceFile":"wtc7_lower_column_schedule","reason":"The Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate. Its E117 predecessor shop drawing is absent from the checked FOIA 12-009 release; the plate cut and end registration are unverified.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A108","reviewStatus":"predecessor-sheet-missing"},{"segmentId":"COLUMN-C8-F7-F9","columnId":"8","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists multiple short flange-plate cuts rather than one continuous pair; their individual longitudinal positions remain unregistered.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1341","reviewStatus":"multiple-short-plate-cuts","reviewedShopSourceId":"frankel-shop-1341"},{"segmentId":"COLUMN-C28-F7-SPLICE7","columnId":"28","sourceFile":"wtc7_lower_column_schedule","reason":"The Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate. Its E117 predecessor shop drawing is absent from the checked FOIA 12-009 release; the plate cut and end registration are unverified.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A115","reviewStatus":"predecessor-sheet-missing"},{"segmentId":"COLUMN-C28-F7-F9","columnId":"28","sourceFile":"wtc7_lower_column_schedule","reason":"E117 assigns the fifth-tier shop piece, but the checked hand-drawn sheet does not yet establish a transcribed finished plate length and both end datums.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1323","reviewStatus":"hand-drawn-bounds-unverified","reviewedShopSourceId":"frankel-shop-1323"},{"segmentId":"COLUMN-C32-F7-SPLICE7","columnId":"32","sourceFile":"wtc7_lower_column_schedule","reason":"The Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate. Its E117 predecessor shop drawing is absent from the checked FOIA 12-009 release; the plate cut and end registration are unverified.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A63","reviewStatus":"predecessor-sheet-missing"},{"segmentId":"COLUMN-C38-F7-SPLICE7","columnId":"38","sourceFile":"wtc7_lower_column_schedule","reason":"The Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate. Its E117 predecessor shop drawing is absent from the checked FOIA 12-009 release; the plate cut and end registration are unverified.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A62","reviewStatus":"predecessor-sheet-missing"},{"segmentId":"COLUMN-C42-F7-SPLICE7","columnId":"42","sourceFile":"wtc7_lower_column_schedule","reason":"The Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate. Its E117 predecessor shop drawing is absent from the checked FOIA 12-009 release; the plate cut and end registration are unverified.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A117","reviewStatus":"predecessor-sheet-missing"},{"segmentId":"COLUMN-C42-F7-F9","columnId":"42","sourceFile":"wtc7_lower_column_schedule","reason":"E117 assigns the fifth-tier shop piece, but the checked hand-drawn sheet does not yet establish a transcribed finished plate length and both end datums.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1325","reviewStatus":"hand-drawn-bounds-unverified","reviewedShopSourceId":"frankel-shop-1325"},{"segmentId":"COLUMN-C45-F9-F11","columnId":"45","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists a 12\u00bd \u00d7 1 in web-plate pair 24 ft 10 in long, where the S17/E117 schedule calls 12 \u00d7 1 in plates over a 25 ft 6 in band. Shop mill-line and 8-in end details give partial longitudinal registration, but the physical 12\u00bd-in width has not been reconciled with the 12-in design section.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1551","reviewStatus":"short-plate-offset-unverified","reviewedShopSourceId":"frankel-shop-1551"},{"segmentId":"COLUMN-C45-F11-F13","columnId":"45","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists a 12\u00bd \u00d7 1 in web-plate pair 24 ft 10 in long, where the S17/E117 schedule calls 12 \u00d7 1 in plates over a 25 ft 6 in band. Shop mill-line and 8-in end details give partial longitudinal registration, but the physical 12\u00bd-in width has not been reconciled with the 12-in design section.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1554","reviewStatus":"short-plate-offset-unverified","reviewedShopSourceId":"frankel-shop-1554"},{"segmentId":"COLUMN-C55-F11-F13","columnId":"55","sourceFile":"wtc7_lower_column_schedule","reason":"The assigned shop bill lists a 12\u00bd \u00d7 1 in web-plate pair 24 ft 10 in long, where the S17/E117 schedule calls 12 \u00d7 1 in plates over a 25 ft 6 in band. Shop mill-line and 8-in end details give partial longitudinal registration, but the physical 12\u00bd-in width has not been reconciled with the 12-in design section.","erectionSourceId":"frankel-E117","reviewedShopPieceMark":"A1662","reviewStatus":"short-plate-offset-unverified","reviewedShopSourceId":"frankel-shop-1662"},{"segmentId":"COLUMN-CORE-C70-F7-SPLICE7","columnId":"70","sourceFile":"wtc7_interior_column_schedule","reason":"This Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate section. Its predecessor shop's plate cut and end registration have not been verified; the checked upper-tier bills do not establish this short plate."},{"segmentId":"COLUMN-CORE-C73-F7-SPLICE7","columnId":"73","sourceFile":"wtc7_interior_column_schedule","reason":"This Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate section. Its predecessor shop's plate cut and end registration have not been verified; the checked upper-tier bills do not establish this short plate."},{"segmentId":"COLUMN-CORE-C74-F7-SPLICE7","columnId":"74","sourceFile":"wtc7_interior_column_schedule","reason":"This Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate section. Its predecessor shop's plate cut and end registration have not been verified; the checked upper-tier bills do not establish this short plate."},{"segmentId":"COLUMN-CORE-C79-F7-SPLICE7","columnId":"79","sourceFile":"wtc7_interior_column_schedule","reason":"This Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate section. Its predecessor shop's plate cut and end registration have not been verified; the checked upper-tier bills do not establish this short plate."},{"segmentId":"COLUMN-CORE-C80-F7-SPLICE7","columnId":"80","sourceFile":"wtc7_interior_column_schedule","reason":"This Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate section. Its predecessor shop's plate cut and end registration have not been verified; the checked upper-tier bills do not establish this short plate."},{"segmentId":"COLUMN-CORE-C81-F7-SPLICE7","columnId":"81","sourceFile":"wtc7_interior_column_schedule","reason":"This Floor 7-to-splice-7 slice retains the preceding Floor 5\u20137 plate section. Its predecessor shop's plate cut and end registration have not been verified; the checked upper-tier bills do not establish this short plate."}],"sources":[{"id":"frankel-E117A","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117A.tif","sha256":"2184736397fb9695c06e93ed9d049f262bbdab2a198ab8d5010cc7f24c669b2c","description":"Core column erection schedule; identifies grid, tier and shop-piece assignment."},{"id":"frankel-E117","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_E_Sheets/E Sheets/7WTC - E1/E117.tif","sha256":"6f6fdbebe2df66bcc0f545e51d6c961e69abb33018f369d0ed605b64c21c0027","description":"Perimeter column erection schedule; identifies grid, tier and shop-piece assignment."},{"id":"frankel-shop-1323","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1323.TIF","sha256":"692ead5c53f2d303d5c0027c0d264c7714068355c0d3bea536fc6efaaa7b888c","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1324","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1324.TIF","sha256":"06cd76a240cb1c31f043b494b616978dd4d1e8a44b79d80448acedb0f912f2ca","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1325","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1325.TIF","sha256":"00931f11e3f949146c6e1c8d4f4127155f93eff58c8477893af19844403194ed","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1340","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1340.TIF","sha256":"b36a4b7e51ab965f51f70f356546acc3b53822671aa3dd9dece3540f1e2996ae","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1341","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1341.TIF","sha256":"5baa8d7f6d1bd3cc3962c81768d2e4eb72333b4be37a2462a261eefee02a8e9e","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1478","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1478.TIF","sha256":"28f6fd5b4d1180066a5ed58f51e87eb31a2e055b88d748af10c0654eb68444cd","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1502","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1502.TIF","sha256":"9a3576732f710f53761b92a43b4342464ce3b8c6dbc93a0d992a9152d85a84fd","description":"Perimeter C55 fifth-tier revised bill: two 12 \u00d7 1 \u00d7 24 ft 10 in PAB web plates; upper mill line is marked column and PAB; section B\u2013B confirms plates on both web faces."},{"id":"frankel-shop-1551","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1551.TIF","sha256":"400c90fc54bd9775baa4afbc0573c09ff3401fa0b8fdc1f7bcb1f7fd148391df","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1554","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1554.TIF","sha256":"9f2d0db97703bb0a1ffa1efeeaa5bceab0062ce149a781640f7b244305739255","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1635","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1635.TIF","sha256":"def82b8e9a2943ddc5970c5fdf737cd9414883c5a6547dbed5c74c4eb04e2cf9","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1636","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1636.TIF","sha256":"7efe86437af574634251f8edbedbf328002b59bd2e21a791deef2299b5b47288","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1637","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1637.TIF","sha256":"164623f6f95fc7a4a6ceaf61fcff189cd390f19446fed47d2ad7e02ad67affdb","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1648","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1648.TIF","sha256":"609f8f67e47f4e67043d4bcbb53e8b343534e8abf4d9dd58df3793914a780c5d","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1662","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_2/Detail Sheets 2/7WTC - D2/1662.TIF","sha256":"7113d8247db80a26bd103c6fa9826d0fc6a107f7583b5ea1661eab2856d81b44","description":"Perimeter shop drawing reviewed for original plate cuts; geometry remains unresolved."},{"id":"frankel-shop-1078","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1078.TIF","sha256":"504ec34b26533f1d1b848da1909b64d981171438a42eb0573c92d02bf6e9ce1a","description":"Grid 70, two adjacent tiers: BOM PA quantity four, two pairs 12\u00bd \u00d7 1 in, 25 ft 6 in finished length each."},{"id":"frankel-shop-1040","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1040.TIF","sha256":"c5611961af4c51ab17de46cb914207c655b49e449ce8097f0e8dee58d6650270","description":"Grid 73, Floors 7-9: BOM PA pair 12.5 \u00d7 6.5 in, 25.5 ft finished length."},{"id":"frankel-shop-1041","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1041.TIF","sha256":"8ad5c91a4d973b8f607db065ee42c806291f58d48a454f1ecec739044987e2e7","description":"Grid 73, Floors 9-11: BOM PA pair 12.5 \u00d7 6 in, 25.5 ft finished length."},{"id":"frankel-shop-1042","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1042.TIF","sha256":"958630e6ca633f575054384a02a02e3e9564ad36ce3b7fcd8512e84bb703b487","description":"Grid 73, Floors 11-13: BOM PA pair 12.5 \u00d7 5 in, 25.5 ft finished length."},{"id":"frankel-shop-1043","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1043.TIF","sha256":"01e7e83e83dd658379eff998a5a4522d04f3e5b6b94df91a5913f88cf5a4bef7","description":"Grid 73, Floors 13-15: BOM PA pair 12.5 \u00d7 4 in, 25.5 ft finished length."},{"id":"frankel-shop-1121","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1121.TIF","sha256":"e10e6bcf1a158dd737c9002358a0fd34d6ab5a832983a1ea7e6fb5934288eb32","description":"Grid 73, Floors 15-17: BOM PA pair 12.5 \u00d7 3 in, 25.5 ft finished length."},{"id":"frankel-shop-1122","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1122.TIF","sha256":"9b8cad2dd45c7d006d13a0a7757417183479a9964d27afc648e6b41699b4326f","description":"Grid 73, Floors 17-19: BOM PA pair 12.5 \u00d7 2 in, 25.5 ft finished length."},{"id":"frankel-shop-1137","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1137.TIF","sha256":"f9adf5302d5cd71f1b9e4707e44cc31b179671658c2dcfe5716ec93f07275f12","description":"Grid 73, Floors 19-21: BOM PA pair 12.5 \u00d7 1 in, 25.5 ft finished length."},{"id":"frankel-shop-1044","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1044.TIF","sha256":"1fca16c1a946f28df41ea0ac9185b9b366dc8261ed249a9edbc2b48b7f5c4bdc","description":"Grid 76, Floors 7-9: BOM PA pair 12.5 \u00d7 8 in, 29.4583 ft finished length."},{"id":"frankel-shop-1045","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1045.TIF","sha256":"380474c17125f71abd01fae0844b82f33c8e795a7badb7ea3eac73e9ca4f117e","description":"Grid 76, Floors 9-11: BOM PA pair 12.5 \u00d7 6 in, 25.5 ft finished length."},{"id":"frankel-shop-1076","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1076.TIF","sha256":"302a3cded1533d5879f6b8595722fbd6c407f4613cafeee555992a67c0bb54f3","description":"Grid 76, Floors 11-13: BOM PA pair 12.5 \u00d7 5 in, 25.5 ft finished length."},{"id":"frankel-shop-1077","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1077.TIF","sha256":"96399188bb83fc4943ee49522f1b169ea32da38fef4fb85dc92bcabf03abc38d","description":"Grid 76, Floors 13-15: BOM PA pair 12.5 \u00d7 4 in, 25.5 ft finished length."},{"id":"frankel-shop-1123","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1123.TIF","sha256":"89d7f2b77a7e00f788d0b6de33ccf12d923e42274ad868fc04f5b5c2f37f5b35","description":"Grid 76, Floors 15-17: BOM PA pair 12.5 \u00d7 3 in, 25.5 ft finished length."},{"id":"frankel-shop-1124","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1124.TIF","sha256":"0b985b331e740a1820ada334dec5fcdf257c52292862978db623f717083be29d","description":"Grid 76, Floors 17-19: BOM PA pair 12.5 \u00d7 2 in, 25.5 ft finished length."},{"id":"frankel-shop-1140","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1140.TIF","sha256":"34e89b761f2170a4af27e872167bdb32b4f85c99c465148c31fdcf44e1d5d0f1","description":"Grid 76, Floors 19-21: BOM PA pair 12.5 \u00d7 1 in, 25.5 ft finished length."},{"id":"frankel-shop-1084","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1084.TIF","sha256":"e73b7767abc55a999e5a415af510be9e7544e666c914ba5d9d109feba3369af0","description":"Grid 80, Floors 7-9: BOM PA pair 12.5 \u00d7 8 in, 25.5 ft finished length."},{"id":"frankel-shop-1085","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1085.TIF","sha256":"6fdf42df27c82b526cca32b57ad51e16d2f1ce725febecae3dd6325e11ebe2a7","description":"Grid 80, Floors 9-11: BOM PA pair 12.5 \u00d7 6 in, 25.5 ft finished length."},{"id":"frankel-shop-1086","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1086.TIF","sha256":"18a5a68807c26663891c6f8c2466af975c1b9a459465893d26dd625dc6974126","description":"Grid 80, Floors 11-13: BOM PA pair 12.5 \u00d7 5 in, 25.5 ft finished length."},{"id":"frankel-shop-1087","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1087.TIF","sha256":"a3486efce567f4139292663d9a6445207ca1b8d9a296d289b1c4affd5da635ee","description":"Grid 80, Floors 13-15: BOM PA pair 12.5 \u00d7 4 in, 25.5 ft finished length."},{"id":"frankel-shop-1106","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1106.TIF","sha256":"d9d1ff8f4ae68e44e6211f84d3a54965c38ea449639eb751582dab74870a469f","description":"Grid 80, Floors 15-17: BOM PA pair 12.5 \u00d7 3 in, 25.5 ft finished length."},{"id":"frankel-shop-1120","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1120.TIF","sha256":"fec7bf4d07ed311b271177d32493c9d3eb75d6dfe8d96ad11153c9e1cfef48a7","description":"Grid 80, Floors 17-19: BOM PA pair 12.5 \u00d7 2 in, 25.5 ft finished length."},{"id":"frankel-shop-1142","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1142.TIF","sha256":"a930033814ff9fdc65bb4245c97cb7c70be9ae01f8b1686d887de3daf7065666","description":"Grid 80, Floors 19-21: BOM PA pair 12.5 \u00d7 1 in, 25.5 ft finished length."},{"id":"frankel-shop-1081","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1081.TIF","sha256":"82f63d942d8274e8eb31faa25f74214c212299e74ff0662c2200ff704e0dbb36","description":"Grid 81, Floors 7-9: BOM PA pair 12.5 \u00d7 3 in, 25.5 ft finished length."},{"id":"frankel-shop-1082","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1082.TIF","sha256":"7f239718303ff85e46eea02c397c7373ddda0b939c70728b45177efc5843cbfb","description":"Grid 81, Floors 9-11: BOM PA pair 12.5 \u00d7 2 in, 25.5 ft finished length."},{"id":"frankel-shop-1083","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1083.TIF","sha256":"091e36a1d1d0367ce581dde84601379a6022aec11d8ed183957879d96a8c2b41","description":"Grid 81, two adjacent tiers: BOM PA quantity four, two pairs 12\u00bd \u00d7 1 in, 25 ft 6 in finished length each."},{"id":"frankel-shop-1090","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1090.TIF","sha256":"33e6d21442274ff22f3dba784f0514cc8abd9701fe469ef59555e024e34a0f37","description":"Grid 79: BOM PAA/PA side plates, quantity 4, 26 \u00d7 3 in, 25 ft 6 in finished length each."},{"id":"frankel-shop-1091","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1091.TIF","sha256":"21ec08cebece53dce71374eb277949830ebead253472e5c861dc25e991f73fe6","description":"Grid 79: BOM PAA/PA side plates, quantity 6, 26 \u00d7 2 in, 25 ft 6 in finished length each."},{"id":"frankel-shop-1092","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1092.TIF","sha256":"b7142f195535c161baa1cc0b93d6f68a63e4019b9b71526f38b8eb7a15537b8a","description":"Grid 79: BOM PAA/PA side plates, quantity 4, 26 \u00d7 1 in, 25 ft 6 in finished length each."},{"id":"frankel-shop-1165","path":"sources/wtc7/drawings/expanded-releases/12-009/NIST_WTC7_FOIA_12-009/NIST_WTC7_FOIA_12-009_WTC7_Details_1/Detail Sheets 1/1165.TIF","sha256":"6cd230abe0fbee31f40847bc1096638df7a889978b1d080adc33ae1249367ba2","description":"Grid 79, twelfth tier: BOM PC side plates, quantity two, 26 \u00d7 1 in, 29 ft 6 in finished length each."}],"limitations":["Only plate pairs with original shop BOM finished lengths, registered longitudinal bounds and matching E117/E117A piece assignments are emitted.","Floor 7 source schedule partitions C76 shop 1044; its two schedule records are one continuous 29 ft 5 1/2 in plate pair.","S17 typical cross-section supplies plate placement; actual column roll, welds, edge preparation and splice connection geometry remain unverified.","The remaining reinforced schedule records require original shop-specific plate lengths and longitudinal registration before drawing.","E117 perimeter shop assignments are recorded for all 20 reinforced perimeter cells; only A1502 has a revised section and longitudinal registration suitable for this detail frame."]}